ONGRATULATIONS ON CHOOSING A QUALITY SMART SPA FOR YOUR BACKYARD RELAXATION
!
P
LEASE READ THE OWNER’S MANUAL COMPLETELY BEFORE INSTALLING AND USING YOUR NEW SPA
OF THIS MANUAL IS TO PROVIDE YOU WITH SAFETY, OPERATIONAL AND INSTALLATION INFORMATION WHICH WILL
ALLOW YOU THE FULLEST ENJOYMENT OF THIS FINE PRODUCT
.
. THE
PURPOSE
AT
THE TIME OF PRINTING, THIS MANUAL WAS DEEMED AS ACCURATE AS POSSIBLE
RIGHT TO CHANGE PRODUCT IN AN EFFORT TO ENHANCE AND IMPROVE, WITHOUT PRIOR NOTICE
ANY OF THESE POSSIBLE CHANGES, LOG ON TO WWW.PDCSPAS.COM
TION, OR CONTACT YOUR RETAILER DIRECTLY
___________________________________________________
___________________________________________________
___________________________________________________
I
SERIAL NUMBER PLATE IS BEHIND CABINET PANEL ON WALL OF HOT TUB BEHIND THE CONTROL
SAVE THIS MANUAL FOR EASY FUTURE REFERENCE !
.
T
ABLE OF CONTENTS
I
MPORTANT SAFETY INSTRUCTIONS
W
ARNINGS
SPA USE L
L
ABELS
OCATION AND REFERENCE
SPA P
ARTS IDENTIFICATION
SPA P
S
ART TERMINOLOGY AND DESCRIPTION
UPPORT EQUIPMENT TERMINOLOGY AND DESCRIPTION
SPA S
PECIFICATIONS
SPA I
NSTALLATION
G
E
I
W
W
E
I
NITIAL START-UP
G
SPA L
OCATION CONSIDERATIONS
ENERAL LOCATION CONSIDERATIONS
QUIPMENT LOCATION
NSTALLING THE THERMAL COVER
IRING INSTALLATION
IRING RECOMMENDATIONS
U.S. –S
TATE-SIDE GUIDELINES
XPORT, IN.XE
ENERAL
O
PERATION SYSTEMS
IN.K 200 C
W
ATER CHEMISTRY GUIDELINES
M
AINTENANCE RECOMMENDATIONS
W
INTERIZING YOUR HOT TUB
T
ROUBLESHOOTING
R
ECORDS OF SPA CARE
, I
NSTRUCTIONS FOR ALL SPA MODELS
7
10-13
, I
NDOORS AND OUTDOORS
CE P
LATFORM
21
G
UIDELINES
22
ONTROL
23-25
26, 27
28, 29
30
31
32
1-6
8
9
14, 15
16
17
18
19
20
S
AFETY INSTRUCTIONS
YOU
NOW OWN A HIGH QUALITY SMART SPA BUILT FOR YEARS OF ENJOYMENT AND
RELAXATION
YOUR SPA AND ENJOY IT WITH SAFETY IN MIND
THOROUGHLY AND UNDERSTAND ALL OF THE SAFETY PRECAUTIONS
WITHIN THESE GUIDELINES ASSURES YEARS OF FUN AND RELAXATION GAINED FROM
. IT IS OF
1
PRIME IMPORTANCE THAT YOU UNDERSTAND THE OPERATION OF
. YOU
SHOULD READ THIS MANUAL
. U
SING YOUR SPA
ADDING A SMART SPA TO YOUR LIFESTYLE
.
WARNING
T
HIS UNIT IS A PROFESSIONAL-GRADE PRODUCT
A
KNOWLEDGE OF CONSTRUCTION TECHNIQUES
PLUMBING AND ELECTRICAL INSTALLATION ACCORDING
TO CODES ARE REQUIRED FOR PROPER INSTALLATION AND
USER SATISFACTION
A LICENSED CONTRACTOR PERFORM THE INSTALLATION
W
ARRANTY IS VOIDED FOR IMPROPER
I
NSTALLATION RELATED ISSUES
. IT IS
RECOMMENDED THAT
.
SAVE THESE INSTRUCTIONS
I
NCLUDED WITH THIS MANUAL IS A SAFETY SIGN THAT IS TO BE POSTED NEAR THE SPA
WHERE ALL OCCUPANTS CAN EASILY READ
GUEST’S PROTECTION, SAFETY AND TO ASSURE THEIR SPA ENJOYMENT
POINT OUT THE LOCATION OF THE SIGN AND INDICATE THE IMPORTANCE OF THE PRECAUTIONS
A
DHERE THE SIGN WITH SCREWS OR ANOTHER MANNER OF PERMANENT ADHESION
S
HOULD YOU REQUIRE ADDITIONAL COPIES OR REPLACEMENTS, SIMPLY CONTACT THE
FACTORY DIRECTLY OR YOUR NEAREST RETAILER
. T
HIS SIGN IS INTENDED FOR YOU AND YOUR
.
.
,
.
. T
AKE THE TIME TO
.
.
2
S
AFETY INSTRUCTIONS
READ AND FOLLOW ALL IMPORTANT SAFETY INSTRUCTIONS
W
HEN INSTALLING AND USING THIS EQUIPMENT BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE TAKEN TO
REDUCE THE RISK OF ELECTRICAL SHOCK, TO ENSURE SAFE USAGE, AND TO SAFEGUARD THE USER’S HEALTH
.
READ AND FOLLOW
ALL INSTRUCTIONS!!
T
HIS UNIT IS A PROFESSIONAL-GRADE PRODUCT
. A
KNOWLEDGE OF CONSTRUCTION
TECHNIQUES, PLUMBING AND ELECTRICAL INSTALLATION ACCORDING TO CODES ARE
REQUIRED FOR PROPER INSTALLATION AND USER SATISFACTION
THAT A LICENSED CONTRACTOR PERFORM THE INSTALLATION
FOR IMPROPER INSTALLATION RELATED ISSUES
.
. IT IS
. W
RECOMMENDED
ARRANTY IS VOIDED
IT IS
THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT ALL USERS OF THE SPA ARE ADEQUATELY
INFORMED OF ALL PRECAUTIONS
.
USE
THE SPA ONLY AS DESCRIBED IN THIS MANUAL
THE SPA IN A COMMERCIAL OR RENTAL SETTING
. THE
SPA IS INTENDED FOR HOME USE ONLY
. ALL
WARRANTIES WILL BE VOIDED
. DO
.
GROUND ALL METAL ELECTRICAL EQUIPMENT
• A
GREEN COLORED TERMINAL OR A TERMINAL MARKED
INSIDE THE SUPPLY TERMINAL BOX OR COMPARTMENT
GROUNDING MEANS PROVIDED IN THE ELECTRIC SUPPLY SERVICE PANEL, USING A CONTINUOUS COPPER
WIRE EQUIVALENT IN SIZE TO THE CIRCUIT CONDUCTORS SUPPLYING THIS EQUIPMENT
*
ACCORDING TO, BUT NOT LIMITED TO
• AT
• ALL
• ALL
LEAST TWO LUGS MARKED
INSIDE OF THE SUPPLY TERMINAL BOX OR COMPARTMENT
GRID (HOUSEHOLD GROUND) IN THE AREA OF THE SPA TO THESE TERMINALS, USING AN INSULATED OR
BARE COPPER CONDUCTOR NOT SMALLER THAN NO
FIELD-INSTALLED METAL COMPONENTS SUCH AS RAILS, LADDERS, DRAINS OR SIMILAR HARDWARE
LOCATED WITHIN
WITH COPPER CONDUCTORS NOT SMALLER THAN NO
METAL SURFACES WITHIN
5
FEET OF THE SPA OR HOT TUB MUST BE BONDED TO THE EQUIPMENT GROUNDING BUS
: NEC, NFPA 70, S
“B
ONDING LUGS” ARE PROVIDED ON THE EXTERNAL SURFACE OR ON THE
5
FEET OF THE SPA MUST BE BONDED TO THE HOME BONDING GRID
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FAULT CIRCUIT INTERRUPTER TYPE CIRCUIT BREAKER
IN THE HOME PANEL BOX BY A LICENSED ELECTRICIAN WHEN MAKING WIRE CONNECTION TO THE SPA
SUPPORT PACK EQUIPMENT
PAS ARE PERMANENTLY INSTALLED UNITS
SPA EQUIPMENT SYSTEMS MUST BE PROTECTED BY A CLASS A
(GFCI) OR
EQUIVALENT
.
. GROUND FAULT CIRCUIT INTERRUPTER
; RCD,
(NOT SUPPLIED)
FOR EXPORT INSTALLS
MUST BE INSTALLED
. A
DANGER: RISK OF ELECTRICAL SHOCK:
• I
NSTALL THE SPA AT LEAST FIVE FEET
• G
ROUND FAULT CIRCUIT INTERRUPTER PROTECTION OF THE HOME POWER SUPPLY TO THE SPA IS
NECESSARY
•
DO
WITHIN FIVE FEET
FROM THE SPA
. Y
OUR ELECTRICIAN SHOULD EXPLAIN HOW IT WORKS
NOT PERMIT ANY ELECTRIC APPLIANCE, SUCH AS A LIGHT, TELEPHONE, RADIO OR TELEVISION
(1.52 M) OF A
. W
ATER IS A CONDUCTOR OF ELECTRICITY
SPA
(1.52 M)
. K
EEP ELECTRICAL APPLIANCES AND EXTENSION CORDS AWAY
FROM ALL UNGROUNDED (UNBOUNDED) METAL SURFACES
. (SEE
SPA MAINTENANCE
.
)
NOT USE
.
,
.
3
S
AFETY INSTRUCTIONS
DANGER: RISK OF ACCIDENTAL DROWNING.
• E
XTREME CAUTION MUST BE EXERCISED TO PREVENT UNAUTHORIZED ACCESS BY CHILDREN
ACCIDENTS, ENSURE THAT CHILDREN CANNOT USE A SPA UNLESS THEY ARE SUPERVISED AT ALL TIMES
. TO
DANGER: TO REDUCE THE RISK OF DROWNING:
1. N
2. C
3. K
EVER USE THE SPA ALONE
HILDREN SHOULD NOT USE THE SPA UNLESS THEY ARE SUPERVISED BY AN ADULT
EEP PETS AWAY FROM THE SPA AT ALL TIMES
.
.
4. ALWAYS REPLACE AND LOCK THE SPA COVER WHEN THE SPA IS NOT IN USE.
DANGER: TO REDUCE THE RISK OF DROWNING
• P
ROLONGED IMMERSION IN THE SPA MAY CAUSE HYPERTHERMIA
EFFECTS OF HYPERTHERMIA MAY BE DESCRIBED AS FOLLOWS
INTERNAL TEMPERATURE OF THE BODY REACHES A LEVEL SEVERAL DEGREES ABOVE THE NORMAL BODY
TEMPERATURE OF
INTERNAL TEMPERATURE OF THE BODY, DIZZINESS, LETHARGY, DROWSINESS, AND FAINTING
EFFECTS OF HYPERTHERMIA INCLUDE
1. F
2. F
3. U
4. F
5. P
6. U
AILURE TO PERCEIVE HEAT
AILURE TO RECOGNIZE THE NEED TO EXIT THE SPA
NAWARENESS OF IMPENDING HAZARD
ETAL DAMAGE IN PREGNANT WOMEN
HYSICAL INABILITY TO EXIT THE SPA
NCONSCIOUSNESS RESULTING IN THE DANGER OF DROWNING
98.6 °F (37°C). THE
:
SYMPTOMS OF HYPERTHERMIA INCLUDE AN INCREASE IN THE
. THE
CAUSES, SYMPTOMS AND
: H
YPERTHERMIA OCCURS WHEN THE
. THE
DANGER: RISK OF INJURY
• DO
NOT REMOVE THE SUCTION FITTINGS
SPECIFIC WATER FLOW CREATED BY THE PUMP
FITTING OR THE PUMP, BE SURE THAT THE FLOW RATES ARE COMPATIBLE
THE SUCTION FITTING IS BROKEN OR MISSING
LESS THAN THE FLOW RATE MARKED ON THE ORIGINAL SUCTION FITTING
. THE
SUCTION FITTING IN THIS SPA IS SIZED TO MATCH THE
. S
HOULD THE NEED ARISE TO REPLACE THE SUCTION
. N
EVER REPLACE A SUCTION FITTING WITH ONE RATED
. N
EVER OPERATE THE SPA IF
.
