SMAC LAC-25 Technical Reference Manual

Page 1
SMAC
LAC-25
TECHNICAL REFERENCE MANUAL
Revision 3.4, February 1998
SMAC CORP.
5807 Van Allen Way
Carlsbad, CA 92008
Page 2
5807 VAN ALLEN WAY
CARLSBAD, CA 92008
PHONE: 1-760-929-7575 / FAX: 1-760-929-7588
FOR TECHNICAL ASSISTANCE CALL: 1-760-929-7575
© COPYRIGHT A UTOMATION MODULES , INC. 1993 - 1998
Page 3
SMAC LAC-25 Technical Reference Manual
Table of Contents
1. INTRODUCTION ............................................................................................................................7
1.1 SPECIFICATIONS .............................................................................................................................7
1.2 DIGITAL I/O INTERFACE....................................................................................................................8
1.2.1 Dedicated Digital Inputs .......................................................................................................8
1.2.2 General Purpose Inputs.........................................................................................................8
1.2.3 General Purpose Outputs......................................................................................................9
1.2.4 Digital I/O "States"................................................................................................................9
1.2.5 I/O Technical Specifications..............................................................................................10
1.3 ENCODER INTERFACE....................................................................................................................11
1.4 OUTPUT DRIVER INTERFACE ...........................................................................................................11
1.5 ANALOG TO DIGITAL CONVERSION (A/D) INTERFACE............................................................................11
1.6 SERIAL INTERFACE ........................................................................................................................11
2. MACRO INTERRUPT SYSTEM ....................................................................................................13
2.1 THE INTERRUPT VECTOR TABLE......................................................................................................13
2.2 ENABLING AND DISABLING INTERRUPTS .............................................................................................13
2.3 INTERRUPT SOURCES....................................................................................................................14
2.4 INTERRUPT PRIORITY ....................................................................................................................14
2.5 INTERRUPT COMPLETION................................................................................................................15
2.6 INTERRUPT LATENCY.....................................................................................................................15
3. ENTERING COMMANDS..............................................................................................................17
3.1 DOWNLOADING COMMANDS ............................................................................................................18
4. INTRODUCTION TO COMMANDS................................................................................................19
4.1 PARAMETER COMMANDS................................................................................................................19
4.2 REPORTING COMMANDS.................................................................................................................30
4.3 MOTION COMMANDS .....................................................................................................................37
4.4 REGISTER COMMANDS...................................................................................................................44
4.4.1 Internal Variables................................................................................................................44
4.5 SEQUENCE COMMANDS .................................................................................................................52
4.6 LEARNED POSITION STORAGE (LPS) COMMANDS ..............................................................................57
4.7 MACRO COMMANDS ......................................................................................................................58
4.8 INPUT / OUTPUT (I/O) COMMANDS ..................................................................................................62
4.9 FUTURE EXPANSION INTERFACE ......................................................................................................64
4.10 SERIAL COMMUNICATIONS AND MISCELLANEOUS COMMANDS .............................................................65
5. APPENDIX A, LAC-25 ERROR CODE DEFINITIONS ...................................................................72
6. APPENDIX B, SUMMARY OF LAC-25 COMMANDS.....................................................................74
7. APPENDIX C, LAC-25 CONNECTOR PIN DEFINITIONS..............................................................75
8. INDEX .........................................................................................................................................76
5
Page 4
SMAC LAC-25 Technical Reference Manual
1. Introduction
The LAC-25 is a two axis stand-alone integrated controller / driver, with input / output (I/O) capabilities, designed primarily for the control of DC brush type motors or actuators with itÕs integrated driver, or other types or motors by interfacing the onboard analog output capabilities with external drivers.
The LAC-25 implements a mnemonic type command instruction set via a standard RS-232 serial communications interface. These commands can be executed directly or used to create command macros which are stored in the onboard nonvolatile RAM (NVRAM).
The LAC-25 can interface to the real world via the onboard motor drivers, 2 channels of quadrature type encoder interface, 4 channels of optoisolated digital input and 4 channels of optoisolated digital output, with additional optoisolated inputs serving for limit, home and fault functions, 5 channels of 10-bit analog to digital (A/D) conversion (2 of which are reserved for monitoring amplifier output current), and an RS-232 serial communications link. A proprietary RS­422 interface is provided for future I/O expansion modules.
1.1 Specifications
Description Stand-Alone 2 Axis Servo Motor Controller / Driver Operating Modes Position, Velocity, Torque and Electronic Gearing Filter Algorithm PID Max. Filter Update Rate 100 µS Per Enabled Axis Trajectory Generator Trapezoidal, Electronic Gearing Servo Position Feedback Incremental Encoder with Index Output (Standard) PWM Motor Drive, 3 Amps Cont. and 6 Amps Peak at 50 VDC
Max. PWM Frequency Approximately 19.531 KHz Encoder And Index Input Single-ended or Differential Encoder Supply Voltage 5 VDC Encoder Input Voltage 5.5 VDC Max., -0.1 VDC Min. Encoder Count Rate 2 Million Quadrature Counts per Second Position Range 32 Bits Velocity Range 31 Bits Acceleration Range 31 Bits General Purpose Digital
I/O Dedicated Digital Inputs Limit+, Limit-, Home and Fault for each axis Analog Inputs 5 Channels With 10-Bit Resolution, 3 are user accessible
Analog Outputs 2 Channels With 12-Bit Resolution, ±10VDC.
Communication Interface RS-232 Serial Interface, Adjustable Baud Rate, 8 Bits, 1 Stop Bit,
Supply Voltage +18 To +50 VDC Motor Voltage +12 To +48 VDC Dimensions Approximately 7.6Ó Long by 3.3Ó Wide by 1.1Ó Thick Weight Approximately 1 Lb.
4 Optoisolated Inputs, 4 Optoisolated Outputs
No Parity, XON/XOFF Handshake
Table 1. Specifications.
7
Page 5
SMAC LAC-25 Technical Reference Manual
1.2 Digital I/O Interface
The LAC-25 includes 4 channels of general purpose digital input and 4 channels of general purpose digital output. Additionally, there are four channels of dedicated digital input for each of the two axis'. All of these I/O are protected through the use of optoisolators.
1.2.1 Dedicated Digital Inputs
Figure 1 illustrates one of the LAC-25Õs dedicated digital inputs. These inputs are Limit+, Limit-, Home and Fault for both axis of the LAC-25. The power to activate these inputs is provided by the LAC-25 so it is only necessary to complete the circuit to activate the input.
The Limit inputs are intended for signaling the LAC-25 that an axis has reached itÕs end of travel. When such an event occurs, the LAC-25 can ignore the event or stop the servo in some controlled fashion. The Home input is for detecting some sort of "home position" sensor. This c an be used with the encoder index input to implement a very accurate homing method. A typical use for the Fault input is for an external device to signal a fault condition such as over-temperature.
