SMARDY YR100-A Instruction Manual

smardy - pure water
Reverse osmosis system YR100-A 75 GPD
Instruction manual [EN]
Please read this manual carefully before operating the device and subsequently keep the
Note: we reserve the right to make technological and functional changes or surface
modifications to improve the functions and performances of our products.
-Cover sheet-
Summary
General Page 1 Contents Page 2 Scope of supply Page 2 Device identification Page 2 Safety instructions Page 3 Product launch Page 4 Product specifications Page 5 Filter description Page 5 Installation Page 6 Instruction manual Page 7 - 9 Care and maintenance Page 10 - 11 Error messages and repair Page 12 Maintenance table Page 13 Warranty conditions Page 14 Replacement filters Page 16
Scope of supply
Box
Main device (1 piece) Water connection box (1 set) Power cable (220-240V 10A)
Accessories box
Water tank (1 piece) Tank cap (1 piece)
Accessories bag
Instruction manual
Device identification
Symbol
Significance
YR100-A
Model number in accordance with type label.
The device meets all the legal requirements of the European standards.
The device is suitable for the contact with foodstuffs.
Labelled product must not be disposed of with household waste.
-2-
Safety instructions
Do not make any modifications to the installation and do not disassemble the device. Improper disassembly or modification can lead to malfunctions or leakages. Do not leave any items on top of the device– risk of overheating! Do not put any heavy items on top of the device, this can damage inner components and lead to malfunctions. Do not let the device come into contact with corroding items, this could affect the housing and toxic or dangerous substances could penetrate.
Water pressure
Water source: Drinking water Pressure: < 3 bar Do not expose the device to high water pressure, this could damage the water supply lines. A recommended water inlet pressure ranges between 0,5 and 3,5 bar.
Power supply
The power cable and the power plug are only suitable for this product, tested and approved.
ATTENTION- Use the provided power supply cable and do not operate the device with other commercial connection cables. Do not connect or unplug the power plug with wet hands!
Troubleshooting for errors
Remove the power and water supply immediately , when the product is defective or presents a malfuntion. In such cases, please contact our support team at info@smardy.de
Scope of application and temperature range
4°C - 38 ° C in a dry and clean area. Please protect the device against dirt, dust, external moisture and against heat. In addition, avoid direct sunlight – the water filter may not be installed in the vicinity of direct sunlight. The feed water should not exceed a temperature of 38 °C, this could damage the reverse osmosis membrane and lead to malfunction. Do not put the device into operation in an ambient temperature below 5 °C and ensure that the water in the device can not freeze, to prevent broken supply lines and water loss. Do not use the device outdoors to prevent a premature aging of the water pipes and possible malfunction. Do not leave the device near fire sources. Excessive temperatures can deform the housing and lead to malfunction and leakage of the device.
Transport of the water filtration system
Make sure to drain the water in the water tank before you tilt your device up to 45 degrees.
Maintenance
Do not open the device yourself to repair it. Unauthorized opening of the system invalidates the warranty.
Accessories and filters
Only use original accessories which are tested and approved by us.
Set up and install out of the reach of children
Please ensure that children do not use or operate the device unsupervised.
-3-
Product launch
Product description
The smardy pure water system is a combination of reverse osmosis and hydrogen enriching water system. It offers water in four temperature ranges to choose from: normal filtered drinking water, boiled water, hot water and warm water in order to meet the all the needs and requirements of the family. For this purpose, normal tap water will be filled into the provided tank and will be purified from harmful substances like nitrate, lime, medication, viruses, bacteria, heavy metals, microplastic, pesticides, chlorine, etc. via the membrane, sediment and activated carbon filters.
-4-
Product specifications
Permissible humidity:
<85%
Permissible humidity:
4 - 38° C
max. water equivalent
inlet
< 1000 PPM
Only use tap water
Rated output:
2150W
Rated output:
2100W
Nominal voltage:
220 - 240V / 50Hz
Max. 285 liter per day
Nominal pressure:
0 Bar
Nominal pressure:
3 bar
Output:
0,26 L / Min
Dimensions (L*W*H in
mm)
380*244*390
Filter description
Description
Function
Filter change
Filter 1 - prefilter 5micron PP filter + Activated carbon filter
Eliminates sediments, rust, asbestos, sand, sludge, humic substances and other large residues.
6 - 12
Months
Filter 2 ­Activated carbon filter + 1micron PP filter
Consisting of a high-quality activated carbon block filter + 1micron PP filter. Safely retains chlorine, chemicals and other harmful organic compounds and protects the RO membrane.
6 - 12
Months
Reverse osmosis filter
- RO Membrane ­0,0001 micron filter system
Removes impurities larger than 0,0001 μm, like e.g heavy metals, uranium, hormones, harmful chemicals, bacteria, viruses, pesticides,
medication, as well as organic and inorganic compounds.