DANGER: RISK OF ACCIDENTAL DROWNING
• K
EEP HAIR AND BODY PARTS AWAY FROM THE SUCTION GUARD
FREELY IN THE WATER; LONG HAIR SHOULD BE RESTRAINED WITH A BATHING CAP
OF DROWNING FROM HAIR OR BODY ENTRAPMENT, INSTALL A SUCTION FITTING (S) WITH A MARKED
FLOW RATE IN GALLONS PER MINUTE THAT EQUALS OR EXCEEDS THE FLOW RATE MARKED ON THE
EQUIPMENT ASSEMBLY, IF REPLACEMENT OF SUCTION FITTINGS BECOMES NECESSARY
. DO
NOT ALLOW LONG HAIR TO FLOAT
. TO
REDUCE THE RISK
.
WARNING
• G
ROUND FAULT CIRCUIT INTERRUPTER PROTECTION
SHOULD BE TESTED PRIOR TO EACH USE BY THE HOMEOWNER
“
TEST” BUTTON ON THE
MEDIATELY
FAILS TO OPERATE IN THIS MANNER, THERE EXISTS A POSSIBILITY OF ELECTRICAL SHOCK
TESTING APPLIES FOR EXPORT PROTECTION DEVICES, I.E
• D
ISCONTINUE SPA OPERATION BY DISCONNECTING THE POWER SOURCE AND NOTIFY A QUALIFIED ELEC-
TRICIAN FOR IDENTIFICATION AND CORRECTION OF THE PROBLEM
. NOW
GFCI
RESET THE
CIRCUIT BREAKER AT THE PANEL BOX
GFCI. THE
SPA SHOULD RETURN TO NORMAL OPERATION
(GFCI) OR
. W
. RCD.
EQUIVELANT
ITH THE SPA IN OPERATION, PUSH THE
. THE
; RCD,
SPA SHOULD SHUT DOWN IM-
FOR THE SPA
. IF
THE
. A
PPROVED
GFCI
.
AVOID
.
4
S
AFETY INSTRUCTIONS
WARNING
• TO
REDUCE THE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE THIS PRODUCT UNLESS THEY ARE
CLOSELY SUPERVISED AT ALL TIMES
.
WARNING: TO REDUCE THE RISK OF INJURY
• THE
• E
• B
•
• P
• P
• E
WATER IN A SPA SHOULD NEVER EXCEED
(38º C )
TEMPERATURES ARE RECOMMENDED FOR EXTENDED USE (EXCEEDING
YOUNG CHILDREN
EARLY MONTHS OF PREGNANCY
TEMPERATURES TO
THERMOMETER SINCE THE TOLERANCE OF WATER TEMPERATURE REGULATING DEVICES MAY VARY AS
MUCH AS
AND
104º F (40° C)
ARE CONSIDERED SAFE FOR A HEALTHY ADULT
.
XCESSIVE WATER TEMPERATURES HAVE A HIGH POTENTIAL FOR CAUSING FETAL DAMAGE DURING THE
. P
REGNANT OR POSSIBLY PREGNANT WOMEN SHOULD LIMIT SPA
100º F (38° C).
EFORE ENTERING A SPA, THE USER SHOULD MEASURE THE WATER TEMPERATURE WITH AN ACCURATE
5º F (3°C).
104ºF (40° C). W
ATER TEMPERATURES BETWEEN
. L
10 TO 15
OWER WATER
MINUTES) AND FOR
THE USE OF ALCOHOL, DRUGS, OR MEDICATION BEFORE OR DURING SPA USE
MAY LEAD TO UNCONSICIOUSNESS WITH THE POSSIBILITY OF DROWNING.
ERSONS SUFFERING FROM OBESITY OR WITH A MEDICAL HISTORY OF HEART DISEASE, LOW OR HIGH
BLOOD PRESSURE, CIRCULATIORY SYSTEM PROBLEMS, OR DIABETES SHOULD CONSULT A PHYSICIAN
BEFORE USING A SPA
ERSONS USING MEDICATION SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA SINCE SOME
MEDICATION MAY INDUCE DROWSINESS WHILE OTHER MEDICATION MAY AFFECT HEART RATE, BLOOD
PRESSURE, AND CIRCULATION
NTER AND LEAVE SPA SLOWLY AND WITH CAUTION
SLIPPERY
.
.
.
. S
URFACES AROUND SPA WILL BE WET AND
WARNING
1. N
2. DO
3. DO
4. R
5. K
6. THE PH
EVER USE THE SPA ALONE
NOT BRING ANY OBJECT INTO THE SPA THAT COULD DAMAGE THE SPA SHELL
NOT SIT ON SPA COVER OR PLACE OBJECTS ON IT; IT IS NOT DESIGNED TO SUPPORT WEIGHT
EMOVE ANY WATER OR DEBRIS THAT MAY COLLECT ON THE SPA COVER
EEP ALL CHEMICALS AWAY FROM CHILDREN AND PETS
AND CHEMICAL BALANCE OF THE WATER MUST BE MAINTAINED AS EXPLAINED IN THIS
MANUAL
YOUR WARRANTY
. F
AILURE TO DO SO MAY CAUSE INJURY TO USERS OR DAMAGE TO THE SPA, AND WILL VOID
.
.
.
.
.
WARNING: HEALTH CONSIDERATIONS
• THE
• I
• S
USE OF ALCOHOL, DRUGS, MEDICATION CAN GREATLY INCREASE RISK OF FATAL HYPERTHERMIA
NDIVIDUALS WITH INFECTIONS AND OPEN SORES OR WOUNDS SHOULD NOT USE THE SPA
THRIVE IN WARM AND HOT WATER
CHEMICAL BALANCE
HOWER BEFORE AND AFTER USING THE SPA
BODY OILS THAT COULD CONTAMINATE THE WATER
CHEMICALS AND ANY BACTERIA THAT MAY HAVE BEEN IN THE SPA
.
. A
LWAYS KEEP YOUR SPA DISINFECTED AND MAINTAIN THE PROPER
. T
HIS WILL REMOVE ANY DEODORANT, PERSPIRATION, OR
. S
HOWERING AFTER WILL REMOVE ANY RESIDUAL
.
. B
ACTERIA
100° F
.
.
S
AFETY INSTRUCTIONS
5
• DO
• IF
NOT USE THE SPA IMMEDIATELY AFTER STRENUOUS EXERCISE
YOU FEEL PAIN OR DIZZINESS AT ANY TIME WHILE USING THE SPA, DISCONTINUE USE AND CONTACT A
PHYSICIAN
.
.
WARNING: TO REDUCE THE RISK OF INJURY
• IT IS
• THE
• N
• DO
ESPECIALLY IMPORTANT FOR PERSONS OVER THE AGE OF
HEALTH PROBLEMS, SUCH AS OBESITY, HEART DISEASE, HIGH BLOOD PRESSURE, CIRCULATORY
PROBLEMS, OR DIABETES TO CONSULT THEIR PHYSICIAN BEFORE USING THE SPA
SPA JETS PRODUCE A STREAM OF WATER WITH RELATIVELY HIGH PRESSURE
SURE OF A LOCALIZED AREA OF THE BODY MAY CAUSE BRUISES TO THE SKIN
EVER INSERT ANY OBJECT INTO ANY OPENING
NOT USE BREAKABLE CONTAINERS IN OR NEAR THE SPA
.
.
35 OR
PERSONS WITH PRE-EXISTING
.
. P
.
ROLONGED EXPO-
WARNING: ELECTRICAL CONSIDERATIONS
• FOR
• THE
CONTROLS OTHER THAN UNDERWATER LIGHTING CIRCUITS
RUPTER (OR EQUIVELANT FOR EXPORT INSTALLS
TROL AN UNDERWATER LIGHTING FIXTURE
F
AULT CIRCUIT INTERRUPTER SHALL NOT OCCUPY CONDUIT
OTHER CONDUCTORS UNLESS THE ADDITIONAL CONDUCTORS ARE ALSO PROTECTED BY A GROUND
F
AULT CIRCUIT INTERRUPTER (OR EQUIVALENT FOR EXPORT INSTALLS
ELECTRICAL SUPPLY FOR THIS PRODUCT MUST INCLUDE A SUITABLY RATED SWITCH OR CIRCUIT
BREAKER TO OPEN ALL UNDERGROUND SUPPLY CONDUCTORS TO COMPLYWITH SECTION
U.S. N
ATIONAL ELECTRIC CODE
TUB OCCUPANT BUT INSTALLED AT LEAST
. THE
DISCONNECTING MEANS MUST BE READILY ACCESSIBLE TO THE
5 FT (1.5 M)
)
MUST BE PROVIDED IF THIS DEVICE IS USED TO CON-
. THE
CONDUCTORS ON THE LOAD SIDE ON THE GROUND
FROM THE SPA WATER
: A G
ROUND FAULT CIRCUIT INTER-
,
BOXES, OR ENCLOSURES CONTAINING
).
.
WARNING: FOR
1. CAUTION - R
2. CAUTION - R
3. DO
4.
(
COMPONENTS; AND
WARNING
FOR EXAMPLE CABLE, ADDITIONAL SPEAKERS, HEADPHONES, ADDITIONAL AUDIO/VIDEO
COMPONENTS, ETC
5. T
ANSI/NFPA 70.
BE INSTALLED IN ACCORDANCE WITH ARTICLE
6. DO
TO DANGEROUS VOLTAGE OR OTHER RISK OF INJURY
SERVICE PERSONNEL
7. W
8. T
ENTERING THE AUDIO/VIDEO COMPARTMENT OR ANY ELECTRICAL EQUIPMENT COMPARTMENT AREA
IF THE PROTECTIVE SHIELDS OR BARRIERS ARE SHOWING SIGNS OF DETERIORATION; OR IF THERE
ARE SIGNS OF OTHER POTENTIAL DAMAGE TO THE UNIT, TURN OFF THE UNIT AND REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL
HIS UNIT SHOULD BE SUBJECTED TO PERIODIC ROUTINE MAINTENANCE (FOR EXAMPLE, ONCE
EVERY
SPAS WITH AUDIO
ISK OF ELECTRIC SHOCK
ISK OF ELECTRIC SHOCK
/
VIDEO COMPONENTS
. DO
NOT LEAVE COMPARTMENT DOOR OPEN
. R
EPLACE COMPONENTS ONLY WITH IDENTICAL
,
NOT OPERATE THE AUDIO/VIDEO CONTROLS WHILE INSIDE THE SPA
- P
REVENT ELECTROCUTION
.) TO
THE SYSTEM
HESE UNITS ARE NOT PROVIDED WITH AN OUTDOOR ANTENNAE; WHEN PROVIDED, IT SHOULD
NOT SERVICE THIS PRODUCT YOURSELF AS OPENING OR REMOVING COVERS MAY EXPOSE YOU
.
