1 1 Introduction:
(enter) +1 Exit button.
· Up to 1000 user capacity, each user owns one card and one PIN. Also it can be connected with the exit button.
· All setting can be done through infrared remote control or keypad reader if external reader is keypad one. It offers user easy operation & safe guarantee.
· Compact, economical and practical, secure and reliable, and fit for type of 86 Box installation inside of room.
· If external Reader is keypad one, then all the setting of PA240510 can be done on keypad reader.
· Using provided infrared remote control to do all the setting of PA240510.
· The door won't be opened even the external reader is damaged, or
encountered by strong magnetic or short circuit or any other illegal way.
· 1000 user capacity, apply to office, villa, household use etc.
· User information can be copied between every mini controller.
· Every user can change the password without master if external reader is
keypad one.
· Password is 4-6digits, more security.
· Wiring is very simple; can be done by users without professional knowledge;
can be connected with various electric lock and no need to change external wiring.
.
· PA240510 controls one door: 1 Reader(enter)+1 Reader(exit) or 1 Reader
2. Ins talla tion & Co nnec tion Dia gram( fit for ty pe of 8 6Bo x ins talla tion)
2.1 Installation Diagram:
3.Us er Opera tion
Stand by
Red Unlocking
Successful Fail Entering PIN Swiping card Setting Copying user information
Green
Green
RED &Green flash slow
RED &Green flash quick
RED &Green flash quick
Green
Bee-eep Bee-eep Beep Beep Beep
Power off, press exit button and power on, the LED turns into RED&GREEN flash quick, release exit button after you hear “beep, beep”. And then you hear “Bee-eep”, means reset to Factory Default successfully. But it won't delete all user information.
5.R es et to F acto ry De fault
6. S ound And L ight In dica tion
Operation Status
Color of LED
Buzzer
Note that all the following programming should be under master programming mode. When master's PIN is wrong and the time is over 5s before you enter PIN again, it will return to standby mode. After enter right master's PIN, it will also return to standby
mode if there is no valid operation in 30 seconds. Press“#” to confirm the input number, return to previous menu by press “*”, the indicator light will indicate the operation mode.
4. Mas ter Settin g
To enter the master progra mming mode
Red Green LE D flas h s low
Red Func tions Rem ark
To enter the programming mode
Factory default 888888
Func tion S ettings
Red Green LE D flas h quick
Func tions Rem ark
Red &
Green
LED flas h
slowly
6-8 digits new PIN # repeat 6~8 digits new PIN #
To change the master PIN
0
Read card
1-1000(ID),#, read card
8 or 10 digits card number #
To add card users
Rotate Operation
1
1-1000(ID), #, 4-6 digits PIN, #
To add PIN users
Read card
8 or 10 digits card number, #
1-1000(ID),#
Delete one card
Delete one user
Rotate Operation
2
0000, # (Note: This is a dangerous option, so use with care)
Delete All users
2
0, #
1, #
2, #
3
Entry is by Card only
Entry is by Card and PIN together
Entry is by either card or PIN
Factory default 2
To set door relay time 50mS
To set door relay time 1-98S
Toggle mode
0, #
99, #
1-98, #
Factory default 5s
4
0, #
1, #
Factory default 1
5
Only useful for the operation by infrared remote control
0000, #
6
Access Controller
1.3 Technical Parameters:
· Input Voltage: DC12~14V
· Idle current : ≤ 11mA
· Lock Output load: ≤ 3A
· Time of copying user information: ≤ 8s
· Wiegand input format: 4Bit or 8Bit of pressing one key, 26-37Bit virtual card No.
· Dimension: 86(H)×86(W) ×20mm(T)
· Operating Temperature: -40~60
· Operating Humidity: 0~95%(non-condensing)
2.2 W iring Diagram
+12V
GNDD0D1LED
BZ
+12V
GND_R
D0D1LED
BZ
+12V
GND
OPEN
GND
LOCK+
LOCK-
Lock
Open
Power
+12VGND
OPEN
GND
L OCK+
LOC
K-
Lock
Open
Power
Reader Reader
+
+12V
GND
D0
D1
LED
BZ
+12V
GND
OPEN
GND
LOCK+
LOCK-
+
Reader
+
Lock
Open
Power
+12V
GND
D0
D1
LED
BZ
Reader
PA 240510 Access Controller
Door Button
DC 12V
Power
Electric Lock
Figure 2:Wiring Diagram
PA 240510 Access Controller
PA 240510 Access Controller
DC 12V Power
Figure 3: Wiring of copying user information
3.1 Swiping Card to open door:
Swiping user card once , door will be opened.
3.2 Swiping Card+PIN to open door:
Swiping user card once, and enter 4-6digits PIN,# , door will be opened.
3.3 Card or PIN to open door:
Swiping user card once or enter4-6digits PIN, # , door will be opened.
3.4 Relay setting (Pulse mode and toggle mode):
Pulse mode: Everytime we swipe card or enter PIN, the door will be opened and then locked in 0-98s. This delay time can be set.
Toggle mode: Everytime we swipe card or enter PIN, the door will be opened and keep this status until we swipe card or enter PIN it will be locked, and vice versa.
3.5 Change the user's PIN
* , Swipe user card , Enter 4-6 digits old PIN,# , Enter 4-6 digits new PIN,# , Repeat Enter 4-6 digits new PIN,# Or * , Enter 1-1000(ID No.),# , Enter 4-6 digits old PIN,# , Enter 4-6 digits new PIN,# , Repeat Enter 4-6 digits new PIN,# Remarks: PIN users have to get the ID No. and initial PIN from master. Card users have to swipe card when change the PIN first time. The initial PIN is 1234, it is only for changing new PIN, can't be used to open door.
6-8 digits master's PIN #
1-1000(ID),#,8 or 10 digits card number #
Connect to A type of lock
Copy user information
Connect to B type of lock
Remark: ①Before you connect the electric lock to PA240510, make sure you already set the type of lock. A type of lock refers to those lock that normally under standby status ,there is no current for lock, when there is current the door will open.
B type of lock refers to those lock that normally under standby status, there is current for lock, when there is no curren
t the door will open.
The wiring for copying the user information, pls see figure 3. The user information can be copied from A to B or from B to A. The device should be our Mini controller, and the master's password should be the same. When the wring is done, then you can copy user information from A to B, use the infrared remote control to do it, please avoid that device B receive the signals, otherwise your operation will failed. After enter master programming mode, then followi
ng the operation “6” in the table above, the GREEN light on around 8s, meaning
information is being copying from A to B, and versa vice.
PA 240510
SmartKing
support@smartking.com www.smartking.com SKU PA240510
Loading...