12 - 24
Months
Note: Membrane and filter change intervals depend on the quality of the incoming water, pressure and temperature and can therefore vary.
-5-
Installation
Method 1: off-grid installation – no structural changes required.
Attention:
1. Do not remove both caps/ plugs on the back side of the device, if the device was not installed as per m per installation type method 2. And thus prevent the water from leaking.
2. Do not remove the water tank when the device produces water (indicator on the control panel). This way you prevent malfunction and damage to the water filters.
3. Empty the wastewater regularly and do not refill water into the inserted tank from above.
Method 2: grid-connected installation – possible structural changes required.
Attention:
1. For the grid-connected installation of the water filters, please contact our support team to
obtain more detailed information about the assembly and special features. We will be pleased to advise you with all the questions relating to the device.
-6-
Instruction manual
1. Description of the control panel Note: The control panel is a fully functional touch display, which indicates the actual use of the device.
Symbol
Display
Explanation of the functions
Display
digit OUT
Digital TDS-water measuring device(TDS = total dissolved solids = total quantity of dissolved solids). Measures and indicates the content of organic and inorganic substances of the filtered water.
Display
digit
IN
Digital TDS-water measuring device (TDS = total dissolved solids = total quantity of dissolved solids). Measures and indicates the content of organic and inorganic substances of the unfiltered water.
Symbol
lights up
The symbol lights up if there is not enough tap water available in the water tank, or when the TDS-value of the unfiltered water is too high. (reference this, also see the note on page 8)
Filter change
Lights up
The symbols flash by expiry of the filter life and inform you of replacing the filters accordingly. Please only use compatible replacement filters.
Symbol
lights up
Child safety activated, to prevent improper use and injuries from burns.
Symbol
lights up
Standard function of the device – by pressing the water key, filtered drinking water flows from the outlet.
Symbol
lights up
Select hot water by touching the MODE key.
Symbol
lights up
Select warm water e.g for tea by touching the MODE key.
Symbol
lights up
Select warm water e.g for baby food by touching the MODE key.
MODE
key
Use this key to select the various water temperatures.
Blue
Permanent
light
Press this key to fill with the selected water. With a blue permanent light there is still sufficient filtered water available in the tank.
Blue light
flashes
There is no longer sufficient water available in the system. Please wait 3 minutes and subsequently press the key once again to fill up with filtered water.
-7-
2. Important note for the initial commissioning: Before you ingest the water, it is necessary to flush out the new filters and the internal tank. Therefore let at least 3 full watertanks flow through the device.
3. How do you get filtered water?
Place an empty glass under the outlet. Note: For this purpose use the provided holder for support and to protect the table from splashing water.
Press the "MODE" key to select filtered water in the desired temperature.
Press the water key to start with the water outlet (blue light lights up).
Press the water key once again to stop the water outlet (blue light goes out).
-8-
Information for general usage:
1. Auto-stop function: The unit is equipped with an automatic stop function. This interrupts
the waterflow with normal filtered water and warm water after 0,5 liters and with hot water after 60 seconds.
2. Child safety lock:
The device is equipped with a child safety lock. This function is activated by default, as soon as the
device is connected to the power supply. With the activated child safety lock, normal filtered water will flow out of the device upon request.
You can still select hot water tea/coffee water or warm water
by pressing the MODE key. However, if within 10 seconds no request of the selected water occurs,
the function will automatically return to the normal water mode .
To deactivate the child safety lock, press and hold the water key for 5 seconds.
To reactivate the child safety lock, press and hold the water key once again for 5 seconds.
3. Emptying of the internal water tank
In order to be able to transport or repair the device,
it is necessary to empty the internal tank.
To do this, press and hold the MODE key and the
water outlet key simultaneously for 3 seconds.
As soon as the total water (approx. 1 liter) has flown
out of the device, please press the water outlet key
once. The internal tank is now empty and the device
can be transported/repaired.
4. Flashing icon
When the symbol lights up, there is not sufficient tap water in the external tank of the device or the TDS-
value of the unfiltered water in the external tank exceeds the limit value. Therefore empty the external
tank periodically and refill with fresh tap water.
When the blue symbol flashes, there is not sufficient water in the internal tank. No more water flows
out.
-9-
Care and maintenance
1. Filter change
The device informs and reminds you independently of necessary filter changes via this indicator on the display. The symbols flash when the service life of the filters has been reached and inform you of changing the filters accordingly.
2. Procedure – work steps
Our device is equipped with so-called QuickChange filters. Please only use compatible replacement filters. You can obtain these quickly and reliably in our online shop. (s. page 15)
3. Reset filter indicator - Reset
After the filter change it is necessary to reset the filter indicator with the aid of the reset buttons (see picture). Press and hold button for 5 seconds, to reset filter 1 and 2, press and hold button for 5 seconds, to reset filter 3.