. DO
NOT CONNECT ANY AUXILIARY COMPONENTS
810 OF
THE
U.S. N
. R
EFER ALL SERVICING TO QUALIFIED
ATIONAL ELECTRICAL CODE
.
.
HEN THE POWER SUPPLY CONNECTION OR POWER SUPPLY CORD(S) ARE DAMAGED; IF WATER IS
.
3
MONTHS) TO MAKE SURE THAT THE UNIT IS OPERATING PROPERLY
.
422-20 OF
.
THE
,
;
6
S
AFETY INSTRUCTIONS
ADDITIONAL SAFETY CONSIDERATIONS
• I
• FOR
• W
• DO
• I
• W
NSTALL THE SPA TO PROVIDE DRAINAGE FOR COMPARTMENTS OF ELECTRICAL COMPONENTS
FLOOR RECESSED SPAS
THE FLOOR
DRAINAGE
MATERIALS
THE SPA SPECIFICATION LISTING
SUPPORT EQUIPMENT PER THE MODEL SPECIFICATIONS
. SPA
EQUIPMENT MUST BE INSTALLED BELOW WATER LEVEL
HEN PLANNING YOUR SPA INSTALLATION SITE, PREPARE FOR THE UNLIKELY EVENT OF RAPID SPA
.
NOT PLACE SPA IN DIRECT SUNLIGHT WHILE UNIT IS EMPTY OR WHEN SEALED IN SHIPPING
. E
XCESSIVE HEAT BUILD MAY CAUSE DAMAGE TO SPA AND VOID WARRANTY
NSTALL SPA SO THAT WATER CAN EASILY BE DRAINED OUT
HEN INSTALLING SPA, ALLOW AMPLE SPACE FOR FUTURE SERVICING, NOTING LOCATION OF ALL
: I
NSTALL TO PERMIT ACCESS FOR SERVICING FROM ABOVE OR BELOW
.
.
.
.
,
LOCATING THE SIDE DRAIN VALVE ON
.
SAVE THESE INSTRUCTIONS
7
SPA USE L
A
FOR
WEATHER RESISTANT WARNING SIGN HAS BEEN MOUNTED
ON THE CABINET SIDE OF YOUR PORTABLE SPA
FAMILIAR WITH THE PRECAUTIONS AND EXERCISE SAFETY
AND CARE WHILE ENJOYING YOUR SPA
PRINTED IN ENGLISH AND FRENCH EXPOSED, THREE ADDITIONAL LANGUAGES ARE ON THE REVERSE SIDE
YOU REQUIRE, EXPOSE THE REVERSE SIDE FOR WARNING IN
YOUR NATIVE LANGUAGE
ABELS
C
ABINET PANEL WARNING SIGN
YOUR REFERRAL AND CONVENIENCE, A
.
. T
HIS SIGN IS
. S
. B
HOULD
ECOME
EL
WITH THIS MANUAL INTENDED FOR PERMANENT POSTING
IN AN AREA NEAR THE SPA VISIBLE TO ALL SPA OCCUPANTS
. N
YOU REQUIRE ADDITIONAL SIGNS OR REPLACEMENTS
LISH AND
G
ERMAN
CHOSEN LANGUAGE FOR EASY VIEWING
NCLOSED WARNING SIGN FOR POSTING
OCATE THE WEATHER RESISTANT SIGN ENCLOSED
OTIFY THE FACTORY OR YOUR RETAILER SHOULD
. E
F
RENCH VERSIONS ARE ON ONE SIDE
, I
TALIAN ON THE REVERSE
. M
OUNT WITH YOUR
, S
PANISH
.
A
NG-
,
WARNING:
ITY FOR PERSONAL INJURY OR PROPERTY DAMAGE SUSTAINED BY OR THROUGH THE USE OF THIS PRODUCT
R
EAD ALL INSTRUCTIONS BEFORE USING THE SPA
. S
MART SPAS ASSUMES NO RESPONSIBIL-
SAVE THIS MANUAL, SIGNS, AND INSTRUCTIONS FOR FUTURE REFERENCE.
.
8
SPA P
SPA P
ARTS IDENTIFICATION
ART TERMINOLOGY AND DESCRIPTION
H
YDRO-JETS
S
UCTION
AIR C
SPA M
.
: T
: T
ONTROLS
OOD LIGHT
HESE ARE THE WALL FITTINGS AROUND THE INSIDE PERIMETER OF THE SPA
WITH AIR TO PRODUCE LOCALIZED THERAPY, IN A STRAIGHT STREAM, CIRCULAR MOTION OR IN
RANDOM PATTERNS FOR UPPER AND LOWER BACK MASSAGE IN THE LOUNGE AND CONTOURED
SEATING AREAS
HIS IS A CIRCULAR FITTING MOUNTED ON THE VERTICAL WALL OF THE FOOTWELL AND SERVES
THE SAME FUNCTION AS THE SKIM FILTER
RETURN WATER TO THE SUPPORT EQUIPMENT
: T
HESE ARE ROUND FITTINGS MOUNTED ON THE LIP OF SPA THAT CONTROL THE AMOUNT OF
OUTSIDE AIR MIXED WITH THE INCOMING WATER OF THE HYDRO-JET
AIR CONTROLS ON THE SPA LIP THAT CONTROL AIR/ WATER MIX FOR A SEGMENT OF THE JETS
: U
NDERWATER LOW VOLTAGE LIGHT WITH ADDITIONAL TWO CHANGEABLE COLORED LENSES
FOR NIGHT TIME SPA ENJOYMENT
.
. T
HEY MIX WATER
. IT
WORKS IN CONJUNCTION WITH THE SKIM FILTER TO
.
. Y
OUR SPA HAS MULTIPLE
.
.
S
UPPORT EQUIPMENT IDENTIFICATION
SPA P
ART TERMINOLOGY AND DESCRIPTION
P
UMP
: Y
OUR NEW SPA IS EQUIPPED WITH A DUAL SPEED PUMP FOR FILTRATION AND HYDROTHERAPY
ACTION
ONE BUTTON ON THE SPA SIDE CONTROL, LOCATED ON THE TOP OF THE SPA
IN A FILTRATION MODE OR CALLING FOR HEAT, PUSHING THE BUTTON ONCE WILL TURN THE
PUMP ON LOW SPEED, PUSHING IT A SECOND TIME WILL ENGAGE HIGH SPEED
THE BUTTON WILL TURN THE PUMP OFF
HEAT, THE PUMP WILL ALREADY BE RUNNING ON LOW SPEED
THE PUMP ON HIGH, AND ONCE AGAIN TO GO BACK TO LOW
THE PUMP OFF WHEN THE SPA REACHES ITS PRESET TEMPERATURE, OR THE FILTRATION CYCLE
ENDS
. THE
.
CONTROL CENTER OPERATES THIS PUMP
F
ILTER
: Y
OUR SMART SPA IS EQUIPPED WITH A SKIM FILTER
AND EASE OF CLEANING AT SPA SIDE
FILTER CARTRIDGE CLEANING AND REPLACEMENT
.
H
EATER
: Y
OUR SPA IS EQUIPPED WITH THERMOSTAT CONTROL AT SPA SIDE
TEMPERATURE YOU ENJOY MOST, LEAVE THE THERMOSTAT AT THAT SETTING, AND THE SPA WILL
AUTOMATICALLY MAINTAIN THE CORRECT TEMPERATURE; READY FOR YOUR ENJOYMENT ANY
TIME OF THE DAY
TO MAINTAIN TEMPERATURE, THAN TO LET THE TEMPERATURE FALL AND THEN WAIT DURING
HEAT-UP TIME BEFORE SOAKING
. A
VOID CONSTANT RESETTING OF THE THERMOSTAT; IT IS MORE ECONOMICAL
O
ZONE
: ALL
USE
SPAS WITH OZONE OPTION FOR SANITATION SHOULD CIRCULATE
THE PROGRAMMABLE ELECTRONIC CONTROL CENTER TO PROGRAM THIS OPERATION
9
. TO
TURN THE PUMP ON, PUSH THE PUMP
. IF
THE SPA IS NOT
. A
THIRD PUSH OF
. IF
THE SPA IS IN A FILTRATION CYCLE OR CALLING FOR
. P
USH THE BUTTON ONCE TO TURN
. THE
CONTROL CENTER WILL TURN
. T
HIS ASSURES OPTIMUM WATER FILTERING
. R
EVIEW THE MAINTENANCE SECTION OF THIS MANUAL FOR
.
. O
NCE YOU FIND THE
.
16-24
HOURS DAILY
.
.
10
SPA S
PECIFICATIONS
—O
RBIT SPA MODEL
GENERAL rev. 2009 / 07
Seating Capacity 6
Shell Material Polyethylene
Dimensions (Domestic) 78” Round x 36” deep
Dimensions (Export) 198 cm.Round 91cm. deep
Water Capacity 340 Gallons, 1287 Liters
Dry Weight 300Lbs, 136Kg
Skirt Material PermaWood™
Water Flow 187 Gallons per Minute
WATER SYSTEM** (photo ref.)
Water Treatment System Ozone Ready
Filter 25 sq. ft.
Slide Valves 2
Mega Swirl Jet A 2
Large Euro Jet w/ Eyeball E 17
Mega’ssage Jet G 1
Multi’ssage Jet P 0
Ozone Jet O 1
Diverter Valves V 0
Safety Suction U 2
Mini Skimmer K 0
Air Control I 2
Spa Light L 1
Drain Valve 5 0
E
E
A
E
E
A
U
O
G
U
L
I
E
I
SPECIAL FEATURES
Spa Pillows
Motion Glow™ Light
Stainless Steel Jetting
Waterfall Jet WF
Waterfall Control Valve C
SoundWave™ SE Audio
Ozone Water Purification OZ
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak(Continuous)
HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XE Series
Voltage 240 240
Amperage 40 2x16 / 1x32
Heater
Operation System
Main Spa Side Control 7 Gecko 200 Control Gecko 200 Control
Secondary Spa Side Control 8 N/A N/A
N/A
N/A
Optional
N/A
N/A
N/A
Standard
1 4.0 (2.0) HP 4.0 (2.0) HP
4.0 KW 4.0 KW
7
6, 1
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
11
SPA S
GENERAL rev. 2009 / 07
Seating Capacity 6
Shell Material Polyethylene
Dimensions (Domestic) 78” Round x 36” deep
Dimensions (Export) 198 cm.Round 91cm. deep
Water Capacity 340 Gallons, 1287 Liters
Dry Weight 300Lbs, 136Kg
Skirt Material PermaWood™
Water Flow 140 Gallons per Minute
WATER SYSTEM** (photo ref)
Water Treatment System Ozone Ready
Filter 25 sq. ft.
Slide Valves 2
Mega Swirl Jet A 1
Large Euro Jet w/ Eyeball E 11
Mega’ssage Jet G 1
Ozone Jet O 1
Multissage Jet P 0
Diverter Valves V 0
Safety Suction U 2
Mini Skimmer K 0
Air Control I 2
Spa Light L 1
Drain Valve 5 0
SPECIAL FEATURES
Spa Pillows N/A
Motion Glow™ Light N/A
PECIFICATIONS
—O
RBIT FLEX SPA MODEL
E
E
E
G
E
A
U
O
U
L
I
7
I
1
6
E
Stainless Steel Jetting Optional
Waterfall Jet WF N/A
Waterfall Control Valve C N/A
SoundWave™ SE Audio N/A
Ozone Water Purification OZ Standard
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XE Series
Voltage 120/240 240
Amperage 20/40 2x16 / 1x32
Heater
Operation System
Main Spa Side Control 7 Gecko 200 Series Gecko 200 Series
Secondary Spa Side Control 8 N/A N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
1.0 KW / 4.0 KW 4.0 KW
12
SPA S
GENERAL rev. 2009 / 07
Seating Capacity 6
Shell Material Polyethylene
Dimensions (Domestic) 78” (6’6”) sq. x 36” (3’0”)
Dimensions (Export) 198 cm. sq. x 92 cm.
