SW-700 – Ethernet Switch
SW-700 MODULE
Part Number
SW-700 - Ethernet Switch
Smar SW-700 module is a Fast Ethernet Switch that provides LAN networks with 10 Base-T/100 Base-TX high-speed auto-sensing connectivity. Five ports, where one is dedicated for the Uplink will provide access for many devices and will help to eliminate traffic congestions that cannott be well treated by Network Hubs.
The SW-700 is also a great choice when connecting different speed networks as Ethernet and Fast Ethernet and will also optimize finding the right path for same type of Ethernet. LED indicators for link/activity, speed, full/half duplex and collision for each individual port and one for module power.
It can be powered by the Rack or by an external 24Vdc. Power supply redundancy circuit will automatically switch from the user preferred supply to the other one in case of failure.
Industrial design, no internal fans and low EMC makes it a great option for automation and process control applications.
Operation
The SW-700 has a frame buffer composed of 1M bits of built-in memory. The address look-up table for MAC addresses learning/searching consists of 1K direct-mapping trie s.
The SW-700 uses Nway auto-negotiation to complete the UTP port connections of physical links which conform to IEEE 802.3u specifications. IEEE 802.3x full duplex flow control is supported. When operating in half duplex mode, a proprietary back-pressure algorithm is implemented to
prevent traditional hub devices from partitioning due to excessive collisions.
SW-700 Auto-sensing Ethernet Switch
1.1
SW-700 - Instruction Operation Manual
The SW-700 supports non-blocking wire speed forwarding rates and special designs to resolve head-of-line blocking problems and channel-capture problems. A broadcast storm filtering function is also provided for abnormal broadcast traffic issues.
Auto-polarity is implemented to correct the detected reverse polarity of RXIP/RXIN signal pairs. The SW-700 implem ents power saving mode on per port basis. A port automatically enters power saving mode 10 seconds after the cable is disconnected from it.
Address Search, Learning and Aging:
The SW-700 contains a full 1K of look-up table entries and uses a direct-mapping scheme to achieve address search and learning.
By extracting the least 10 bits of a destination MAC address to index the 1K-entry look-up table, the SW-700 can decide where the packet goes. If the searching result indexes to an empty entry, the packet is broadcast to all other ports. On the other hand, the SW-700 extracts the least 10 bits of a source MAC address to index the 1K-entry look-up table. If the result indexes to an empty entry, it records the source MAC address and related switching information. If the result leads to an occupied entry with different switching information, it updates the entry with the new information. This is referred to as 'learning'. The look-up engine will update time stamp information of an entry whenever the corresponding source MAC address appears. If the time information is not updated for a period of time, the entry will be removed, referred to as the aging process. The maximum aging time for the SW-700 is approximately 300 seconds, and the minimum aging time is approximately 200 seconds.
Installation
The SW-700 may be installed in a rack, powered by the rack bus or alone with a 24 Vdc external power supply, using the DF9 rack to mount it on the DIN rail. For both cases, when the module is powered, the green LED for power indication will light.
Installation of the module into the DF9 individual support
SW-700 module can also be installed into the DF9 individual support using 24 Vdc external power supply. DF9 can be observed in the picture below:
1.2
Individual Support– DF9
SW-700 Module
Installation of the Module into the Rack R700-4
The SW-700 module can be installed in the rack, powered by the bus rack. The Rack R700-4 is ready for mounting in DIN rail. The steps for the module installation are showed below:
Rack - R700-4
Attach the top of the module (with a 45o inclination) to the module support located on the upper part of the rack.
Mounting detail.
Push the module fixing it to the module connector.
Next, fix the module to the rack using a screwdriver, and fasten the fixation screw at the bottom of the module.
1.3
SW-700 - Instruction Operation Manual
Redundant Power Supply Operation
The SW-700 may be powered externally or through the IMB. So, it supports power supply redundancy. The user must set jumpers in order to configure the main power.
Find the jumper at the bottom of the module box. With the aid of a plier set the position of the jumpers according to the operation mode.
Main power supply
through an external
power supply and IMB
redundancy.
Procedure:
Jumper must be placed
between 1 and 2
Main power supply
through an IMB and
external power supply
redundancy.
Jumper must be put
between 2 and 3
Procedure:
Jumper detail
1.4
4 Ports (Regular Ports)
RJ-45
to a hub or switch)
Internal (rack)
5 Vdc
Current Consumption
500 mA maximum
Voltage Range
10 - 35Vdc
Current Consumption
115 mA @24 Vdc maximum
Power Consumption
2.8 W maximum
System: Power LED Uplink: Collision/Speed/Active
Each port automatically enters on power saving mode 10 seconds after cable disconnect.
Technical Specifications
SW-700 Module
PORTS
1 Port (Uplink Port - no cross cable to connect
INTERNAL POWER
EXTERNAL POWER
COMPATIBILITY
Fully compliant with IEEE 802.3 and 802.3u
Connector Type: RJ45 Ethernet 10Base-T and High Speed Ethernet 100Base-TX
INDICATION LEDS
Individual Ports: Collision/Speed/Active
POWER SAVING
RJ-45
NETWORK
REDUNDANCY
Between Internal IMB Vcc and the External Power Supply
TEMPERATURE
Operation 0ºC to 60ºC
DIMENSIONS AND WEIGHT
Dimensions 39.9x137.0x141.5 mm (1.57x5.39x5.57 in) Weight 0.290 kg
1.5
SW-700 - Instruction Operation Manual
1.6
Appendix A
Proposal Nº:
Company:
_____________________________________________________________________________________________________
COMMERCIAL CONTACT
Full Name:
____________________________________________________________________________________________________
E-mail:
_______________________________________________________________________________________________________
TECHNICAL CONTACT
Full Name: ________________________________________________________________________________________________
E-mail:
PROCESS DATA
Process Type (Ex. boiler control): __________________________________________________________________________
USER INFORMATION
SRF – SERVICE REQUEST FORM
SW-700 – Ethernet Switch
COMPANY INFORMATION
Unit: Invoice:
Phone: _________ _________________________ _________ _________________________ Fax: _______________________
Phone: _________ _________________________ _________ _________________________ Extension: ____________________
________________________________________________________________________________________________________
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
EQUIPMENT DATA
Model: Serial Number:
Operation Time: ____________________________________________________________________________________________ Failure Date: __________________________________________________________________________________________________
______________________________________________________________________________________________________
________________________________________________________________________________________________
FAILURE DESCRIPTON
______________________________________________________________________________________________________________ ______________________________________________________________________________________________________________ ______________________________________________________________________________________________________________ ______________________________________________________________________________________________________________
(Please, describe the failure. Can the error be reproduced? Is it repetitive?)
OBSERVATIONS
______________________________________________________________________________________________________________ ______________________________________________________________________________________________________________ ______________________________________________________________________________________________________________ ______________________________________________________________________________________________________________
Company: _____________________________________________________________________________________________________ Contact: _______________________________________________________________________________________________________ Section: _______________________________________________________________________________________________________ Title: ________________________________________________ Signature:_______________________________________________ Phone: _________ _________________________ _________ _________________________ Extension: ___________________ E-mail: ________________________________________________________________________ Date: ______/ ______/ _________
For warranty or non-warranty repair, please contact your representative. Further information about address and contacts can be found on www.smar.com/contactus.asp
A.1
SW-700 - Instruction Operation Manual
A.2
Loading...