Note: The external Fault input is tied to the internal over-temperature signal from the onboard
drivers. When a fault condition occurs, that is either the internal over-temperature signal or external Fault signal go active, the 16-bit internal variable FCNT (see Internal Variables) begins to increment at 1 rate of once per millisecond. If the fault condition clears then the FCNT variable is also cleared. If the fault condition remains present long enough for the FCNT variable to count up to the value assigned to the FCMP variable, then the over Fault bit in the status word will be set and the servo will be disabled (assuming the Fault interrupt has not been enabled). The default value for FCMP is 10000 which will give a 10 second delay before causing the Fault bit to be set.
1.2.2 General Purpose Inputs
Figure 2 illustrates one of the LAC-25Õs general purpose inputs. These inputs are galvanically isolated from the LAC-25. Current of the proper polarity must be supplied to the circuit to activate the input.
Figure 1. LAC-25 Dedicated Input.
8
Page 6
SMAC LAC-25 Technical Reference Manual
Figure 2. LAC-25 General Purpose Inputs
1.2.3 General Purpose Outputs
Figure 3 illustrates one of the LAC-25Õs general purpose outputs. These outputs are galvanically isolated from the LAC-25. When an output is activated, positive current will flow from the collector of the optocoupler transistor (the output pin) to itÕs emitter (the output return pin),
Figure 3. LAC-25 General Purpose Output
1.2.4 Digital I/O "States"
There are several commands that deal with controlling the digital I/O. All of these commands operate based on the following philosophy: With regard to an input, "active" means there is sufficient current flowing through that input and "inactive" means there is lack of sufficient current through that input. With regard to outputs, "active" means the ability for an output to pass current and "inactive" means the inability for an output to pass current.
The Channel High (CH) and Channel Low (CL) commands provide the user with the ability to determine whether a channel is active in the "on" state (CH) or active in the "off" state (CL). This is analogous to a switch and to whether it is normally open or normally closed. The Channel On (CN) and Channel Off (CF) commands do exactly as they imply in that they will turn a given output either on or off, which will make that output either active or inactive depending on the CH and CL commands as stated previously.
The (CH) command causes the following interpretation of the inputs and outputs:
An "activated" output is considered to be ON (e.g., Channel On ÒCNÓ command).
An "inactivated" output is considered to be OFF (e.g., Channel Off ÒCFÓ command).
An "activated" input is considered to be ON (e.g., Do If On ÒDNÓ command).
An "inactivated" input is considered to be OFF (e.g., Do If Off ÒDFÓ command).
The (CL) command causes the following interpretation of the inputs and outputs:
9
Page 7
SMAC LAC-25 Technical Reference Manual
An "activated" output is considered to be OFF (e.g., Channel Off ÒCFÓ command).
An "inactivated" output is considered to be ON (e.g., Channel On ÒCNÓ command).
An "activated" input is considered to be OFF (e.g., Do If Off ÒDFÓ command).
An "inactivated" input is considered to be ON (e.g., Do If On ÒDNÓ command).
Input Current ÒCHÓ ÒCLÓ Output Current ÒCHÓ ÒCLÓ
Flowing On Off Flowing CN CF
No Flow Off On No Flow CF CN
Table 2. I/O States.
Another feature of the digital input system is the ability for software input debouncing. All of the general purpose digital inputs are automatically sampled once every millisecond. Depending on the debounce delay set by the Input Debounce (ID) command, a given input must remain in the same state during one or more samplings before it is considered valid. If an input were to be found in a changed state during a sampling, the input would become invalid and the debounce delay would be restarted. If no or "0" debounce delay is used, then no input debouncing is performed. For example: if a "ID5" command has been issued, then a given input must remain in the same state for 5 samplings or for 5 milliseconds.
1.2.5 I/O Technical Specifications
1.2.5.1 General Purpose I/O Nominal Specifications.
Unit Specification
5 V Minimum voltage to activate input.
0.83 mA Input current at minimum activation voltage. 24 V Maximum input voltage.
4.87 mA Input current at maximum voltage.
1.1 V Maximum voltage to deactivate input. 6 V Absolute maximum reverse input voltage.
40 V Maximum voltage output can sustain.
100 mA Maximum current output can sustain.
Table 3: General Purpose I/O Specifications
1.2.5.2 Dedicated I/O Nominal Specifications.
Unit Specification
10 Maximum external circuit resistance to activate
input.
1K Minimum external circuit resistance to deactivate
input.
Table 4: Dedicated I/O Specifications
10
Page 8
SMAC LAC-25 Technical Reference Manual
1.3 Encoder Interface
The LAC-25 has two channels of quadrature type encoder interface with optional index signal input and the ability to supply +5 VDC at a minimum of 50 mA (or greater depending on other demands put on the internal 5 VDC power supply). The phase A+ and phase B+ inputs are pulled up to +5 VDC with 2.7K resistors, and the phase A- and phase B- inputs a biased at +2.5 VDC with 2.7K resistors. This arrangement which will accommodate both open collector and totem pole single-ended output encoders or differential output encoders. The phasing of the channels as well as the index signal sense can be changed via program command.
1.4 Output Driver Interface
The LAC-25 onboard output drivers are PWM switching amplifiers capable of supplying 3 Amps continuous and 6 Amps peak (for 200 mS minimum) at a switching frequency of approximately 19.531 KHz. These drivers are intended for driving DC brush type motors or actuators. Both drivers share the main power supply input and the peak voltage output to the motor will be nearly that of what is supplied.
The output drivers include an over-temperature sensor. If this sensor determines that the amplifierÕs temperature is greater than 140¡ C, the amplifier will then be disabled and the Over­Temperature bit will be set in that axis' status word.
For applications requiring capabilities above those of the onboard drivers, the ability to
interface to external drivers is provided. This consists a 12-bit D/A ±10 VDC analog output signal for
each axis. In applications where external drivers are not required, the analog outputs can be used for other purposes (e.g.,: oscilloscope monitoring of following error or output command).
1.5 Analog to Digital Conversion (A/D) Interface
The LAC-25 provides a 5 channel, 10 bit A/D conversion interface with a +10 VDC reference and analog ground. For reverse compatibility purposes the A/D interface is actually
ten channels but the user is only given access to channels 0, 1 and 2 while channels 6 and 7 are used internally for monitoring the output current of the onboard drivers. The other channels are unavailable and should be ignored.
Whenever a Tell Analog "TA" or Get Analog "GA" command is issued, the specified A/D channel is converted and the result is either reported or stored for access by the user. Also, whenever the servo loop for an axis is executed, the "current monitoring" channel for that axis is converted and the result is stored for later access.
1.6 Serial Interface
The LAC-25 communicates with a host computer or a "dumb" terminal via an RS-232 serial interface. The baud rate is user selectable from 300 to 19,200 baud with 9600 baud being the default. Characters are fixed at 8 bits in length with 1 stop bit and no parity. Software XON / XOFF handshaking is provided. Hardware handshaking is not supported at this time.
11
Page 9
SMAC LAC-25 Technical Reference Manual
2. Macro Interrupt System
The LAC-25 employs a "Macro Interrupt System" to provide additional versatility i n programming the LAC-25. This system comprises 32 interrupt sources with corresponding vectors. When an interrupt's source is enabled for operation and then becomes active, the current macro being executed is saved to a so called macro stack and execution of the macro specified by that interrupt's vector table entry begins. This happens to be similar procedure to that which the Macro Call (MC) command follows.
