Quick Start Instructions
TL-2100G
Need Set-up Help? (800) 650-3637
AA Battery
+
-
Melody
3 2 1
Volume
Decrease/Increase
AA Battery
+
-
AA Battery
+
-
The CordLess® Monitor can work in two modes:
1. With one CordLess® bed or chair sensor pad
2. With two CordLess® bed sensor pads
Install Battery, Adjust Settings
1
Program Sensor Pad(s)
2
3
A. Test Pad 1
B. Test Pad 2
Program Button
Pad 1
Pad 2
Reset
Low Battery
Status/ In Use
Check
Pad
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Remove the protective boot. Insert batteries as shown.
CordLess Monitor settings: Volume, Melody
Close the battery door and secure it with the small Phillips-head screw.
Place the monitor in its protective plastic boot.
Resetting the Monitor/Tamper Proof™ Mode with Caregiver Key
(Optional)
Test the System for each Pad
Caregivers can choose to reset the CordLess Monitor in either of two ways:
Option 2 allows only the caregiver to reset the monitor.
For more informati on about the Care giver Key a nd how it c an be use d in your f acility ’s Fall R isk Assess ment Program call 800-650-3637
IMPORTANT: W hen using the
TL-2100G CordLess® Monitor with two pads, place all the components (the two pads and the monitor) within 15 feet of each other. Test the system before each use.
When using “Reset Button ON” Mode
Press the Reset/Low Battery button to reset the monitor.
When using “Reset Button OFF”
Place the Caregiver Key over the red dot to reset the monitor.
Alert Tone/Melody Adjustment
Default Setting: Melody 1
Alert Volume Dial
Default Setting: Full Volume
Reset Button
Monitor ready to
program
Pad 1
Monitor ready to
program Pad 2
Exit Programming for single pad use
Program 2nd pad
Option 1
OR
Option 2
SMART CAREGI VER CORPORATION
Tel: 80 0-650-3637 | www.smart caregivercorp.com
Reset
Low Battery
PR
OGR
A
M
TL-200GU R2
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Reset
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
(See separa te instruction s for Co rdLess® Floor M at opera tion)
Place one or two CordLess bed or chair pads within reach. Each sensor pad comes with a CordLess Transmitter connected and turned on.
Press and hold the Program Button on the back of the monitor until you hear 3 short beeps to enter programming mode. Release the button.
Press and hold t he Program
Button until yo u hear 3 short
beeps to enter program ing
mode.
Apply pressure to pad
Monitor will beep two times
Status light will blink while pressure remains on pad
When pressure is removed, monitor will alarm
Press reset button to silence alarm or use caregiver key depending on your setting.
See switch on side of monitor to select the option of your choice.
“Reset Switch ON”: Pressing the
Reset/Low Battery button on the front of the monitor.
“Reset Switch OFF”: Placing the
optional Caregiver Key over the red dot on the front of the monitor.
Reset
Reset
Reset
Reset
Reset
0.3A
Place pressure on rst
pad for 3 seconds,
then release to
program as Pad 1.
Monitor beeps twice.
Place pressure on second pad for 3
seconds then release to program as
Pad 2. Monitor beeps twice.
Press the Reset Button to
exit programming.
*NOTE: When there are 2 pads programmed to the monitor and no one is on the pads, press the reset button twice to reset the monitor.
Place pressure o n
program as Pad 1.
Monitor will beep
twice.
CordLess® Fall/Mobility Monitor TL-2100G
Need Set-up Help? (800) 650-3637
CAUTIO N: If using this monitor with Change Pad Indicator™ Timed Sensor Pads, this monitor will not indicate when pad life has expired. Pads will still function normally. Call (800) 650-3637 for more information.
WARNING: Failure to comply with warning may result in injury or death. This device is not suitable for all individuals. Other devices may be required. This device is not a substitute for visual monitoring by caregiver. The manufacturer does not claim that this device will stop elopement and/or stop falls. This device is designed to augment caregivers’ comprehensive resident mobility management program. Test this device before each use. Read
the instructions and Legal Disclaimer.
The Smart Caregiver Corporation TL-2100G CordLess® Monitor is designed to be installed by the end user. As such, it is the entire responsibility of the buyer to insure that the system is properly in
stalled and tested. Further, the system is not designed to replace good caregivi gn
practices including, but n
ot limited to:
A.) Direc t patient supervision
C.) Testing of the sys tem before each use
WHERE PERMISSIBLE, IT IS THE SELLER’S INTENT TO LIMIT ANY LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL ECONOMIC DAMAGES TO REFUND OF THE PURCHASE PRICE OR REPLACEMENT OF THE GOODS. SELLER DISCLAIMS ANY LIABILITY FOR COMPENSATORY OR OTHER DAMAGES ARISING OUT OF THE USE OF THE GOODS.
