Smarfid Security Equipment SSHR35 User Manual

Design & Technologies
125KHz Slender Series Reader
Support reader to read either EM or HID cards.
Support on-site Reader Configuration Card to change certain parameters.
Tamper protection
Easily see under dark environment. Couldbeuseasadoorlocation
Friendly Installation
“Touch” number pad does not carry any moving parts, which implies more durable.
All weather proof design with IP65 certificate.
Economical mullion mounts type.
Design with customer logo is possible.
Number pad use “touching sensor”, the latest technology and individual number backlit when touch.
Universal back plate allows thereaderbeinstalledon different size of gang box.
Non-drop bottom screw made servicing handier.
Reverse power protection.
Stainless steel Security screw is an option
All inputs are 12Vdc protected.
All input and output signals are protected against static charges.
FCC Caution.
§ 15.19 Labelling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
§ 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
§ 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
Model Number: X1X2N1N2N3–N4X
3
RF Technologies Reader Appearance and Function
N13 = Normal Reader N25 = Normal Reader
X1X2HR = 125KHz
N32 = Read UID / Card Number
N48 = Pigtail X3N = No Number pad; K = Number pad
Model
Functions
Configurable Functions
Standard Reader Keypad Reader
Re-configure Window Reader Output Format Wiegand Plus Width Keypad Output Buzzer Control LED/Back lit Control
CSN/UID 32bits, 34bits, 56bits (backward/forward), file content reading for programmed ID
5 seconds (Default) or Half an hour after Power up
Different choices to fit with different Controller’s requirements
N/A Definable
Reader & Controller control (Default) or Controller control only
Define different LED color response base on Green LED
Technical Specifications
Typical Read range Reader Standard Output Standard Keypad output Wiring Distance Wiring Distance
N/A Wiegand with 4 bits burst
>5 cm (Base on different technology)
Wiegand (RS232 & RS485 optional)
150m (22 AWG with shielded cable)
125KHz
Operating Specification::
Operating Voltage Operating Current Operating Temperature
Exterior dimension 150*53*25 mm
10 - 15VDC
150mA (max)
-30-70
Case material Standard Color Operating Humidity Weight
PC+ABS
Black
10% - 90%
180g