Water Capacity 350 Gallons, 1325 Liters
Dry Weight 365 Lbs, 166Kg
Skirt Material PermaWood™
Water Flow 187 Gallons Per Minute
WATER SYSTEM** (photo ref)
Water Treatment System Ozone ready
Filter 25 sq. ft.
Slide Valves 2
Mega Swirl Jet A 3
Large Euro Jet w/ Eyeball E 18
Mega’ssage Jet G 3
Multi’ssage Jet P 0
Ozone Jet O 1
Diverter Valves V 0
Safety Suction U 2
Mini Skimmer K 0
Air Control I 2
Spa Light L 1
Drain Valve 5 0
SPECIAL FEATURES
Spa Pillows N/A
Motion Glow™ Light N/A
Stainless Steel Jetting Optional
Waterfall Jet WF N/A
Waterfall Control Valve N/A
SoundWave™ SE Audio N/A
Ozone Water Purification OZ Standard
PECIFICATIONS
—Q
UADRA SPA MODEL
A
E
G
U
L
E
I I
7
E
G
A
E
U O
A
G
1, 6
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 4.0 (2.0) HP 4.0 (2.0) HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XE Series
Voltage 240 240
Amperage 40 2x16 / 1x32
Heater
Operation System
Main Spa Side Control 7 Gecko 200 Series Gecko 200 Series
Secondary Spa Side Control 8 N/A N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
4.0 KW 4.0 KW
13
SPA S
GENERAL rev. 2009 / 07
Seating Capacity 6
Shell Material Polyethylene
Dimensions (Domestic) 78.5” sq. x 33“
Dimensions (Export) 198 cm. sq. x 92 cm.
Water Capacity 350 Gallons, 1325 Liters
Dry Weight 365 Lbs, 166 Kg
Skirt Material PermaWood™
Water Flow 140 Gallons Per Minute
WATER SYSTEM** (photo ref.)
Water Treatment System Ozone ready
Filter 25 sq. ft.
Slide Valves 2
Mega Swirl Jet A 1
Large Euro Jet w/ Eyeball E 11
Mega’ssage Jet G 2
Multi’ssage Jet P 0
Ozone Jet O 1
Diverter Valves V 0
Safety Suction U 2
Mini Skimmer K 0
Air Control I 2
Spa Light L 1
Drain Valve 5 0
PECIFICATIONS
—Q
UADRA FLEX SPA MODEL
E
E
E
E
E
G
G
E
E
E
U
U
O,L
E
E
A
E
7
1, 6
I I
SPECIAL FEATURES
Spa Pillows N/A
Motion Glow™ Light N/A
Stainless Steel Jetting Optional
Waterfall Jet WF N/A
Waterfall Control Valve C N/A
SoundWave™ SE Audio N/A
Ozone Water Purification OZ Standard
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak(Continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP
Electronics
Electrical Can 6 Gecko XE Series Gecko XE Series
Voltage 120/240 240
Amperage 20/40 2x16 / 1x32
Heater
Operation System
Main Spa Side Control 7 Gecko 200 Series Gecko 200 Series
Secondary Spa Side Control 8 N/A N/A
1.0 KW/4.0 KW 4.0 KW
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
14
SPA I
I
NSTALLATION GUIDELINES
THE
MENT
ACCUMULATION, WATER SPILL-OVER, ETC. WHICH ARE CONSIDERATIONS FOR THOSE LOCATED INSIDE
NSTALLATION
LOCATION OF YOUR SPA IS AN IMPORTANT FACTOR IN GUARANTEEING YOUR MAXIMUM SPA ENJOY-
. G
ENERALLY, MOST SPAS ARE INSTALLED OUTDOORS WITH NO CONCERNS REGARDING MOISTURE
O
UTDOOR INSTALLATION CONSIDERATIONS
1. L
2. C
YOU
3. V
4. D
5. N
6. L
7. C
8. IF
C
9. A
10. BE
11. P
12. L
BE GROUND FAULT CIRCUIT PROTECTED AT THE POWER SOURCE.
ALL ELECTRICAL WIRING OF THE SPA SUPPORT EQUIPMENT MUST COMPLY
WITH THE NATIONAL ELECTRIC CODE.
13. L
MUST COMPLY WITH ARTICLE 680 OF THE U.S. NATIONAL ELECTRIC CODE AND
ANSI/NFPA 70-1984.
14. P
OCAL ELECTRICAL AND PLUMBING CODES
ONSIDER LOCAL CODES PERTAINING TO FENCING, ENCLOSURES, WALLS, ELECTRICAL AND PLUMBING
BOTH ABOVE GROUND AND UNDERGROUND
IEW FROM HOUSE FOR AESTHETICS AND SUPERVISORY NEEDS
ISTANCE FROM HOUSE FOR WINTERTIME SOAKING
IGHTTIME LIGHTING
OCATE THE SPA WITH AN AWARENESS TO SUNLIGHT EXPOSURE, VIEWS, ACCESS, PROPERTY LINES
LIGHTING, WIND DIRECTION, SHIELDING, SEPTIC TANKS, PLANTS, TREES
WATER SPLASHED FROM YOUR SPA MAY DAMAGE NEARBY PLANT LIFE
ONSIDER THE LOCATION OF THE NEAREST BATHROOM
YOUR SPA IS TO BE LOCATED ON A SECOND STORY, BE POSITIVE SUPPORT IS ADEQUATE
REA FOR PLACEMENT OF SUPPORT EQUIPMENT WHERE ADEQUATE SPACE WILL BE NEEDED TO GAIN
ACCESS TO COMPONENTS FOR MAINTENANCE AND GENERAL SERVICING
SURE TO NOTE ANY OTHER CONSIDERATIONS, SUCH AS AESTHETICS OR PRIVACY CONCERNS, THAT
MAY AFFECT THE SAFETY OR ENJOYMENT OF USING THE SPA
ROVIDE ADEQUATE DRAINAGE AWAY FROM THE EQUIPMENT AND ADEQUATE ELEVATION TO ALLOW
DRAINING BY SIPHON, IF SHOULD BE REQUIRED
OCATION OF ELECTRICAL SUPPLY
THE ELECTRICAL SOURCE TO THE SPA SUPPORT PACK TERMINAL
OCATIONS AT LEAST
WITHIN
5
FEET OF METALS SURFACES PROVIDING EACH METAL SURFACE IS PERMANENTLY
CONNECTED BY A NO
CONNECTOR ON THE TERMINAL BOX PROVIDED FOR THIS PURPOSE
LACE THE SPA ON A FIRM, LEVEL SURFACE THAT WILL NOT SHIFT
.
WILL NEED TO ENSURE THAT YOUR SPA IS AN ADEQUATE DISTANCE FROM POWER LINES
. Y
OUR SPA WILL ALSO NEED TO BE CHILDPROOFED
.
.
.
. (C
HEMICALS IN THE SPA
.)
.
.
ALL YOUR BUILDER
. 8AWG (8.4 MM2)
.
5 FT (1.52 M)
.
.
. 120/240
VOLT SYSTEMS REQUIRE HARD WIRE INSTALLED FROM
. ALL EQUIPMENT MUST
FROM ALL METAL SURFACES
COPPER CONDUCTOR ATTACHED TO THE WIRE
. (A
SPA MAY BE INSTALLED
.) ALL INSTALLATIONS
.
.
.
.
,
.
,
15
SPA I
I
NSTALLATION GUIDELINES
I
1. L
2. V
3. C
4. D
5. C
6. C
7. R
8. DO
9. THE
NSTALLATION
NDOOR
I
NSTALLATION CONSIDERATIONS
OCAL ELECTRICAL AND PLUMBING CODES
ENTILATION FANS AND/OR DEHUMIDIFIERS SHOULD BE PROVIDED TO HANDLE THE HIGH HUMIDITY
DEVELOPED BY YOUR SPA
HEMICALS WILL VAPORIZE FROM THE WATER AND MAY CAUSE AN ODOR AND POSSIBLY CORROSION
TO CERTAIN HOME HARD-WARE
URING THE NORMAL USE OF THE SPA, WATER WILL ESCAPE THE SPA VESSEL
ON OR OVER ANY MATERIAL WHICH MAY BE DAMAGED BY THIS WATER OR THE CHEMICALS
WITHIN THE WATER
AVOID WATER DAMAGE, EVEN IF THE SPA SHOULD LOSE ALL ITS WATER
ONSIDER AND PREPARE FOR THE UNLIKELY EVENT OF RAPID SPA DRAINAGE
SPA IS PERMANENT, YOU MAY WISH TO PROVIDE FLOOR DRAINS TO ACCOMMODATE DRAINING
ETC
NECESSARY
ONSIDER AND PREPARE FOR THE UNLIKELY EVENT OF SPA REMOVAL
EAD
7-14 IN
NOT SET SPA ON FINISHED FLOOR WITHOUT A WATERPROOF BARRIER PROTECTION UNDERNEATH
SPA SHOULD HAVE ACCESS TO A POWER SOURCE CAPABLE OF SUPPLYING
IT
I
10. THE
11. BE
12. DO
13. THE
14. BE
NTERRUPTER
SHOULD BE ON THE SAME CIRCUIT
SPA SHOULD BE CLOSE TO A SOURCE OF WATER
SURE THAT THE LOCATION YOU CHOOSE IS STABLE
THE SPA WHEN IT IS FILLED WITH WATER, PLUS THE WEIGHT OF THE OCCUPANTS
WEIGH UP TO
NOT USE THE SPA ABOVE A FINISHED LIVING AREA, DUE TO THE RISK OF WATER DAMAGE
SPA IS NOT DESIGNED FOR IN-FLOOR INSTALLATION
SYSTEM THAT IS BUILT FLUSH WITH THE TOP OF THE SPA, PROVIDED YOU LEAVE ACCESS FOR
SERVICE
SURE TO NOTE ANY OTHER CONSIDERATIONS, SUCH AS AESTHETICS OR PRIVACY CONCERNS, THAT
MAY AFFECT THE SAFETY OR ENJOYMENT OF USING THE SPA
WARNING:
A KNOWLEDGE OF CONSTRUCTION TECHNIQUES, PLUMBING AND ELECTRICAL
INSTALLATION ACCORDING TO CODES ARE REQUIRED FOR PROPER INSTALLATION
AND USER SATISFACTION. WE RECOMMEND THAT A LICENSED CONTRACTOR
PERFORM THE INSTALLATION. OUR WARRANTY DOES NOT COVER
.
. W
ALLS, CEILING AND WOOD TRIM SHOULD BE RESISTANT, ALSO
. N
EVER STORE CHEMICALS INSIDE THE SPA CABINET
. N
EVER PLACE THE SPA
. K
EEP DAMAGEABLE MATERIALS FAR ENOUGH AWAY FROM THE SPA TO
.
. IF
PLACEMENT OF THE
. A
LWAYS LEAVE ROOM ALL AROUND THE SPA FOR EASY ACCESS IN CASE REPAIRS ARE
.
.
THE OUTDOOR INSTALLATIONS INFORMATION
MUST BE WIRED DIRECTLY INTO A GROUNDED CIRCUIT WITH A GROUND FAULT CIRCUIT
(G.F.C.I.)OR
EQUIVALENT
RCD,
.
FOR EXPORT INSTALLS
240
VOLTS
. NO
OTHER APPLIANCES
.