2.1 The Interrupt Vector Table
The Interrupt Vector Table consists of an entry for each interrupt source and each entry will correspond to that interrupt's level (level 0 = entry 0, level 1 = entry 1, etc.). A particular table entry must be loaded with the number of a valid macro to be executed should that interrupt source become active. The method for loading a vector table entry is provided by the Load Vector (LV) command. The user must first use the Accumulator Load (AL) command to set the number of the macro for a vector. The LV command is then used to transfer the low 8-bits of the accumulator to the vector table entry specified by the LV command. If an interrupt is generated and that vector table entry has not been defined (equal to 0) then the interrupt will not be executed. Note that this implies that macro "0" cannot be used as an interrupt macro. If an interrupt is generated and it's vector table entry has been defined but the macro it specifies has not, then an error will be reported.
2.2 Enabling and Disabling Interrupts
Loading a vector table entry will not enable an interrupt for operation. The Enable Vector
(EV) command must be used for this purpose. When the EV command is used, it will enable the interrupt source (specified with the command) to function. In the event that it is necessary to disable an interrupt source, there is a Disable Vector (DV) command that functions in a similar manner as the EV command.
In order to prevent multiple or continuous interrupts, as an interrupt is taken it is automatically disabled. This means that the user must re-enable that interrupt using the EV command before it will occur again.
13
Page 10
SMAC LAC-25 Technical Reference Manual
2.3 Interrupt Sources
The following table lists all the possible interrupt sources.
Interrupt Source Level / Vector Interrupt Source Level/Vector
Axis 0 Error 31 Reserved 15 Axis 1 Error 30 Reserved 14
Reserved 2 9 Reserved 13
Reserved 2 8 Reserved 12 Axis 0 Fault 27 Reserved 11 Axis 1 Fault 26 Reserved 10
Reserved 2 5 Reserved 9
Reserved 2 4 Reserved 8 Axis 0 Limit 23 Reserved 7 Axis 1 Limit 22 Reserved 6
Reserved 2 1 Reserved 5
Reserved 2 0 Reserved 4
Axis 0 IP/IR 19 Digital Input 3 3 Axis 1 IP/IR 18 Digital Input 2 2
Reserved 1 7 Digital Input 1 1
Reserved 1 6 Digital Input 0 0
Table 5. Macro Interrupt Sources.
The Axis Error interrupts indicate that the position following error for a given axis has exceeded the limit set by the Set Error (SE) command. Normally, when this limit is exceeded, the servo is disabled and the "Error" bit in that axis' status word is set. If the interrupt for this condition
is enabled, the "Error" bit will still be set but the servo will not be disabled.
The Axis Fault interrupts indicate that a fault condition (usually an over-temperature condition) has arisen. Normally, when this condition is detected, the servo is disabled and the "Fault" bit in that axis' status word is set. If the interrupt for this condition is enabled, the "Fault"
bit will still be set but the servo will not be disabled.
The Axis Limit interrupts indicate that either a Limit+ or Limit- condition for an axis has been detected. Whether or not a limit input will be recognized is determined by the Limit On (LN) and Limit Off (LF) commands. The action taken is determined by the Limit Mode (LM) command.
Digital Inputs 00 - 03 provide 4 levels of undedicated, user definable interrupts. T he interrupt for a given input will be active when that input is active.
2.4 Interrupt Priority
If more than one interrupt source becomes active at the same time, then the source with the higher level will be executed first. Level/vector 31 has the highest priority and level/vector 0 has the lowest priority.
14
Page 11
SMAC LAC-25 Technical Reference Manual
2.5 Interrupt Completion
Once an interrupt macro (or set of macros) has finished executing, a Return from Call (RC) command or an undefined macro may be used to cause a return from the interrupting macro back to the interrupted macro where command execution will continue from where it was interrupted (see MS command). In cases where it is undesirable to return to the interrupted macro, the Unpush Macro (UM) command can be used to remove the previously pushed macro from the macro stack. This command can also be used to completely reset the macro stack in order that the user program can be restarted.
2.6 Interrupt Latency
Interrupt sources are sampled before each command in a macro is executed. This means that the amount of time that an interrupt is held off before execution (also known as interrupt latency) depends on how long it takes the previous command to complete. For most commands this delay will be imperceptible.
Commands such as Wait (WA), Wait for Edge (WE), Wait for Stop (WS), Wait for Off (WF), Wait for On (WN) and Wait for Index (WI) would normally be a source of unacceptable delay in that they can quite often be indeterminate in length. This problem has been avoided by making these instructions interruptable. For example, if a WA10000 command (a 10 second delay) is currently i n progress and an interrupt comes along, the remaining delay period will be saved and then returned to after the interrupt has completed. If the interrupt were to take 3 seconds to execute, then the total wait time of the WA10000 command would be extended to 13 seconds.
The Position Mode (PM), Torque Mode (QM), Velocity Mode (VM), Wait for Position Absolute (WP) and Wait for Position Relative (WR) commands and any command that uses the serial communications link are all commands that could cause unacceptable interrupt latency. Therefore, their usage should be carefully considered where interrupts are possible.
15
Page 12
SMAC LAC-25 Technical Reference Manual
3. Entering Commands
Immediately after power-up, the LAC-25 is ready to accept commands. To verify this, you can hit the ESC key. If everything is working properly, this should cause a greater than sign (">") prompt to appear on your display. If not, you need to verify that the power and communications connections are correct and verify the compatibility of the communications protocol.
Commands are entered via a "dumb" terminal or host computer such as a PC compatible. Commands sent to the LAC-25 should consist of standard ASCII characters, and the command lines should be followed by a carriage return. Linefeeds are not necessary since they are used for formatting and therefore they are ignored. As characters are entered at the keyboard, they should be echoed on your display. If your display echoes its own transmitted characters, you will want to issue the Echo Off (EF) command; otherwise, the Echo On (EN) command (which is the default mode) should be issued. If you enter an invalid command, the LAC-25 will respond with a question mark "?" followed by a code indicating the type of error and the Status LED will begin to blink. These codes are listed in Appendix A, LAC-25 Error Code Definitions.
If you make a mistake when entering a command, you can backspace to correct the error. If you are entering commands and change your mind, hitting the ESC key will cancel the line and give a new ">" prompt.
Once a command line has been entered and has finished executing, hitting the RETURN key will cause the same command line to be re-executed. While a set of commands are executing, hitting the space bar will cause command execution to pause until the space bar is hit again. Also, if the ESC key is hit during execution or pause, command execution will be terminated, and you will receive a new ">" prompt.
Command instructions are intended for use with the following syntax:
[Axis#]Command[Argument]<CR>
or...
[Axis#]Command[Argument],[Axis#]Command[Argument],...etc.
The axis number is normally specified as being from "1" to "2" with "0" being used to refer to both axis' at the same time. Once an axis has been specified, the same one will remain in effect until another is specified. For example, if the following were entered:
1SG100,SD500,SV1000000<CR>
or...