-10-
4. Descaling of the external water tank
Depending on the degree of water hardness in your regio, over time there will be calcifications in the bottom and on the inner walls of the external water tank. The harder the water, the faster the formation of calcifications. It is important to descale the external water tank of the smardy - pure water reverse osmosis system at least every 3 months but not more often than six times a year.
Descaling process
1. Remove the water tank from the device.
2. In a measuring cup mix 50 grams of smardy special decalcifier with 1 liter warm water (approx. 50 degrees). Stir the liquid, until the powder is completely dissolved.
3. Fill the water container with the descaling mixture up to the mark MAX.
4. Leave the mixture in the tank for approx. 1 hour.
5. Empty the water tank and rinse out several times with clear water.
6. Reinsert the cleaned water tank into the device.
Note: You can also use other suitable descaling agents, in doing so, please follow the manufacturer’s instructions.
smardy special decalcifier is available via the following link:
https://www.amazon.co.uk/dp/B06ZZQWM37
5. Disinfection of the device
We recommend to disinfect the smardy - pure water reverse osmosis system regularly , at the latest every 6-12 months (when changing the filters). For this purpose you obtain a specially designed disinfection set in our accessories shop.
For further detailed instructions, please refer to the application instructions included in the disinfection set.
This set is available via the following link:
https://www.amazon.co.uk/dp/B06Y653P7R
-11-
Error messages and repairs
ATTENTION! If a malfunction occurs during the operation of your device:
Water escapes from the tubes or other components Some elements do not function correctly Device components conduct electricity You detect other anomalies or errors on the device
and/ or an error code appears on the display, please switch off the device, remove the power plug and contact our customer service at info@smardy.de
Error code
on the
display
Malfunction
Action
without
No normal tempered water is being
dispensed
Check whether the power plug is loose or not plugged in. There is not sufficient water in the tap water tank, the symbol flashes.
without
Low water pressure or no
water supply
Check the inlet water pressure There is not sufficient water in the tap water tank
without
Button/ display does not function
The device is damaged or defect.
Check whether the power plug is loose or not plugged in. Contact our customer service
E1
Water pump defective
Contact our customer service
E2
Water level defective
Contact our customer service
E3
Temperature sensor defective
Contact our customer service
E4
Outlet valve defective
Contact our customer service
E5
Valve cleaning defective
Contact our customer service
E6
Outlet pump defective
Contact our customer service
E8
Reset button defective
Contact our customer service
For all other defects or malfunctions of the device, please unplug the power plug immediately and inform our customer service.
When you do not use the device for a long period of time, also disconnect the device from the water supply or unplug the power cable.
In the event of damage to the device/or is components please contact our customer service department or a specialist. We shall not be liable for possible damages caused by improper handling.
Return shipment
If the problem cannot be solved by our customer service department, please return the device to us. Do not return it freight forward but as a franked package. Also avoid external damages and contamination of the device.
If possible, return the device to us in its original packaging with all accessories and all packaging components. If you no longer have the original packaging, please ensure an appropriate packaging to avoid damage during transport.
-12-
Maintenance table
Brought into operation for the first time on: Month_______ Year_______
FILTER:
1
FILTER
2
FILTER
3
Composite Micro Filter Replaced on:
Composite Activated Carbon Replaced on:
RO Membrane Replaced on:
-13-
Warranty conditions
JustMore GmbH & Co. KG gives a 24 month guarantee from the date of purchase on all material and processing errors of the device (except for all filters, membranes and storage tanks). The original purchase receipt serves as the warranty certificate. During this period, we will repair the product by installing new components free of charge.
In the event that problems occur during or after the expiry of the guarantee period, please contact our customer service department at info@smardy.de.
This warranty applies only to the original purchaser. It only covers material and processing errors which occur by proper use. The warranty does not apply to damages caused by transport, improper handling, negligence, as well as interventions and changes undertaken by unauthorized agencies.
JustMore GmbH & Co. KG is not liable for consequential damages that arise from the use of the device.
© All rights reserved JustMore GmbH & Co. KG – Robert-Bosch-Straße 6 B –
86830 Schwabmünchen - Germany
- Technical changes reserved–
-14-
Notes
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
..........................................................................................................................................
-15-
Replacement filters
6 - 12 Months* 6 - 12 Months* 12 - 24 Months*
*recommended change interval
-Back cover-
https://www.amazon.co.uk/dp/B01N40W222
https://www.amazon.co.uk/dp/B01MYMR309
https://www.amazon.co.uk/dp/B01N750UKF
Loading...