.
. IT
MUST BE ABLE TO SUPPORT THE WEIGHT OF
6000
LBS
( 2722 KG.)
WHEN IT IS FILLED WITH WATER
. H
OWEVER, IT IS COMPATIBLE WITH A DECK
.
.
.
THIS IS A PROFESSIONAL GRADE PRODUCT.
IMPROPER INSTALLATION-RELATED PROBLEMS.
.
AC
. THE
POWER
SPA MAY
.
.
,
.
.
16
SPA I
G
ENERAL LOCATION CONSIDERATIONS
R
LOCATION
LBS
ON THE GROUND
PREPARING THE SITE FOR THE HOT TUB INSTALLATION
NSTALLATION
EVIEW OUTDOOR INSTALLATIONS AND INDOOR INSTALLATIONS PRIOR TO CHOOSING YOUR SPA
. Y
OUR SPA SHOULD BE PLACED ON A LEVEL CONCRETE PAD OR ON A DECK DESIGNED TO SUPPORT
(2722 KG.) OR ON
. O
PATIO BLOCKS ON THE GROUND
NCE YOU HAVE A LOCATION SELECTED, THERE ARE SEVERAL ISSUES YOU SHOULD CONSIDER IN
A
IS FILLED, IT HAS CONSIDERABLE WEIGHT
OF
100
SPA RESULTING FROM THE INCORRECT INSTALLATION OF PLACEMENT ON INADEQUATE FOUNDATION IS NOT COVERED IN THE SPA’S LIMITED WARRANTY
FLAT, LEVEL SURFACE THAT IS STRONG ENOUGH TO SUPPORT YOUR SPA IS REQUIRED
LBS
(45.4 KG)
PER SQUARE FOOT LOAD, PER RECOMMENDED GUIDELINES
M
DECK
UNIT IS PLACED DIRECTLY ON THE GROUND, YOU WILL WANT TO REMOVE THE GRASSY LEVEL, AND PLACE A LAYER
OF GRAVEL ON THE SOIL
SOLID LUMBER TO ACHIEVE A LEVEL SURFACE
CONVENIENT WAY TO PREPARE THE LOCATION SITE
TENDENCY TO SETTLE AND MAY BECOME
AT LEAST FOUR INCHES THICK WITH THE REINFORCING MESH OR ROD ATTACHED TO A BOND WIRE
OST UNITS ARE INSTALLED OUTSIDE, ON GROUND LEVEL, ON EITHER A CONCRETE PAD OR A WOODEN
. IF
THE SPA IS NOT ON GROUND LEVEL, HAVE A BUILDER DETERMINE IF THE SUPPORT IS ADEQUATE
. THE
M
ONTO THE WEB SITE OR CALL YOUR RETAILER FOR DIMENSIONS OF THE MODEL YOU HAVE CHOSEN
PERIMETER OF THE CHOSEN GROUND SURFACE TO EXTEND BEYOND THE SPA ITSELF TO PROVIDE A CLEAN AREA
FOR USERS TO GET IN AND OUT OF THE SPA
AKE SURE YOUR DIMENSIONS ARE CORRECT AS YOU PREPARE THE SITE FOR YOUR NEW HOT TUB
THE
SPA LOCATION AND THE SPA ITSELF MUST BE LEVEL BEFORE FILLING WITH WATER
S
RESISTANT QUALITIES, IF A PRESSURE-TREATED TYPE LUMBER IS USED
CONSULT A BUILDER TO DETERMINE IF YOUR DECK IS OF ADEQUATE STRENGTH
HOULD YOUR SPA SITE BE A WOODEN DECK, THIS PROVIDES A CLEAN AREA WITH WEATHER AND ROT
IF
UNLIKELY EVENT OF RAPID SPA DRAINAGE
INSTALLING YOUR HOT TUB BELOW GRADE, CONSIDER ADEQUATE DRAINAGE FOR RUN-OFF AND THE
A
CABINET
THE SUPPORT EQUIPMENT FOR THE MODEL YOU HAVE CHOSEN
LLOW ADEQUATE SPACE TO ACCESS THE EQUIPMENT BEHIND THE FOUR ACCESS PANELS ON THE HOT TUB
. R
EVIEW THE PAGES IN THIS MANUAL REFERENCING SPA MODEL SPECIFICATIONS FOR THE LOCATION OF
L
EAVE AMPLE ACCESS TO THE
A
SPA AND WITHIN THE LINE OF SIGHT FROM THE HOT TUB
ING AND PREPARING THE SPA SITE
QUICK DISCONNECT (MANUAL DISCONNECT) IS TO BE INSTALLED BETWEEN
A
EASY DRAINING
A
DVANTAGEPACK DESIGN; WITH THIS FEATURE, ALL THE EQUIPMENT IS LOCATED BENEATH AN END CABINET
A
LLOW EASY ACCESS TO ALL COMPONENTS
CABINET SIDE DRAIN HAS BEEN INSTALLED ON THE BOTTOM PORTION OF A CABINET SIDEWALL FOR
. L
OCATE THIS DRAIN AND LEAVE AMPLE ACCESS
6000
. DO
NOT PLACE THE SPA ON A DIRT SURFACE OR DIRECTLY
.
. O
NCE YOUR SPA
. M
AKE CERTAIN THE LOCATION YOU CHOOSE CAN SUPPORT A MINIMUM
. S
TRUCTURAL DAMAGE TO THE
.
BEST WAY TO LEVEL THE GRAVEL MAY BE WITH THE STRAIGHT EDGE OF A PIECE OF
. P
AVERS PLACED IN A SAND BASE IS ALSO A RATHER QUICK AND
. N
OTE THAT PAVERS, STEPPING STONES, ETC. STILL HAVE A
UNLEVEL AT SOME POINT
. A
REINFORCED CONCRETE SLAB SHOULD BE
.
. A
LLOW A
.
.
. C
ONSIDER THE LOAD REQUIREMENTS AND
.
.
.
GFCI
CIRCUIT BREAKER FOR TESTING, ETC
.
5 - 15 FT (1.5-4.6 M) OF
. C
ONSIDER WHERE THIS CAN BE LOCATED WHEN
. ALL
WIRING MUST COMPLY WITH THE
. Y
. T
HIS DESIGN ALSO FEATURES A SIDE DRAIN FOR EMPTYING
U.S. N
ATIONAL ELECTRIC CODE
OUR SPA MAY HAVE BEEN CHOSEN WITH THE
.
. IF
. C
SELECT-
.
THE
LICK
THE
.
17
SPA I
E
QUIPMENT LOCATION
A
CESS PANEL USING A SQUARE HEAD SCREWDRIVER
TION
NSTALLATION
FTER THE HOT TUB HAS BEEN PLACED IN THE DESIRED
)
N
ELECTRICAL BOX AND PUMP
THE ELECTRICAL BOX
AROUND THE NECESSARY CABINET SIDES TO ACCESS EQUIPMENT
R
EVIEW YOUR SPA MODEL SPECIFICATION PAGE IN THIS MANUAL FOR
A GUIDE OF EQUIPMENT LOCATION FOR THAT SPECIFIC SPA MODEL
EXT, PULL AWAY THE CABINET PANEL AND LOCATE THE
N
OTE THE LOCATION OF THE ELECTRICAL BOX, THIS WILL NEED TO
BE ACCESSED TO COMPLETE THE WIRING CONNECTION TO THE
HOME POWER SOURCE
LOCATION REMOVE A CABINET AC-
. (SEE
. N
OTE THE HEATER ATTACHED BELOW
. BE
SURE YOU HAVE ALLOWED AMPLE SPACE
.
ILLUSTRA-
.
.
C
HECK THAT ALL VALVES: TWO PER PUMP, ARE OPEN AND THE LOCKING CLIP HAS REMAINED SNAPPED ON THE VALVE STEM DURING
SHIPMENT
THE
LARS (UNIONS) FOR EASE OF FUTURE SERVICING
TIGHTEN ALL COLLARS CHECKING FOR ANY WHICH MAY HAVE LOOSENED DURING SHIPMENT
. ( SEE
SPA EQUIPMENT HAS BEEN ASSEMBLED WITH NUMEROUS COL-
ILLUSTRATION
)
. L
OCATE AND HAND
.
-
18
SPA I
I
NSTALLING THE THERMAL COVER
R
THE SPA COVER AND HOLD LATCH AGAINST THE CABINET SIDE
PANEL
PERSON HOLD THE STRAP TIGHT ON THE OPPOSITE SIDE OF
THE SPA COVER
PLACE THE LATCH OVER THE GROOVES OF THE CABINET FINISH
TO THE CABINET SIDE PANEL WITH THREE
PROVIDED
CABINET IN THE SAME MANNER
NSTALLATION
EMOVE THE SPA COVER FROM THE BOX AND PLACE IT ON THE SPA
. TO
POSITION THE LOCK CORRECTLY, HAVE A SECOND
. THE
. R
EMOVE THE LATCH FROM THE LOCK, ATTACH THE LOCK
. A
TTACH THE OTHER THREE LOCKS TO THE
SPA COVER MUST BE TIGHT
. P
ULL DOWN ONE OF THE STRAPS ON
. DO
NOT
#4
SCREWS
.
TO
SPA COVER INTO THE LOCKS ON THE CABINET SIDE PANEL
COVER IN PLACE, INSERT THE KEY AND TURN IT CLOCKWISE
TO
UNLOCK THE LATCHES, INSERT THE KEY AND TURN IT COUNTERCLOCKWISE
SPA IS NOT IN USE
OF CHILDREN
SECURE THE HOT TUB COVER, SNAP THE LATCHES ON THE
. TO
1/4
1/4
TURN
. A
LWAYS KEEP THE COVER LOCKED WHEN THE
. K
EEP THE KEYS IN A SAFE PLACE, OUT OF THE REACH
.
LOCK THE
TURN
.
19
W
IRING INSTALLATION
W
IRING GUIDELINES
ALL EQUIPMENT MODELS ARE 120/240 VOLT, 60 CYCLE FOR STATE-SIDE, U.S. INSTALLATIONS,
AND 50 HZ FOR EXPORT, CE, INSTALLATIONS.
• ALL SPAS MUST BE PERMANENTLY CONNECTED.
• ALL SPA SUPPORT SYSTEMS ARE MULTIPLE SUPPLY CIRCUITS.
•
ALL SPA SYSTEMS REQUIRE THE INSTALLATION OF A GROUND FAULT CIRCUIT INTERRUPTER
PROTECTOR (GFCI) OR EQUIVALENT; RCD, FOR EXPORT INSTALLS, AT THE POWER SOURCE
(NOT SUPPLIED) BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL CODES AND
REGULATIONS. REFER TO TYPICAL G.F.C.I. INSTALLATION ON FOLLOWING PAGE.
• PRIOR TO EACH USE, TESTING OF THE GFCI (OR EQUIVALENT) IS REQUIRED. REFER TO THE MAINTE
NANCE SECTION OF THIS MANUAL FOR INSTRUCTIONS.
• ALL SPA SUPPORT EQUIPMENT MUST BE BONDED (GROUNDED) TO THE PRESSURE CONNECTOR LOCATED WITHIN THE CONTROL PANEL, AS WELL AS THE BONDING TERMINAL LOCATED ON
THE OUTSIDE OF THE CONTROL PANEL. (see wiring schematic below)
• DISCONNECT ALL ELECTRICAL SUPPLIES AND CONTACT A QUALIFIED TECHNICIAN BEFORE SERVICING.
• ALL SPA INSTALLATIONS ARE TO BE PERFORMED BY A LICENSED ELECTRICIAN AND IN ACCORDANCE
WITH ALL LOCAL AND NATIONAL CODES.