1SG100<CR> SD500<CR> SV1000000<CR>
the SG command specifies the axis number, so the subsequent SD and SV commands are performed on the same axis. If the following command were issued:
0TP<CR>
it would have the same affect as issuing these commands:
1TP<CR> 2TP<CR>
17
Page 13
SMAC LAC-25 Technical Reference Manual
During interrupts and macro calls, the axis number is saved and then later restored. After an interrupt macro entered or a macro call is taken, it is a good idea for the user to make sure an axis number (if necessary) gets set during one of the first commands encountered.
The numerical range of an argument will vary depending on the command with which it is used. The mathematical interpretation of the argument will depend on whether the Decimal Mode (DM) or Hexadecimal Mode (HM) was the last issued (DM is the power on default). Both decimal and hexadecimal numbers less than zero should be entered with a preceding minus "-" sign. If no argument is given, then it will be assumed as "0". The exceptions to this are the Macro Define (MD), Macro Jump (MJ), Macro Call (MC),Macro Sequence (MS), Reset Macro (RM) and Tell Macro (TM), commands. It should be noted that commands can be strung together by using commas, up to a maximum line length of 127 characters.
If a command line is ended by a ";" and a comment, i.e...
>SG1000,SD5000 ; Set filter gains.<CR>
then the ";" and anything following it to the end of the line will be ignored. This feature is not particularly useful if you are entering commands manually, as comments are not retained by the LAC-25. However, if commands are downloaded to the LAC-25 from a host computer, the ability for line comments can make program documentation possible and desirable.
3.1 Downloading Commands
In many cases, it is more convenient to enter commands using a text editor on a host computer and then download that text file to the LAC-25 using a communications program such as
ProComm or the Microsoft
used, it must have the ability to provide a short delay (approx. 100 mS) after transmitting each line to give the LAC-25 time to interpret and store the commands that were just sent.
Windows Terminal program. Whatever communications software is
18
Page 14
SMAC LAC-25 Technical Reference Manual
4. Introduction to Commands
The LAC-25 command instructions are varied and consist of several categories of purpose. The command descriptions will be detailed by these categories.
4.1 Parameter Commands
The parameter setting commands are considered to be those for setting the operating conditions of the servo system (i.e. PID filter gains, velocity, acceleration and etc.).
Command: aDBn -- Dead-Band --
Argument: 0 <= n <= 16383 Default: 0
This command sets the position following error dead-band for servo axis 'a'. The purpose for the DB command is to allow an acceptable static position error for which there will be no restoring force. This has the affect of reducing or eliminating "hunting" which is the continuous movement at or about a position in trying to seek that position. This is useful for applications that cannot tolerate this condition. Please note that the DB command is only in effect when the servo is not in motion (or when the Trajectory Complete bit is set in the servo status word).
Related Commands: TF
Command: aFAn -- Feed-forward, Acceleration --
Argument: 0 <= n <= 32767 Default: 0
This command allows for the adjustment of the PID digital filter acceleration feed-forward term for servo axis 'a'.
During the course of a Position Mode (PM) or Velocity Mode (VM) move, at any point during acceleration or deceleration (with a consistent load), the ideal required value of the servo output is fairly consistent and somewhat predictable.
During acceleration or deceleration:
OUTPUT = (VELOCITY * FV_CONSTANT) + (ACCELERATION * FA_CONSTANT)
During constant velocity:
OUTPUT = (VELOCITY * FV_CONSTANT)
If this value can be dynamically predicted and summed with the output of the PID digital filter, i n effect, it reduces the burden of the PID filter to make lead/lag corrections based of the following error, thereby enhancing performance.
Related Commands: FV, OM, OO
19
Page 15
SMAC LAC-25 Technical Reference Manual
Command: FF -- Fail Input Off --
Default: Off
This command has no effect but is retained for backward compatibility purposes.
Command: FN -- Fail Input On --
Default: Off
This command has no effect but is retained for backward compatibility purposes.
Command: aFRn -- Set Derivative Sampling Period --
Argument: 0 <= n <= 127 Default: 0
This command allows for the adjustment of the derivative sampling interval for servo axis 'a'. The period of this interval can be calculated by the following:
T = (n+1) * S * 0.000100
where "T" is the period in seconds, "n" is the FR command argument and "S" is the sample period count specified by the Servo Speed (SS) command. For example, if the value previously set by the SS command is 10 and the value set by the FR command is 1, then the derivative sample period will be:
(1+1) * 10 * 0.000100 = .002000 S or 2 mS
This command is useful in tuning the PID servo loop to the inertial properties of the system.
Related Commands: RI, SS
20
Page 16
SMAC LAC-25 Technical Reference Manual
Command: aFVn -- Feed-forward, Velocity --
Argument: 0 <= n <= 32767 Default: 0
This command allows for the adjustment of the PID digital filter velocity feed-forward term for servo axis 'a'.
During the course of a Position Mode (PM) or Velocity Mode (VM) move, at any point along the way (with a consistent load), the ideal required value of the servo output is fairly consistent and somewhat predictable.
During acceleration or deceleration:
OUTPUT = (VELOCITY * FV_CONSTANT) + (ACCELERATION * FA_CONSTANT)
During constant velocity:
OUTPUT = (VELOCITY * FV_CONSTANT)
If this value can be dynamically predicted and summed with the output of the PID digital filter, i n effect, it reduces the burden of the PID filter to make lead/lag corrections based of the following error, thereby enhancing performance.
Related Commands: FA, OM, OO
Command: aGRn -- Gear Ratio --
Argument: -8388607 <= n <= 8388607 Default: 0
This command sets the electronic gearing ratio for axis 'n'. A negative argument will cause a direction reversal in the electronic gearing. The argument to this command is the desired gearing ratio scaled by 65536.
Examples:
GR65536 ; Slave gear ratio is 1:1 GR131072 ; Slave gear ratio is 2:1 GR32768 ; Slave gear ratio is .5:1 GR6554 ; Slave gear ratio is .1:1 (actual gear ratio is
; .100006103516:1).
GR-65536 ; Slave ratio is 1:1 with direction reversal
Related Commands: EG
21
Page 17
SMAC LAC-25 Technical Reference Manual
Command: aILn -- Set Integration Limit --
Argument: 0 <= n <= 16,383 Default: 0
This command clamps the level of influence that the PID digital filter integral term can use to reduce the static position error of servo axis 'a'. When properly adjusted, this can enhance loop stability and operation. The Integral Limit (IL) and Set Integral Gain (SI) must both be set to a non­zero value in order for the integral term to have any effect.
Related Commands: SI
Command: aLFn -- Limit Switch Input Off --
Argument: 0 <= n <= 3 Default: 0
This command disables one or more of the limit switch inputs for servo axis 'a'. The valid arguments to this command determine which inputs will be disabled and are as follows:
n Limit Switch Inputs Disabled
0, 3 or no argument
1 Limit+ 2 Limit-
Limit+ and Limit-
Related Commands: LM, LN
Command: aLMn -- Limit Switch Input Mode --
Argument: 0 <= n <= 3 Default: 0
This command is used to select how the LAC-25 will react when a limit switch is activated for servo axis 'a'. The valid arguments for this command are as follows:
n Action 0 Turn servo off, continue commands
1 Stop abruptly, continue commands 2 Decelerate smoothly, continue
commands
3 Interrupt only
In all cases, the Error flag in the status word will be set. This will prevent the LAC-25 from moving the servo until the flag is cleared by issuing the Motor On (MN) command. Before this command will have any effect, the limit switch must be enabled with the Limit Switch On command (LN).
