SmarTap e-Valve Installation Manual

INSTALLATION GUIDE
Welcome,
Thank you for using SmarTap – an advanced digital shower system. Careful adherence to the installation procedures and maintenance practices set out in this manual will ensure many years of outstanding performance from your new shower.
Please note,
No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form by any means, electronic, mechanical, photo reproductive, recording or otherwise without the prior written permission of SmarTap Ltd.
This guide is subject to periodic review, update, and revision. Customers are cautioned to make sure that the guide’s information applies to the system they are using.
This product performs as described in this guide when assembled, operated, maintained, and repaired in accordance with the instructions provided. Do not repair this product or any of its parts other than in accordance with written instructions provided by SmarTap Ltd.
1 of 51
Table Of Contents
Table Of Contents ................................................................................ 1
Introduction .......................................................................................... 2
Important Safeguards .......................................................................... 3
Labels and Symbols ............................................................................ 6
Technical Specifications ....................................................................... 7
Package Contents ............................................................................... 8
System Dimensions & Mechanical Specifications ...............................10
Tools ...................................................................................................13
Hydraulic Characteristics ....................................................................14
Installation Options .............................................................................15
Plan System Layout ............................................................................19
Prepare for Installaiton........................................................................19
Prepare Infrastructure .........................................................................22
Connect e-Valve and Connect Pipes ..................................................30
Connect Controllers ............................................................................35
Install Power Supply ...........................................................................37
Connect Cables to e-Valve .................................................................38
Software Outlets Configuration ...........................................................41
Final Inspection ..................................................................................42
Maintenace .........................................................................................43
Troubleshooting ................................ .................................................. 46
Notices ...............................................................................................48
2 of 51
Introduction
This guide provides the information necessary to install and operate the SmarTap digital shower system in a safe and efficient manner.
Please read and understand this guide before operating the system. It is mandatory to follow the instructions in the guide and the
technical description in order to avoid damage to the system. If any part of this guide is not clear, please contact SmarTap Technical
Support at support@smartap-tech.com for clarification.
Warnings / Cautions / Notes
The manual includes several kinds of comments, marked with specific statements and aimed to attract user attention to a specific type of information.
The definitions of Warnings, Cautions and Notes used in this document are as follows:
WARNING
A WARNING HIGHLIGHTS AN ESSENTIAL OPERATING OR MAINTENANCE PROCEDURE, PRACTICE, CONDITION, STATEMENT, ETC., WHICH, IF NOT STRICTLY OBSERVED, COULD RESULT IN INJURY OR DEATH OF PERSONNEL, OR LONG TERM HEALTH HAZARDS.
CAUTION
A CAUTION HIGHLIGHTS AN ESSENTIAL OPERATING OR MAINTENANCE PROCEDURE, PRACTICE, CONDITION, STATEMENT ETC., WHICH, IF NOT STRICTLY OBSERVED, COULD RESULT IN DAMAGE TO, OR DESTRUCTION OF, EQUIPMENT OR LOSS OF EFFECTIVENESS.
NOTE
A NOTE HIGHLIGHTS OR CLARIFIES AN ESSENTIAL SYSTEM DESCRIPTION, OPERATING OR MAINTENANCE PROCEDURE, CONDITION OR STATEMENT.
3 of 51
Important Safeguards
Please read these instructions carefully before installation.
Read Instructions
All the safety and operating instructions should be read before system is unpacked and installed.
Retain Instructions
The safety and operating instructions should be retained for future reference.
Follow Instructions
All installation and configuration instructions should be followed.
WARNING
THE WARRANTY WILL BE VOID IF THE PRODUCT IS NOT INSTALLED ACCORDING TO THESE INSTRUCTIONS. SMARTAP WILL NOT BE LIABLE FOR LOSS OR DAMAGES RESULTING FROM IMPROPER INSTALLATION OR USE OF THE PRODUCT THAT IS NOT IN ACCORDANCE WITH THE INSTRUCTIONS SPECIFIED BELOW.
NOTE
THE CONTENTS OF THIS GUIDE ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.
Safety Instructions
WARNING
DO NOT USE THE E-VALVE SYSTEM BEFORE READING AND UNDERSTANDING THIS GUIDE
4 of 51
WARNING
UNAUTHORIZED MODIFICATION MAY CAUSE POOR PERFORMANCE OF THE E-VALVE. DO NOT MAKE MODIFICATIONS TO THE VALVE AS THIS COULD ADVERSELY AFFECT THE PERFORMANCE OF THE VALVE AND VOID THE WARRANTY. SMARTAP WILL NOT BE LIABLE UNDER ITS WARRANTY OR OTHERWISE FOR PERSONAL INJURY OR DAMAGE CAUSED BY AN UNAUTHORIZED MODIFICATION.
WARNING
PRODUCT MUST BE INSTALLED BY QUALIFIED AND CERTIFIED PERSONNEL, IN ACCORDANCE WITH ALL CURRENT RELEVANT STATUTES AND REGULATIONS IN YOUR COUNTRY.