WARNING: The manufacturer does not claim that this device will stop elopement and/or stop falls. This device is designed to augment caregivers’ comprehensive resident mobility management program. This product is to be used by a licensed caregiver only.
Limited Warranty: Seller warrants that the goods sold will be free from defects of workmanship and manufacturing, for a period of one year from the date of sale. Other than this limited warranty, seller makes no express or implied warranties. Except for this limited warranty, NO EXPRESS OR IMPLIED WARRANTIES ARE GIVEN AND NO AFFIRMATION OF SELLER, BY WORDS OR ACTION, WILL CONSTITUTE A WARRANTY. THE GOODS BEING PURCHASED ARE BEING SOLD ON
A “WITH ALL FAULTS” BASIS. THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE GOODS IS WITH THE BUYER. SHOULD THE GOODS PROVE DEFECTIVE F OLLOWING THEIR PURCHASE, THE BUYER, AND NOT THE MANUFACTURER, DISTRIBUTOR OR RETAILER, ASSUMES THE ENTIRE COST OF ALL NECESSARY INSTALLATION, SERVICING OR REPAIRS.
SMART CAREGIVER CORPORATION
1229 Nort h McDowell Blvd., Petaluma, CA. 94954 | Tel: 800-650-3 637 sales@smartca regivercorp.com | www.smartca regiver
corp.com
CordLess® Bed Sensor Pads
TEST THE SYSTEM
Apply pressure to the pad to activate system. The Monitor will beep twice when activated. The Pad 1 or Pad 2 light on the front of monitor will blink as long as there is pressure on Pad 1 or Pad 2, respectively.
The alert will sound whenever pressure is released from pad. Press the “Reset button on front of monitor or use the Caregiver Key, depending on your reset setting to silence the alert.
If the Pad Lost light is on and system does not test properly, reduce the
distance between the monitor and the pad. Retest.
BED PAD PLACEMENT
Place the pad under shoulders to be alerted when the resident sits up in bed .
Place pad under the hips/buttocks to be alerted when the resident vacates the bed
.
CordLess® Chair Sensor Pads
TEST THE SYSTEM
Apply pressure to the pad to activate system. The Monitor will beep twice when activated. The Pad 1 or Pad 2 light on the front of monitor will blink as long as there is pressure on Pad 1 or Pad 2, respectively.
The alert will sound when pressure is released from pad. Press the “Reset” button on front of the monitor or use the Caregiver Key, depending on your reset setting to silence the alert.
If the Pad Lost light is on and system does not test properly, reduce distance between the monitor and the pad. Retest.
WHEELCHAIR/CHAIR PAD PLACEMENT
Center pad on the chair seat under buttocks.
C o
r d L
e s s
B ed
Pa
d
C
o rd L
ess
B ed P
a d
CordLess® Floor Mats
TEST THE SYSTEM
Press the “Reset” button on the front of the monitor or use the Caregiver Key,
depending on your reset setting to silence the alert. IMPORTANT: There must be a 15 second period with no pressure on the
NOTE:
If the “Pad Lost” light is on and the system does not test properly, reduce the distance
FLOOR MAT PLACEMENT
plugged into the TL-2100G fall monitor. To reestablish wireless operation, unplug the corded device and test the Cordless device(s) as described above.
Floor Mat
S a f e ty A
u t o
- R e
s e t
T M
P a
d a n d M o n i t o r
A c ti v
e w h e n b l i n k i ng
L o w Bat te r y Pa
d Lo s t
S af
e t y A ut o
- R
e s e t
T M
P ad a nd M o n i t o r
A c t i v e w hen b l i n k in
g
L o w Bat t e r y
P ad L o s t
1
2
2012-13
TL-2100G
Fall Monitor
Installation and Use Instructions
PATENT ED TE CHNOLO GY
SM ART CAREG IVER CORPORAT ION
No Cords Between Monitor and
Sensor Pads
Works with two sensor pads
simultaneously
PATENTED TEC HNOLO GY
with included Caregiver Key
TM
IMPORTANT INFOR MATION:
Smart CordLess® products utilize wireless technology which is subjec t to physical and environmental considerations. These products must be tested by the end user before each use in t he setting in which they are to be used. Please be aware that the transmitter will not be 10 0% accurate if it is out of range at any time. The transmi tter is battery operated and the life o f the battery will vary based on usage. Wireless systems
and monitors are intended as an addition to good caregiving practices and are not
supervision of all residents by caregiver(s). We recommend that all personnel receive periodic training in the operation of these systems and t hat the systems are tested before each use.
Reset
TL-2100G Rev.2
TL-2100G to fully reset.
TL-2100G and corded sensor pads/floor mats
Loading...