O
PTION
O
PTION
1
M
AIN PANEL
C
IRCUIT BREAKER
G.F.C.I.
2
M
AIN PANEL
C
IRCUIT BREAKER
* N
ATIONAL
SPA W
IRING SCHEMATIC FOR CERTIFIED ELECTRICIANS
U.S.
CODE RECOMMENDS DISTANCE NOT TO EXCEED
W
IRE
“A” W
W
IRE
“A” W
D
ISCONNECT
D
ISCONNECT
G.F.C.I.
15 FT.
’ R
EFERENCE ONLY
IRE
IRE
“B” *
“B” *
SPA
SPA
W
IRING INSTALLATION
W
IRING GUIDELINES
ALL S
MART SPA UNITS MUST BE INSTALLED WITH AN APPROVED
ALL APPLICABLE CODES
F
OLLOW EACH MANUFACTURER’S GUIDELINES TO ENSURE PROPER OPERATION AND
PROTECTION OF SPA OCCUPANTS
20
—STATE-SIDE GUIDE-
- S
TATE-SIDE
(U.S. I
NSTALLATIONS
)
ATTENTION ELECTRICIAN:
G.F.C.I. IN
. I
NSTALLATION OF
BE USED ONLY AS A REFERENCE FOR THE INSTALLING ELECTRICIAN
T
YPICAL INSTALLATION BREAKER BOX
C
LASS
A 50
G.F.C.I.
. T
HIS DIAGRAM IS A
AMP
, 120/240
VARIES AMONG THOSE MANUFACTURERS
“T
YPICAL” INSTALLATION TO
VOLT
, GFCI
ACCORDANCE WITH
.
.
Ground Bar Attached
To Box Input & Output
Ground to Spa
Ground Input
Load 120V
(Black) To Spa
Load 120V
(Red) To Spa
Load Neutral
(White) To Spa
To Spa (OUTPUT)
Line (BLACK)
House Input
Line (RED)
House Input
Pig Tail (WHITE) From GFCI
Breaker Going to Neutral
Bar in Box
Load Neutral Bar
Line Neutral (WHITE) House
Input
From House (INPUT)
TO BE NOTED: Installation of this GFCI Circuit
Breaker, including ampere sizing and choice of qualified
electrician in accordance with the National Electrical
Code, and all applicable federal, state and local codes and
regulations in effect at the time of installation.
IMPORTANT: 6 G
T
EST
GFCI M
AUGE COPPER WIRE
ONTHLY AND PRIOR TO EACH USE
TO BE NOTED: The white neutral wire
from the back of the GFCI Circuit Breaker
MUST be connected to an incoming Line
Neutral. The internal mechanism of the
GFCI requires this Neutral connection for
proper GFCI function.
MUST BE U
SED
.
21
W
IRING INSTALLATION
—EXPORT GUIDELINES IN.XE
INSTALLATION GUIDELINES for IN.XE CE
ALL
INSTALLATIONS AND CONNECTIONS ARE TO BE PERFORMED BY A QUALIFIED, LICENSED ELECTRICIAN ONLY AND IN
ACCORDANCE WITH LOCAL REGULATIONS
WITH THE HOME’S ELECTRICAL OUTPUT, AND FOLLOW THE GUIDELINES BELOW
MAKING ANY ELECTRICAL CONNECTIONS
. I
DENTIFY THE CORRECT
.
CE
PLATFORM ON THE SPA UNIT, IN ACCORDANCE
. E
NSURE POWER IS TURNED OFF PRIOR TO
!
Warning!
This product must always be connected to a circuit protected by a residual-current device (RCD) having
a rated operating residual-current not exceeding 30 mA. Proper wiring of the electrical service box, RCD
and in.xe.ce terminal block is essential! Check your electrical code for local regulations. Only copper
wire should be used, never aluminum.
IN.XE P
LATFORM CONTROL CENTER
1 x 230 VAC (1 x 32A) single phase,
or
1 x 230 VAC (2 x 16A) dual phase **
Bonding lug
Correct wiring of the electrical service
box, RCD protection device, and pack
terminal block is essential!
Contact qualified, licensed electrician.
IN.XE.CE
(Single phase input Only; multi-phase not supported)
32 A absolute maximum, 50 Hz nominal.
ELECTRICAL SPECIFICATIONS
Input rating: 230 VAC nominal
:
** Contact your retailer for electrical specifications and connection instructions when this option becomes available.
In.XE CE 230 VAC
Single phase ONLY
I
NITIAL START-UP
G
ENERAL GUIDELINES
1. BE
SURE THAT THE POWER IS TURNED OFF AT THE MAIN CIRCUIT BREAKER
2. CAUTION: E
3. F
ILL SPA TO THE RECOMMENDED LEVEL, ASSURING ALL SUCTION OUTLETS ARE COVERED WITH WATER
4. M
AKE SURE VALVES ON THE SUCTION AND RETURN SIDES OF THE SPA PUMP ARE OPEN TO ALLOW WATER TO
5. IF
6. T
7. P
8. T
9.W
10.SET
11.THE
FLOW TO AND FROM THE SPA AND SPA SUPPORT SYSTEM
THE PUMP IS AIR-LOCKED, LOCATE PUMP
TURNS
URN POWER “ON” AT MAIN CIRCUIT BREAKER
RESS JET
URN ALL AIR REGULATOR KNOBS TO “OFF” POSITION
HEN THE SYSTEM HAS FULLY PRIMED, ALL THE JETS SHOULD BE FREELY ROTATING AND FREE OF EXCESS AIR
EXCEPT THE JETS ATTACHED TO OZONE, IF THIS OPTION IS INCLUDED ON THE SYSTEM
SYSTEM TO OPERATE FOR FIVE MINUTES IN THIS POSITION
THE THERMOSTAT TO THE DESIRED TEMPERATURE TO BEGIN HEATING THE SPA WATER
ICON ON THE SPA SIDE CONTROL WILL BE ON WHEN THE SPA IS HEATING
ECONOMICAL, GRADUAL HEATING OF THE WATER TAKES PLACE OVER A NUMBER OF HOURS, DEPENDING
UPON THE SIZE OF THE SPA, SIZE OF THE HEATER AND THE RECOMMENDED USE OF A SMART SPA COVER
W
12. SET
13.C
14.C
THIS SETTING, THE TEMPERATURE WILL AUTOMATICALLY BE MAINTAINED
TURE WITH AN ACCURATE THERMOMETER BEFORE ENTERING THE SPA
THE FILTRATION PROGRAM TO DESIRED SETTING PER INSTRUCTIONS FOUND IN THE CONTROL CENTER
SECTION OF THIS MANUAL
HEMICALLY TREAT THE SPA WATER
INSTRUCTIONS ON CONTAINER OF ANY PRODUCT USED
OVER THE SPA WITH THERMAL COVER TO MAINTAIN TEMPERATURE AND LOCK FOR SAFETY
22
.
LECTRIC HEATER ELEMENT MUST BE FULLY SUBMERGED IN WATER BEFORE BEING ENERGIZED
.
#1,
LOOSEN RETURN FITTING FROM THE TOP OF THE PUMP A FEW
. A
FTER ABOUT
/
PUMP BUTTON TO ACTIVATE CYCLE
HEN THE DESIRED TEMPERATURE IS REACHED, NOT OVER
10
SECONDS, TIGHTEN UNION AND CONTINUE START-UP
.
.
.
.
104˚F (40˚C).
.
. R
EAD THE SECTION ON WATER CHEMISTRY MAINTENANCE AND FOLLOW
.
.
. A
LLOW THE
. THE
.
LEAVE THE THERMOSTAT AT
. RE-
CHECK WATER TEMPERA
.
.
.
INDICATOR
.
;
.
O
PERATION SYSTEMS
- 200 S
23
ERIES CONTROL
WARNING: R
personal injury or property damage sustained by or through the use of this product. When installing and using this equipment
basic safety precautions should always be taken to reduce risk of electrical shock, ensure safe usage, and safeguard the user’s health.
EAD ALL INSTRUCTIONS BEFORE USING THE SPA
. Smart Spas assumes no responsibility for
In.K200
Spa Functions
Singlepumpsystem
Key 1
Press Key 1 key to turn pump 1 on at low speed. Press a second time to turn
pump to high speed (with dual speed pump). A third time to turn off. A built
in timer automatically turns pump off after a predetermined period of time,
unless pump has been manually shut off.
The “pump 1” indicator lights up when pump 1 is on. With dual speed
pump, indicator will flash when pump 1 is on at low speed.
Light Key
Key2
Press Light key to turn light on. Press a second time to turn light off. A
built in timer automatically turns light off unless it has been done
2pump orsinglepump/blower
Twopumpsystem
The “light” indicator lights up when light is on.
Up / Down Keys
Use up/down key to set desired water temperature. The temperature setting
will be displayed for 5 seconds to confirm new selection.
The “Set Point” icon indicates that the display shows the de-
The“pump2”indicatorlightsupwhenPump2ison.Withdual
sired temperature, NOT the current water temperature!
This mode allows you to stop all outputs for 30 minutes to perform a quick
spa maintenance.
Press and hold Key 1 key for 5 seconds to activate the Off mode. Quick
press Key 1 key to reactivate the system before the expiration of 30 minutes.
While the off mode is engaged, the display will toggle between OFF and the
water temperature.
Setting the Temperature Display Units
Quick press Light key again.
The display will show either °F or °C
Use Up or Down key to change units.
Press Light key a last time to go back to normal mode.
°F = Fahrenheit
°C = Celsius
24
O
PERATION SYSTEMS
Programming the filter cycles
When a filter cycle begins, pump 1 will turn on high speed for one minute to purge the plumbing. After the
minute has elapsed, pump 1 will run on low speed for the duration of the cycle, filtering and pumping ozone
into the water.
- 200 S
Setting filter cycle duration
Press and hold Light key until the display shows dxx, with “xx” representing
the duration in hours. (default: 2 hours)
Use Up or Down key to change setting.
0 = no filtration
24 = continuous filtration
Note: it is not recommended to set this to “0”.
ERIES CONTROL
Filter cycle frequency
This function tells the electronic control center how many times a day you
would like it to run the filter duration. It essentially is multiplying the filter
duration by however many units of frequency that you choose. Exampleduration=6, frequency=2, the spa will run two filter cycles, each having a
duration of six hours, for a total of twelve hours per 24 hour period. The
control center will not allow you to enter any combination equaling more
than 24 hours. To set the frequency:
Press Light key again. The display will show Fx, with “x” representing the
number of filter cycles per day (up to 4). (default twice a day)
Use Up or Down key to change setting.
When the desired setting is displayed, press Light key to confirm. A filter
cycle will start up immediately.
The “Filter” indicator light lights up when a filter cycle is on.
In a regulation cycle, the system first generates water flow through the heater housing and
the plumbing, in order to ensure accurate water temperature readings as well as avoiding
heater activation in dry conditions.
After verifying pump activation and taking a
water temperature reading, if required, the
system automatically turns the heater on to
reach and maintain water temperature at Set
Point.
The “Heater” indicator lights up when
the heater in on. It flashes when there is
a request for more heat but the heater has
not yet started.
Troubleshooting
Hr
An internal hardware error has been detected in in.xe.
Contact dealer or service supplier.
HL
The system has shut the heater down because the water temperature at the heater has
reached 119°F (48°C). Do not enter the water! Remove the spa cover and allow the water
to cool down, then shut power off and power your spa up again to reset the temperature.
Smart Winter Mode
Our Smart Winter Mode protects your system
from the cold by turning pumps on several times
a day to prevent water from freezing in pipes.