Related Commands: LF, LN
22
Page 18
SMAC LAC-25 Technical Reference Manual
Command: aLNn -- Limit Switch Input On --
Argument: 0 <= n <= 3
This command is used to enable one or both of the limit switch inputs for servo axis ÔaÕ. Once enabled, the servo will be stopped or turned off if a limit switch input goes active. At the same time the Limit Switch Tripped and Error Flags will be set in the status word. These flags will remain set until the servo is turned back on with the Motor On (MN) command. Once the servo is turned back on, it can be moved out of the limit switch region with any of the standard motion commands. The argument to this command determines which of the limit switch inputs will be enabled. The coding is as follows:
n Limit Switch Inputs Enabled 0,3 or no argument Limit+ and Limit-
1 Limit+ 2 Limit-
Related Commands: LF, LM
Command: aOMn -- Output Mode --
Argument: 0 <= n <= 255 Default: 0
This command allows the user to determine what data gets sent to the D/A analog output for a given axis. The upper four bits of the argument are for redirection of data and determine from which axis the D/A channel will get itÕs data. This allows both D/A channels to output data from the same axis. If no redirection is specified, the default data used is that of the current axis.
Note: When outputting the servo output command, if no redirection is specified, then the output
command as phase adjusted by the PH command will be output. If redirection is specified,
then the normalized data as reported by the TQ command will be output.
ÔnÕ Value Output
0 Servo Output Command 1 Servo Following Error Ôn+Õ Redirect Channel 2 Servo Following Error * 64 0 Default
3 Variable USER1 16 1 4 Low Bits of Encoder Position 32 2
5 Reserved 6 Reserved 7 Reserved
Examples:
1OM0 ; Send axis 1 servo output command to D/A channel 1. 1OM16 ; Send axis 1 servo output command to D/A channel 1.
2OM0 ; Send axis 2 servo output command to D/A channel 2. 2OM32 ; Send axis 2 servo output command to D/A channel 2.
1OM0 ; Send axis 1 servo output command to D/A channel 1. 2OM17 ; Send axis 1 following error to D/A channel 2.
23
Page 19
SMAC LAC-25 Technical Reference Manual
Command: aOOn -- Output Offset --
Argument: -32767 <= n <= 32767 Default: 0
This command allows the user to set a continuous output for servo axis ÔaÕ. In certain applications, such as an overhanging load, there will be a continuous burden placed upon a servo axis. In cases like these, where there is a predictable load, the OO command can be used to provide a continuous restoring force that will be combined with the output of the PID digital filter. This has the affect of improving the performance of the PID digital filter in that because it is not saturated with static load, it has a better dynamic response to load disturbances.
Related Commands: FA, FV, OM
Command: aPHn -- Set Servo Phasing --
Argument: 0 <= n <= 63 Default: 0
This command is used to set the output polarity, encoder phasing, Index input sense, Home input sense, Limit+ and Limit- input sense for servo axis ÔaÕ. The polarity of the output will determine whether the servo is driven in a direction that reduces or increases position error. The encoder phase will determine whether the position count will increase or decrease for a valid encoder input sequence. The Index sense determines what logic edge will cause the Index input to be active. The Limit+, Limit- and Home sense determines whether these signals are active ÒonÓ or active Òoff.
To determine the argument to be used with the PH command, use the follow table and add the required values together.
Add to 'n'
Output Phase Normal 0 Output Phase Reversed 1 Encoder Phase Normal 0 Encoder Phase Reversed 2 Index Active Level Low 0 Index Active Level High 4 Home Sense Active "ON" 0 Home Sense Active "OFF" 8 Limit+ Sense Active "ON" 0 Limit+ Sense Active "OFF" Limit- Sense Active "ON" 0 Limit- Sense Active "OFF" 32
For example, if it were necessary to reverse the encoder phasing and to set the Limit+ and Limit- inputs to active "OFF", then 'n' would be (2 + 16 + 32) or 50. The default phasing and sense is equivalent to issuing this command with a argument of 0.
16
24
Page 20
SMAC LAC-25 Technical Reference Manual
Command: aRIn -- Sampling Rate of Integral --
Argument: 0 <= n <= 127 Default: 0
This command allows for the adjustment of the PID digital filter integral sampling interval for servo axis 'a'. The period of this interval can be calculated by the following:
T = (n+1) * S * 0.000100
where "T" is the period in seconds, "n" is the RI command argument and "S" is the sample period count specified by the Servo Speed (SS) command. For example, if the value previously set by the SS command is 10 and the value set by the RI command is 1, then the integral sample period will be:
(1+1) * 10 * 0.000100 = .002000 S or 2 mS
This command is useful in tuning the PID servo loop to the inertial properties of the system.
Related Commands: FR
Command: aSAn -- Set Acceleration --
Argument: 0 <= n < 1,073,741,823 Default: 0
This command sets the acceleration rate for servo axis 'a'. The 32 bit argument to this command is scaled by 65536. This number determines how much the servo's velocity will be altered by each servo loop interval (determined by the Servo Speed "SS" command) while it is accelerating or decelerating. If this command is executed during a Position Mode move, it will be ignored.
Example:
Encoder: 500 lines or 2000 Counts/Rev Desired Acceleration: 75 Rev/Sec2 Servo Loop Interval: 1,000 Hz
9830.4 = ((75 Rev/Sec * 2000 Counts/Rev) / 1000 Hz2) * 65536
To achieve an acceleration of 75 Rev/Sec2, the command SA9830 would be issued. A simpler way to calculate the acceleration argument would be to determine a constant for your application by which to calculate desired acceleration.
131.072 = K = ((1 Rev/Sec * 2000 Counts/Rev) / 1000 Hz2) * 65536
9830.4 = 75 Rev/Sec * K
Please note that if the Set Acceleration (SA) command is used with an argument of "0", then you have commanded the velocity to change in steps of zero which means if the servo is stopped it will not be able to move, and if the servo is moving it will not be able to change velocity.
Related Commands: SS, SV
25
Page 21
SMAC LAC-25 Technical Reference Manual
Command: aSCn -- Set Current Mode Gain --
Argument: 0 <= n <= 32,767 Default: 0
This command sets the "current mode" gain for servo axis 'a' used by Torque Mode (QM1 only, see QM command). This allows the response of the current error integrator to be adjusted to suit a given application. A low SC value will provide slow response to load changes while a high SC value will provide quick response to load changes. If SC is set is too low then inadequate control may occur. If the SC setting is too high then the system may be unstable. A good "general" value for SC is about 8000.
Related Commands: QM, SQ
Command: aSDn -- Set Derivative Gain --
Argument: 0 <= n <= 32,767 Default: 0
This command sets the derivative gain term of the PID digital filter loop for servo axis 'a'.
Related Commands: SG, SI, IL
Command: aSGn -- Set Proportional Gain --
Argument: 0 <= n <= 32,767 Default: 0
This command sets the proportional gain term of the PID digital filter loop for servo axis 'a'.
