![](/html/44/4406/44066fc336457247a8ed86a6c2d924cda814fa66fdaf748a4700ba836cdafc89/bg1.png)
Quick-Start Guide
TriggerLinc
TM
TriggerLinc
Main Case
LED
INSTEON Door/Window, Open/Close Sensor
Models: #2421
The TriggerLinc INSTEON Open/Close sensor is a wireless, battery operated, magnetic contact closure sensor. You
can optionally connect an external contact closure sensor of any type (e.g. Hidden contacts or Doorbell button)
Required: Access Point
TriggerLinc requires at least one INSTEON Access Point (#2443) product installed in your home, however two are strongly
recommended.
1) Remove cover of the TriggerLinc main case by using a small screwdriver, and install 1 AA battery (included)
2) Unless the location of where you plan to mount the TriggerLinc is in direct view of the LED on an Access Point, have a
1
For Multi-button responders (e.g. KeypadLinc) tap the button you wish to control before Pressing & holding its Set button.
friend look at the LED on an Access Point before starting the next step.
3) In the location where you intend to mount the TriggerLinc, tap the TriggerLinc’s Set button once
4) If you don’t see the results mentioned in step 3, try tapping the TriggerLinc’s set button a few more times.
5) When mounting the TriggerLinc main case and the magnet, ensure they are as close as possible (note: magnet must be
within 1/2” for TriggerLinc to operate properly). Also, the arrows on the side of the main case and the magnet must face
each other. The included screws or double-stick tape can be used for mounting. If needed depending on the style of your
door or window frame, use some of the double stick tape beneath one of the pieces to ensure they are at the same relative
height.
6) Mount the magnet to the door or window as close to the edge as possible
7) Mount the TriggerLinc main case to the door/window trim
8) Replace TriggerLinc’s cover
1) Linking to INSTEON Responders
2) Unlinking from INSTEON Responders
FYI - TriggerLinc’s LED will not turn on
TriggerLinc’s LED will flash once
Access Point’s LED will flash once or quickly flash twice. Both confirm the device with within RF range
a. If the TriggerLinc’s LED still doesn’t flash, try another battery. If still doesn’t work, call tech support @ 1-800-
SMARTHOME (800-762-7846)
b. If the TriggerLinc’s LED flashes, but the Access Point’s LED doesn’t flash, try moving the Access Point other
locations or add another Access Point if only one is installed. If still doesn’t work, call tech support @ 1-800SMARTHOME (800-762-7846)
a. Press & hold the Set button on TriggerLinc for 5 seconds (until the red LED begins blinking, you now have 4 minutes to complete step b)
b. Press & hold Set button
c. Test by tapping the TriggerLinc’s Set button
d. Repeat this procedure for up to 32 responders
a. Press & hold the Set button on TriggerLinc for 5 seconds and release
b. Press & hold the Set button on TriggerLinc for an additional 5 seconds
c. Press & hold Set button on INSTEON responder you would like to unlink (until its LED blinks)
d. Test by tapping the TriggerLinc’s Set button. Taps should no longer control the unlinked device.
TriggerLinc’s LED will begin blinking
the connected load/bulb may flash)
TriggerLinc’s LED will stop blinking (if not, try step 1-b again)
i. Each tap should alternatively turn the linked Responder(s) on and off
LED will flash each time Set button is tapped
TriggerLinc’s LED will begin blinking
TriggerLinc’s LED will begin reverse blinking (LED will be more on than off)
TriggerLinc’s LED will stop blinking (if not, try step 2-c again)
TriggerLinc’s LED will flash each time Set button is tapped
Introduction
Arrows indicating to line up main
Installation
Operation
1
for 5 seconds on the INSTEON responder (e.g. SwitchLinc) you would like the TriggerLinc to control (an LED may blink and
case with magnet
Jumper
Set Button
Magnet
External Sensor
Terminals
Page 1 of 1
Rev. 111408
![](/html/44/4406/44066fc336457247a8ed86a6c2d924cda814fa66fdaf748a4700ba836cdafc89/bg2.png)
By default TriggerLinc will turn a Scene On when sensor is opened and Off when the door/window is closed. Alternatively, by moving the jumper to the “off” position,
TriggerLinc can send an On to “Scene 1” when the door/window opens and an Off to “Scene 2” when the door/window closes.
1) Remove jumper (from both pins) and replace on only one pin
2) Open door/window
3) Link to Scene 1 Responders (s) (these responders will turn on when door/window is opened)
4) Close door/window
5) Link to Scene 2 device(s) (these responders will turn off when door/window is closed)
Advanced: Multi-Scene Control
1) Remove cover on TriggerLinc main case
2) Connect wires to sensor
3) Store magnet for potential future use
Optional: Wired Sensor
1) If possible, unlink from all responders before proceeding
2) Remove battery
3) Wait 15 seconds
4) While pressing & holding the Set button, re-attach the battery and continue holding the Set button for 3 seconds until the LED turns on for a few seconds.
TriggerLinc’s LED will turn on for a few seconds and then turn off
Factory Reset
For HELP, call our friendly tech support @ 1-800-SMARTHOME (800-762-7846)
SmartLabs Limited Warranty – SmartLabs warrants to the original consumer of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and
workmanship and will perform in substantial conformity to the description of the produc t in the ow ner's manual and/or quick start guide. This warranty shall not apply to defects or errors caused by misuse
or neglect. U.S. Patent No. 7,345,998, International patents pending © Copyright 2007 SmartLabs, 16542 Millikan Ave, Irvine, CA 92606-5027 – 800-762-7846 www.smartlabsinc.com
Page 2 of 1