The “Smart Winter Mode” indicator
lights up when the Smart Winter Mode
is on.
Cooldown
While performing this task, the heater is not allowed
to turn on and its icon flashes.
AOH
Temperature inside the spa skirt is too high, causing the internal temperature in the
in.xe to increase above normal limits. Open skirt and wait until error clears.
FLO
The system does not detect any water flow while the primary pump is running. Check and
open water valves. Check for water level. Clean filter. If the problem persists, call dealer
or service supplier.
Prr
A problem is detected with the temperature probe. Call your dealer or service supplier.
OH
The water temperature in the spa has reached 108°F (42°C). Do not enter the water!
Remove the spa cover and allow the water to cool down to a lower temperature. Call
your dealer or service supplier if problem persists.
W
ATER CHEMISTRY GUIDELINES
WATER CHEMISTRY MAINTENANCE
P
H C
ONTROL
C
1. THE
2. T
3. T
THE
:
HEMICALLY BALANCED WATER DEPENDS PRIMARILY ON
AMOUNT OF ACID OR BASE IN THE WATER (P
HOSE CHEMICALS THAT HELP MAINTAIN OR STABILIZE P
HOSE CHEMICALS THAT CAUSE SCALING (CALCIUM HARDNESS
OF RELATIVE ACIDITY OR ALKALINITY OF WATER, PH IS MEASURED ON A NUMBER SCALE FROM
MID-POINT
SIVELY GREATER AND BELOW WHICH ACIDITY BECOMES PROGRESSIVELY GREATER
SPA WATER SHOULD HAVE A PH BETWEEN
OPTIMUM RANGE OF
CHEMICALS AND FILTERING FUNCTIONS WILL BE MOST EFFECTIVE
MEASURE THE PH AND SHOULD BE REPLACED ON AN AT LEAST ANNUAL BASIS TO ASSURE ACCURACY
, 7, IS
SAID TO BE PRECISELY NEUTRAL, ABOVE WHICH ALKALINITY BECOMES PROGRESS
100-400
PPM OF CALCIUM HARDNESS
D
ISINFECTION
THE
B
B
THE
T
C
REMEMBER!:
1. B
2. A
3. N
4. M
5. THE
:
HIGH TEMPERATURE AND INCREASED VELOCITY OF THE WATER, AS WELL AS THE HEAVY
BATHER LOADS, ALL CONTRIBUTE TO THE ORGANIC CONTAMINATION OF SPA WATER
TANT TO MAINTAIN AN EFFECTIVE RESIDUAL OF SANITIZING AGENT, TO SHOCK TREAT AT PERIODIC
INTERVALS AND, IF NEEDED, TO CONTROL ALGAE GROWTH
ROMINE IS THE BEST-SUITED SANITIZER FOR SPA WATER
A SWIMMING POOL SANITIZER, THE HIGH TEMPERATURES AND AERATION OF A SPA GREATLY ACCELERATE
CHLORINE LOSS
WHICH IS A POOR DISINFECTANT THAT CAUSES OFFENSIVE ODORS AND OFTEN CAUSES EYE BURN
ROMINE IS SIMILAR TO CHLORINE, ALTHOUGH IN THE FREE AND COMBINED FORM IT IS AN EFFECTIVE
SANITIZING AGENT AND CAUSES NO OFFENSIVE ODOR OR EYE BURN
BROMINE RESIDUAL THAN CHLORINE AND IT IS EFFECTIVE OVER A WIDER PH RANGE THAN CHLORINE
LOAD, AMOUNT OF USAGE, TYPE OF WATER, ULTRAVIOLET EXPOSURE, ETC
NEEDED WILL VARY
ORGANIC CONTAMINATION NOT READILY DESTROYED BY NORMAL ADDITIONS OF THE SANITIZING AGENT
HIS IS ACCOMPLISHED BY USING A POWERFUL, LONG-LASTING OXIDIZING AGENT CAPABLE OF DESTROY
ING THE ORGANIC CONTAMINANTS SO THE SANITIZER CAN BE EFFECTIVE IN KILLING BACTERIA
THE LINE OF CHEMICALS BEING USED
GROWTH MAY BE A PROBLEM
FOR ADVICE ON THE BEST AGENT AVAILABLE TO HANDLE THIS PROBLEM
DISTRIBUTED OVER THE SURFACE OF THE WATER, OR POURED INTO THE WATER, PREFERABLY WITH THE
PUMP AND BUBBLER ON
FACTOR FOR BATHERS AND IS HELPFUL IN CONTROLLING WATER PROBLEMS
OF TESTING CHEMICAL LEVELS AND MAINTAINING THEM
. F
REE CHLORINE REACTS WITH ORGANIC MATERIALS TO FORM COMBINED CHLORINE
TEST FOR BROMINE SHOULD READ
. ON A
WEEKLY BASIS, A “SHOCK” TREATMENT SHOULD BE USED TO DESTROY
ONTACT YOUR CHEMICAL SUPPLIER FOR THE BEST “SHOCKING” AGENT IN CONJUNCTION WITH
. IF
EFORE USING CHEMICALS, READ THE LABELS AND FOLLOW DIRECTIONS CAREFULLY
LWAYS ADD THE CHEMICALS DIRECTLY TO THE SPA WATER, EITHER IN A SUITABLE FEEDER
.
EVER ADD CHEMICALS TO THE SPA WHILE PEOPLE ARE USING IT
AINTAINING TEMPERATURE BETWEEN
BOTTOM LINE TO PROPER WATER MAINTENANCE IS TO ADHERE TO A REGULAR SCHEDULE
26
7.2-7.8, A
. FOR
SPAS INSTALLED OUTSIDE AND DIRECTLY IN SUNLIGHT, ALGAE
THIS OCCURS
:
H),
H (
TOTAL ALKALINITY) AND
). D
ESCRIBED AS A MEASURE
,
0 - 14.
. P
ROPERLY BALANCED
TOTAL ALKALINITY OF
. W
ITHIN THESE LIMITS, YOUR SANITIZING
. T
75-150
EST KITS ARE AVAILABLE TO
PPM AND AN
. IT IS
VERY IMPOR
.
. A
LTHOUGH CHLORINE IS POPULAR AS
.
. IT IS
1
PPM IN A RESIDENTIAL SPA
EASIER TO MAINTAIN A
. D
EPENDING UPON BATHER
.,
THE AMOUNT OF CHEMICALS
.
,
CONTACT YOUR RETAILER OR CHEMICAL MANUFACTURER
.
.
.
95-104°F (35-40°C) IS
ESSENTIAL AS A HEALTH
.
.
.
,
.
.
,
W
ATER CHEMISTRY GUIDELINES
(
CONT’D
27
.)
WATER CHEMISTRY MAINTENANCE
O
ZONE
Y
16-24-
1. T
2. A
3.
:
OUR SPA IS EQUIPPED WITH OZONE AS THE SANITIZING AGENT
OFFERS A “HANDS-FREE” ROUTINE TO SPA WATER CARE
MAY BE NEEDED AFTER HEAVY BATHER LOADS
BE NEEDED LESS FREQUENTLY, AND THE BROMINE ODOR NO LONGER AN ISSUE
HOUR CIRCULATION IS REQUIRED TO EFFECTIVELY SANITIZE THE WATER, AND A CHLORINE SHOCK
USED PERIODICALLY
HERE IS NO TEST KIT AVAILABLE TO TEST OZONE PRESENCE IN SPA WATER, ALTHOUGH A
CIRCULATION PERIOD IS RECOMMENDED FOR CLEAN, CLEAR WATER
SMELL WILL BE PRESENT WHEN YOU OPEN YOUR SPA COVER AS AN INDICATOR THAT THE OZONE
IS DOING IT’S JOB
PROPER PH MUST BE MAINTAINED AND A ROUTINE BROMINE OR CHLORINE SHOCK IS SUGGESTED
THE OZONE SYSTEM WITH YOUR SPA HAS AN EVERLITE INDICATOR MOUNTED ON THE CORNER OF THE
SPA CABINET
BE LIT WHEN UNIT IS IN FILTRATION CYCLE
FURTHER INSTRUCTIONS
. T
. C
ONTACT YOUR CHEMICAL SUPPLIER FOR MORE INFORMATION
.
HIS EMITS A BLUE LIGHT WHEN THE OZONE UNIT IS FUNCTIONING
.
O
ZONE UNIT
Location varies with spa model.
Refer to specifications for
location and take note during
installation positioning.
(cont’d.)
. T
HIS UTILIZES ULTRAVIOLET LIGHT AND
. THE PH
. W
ITH THE USE OF OZONE, THE PERIODIC DRAINING MAY
. R
EFER TO CONTOL INFORMATION AND ICON CHART FOR
MUST BE MAINTAINED AND SHOCKING
. IT IS
SUGGESTED THAT
.
. A
CLEAN
, “
. E
VERLITE WILL ONLY
24-
HOUR
AFTER RAIN
”
.
PROBLEM
Green Algae
Black Algae
Unpleasant Odor,
Burning Eyes
Colored Water
Hard Water
BASIC WATER CHEMISTRY CHART
Green Water
DESCRIPTION
Green spots on surface
Slippery surface
Black spots on spa surface
Chlorine-like odor.
Burning sensation in eyes.
Water in newly-filled spa turns
black, blue, or brown when
treated with ozone
Cloudy water
Scaling
Low ozone, bromine, or chlorine levels
CAUSE
Low algaecide levels
Low oxidizer levels
Low algaecide levels.
Combined chlorine and/or pH out of
balance
Copper, iron, or manganese in water
being oxidized by chlorine or ozone
Excessive hardness of makeup water or
building up of dissolved minerals in the
water caused by continued use of spa
chemicals.
Adjust pH to 7.2-7.6
Run filter continuously
Vacuum settled material
Use sequestering agent for
prevention
Clean filter
Filter continuously
Adjust pH to 7.2-7.6
Use scale inhibitor
Dilute with makeup water
28
M
AINTENANCE
R
ECOMMENDATIONS
T
ESTING THE
G
USE BY THE HOMEOWNER
PANEL BOX OR ON THE POWER CORD
SHOULD RETURN TO NORMAL OPERATION
OF ELECTRICAL SHOCK
D
IDENTIFICATION AND CORRECTION OF THE PROBLEM
G.F.C.I. (
ROUND FAULT CIRCUIT INTERRUPTER
EQUIVALENT
. W
ITH THE SPA IN OPERATION, PUSH THE “TEST” BUTTON ON THE
RCD
. THE
. IF
FOE EXPORT INSTALLATIONS
(G.F.C.I.)
SPA SHOULD SHUT DOWN IMMEDIATELY
THE
G.F.C.I.
PROTECTION FOR THE SPA SHOULD BE TESTED PRIOR TO EACH
FAILS TO OPERATE IN THIS MANNER, THERE EXISTS A POSSIBILITY
.
ISCONTINUE SPA OPERATION BY DISCONNECTING THE POWER SOURCE AND NOTIFY A QUALIFIED ELECTRICIAN FOR
.