Related Commands: SI, SD, IL
Command: aSIn -- Set Integral Gain --
Argument: 0 <= n <= 32,767 Default: 0
This command sets the integral gain term of the PID digital filter loop for servo axis 'a'. The Set Integral Gain (SI) and Integral Limit (IL) must both be set to a non-zero value in order for the integral term to have any effect.
Related Commands: SG, SD, IL
26
Page 22
SMAC LAC-25 Technical Reference Manual
Command: aSQn -- Set [Maximum] Torque Level --
Argument: -32,767 <= n <= 32,767 in Torque Mode 0 (QM0)
-1,023 <= n <= 1,023 in Torque Mode 1 (QM1) 0 <= n <= 32,767 in Position Mode (PM) 0 <= n <= 32,767 in Velocity Mode (VM)
Default: 32,767
For servo axis 'a', this command sets the maximum output level when in Position Mode (PM) or Velocity Mode (VM) and sets the desired output level when in Torque Mode (QM). When this command is issued in Position Mode (PM) or Velocity Mode (VM), its limiting effect will remain, in all modes of operation, until again changed. Note that an argument less than zero is allowed only in Torque Mode (QM).
Examples:
>PM,SQ20000<CR> ; Set maximum output to +-20000.
>VM,SQ10000<CR> ; Set maximum output to +-10000.
>QM,SQ20000<CR> ; Set output to forward 20000.
>QM,SQ-10000<CR> ; Set output reverse 10000.
>PM,SQ10000<CR> ; Set maximum output to +-10000. >QM0,SQ15000<CR> ; Set output to forward 15000 but
Related Commands: PM, QM, SC, VM
; will only achieve output of 10000 ; due to previous command.
27
Page 23
SMAC LAC-25 Technical Reference Manual
Command: SSn -- Set Servo Speed --
Argument: 1 <= n <= 255 Default: 2
This command sets the servo loop interval, which is the same for both axis' of the LAC-25. The period of this interval can be calculated by the following:
T = (n) * 0.000100
where "T" is the period in seconds and "n" is the SS command argument. For example, if the value set by the SS command is 10 then the servo loop period will be:
10 * 0.000100 = .001000 S or 1 mS
The minimum servo loop rate is 100 µS per enabled axis. The following table shows t he minimum servo loop times:
# Axis
Enabled
0 100µS 1 100µS 2 200µS
Using the SS command affects the Set Velocity (SV) and Set Acceleration (SA) commands in that they both are specified in terms of servo loop intervals. For example, if the servo loop rate is doubled, the velocity and acceleration would appear to have been halved. It should also be noted that the "SS" command will most likely affect the required settings of the PID digital filter.
Related Commands: SA, SV
Minimum Loop Time
28
Page 24
SMAC LAC-25 Technical Reference Manual
Command: aSVn -- Set Maximum Velocity --
Argument: 0 <= n < 1,073,741,823 Default: 0
This command sets the desired velocity (in quadrature counts per servo loop interval) for servo axis 'a'. The 32 bit argument to this command consists of a 16 bit integer part and a 16 bit fractional part.
Example:
Encoder: 500 lines, 2000 Counts/Rev Desired Velocity: 40 Rev/Sec Servo Loop Interval: 1,000 Hz
5242880 = ((40 Rev/Sec * 2000 Counts/Rev) / 1000 Hz) * 65536
To achieve a velocity of 40 Rev/Sec, the command SV5242880 would be issued. A simpler way to calculate the velocity would be to determine a constant for your application by which to calculate desired velocity.
131072 = K = ((1 Rev/Sec * 2000 Counts/Rev) / 1000 Hz) * 65536
5242880 = 40 Rev/Sec * K
Related Commands: SA, SS
29
Page 25
SMAC LAC-25 Technical Reference Manual
4.2 Reporting Commands
The reporting commands output data relevant to the operating status of the LAC-25. Numerical output will be in the mathematical base determined by the Decimal Mode (DM) / Hexadecimal Mode (HM) commands and output will be followed by a carriage return and linefeed.
Command: TAn -- Tell Analog to Digital Channel 'n' --
Argument: 0 <= n <= 9
This command will cause a conversion on A/D channel 'n' and will display the result.
Related Commands: GA
Command: aTB -- Tell Breakpoint --
Default: "None"
This command reports the last programmed breakpoint value specified by the Interrupt on Position Absolute (IP) or the Interrupt on Position Relative (IR) commands for servo axis 'a'. If no breakpoint value has yet been specified then the word "NONE is returned.
Related Commands: IP, IR
Command: TCn -- Tell State of I/O Channel 'n' --
Argument: 0 <= n <= 63 Default: "Off"
This command reports the current state of the I/O channel specified by 'n' and what type of logic the channel is (either active "on" or active "off"). The display is formatted as follows:
/xx = aaa
The presence of the "/" character indicates that a channel is active in the "off" state. A lack of the "/" character indicates that the channel is active in the "on" state. The "xx" indicates the channel number and the "aaa" indicates the channel's current state, either "ON" or "OFF". T he following examples show all the possible combinations:
01 = ON ; Channel 1 is "ON" in the active "ONÓ state. /01 = ON ; Channel 1 is "ON" in the active "OFF" state. 01 = OFF ; Channel 1 is "OFF" in the active "ON" state. /01 = OFF ; Channel 1 is "OFF" in the active "OFF" state.
Related Commands: CF, CH, CL, CN
30
Page 26
SMAC LAC-25 Technical Reference Manual
Command: aTD -- Tell Derivative Gain --
This command reports the derivative gain value of the PID digital filter for servo axis 'a'.
Related Commands: TG, TI, TL
Command: TE -- Tell Error --
This command reports the last error code caused by any command or macro. If no error has occurred then a "0" will be reported. Once the TE command has been issued, then the error code will be reset to zero. The TE command is useful for determining what error occurred in the case that no display was connected at the time.
Command: aTF -- Tell Following Error --
This command reports the following error for servo axis 'a'. This value is the difference between the current desired temporal position (or that which is reported by the Tell Optimal (TO) command) of the trajectory generator and the servo's current real position (or that which is reported by the Tell Position (TP) command).
Related Commands: DB
Command: aTG -- Tell Proportional Gain --
This command reports the proportional gain value of the PID digital filter for servo axis 'a'.
Related Commands: TI, TD, TL
Command: aTI -- Tell Integral Gain --
This command reports the integral gain value of the PID digital filter for servo axis 'a'.
Related Commands: TG, TD, IL
31
Page 27
SMAC LAC-25 Technical Reference Manual
Command: aTKn -- Tell (K) Constants --
Argument: 0 <= n <= 1
This command will display a number of internal settings depending on the value specified by 'n'. If 'n' is "0" or is not specified, then various parametric values for the servo axis specified by 'a' will be displayed. If 'n' is "1", then various system parameters will be displayed.