WARNING
ALL SHOWERS REQUIRING AN ELECTRICAL CONNECTION MUST BE INSTALLED BY QUALIFIED PERSONEL FOLLOWING THE RELEVANT REGULATIONS IN YOUR COUNTRY AND CERTIFIED TO CURRENT BUILDING REGULATIONS.
WARNING
BEFORE ANY ELECTRICAL CONNECTIONS ARE MADE, THE ELECTRICITY SUPPLY MUST BE TURNED OFF AT THE MAINS SWITCH. ALL ELECTRICAL INSTALLATION MUST BE CARRIED OUT ONLY BY QUALIFIED PERSONNEL.
CAUTION
BE CAREFUL WHILE UNPACKING; THE SYSTEM IS FRAGILE.
5 of 51
Installation Guidelines
CAUTION
THE E-VALVE SHOULD BE INSTALLED IN AN ACCESSIBLE LOCATION FOR MAINTENANCE (AND NO WARRANTY CLAIM CAN BE CONSIDERED OR LIABILITY ACCEPTED BY SMARTAP IF LACK OF ACCESSIBILITY HAS PREVENTED MAINTENANCE).
CAUTION
THE E-VALVE MUST NOT BE INSTALLED IN PLACES WHERE EITHER THE AMBIENT TEMPERATURE IS LIKELY TO EXCEED 40°C OR WHERE FREEZING MAY OCCUR.
THE DIAL CONTROLS MUST NOT BE INSTALLED IN PLACES WHERE THE AMBIENT TEMPERATURE IS LIKELY TO FALL BELOW 5°C OR RISE ABOVE 60°C.
CAUTION
TO PREVENT DAMAGE IN THE EXISTING INFRASTRUCTURE IT IS MOST RECOMMENDED TO CHECK FOR HIDDEN PIPES OR CABLES BEFORE DRILLING ANY HOLES.
PIPES ON BOTH INLET AND OUTLETS SHOULD BE AS SHORT AS POSSIBLE IN ORDER TO AVOID REDUCTION OF FLOW RATE AT THE CONNECTED OUTLETS.
6 of 51
Labels and Symbols
The e-Valve system has the following labels and symbols.
Symbol
Description
Read the Installation manual
Manufacturer
Class III Appliance
Read all documents including the Users Guide
IPx6
IPx6 Water projected by a nozzle (6.3 mm)
against enclosure from any direction shall have
no harmful effects.
Not for general waste
CE conformity marking
7 of 51
Technical Specifications
Absolute Maximum Ratings
Working pressure
1 – 9 bar
Overpressure
16 bar
Burst pressure
35 bar
Hot water temperature
70 Co
Ambient temperature
5 – 60 Co
Relative humidity
90% non-condensing
Recommended Conditions
Working pressure
2 – 5 bar
Hot water temperature
50 – 65 oC
Cold water temperature
10 – 25 oC
Set point temperature
Cold water or 35 – 45oC
Performance at Recommended Conditions
Temperature accuracy
±0.5°C
Flow accuracy
±5% of Full Scale
Hydraulic performance
Complies with EN1111 standard
Miscellaneous
Supplied user interface
cable length
9m
Operational voltage
100 – 240V ~ 50 – 60Hz
Standards
Safety: EN 60335-1 :2012,
EN60335-2-105:2005
EMC: EN 55014-1, EN 55014-2
CE, RoHS, WRAS
WARNING
DO NOT USE THE SYSTEM IF THESE CONDITIONS ARE NOT MET.
8 of 51
Package Contents
The SmarTap Digital Shower system package includes the following components:
AC cord length: 1.5m
DC cord length: 1.5m
e-Valve
AC/DC Adaptor
9 of 51
WARNING
IF THE SYSTEM PARTS SHOW ANY KIND OF MECHANICAL DAMAGE, DO NOT USE THE SYSTEM AND CONTACT A SMARTAP REPRESENTATIVE FOR SERVICE.
Two Dial controller
(If applicable) One Dial
controller
6 pin interface cable 9 m
length
IP67 compatible
6 pin interface cable 7m
length
IP67 compatible
Two Dial controller cable
(If applicable) One Dial
controller cable
10 of 51
System Dimensions & Mechanical Specifications
e-Valve
11 of 51
Two Dial Controller
12 of 51
One Dial Controller
13 of 51
Tools
For installation of the SmarTap digital shower product, you will need the following tools:
(If Applicable) For the One Dial controller, use a 62mm hole saw.
14 of 51
Hydraulic Characteristics
Typical flow rate performance of e-Valve at various inlet and outlet conditions
0
5
10
15
20
25
30
35
40
0.5 1 1.5 2 2.5 3 3.5 4 4.5
Flow rate, mixed stream [L/min]
Dynamic pressure [bar]
Single outlet, open Single outlet, resistance class C
Two or three outlets, open
Loading...
+ 36 hidden pages