THE SPA S
TO
BING ALCOHOL
CLEANSER, CONSULT YOUR DEALER
URFACE
PRESERVE THE SHEEN OF YOUR SPA’S SURFACE, CLEAN AND SANITIZE THE POLYETHYLENE SURFACE WITH RUB-
. A
VOID USING ABRASIVE CLEANSERS
. DO
NOT USE SOAP, AS IT CAN CAUSE SUDSING
. IF
YOU ARE NOT CERTAIN AS TO THE SUITABILITY OF A PARTICULAR
P
ERMA-WOOD CABINET
Y
AND VIRTUALLY MAINTENANCE-FREE
OUR SPA MAY BE CONSTRUCTED FROM A WOOD ALTERNATIVE MATERIAL DESIGNED TO BE DURABLE, TOUGH
:
. IT
MAY REQUIRE PERIODIC CLEANING WITH A NON-ABRASIVE CLEANER
THE C
U
YOUR OPERATING COSTS, HEAT-UP TIME AND MAINTENANCE REQUIREMENTS
IT WITH CARE AND CLEAN IT REGULARLY USING MILD SOAP AND WATER
TIONER WILL HELP PROTECT AGAINST DETERIORATION CAUSED BY
STAND OR SIT ON THE COVER, AND AVOID DRAGGING IT ACROSS ROUGH SURFACES
OVER
SING THE OPTIONAL INSULATING SPA COVER ANYTIME THE SPA IS NOT IN USE WILL SIGNIFICANTLY REDUCE
. TO
. P
ERIODIC TREATMENTS WITH A VINYL CONDI-
UV
RAYS FROM THE SUN
THE F
ILTER
(
SPA
WATER FILTRATION BEGINS AS SOON AS THE FLOW IS STEADY THROUGH THE PUMP
MUM CLEANING CAPACITY
CAUSE A RESISTANCE TO FLOW
MENT AS NOTED BELOW
2. R
3. L
4. R
5. R
6. P
7. P
SKIM FILTER SYSTEM
. AS
. W
1. S
HUT OFF POWER AT THE MAIN OR SUB PANEL
EMOVE THE FILTER HOUSING TOP BY USING THE RAISED PORTIONS OF THE FILTER TOP AND TURNING IT
COUNTER CLOCKWISE
IFT THE SKIMMER BASKET OUT OF THE FILTER CANISTER
EMOVE THE FILTER FROM THE CANISTER
EPLACE WITH CLEAN FILTER
LACE SKIMMER BASKET BACK IN FILTER CANISTER
LACE FILTER TOP ONTO FILTER CANISTER AND TURN CLOCKWISE UNTIL TOP STOPS
.
. A
.
)
THE FILTER CARTRIDGE REMOVES DIRT FROM THE WATER, THE ACCUMULATED DEBRIS WILL
HEN THIS IS NOTICED, ALONG WITH CLOUDY WATER, CLEAN OR REPLACE THE FILTER ELE-
.
FTER TOP STOPS TURNING, LIFT UP TO REMOVE TOP FROM FILTER
.
.
( R
EVIEW ABOVE FOR CLEANING RECOMMENDATIONS
.
)
G.F.C.I.
. NOW
RESET THE
.
PROLONG THE LIFE OF THE COVER, HANDLE
. N
. K
EEP COVER LOCKED WHEN NOT IN USE
. THE
BREAKER AT THE
G.F.C.I. THE
SPA
,
.
EVER ALLOW ANYONE TO
SKIM FILTER ASSURES OPTI-
.
.)
.
.
29
M
AINTENANCE
P
ERIODIC SPA WATER DRAINING
A
NATE ODORS IN THE SPA
ALLY, DEPENDING UPON BATHER LOAD AND WATER CHEMISTRY MAINTENANCE, THIS MAY NEED DONE EVERY
MONTHS
1. R
2. T
3. C
4. C
5. F
FTER A CERTAIN TIME, YOU MAY FIND THAT THE ADDITION OF CHEMICALS WILL NOT CLARIFY OR ELIMI-
. W
ITH THE USE OF OZONE, THIS MAY NEED DONE LESS FREQUENTLY
R
ECOMMENDATIONS
. T
HIS IS AN INDICATION THAT THE WATER NEEDS TO BE DRAINED AND REPLACED
.
EDUCE SET TEMPERATURE TO
URN OFF ALL POWER
LEAN CARTRIDGE FILTER AS NOTED PREVIOUSLY IN THIS SECTION REGARDING
MAINTENANCE RECOMMENDATIONS
LEAN SPA SHELL WITH NON-SUDSING CLEANSER
OLLOW INSTRUCTION UNDER START-UP
.
59˚F (15˚C).
.
.
.
. G
ENER-
3
P
LUMBING CARE
ALL
PLASTIC PARTS AND THEIR MANY GLUE JOINTS ARE SUBJECTED TO HARSH TREATMENT
WATER TO ASSURE THERE ARE NO LEAKS WHEN IT LEAVES THE FACTORY; HOWEVER, SOMETIMES SPAS DEVELOP A
LEAK CAUSED BY SHIPPING VIBRATION
AND THE HIGH PRESSURE GENERATED BY THE POWERFUL JET PUMP, WHICH TOGETHER STRESSES THE PIPES AND
JOINTS
. S
MART SPAS ARE DESIGNED TO BE OWNER SERVICEABLE WITH EASY-ACCESS PANELS ON ALL
THE PORTABLE SPA WHICH ALLOW QUICK AND THOROUGH INSPECTION AND REPAIR OF THE PLUMBING SYSTEM
S
HOULD A LEAK OCCUR, FOLLOW THESE INSTRUCTION TO MAKE THE REPAIR
1. R
2. T
3. C
R
EPLACING THE LIGHT BULB
IF
REPLACE IT
BE
SURE THE POWER IS “OFF
PULL THE OLD BULB FROM THE HOUSING AND INSERT NEW ONE
R
EPLACE CABINET PANEL AND ENDS
(SEE
THE UNDERWATER LIGHT BULB SHOULD BURN OUT YOU WILL NEED TO REMOVE THE ACCESS PANEL TO
.
ILLUSTRATIONS
SPAS ARE PLUMBED WITH PLASTIC JETS, PIPES AND FITTINGS WHICH ARE GLUED TOGETHER
. E
VERY SPA IS TESTED WITH
. O
VER THE YEARS, YOUR SPA IS SUBJECTED TO MANY HOT-COLD CYCLES
EMOVE SIDE PANEL TO LOCATE LEAK
URN OFF ALL POWER
ONTACT QUALIFIED SERVICE TECHNICIAN TO REPAIR PLUMBING
. D
RAIN SPA BELOW LEAK, ALLOW PLASTIC PARTS TO DRY
. M
ARK THE LEAK WITH A MARKING PEN
.
.
.
(R
EFER TO THE MANUAL SECTION REGARDING REMOVAL
”. L
OCATE THE LIGHT HOUSING, REMOVE FROM SPA SHELL
.
)
).
. TO
REPLACE THE BULB
. RE-
ATTACH THE LIGHT HOUSING TO SPA SHELL
. T
4
SIDES OF
.
HESE
.
,
.
W
INTERIZING YOUR HOT TUB
30
IF
FREEZING EXISTS, CERTAIN PRECAUTIONS SHOULD BE TAKEN TO AVOID DAMAGE
CYCLE, AND USE OF A RIGID FOAM COVER ARE SUGGESTED
YOUR SPA IS TO BE USED DURING THE WINTER MONTHS IN COLD CLIMATE WHERE THE DANGER OF
. AN
INCREASED CIRCULATION
. C
ONTACT YOUR DEALER FOR ADVICE
.
M
TAINLY SUGGESTS THE USE OF A SPA YEAR-ROUND, ALTHOUGH CERTAIN SITUATIONS DO REQUIRE CLOSING THE
UNIT FOR THE WINTER MONTHS (I.E.,VACATION HOMES
PERFORM THE FOLLOWING WINTERIZING PROCEDURES
ANY SPA OWNERS FIND THAT OUTDOOR WINTERTIME SOAKING IS QUITE ENJOYABLE, AND SMART CER-
). IF
THE SPA WILL NOT BE USED FOR A PERIOD OF TIME
,
:
1. T
URN HEAT ALL THE WAY DOWN AND TURN OFF AT THE BREAKER
.
2. D
RAIN SPA OF ALL WATER
.
3. R
EMOVE ANY REMAINING WATER WITH SPONGE
.
4. F
ILTER SHOULD BE DRAINED, REMOVED AND CLEANED
. S
TORE IN A DRY PLACE
.
5. P
UMP, MOTOR AND ALL CONNECTING LINES SHOULD BE DRAINED FULLY TO PROTECT
FROM FREEZING
WATER
. YOU
GUARANTEE FREEZE PREVENTION
INSTRUCTIONS AND REMOVE ALL ANTI-FREEZE BEFORE THE NEXT SPA USE
. B
LOW AIR THROUGH ALL CONNECTION LINES TO REMOVE
MAY WISH TO USE A NON-TOXIC
. BE
SURE TO READ THE MANUFACTURER’S
RV
TYPE ANTIFREEZE TO
6. C
OVER THE SPA WITH A WATERPROOF RIGID COVER TO PROTECT IT FROM SNOW, ICE
AND WIND
.
.
T
ROUBLESHOOTING
31
A
IF
ANYTHING LOOKS BROKEN, WORN, OR INCORRECT, CONTACT YOUR ELECTRICIAN OR SPA RETAILER
REPAIR MAY PREVENT AN INJURY OR MORE SERIOUS PROBLEMS REQUIRING EXPENSIVE REPAIRS
NOT OPERATING, CHECK THE FOLLOWING
GOOD GENERAL RULE IS TO VISUALLY INSPECT YOUR SPA AND EQUIPMENT AREA FREQUENTLY
. IF
:
1. ALL
• C
• C
• C
• C
EQUIPMENT IS IN-OPERATIVE
HECK POWER SOURCE
HECK TO ASSURE SPA HAS DEDICATED CIRCUIT
HECK THE “TEST” AND “RESET” BUTTONS ON
HECK INTERNAL FUSES
G.F.C.I.
.
BREAKER
. (OR
EQUIVALENT
.
G.F.C.I. (OR
)
EQUIVALENT
)
2. P
• C
• C
• C
• P
UMP DOES NOT WORK
HECK ALL ITEMS ABOVE
HECK FILTER; CLEAN OR REPLACE CARTRIDGE
HECK FOR BLOCKAGES (RESTRICTIONS) AT SUCTIONS, SKIM FILTER AND PUMP
USH “PUMP” BUTTON(S) TO CHECK IF HIGH SPEED IS FUNCTIONING, ON A DUAL-SPEED PUMP
.
.
3. I
• M
• M
• C
• C
• P
NADEQUATE JET ACTION
AKE SURE JETS ARE TURNED ON
AKE SURE AIR CONTROLS ARE OPEN
HECK FOR RESTRICTIONS (BLOCKAGES) IN JETS AND/OR MAIN SKIMMER AND PUMP
HECK WATER LEVEL
USH “PUMP” BUTTON(S) TO CHECK IF HIGH SPEED IS FUNCTIONING ON A DUAL-SPEED PUMP
.
.
.
4. NO
• C
• C
• C
• C
• C
HEAT
HECK ALL STEPS UNDER PART
HECK TEMPERATURE SETTINGS
HECK FOR CLOGGED FILTER ELEMENT AND OTHER RESTRICTIONS
HECK WATER LEVEL
HECK IF PUMP IS RUNNING
.
“1”.
.
.
.
5. NO
• C
• C
LIGHT
HECK “LIGHT” BUTTON
HECK
G.F.C.I. (OR
.
EQUIVALENT
) “
TEST” AND “RESET” BUTTONS
.
6. W
• I
• T
• C
ATER IS CLOUDY
NCREASE CIRCULATION CYCLE
EST WATER CHEMISTRY
LEAN/REPLACE FILTER CARTRIDGE
.
.
.
7. P
• T
UMPS HAVE STARTED FOR
HIS IS A FEATURE OF THE SMART WINTER MODE PROTECTING YOUR SPA FROM THE COLD BY
TURNING PUMPS ON FOR
1
MINUTE SEVERAL TIMES
1
MINUTE SEVERAL TIMES A DAY TO PREVENT FREEZING IN PIPES
IF