Example display for the command "1TK0":
>1TK0
Parameter Values for Axis [1]
Proportional Gain ---------- (SG) = 0 Integral Gain -------------- (SI) = 0 Derivative Gain ------------ (SD) = 0 Integral Limit ------------- (IL) = 0 Current Gain --------------- (SC) = 0 Velocity Feed-forward Gain - (FV) = 0 Accel. Feed-forward Gain --- (FA) = 0 Output Offset -------------- (OO) = 0 Position Error Dead-Band --- (DB) = 0 Maximum Following Error ---- (SE) = 16383 Integral Sample Rate ------- (RI) = 0 Derivative Sample Rate ----- (FR) = 0 Phase and Sense Settings --- (PH) = 0 Maximum Velocity ----------- (SV) = 0 Acceleration --------------- (SA) = 0 Desired Direction ---------- (DI) = 0 Torque (output) Limit ------ (SQ) = 32767 Axis Type ------------------ (OM) = 0
Example display for the command "TK1":
>TK1
System Parameter Settings (group 1).
Axis 1 Enabled ------------- (EA) = Yes Axis 2 Enabled ------------- (EA) = Yes Base 16 Input & Output -- (HM/DM) = Off Character Echo ---------- (EN/EF) = On Handshake --------------- (HN/HF) = Off Fail -------------------- (FN/FF) = Off Servo Loop Rate ------------ (SS) = 2 Input Debounce/Delay ------- (ID) = 0 Phase and Sense Settings --- (CV) = 0 Intr. Vector Enable, HIGH (EV/DV) = 0 Intr. Vector Enable, LOW (EV/DV) = 0 Firmware Revision ---------- (VE) = 3.30
32
Page 28
SMAC LAC-25 Technical Reference Manual
Command: aTL -- Tell Integration Limit --
This command reports the integration limit value of the PID digital filter for servo axis 'a'.
Related Commands: TG, TI, TD
Command: TMn -- Tell Macros --
Argument: -2 <= n <= 255
The Tell Macro (TM) command will display the commands which make up any macros that have been defined. If 'n' >= 0 and 'n' <= 255, then the macro specified by 'n' be displayed. If 'n' = ­1, then all the macros will be displayed preceded by the individual macro number. If 'n' =-2, then all macros will be displayed and will be preceded by the letters "MD" and the individual macro number. This is useful when downloading programs from the LAC-25 to a computer in that you need not re-enter the Macro Define (MD) command and number at the beginning of each macro.
Related Commands: MD, RM
Command: aTO -- Tell Optimal Position --
This command reports the desired position for servo axis 'a'. This value may be different from the position reported by the TP command if the servo is moving or the controller is unable to drive the servo.
Related Commands: TT, TP
Command: aTP - Tell Real Position --
This command reports the absolute position of servo axis 'a'. It may be used to monitor motion during both the Motor On (MN) and the Motor Off (MF) states.
Related Commands: TT, TO
Command: aTQ -- Tell Torque --
his command reports the current output torque being commanded for servo axis 'a'. This value will be either that which is generated by the PID output or which is set by the user via the Torque Mode (QM).
Command: TRn -- Tell Contents of Register 'n' --
Argument: 0 <= n <= 511
This command reports the value contained by Register 'n'.
Related Commands: Register Commands
33
Page 29
SMAC LAC-25 Technical Reference Manual
Command: aTS -- Tell Status Word --
This command reports the operating status word of servo axis 'a'. The response is coded into a single 32 bit value. The meaning of each bit is listed below:
Bit Purpose
0 Servo Enabled. This bit will be set to Ò1Ó when the servo is enabled
via the Motor On (MN) command. A Ò0Ó indicates that the servo has been disabled via one of the following reasons: a Motor Off (MF) command, a servo error due to excessive following error or over temperature condition, a limit event, an external fault.
1 Servo Error. A Ò1Ó in this bit position indicates that the maximum
servo following error or over-temperature condition has occurred, or the external fault has been activated.
2 Over Temperature. A Ò1Ó in this bit position indicates that an over-
temperature condition has occurred or the external fault input has been activated.
3 Breakpoint Reached. A Ò1Ó in this bit position indicates that a
previously defined breakpoint has been reached. This bit will be reset by any of the following commands: Motor On (MN), Interrupt on Position (IR), Interrupt on Relative Position (IR).
4 Trajectory Complete. A Ò1Ó in this bit position indicates that the servo
has completed a commanded move. A Ò0Ó indicates that the servo is busy executing a commanded move.
5 Servo Stopping. A Ò1Ó in this bit position indicated that the servo has
been commanded to stop. Upon stopping, this bit is then cleared.
6 Current Direction. This bit indicated the current direction of travel for
the servo. (0 = Positive, 1 = Negative)
7 Desired Direction. This bit indicates the direction commanded by
the Direction (DI) command. (0 = Positive, 1 = Negative) 8 Reserved. 9 Reserved. 10 Looking for Index. A Ò1Ó in this bit position indicates that the IMCSA
is currently watching for an index pulse to occur as commanded by
the Find Index (FI) command. 11 Looking for Edge. A Ò1Ó in this bit position indicates that the IMCSA
is currently watching for the Coarse Home input to go active as
commanded by the Find Edge (FE) command. 12 Reserved. 13 Coarse Home Input Active. A Ò1Ó in this bit position indicates that the
Coarse Home input is active. 14 Capture Index Flag. A Ò1Ó in this bit position indicates that the Find
Index (FI) command is trying to capture the position on occurrence of
an index pulse as opposed to initializing the position. 15 Reserved. 16 Accelerating.? A Ò1Ó in this bit position indicates that the servo is
currently accelerating. 17 Position Mode. A Ò1Ó in this bit position indicates that the servo is
currently operating in position mode. 18 Velocity Mode. A Ò1Ó in this bit position indicates that the servo is
currently operating in velocity mode. 19 Torque Mode. A Ò1Ó in this bit position indicates that the servo is
currently operating in (voltage) torque mode. 20 Current Mode. A Ò1Ó in this bit position indicates that the servo is
currently operating in (current) torque mode). 21 Reserved.
34
Page 30
SMAC LAC-25 Technical Reference Manual
22 Electronic Gearing Mode. A Ò1Ó in this bit position indicates that the
servo is currently operating in electronic gearing mode. 23 Reserved. 24 Limit Mode Abort. Used by Limit Mode (LM) to determine what action
to take upon the occurrence of a limit switch event. 25 Limit Mode Stop. Used by Limit Mode (LM) to determine what action
to take upon the occurrence of a limit switch event. 26 Limit- Tripped. A Ò1Ó in this bit position indicates that a Limit- input
event has occurred and has been acted upon as set by the Limit
Mode (LM) command. 27 Limit- Enabled. A Ò1Ó in this bit position indicates that the Limit- input
has been enabled for action via the Limit Mode (LM) command. 28 Limit- Active. A Ò1Ó in this bit position indicates that the Limit- input is
currently active. 29 Limit+ Tripped. A Ò1Ó in this bit position indicates that a Limit+ input
event has occurred and has been acted upon as set by the Limit
Mode (LM) command. 30 Limit+ Enabled. A Ò1Ó in this bit position indicates that the Limit+
input has been enabled for action via the Limit Mode (LM)
command. 31 Limit+ Active. A Ò1Ó in this bit position indicates that the Limit+ input
is currently active.
