CONGRATULATIONS!
You’ve just purchased the highest quality powerline-controllable wall switch available. SwitchLinc Lite
gives you remote control of lighting and inductive loads, and can be controlled locally at the switch or
remotely from a powerline transmitter.
SwitchLinc Lite is easily installed and programmed. It installs (connects to home wiring) just like a
regular light switch. This makes it ideal for retrofits and easy for new homes, with no special training
required to install it.
KEYFEATURES
• Wires in just like a standard wall switch*
• Very easy to program
• High quality mechanicals with years of field testing
• True rocker action (top = on/bright, bottom = off/dim)
• LED “Bar” shows brightness of circuit
• Status LED shows powerline activity and is a “nightlight”
• Set Button facilitates programming
* Requires a neutral connection
SWITCHLINC LITE MODELS
Model # 2384W/I - 600 Watt Master (White or Ivory)
Model # 1135W/I - “Slave” Switch for 3-Way, 4-Way, & Up (White or Ivory)
(Note: 1135 does not have LED brightness bar.)
OPERATIONS
Input at Switch Output at Bulb
Tap top of rocker (when light is off) Light ramps up to preset ON-level
Tap top of rocker (when light is on) Light ramps up to full brightness
Double-tap top of rocker Light ramps fast to full brightness
Press & hold top of rocker Light brightens until rocker is released
Tap bottom of rocker Light ramps down to OFF
Double-tap bottom of rocker Light ramps fast to OFF
Press & hold bottom of rocker Light dims until rocker is released
LED
Operation
Status LED/Nightlight Blinks when valid X-10 signals are received
Brightness LED “Bar” (8 LEDs) Illuminated LED represents current brightness
setting (Top = Brightest; Bottom = Dimmest)
2
Brightness LED Bar
Status LED/Nightlight
Set Button
CAUTION!!
Read and understand these instructions before installing. This device is intended for instal-
lation in accordance with the National Electrical Code and local regulations. To reduce the
risk of overheating and possible damage to other equipment, do not install a SwitchLinc to
control a receptacle or fluorescent lighting fixture. For indoor use only. Connect only copper or copper-clad wire to this device. Before installing control, disconnect power at circuit
breaker or remove fuse to avoid shock or damage to the control. It is recommended that a
qualified electrician perform this installation. Retain these instructions for future reference.
SPECIFICATIONS
• Load types: permanently installed incandescent and general inductive loads
• Single pole or multi-location (with Slave Dimmers)
• Operation: Dimming Triac
• Maximum load: 600 watts / 600 VA
• Input power: 125 VAC, 5 amps, 60 Hz
• Connections (16 AWG): Black (to line)
• Addresses: 1 PLC (X-10) Base (Primary) Address of 256 possible
• On-Level: 1 of 31 possible (3.2%-100%) or resume dim
• Ramp Rate: 0.125 seconds to 9 seconds
• Maximum number of SwitchLincs per multiple-gang box: 4
• Maximum number of SwitchLincs per circuit: 10 (with more than 6, a PLC amplified
coupler-repeater is highly recommended)
• Minimum load: 40W
• Operating temperature range: -40
• Minimum PLC transmit level: 2V
• Minimum PLC receive level: 10mV
• Maximum PLC signal rejection: 200mV
• Mounts in single or multiple-ganged J-box
(Note:When 2 units are ganged together, use no more than a 500 watt load on each unit;
when 3 or more units are ganged together, use no more than a 400 watt load on each unit.
To avoid downgrading load control, use a larger box than needed to create space between
the switches.)
• Nightlight indicator: Green LED
• Brightness indicator: 8 Green LEDs
• Dimensions - 4” x 1 11/16” x 1 7/8”
• Weight - 4 oz.
• Programming can be disabled (locked out)
• Switch can be physically disabled (and a hard “reboot” achieved) by a
firm OFF press
• U.L. Listed for use in the U.S. and Canada
Dimming an inductive load (such as a ceiling fan) below the minimum voltage set by the
manufacturer of the load device could cause damage to the load device from overheating.
If the manufacturer of the load device does not recommend dimming, DO NOT use Switch-
Linc Lite with that device. USER ASSUMES ALLRISKS ASSOCIATED WITH DIM-
MINGAN INDUCTIVE LOAD.