Command: aTT -- Tell Target Position --
This command reports the current target position of servo axis 'a'. This is the absolute position to which the servo was last commanded to move. It may have been specified directly with the Move to Position (MP) or Move Absolute (MA) commands or indirectly with the Move Relative (MR) command. If the servo axis is in Velocity Mode (VM), then the target position will track the current optimal position (or that which is reported by the Tell Optimal (TO) command).
Related Commands: TO, TP
Command: aTV -- Tell Current Velocity --
This command reports the trajectory generator current velocity for servo axis 'a'. The value reported has the same units as the Set Velocity (SV) command. See the description of that command for further details.
Related Commands: SV, SS
35
Page 31
SMAC LAC-25 Technical Reference Manual
Command: VE -- Tell Version --
This command reports the firmware revision level. This revision level exists as a code in the internal RAM memory (see Register Commands). This code should be interpreted as the first byte being the major revision number and second byte being the minor revision number. This allows user programs to determine the firmware revision for compatibility purposes.
Related Commands: Register Commands
36
Page 32
SMAC LAC-25 Technical Reference Manual
4.3 Motion Commands
Motion Commands are those commands that involve or cause the actual movement of a servo. Any position mode (PM) based motion will be carried out using a trapezoidal velocity profile with the maximum velocity determined by the Set Velocity (SV) command. The acceleration and deceleration are the same and both are determined by the Set Acceleration (SA) command.
During the execution of a Position Mode based motion, the target position (MA or MR) and
the maximum velocity (SV) may be changed at any time, however, changes to the acceleration (SA) will be ignored. If a velocity mode (VM) based motion is under way, the maximum velocity
(SV) and the acceleration (SA) may be changed at any time. During this type of motion, the target position will continuously be set equal to the current optimal position. If a torque mode (QM) based motion is under way, the torque setting (SQ) may be changed at any time. During this type of motion, the target and optimal positions will continuously be set equal to the current real position. In either PM, VM or QM, a Stop (ST) or Abort (AB) command will cause motion for the specified servo axis to cease. If a servo axis is in Position Mode (PM) and is commanded into Velocity Mode (VM), the motion will continue (only with no target destination) at the current maximum velocity set by the Set Velocity (SV) command. If a servo axis is in PM or VM and commanded into Torque Mode (QM), the servo output will be reduced to zero, and the unit will be placed in QM. If a servo axis is in VM and commanded into PM, the servo will be stopped at the current acceleration rate and placed into the PM mode. If a servo axis is in QM and commanded into VM, it will attempt to instantly assume the last known maximum velocity and remain in VM. If a servo axis is in QM and commanded into PM, the output will be reduced to zero, and the servo will begin station keeping in PM.
There is another mode of operation referred to as "Electronic Gearing Mode". This mode is a supplement to the position based modes of operation. Electronic gearing causes the servo axis for which it is in effect (or the slave axis), to move proportionally to the servo axis it is tracking (or the master axis) in conjunction with it's own motion profile. The proportion of the slave axis it set by the Gear Ratio (GR) command.
When the EG command is issued, the relative position of the master axis (from the time of the EG command), is monitored by the slave axis. This relative motion is multiplied by the value set with the GR command and the product of which is added to the optimal temporal position of the slave axis. The result of this is to allow the motion profile of the master servo axis to b e superimposed on the slave axis' motion profile. While the EG mode is primarily intended for use with axis' that are operating in position mode (PM), it will also work with axis' that are operating i n velocity mode (VM).
Command: aAB -- Abort Motion --
This command causes an emergency stop on servo axis 'a'. The servo stops abruptly but leaves the servo control loop enabled. The target position is changed to be equal to the present position. The command is used for stopping an undesired motion.
Related Commands: ST
37
Page 33
SMAC LAC-25 Technical Reference Manual
Command: aCI -- Capture on Index --
This command causes the position counter of servo axis 'a' to be stored in the internal variable HREG upon receipt of an index pulse. For more information on HREG, see the Register Commands and the listing of the internal variables.
Related Commands: FI, WI
Command: aDA -- Enable Axis for Operation --
Default: Axis 1 and 2 enabled.
This command will disable operation of servo axis 'a'. Because no operation may be made on a disabled axis, the equivalent of a Motor Off (MF) command is executed before the axis is disabled.
Related Commands: EA
Command: aDHn -- Define Home --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command causes the current position of the servo axis 'a' to be defined as 'n'. From then on, all positions used and reported for the servo axis will be relative to that physical position.
Related Commands: FE, FI
Command: aDIn -- Set Direction --
Argument: n = 0 for positive, n = 1 for negative Default: 0
This command sets the move direction for servo axis 'a' when in velocity mode. Issuing this command with an argument of "0" will cause the servo to move in a positive direction while an argument of "1" will cause it to move in a negative direction.
Related Commands: SA, SV, VM
38
Page 34
SMAC LAC-25 Technical Reference Manual
Command: aEA -- Enable Axis for Operation --
Default: Axis 1 and 2 enabled.
This command will enable operation of servo axis 'a'. If an axis is not enabled for operation, no system resources will be expended on it. For example, this means that if an axis is going to be used for it's encoder interface only, it must still be enabled for operation via the EA command, however, the undedicated encoder interface is always enabled and does not apply here.
Before using the EA command, one should be sure that the Set Servo Speed (SS) command has been used such that the servo loop time is long enough to service the newly enabled axis as well as any previously enabled axis'.
Related Commands: DA
Command: aEGn -- Electronic Gearing Mode --
Argument: -2 <= n <= 2 Default: Position Mode
This command causes (slave) servo axis 'a' to begin to move proportionally to (master) servo axis 'n'. If 'n' is "0" then the electronic gearing mode for axis 'a' will be disabled. If 'n' is positive then the slave axis will track the master axis' optimal position (or that which is reported by the TO command). If 'n' is negative then the slave axis will track the master axis' real position (or that which is reported by the TP command). It is preferable that the EG command only be used when the target (or slave) axis is not in motion.
Related Commands: GR
Command: aFEn -- Find Edge of Coarse Home Input --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command is used to initialize servo axis 'a' at a given position. It will remain in effect until the Home input goes active. At that time, the current position of the servo will be defined as 'n'. This command will neither start nor stop any servo motion. It is up to the user to initiate servo motion before issuing the command and to stop any motion after the command is completed.
Related Commands: WE
39
Page 35
SMAC LAC-25 Technical Reference Manual
Command: aFIn -- Find Edge of Index --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command is used to initialize servo axis 'a' at a given position. It will remain in effect until the Index input goes active. At that time, the current position of the servo will be defined as 'n'. Like the Find Edge (FE) command, this command will not start or stop any servo motions; that is up to the user. Since an index pulse may occur at numerous points of the servo's travel (once per revolution in rotary encoders), a typical application will require a home signal to establish a coarse position reference before the index pulse can be used to fine tune that reference.
Related Commands: CI, WI
Command: aGH -- Go Home --
This command causes servo axis 'a' to move to absolute position 0. This is equivalent to a Move Absolute (MA) command when the destination is 0. This command will initiate motion; therefore, a Go (GO) command is not required.
Related Commands: MA, GO
Command: aGO -- Go (start motion) --
This command causes servo axis 'a' to begin motion. When in the Velocity Mode (VM), the axis will accelerate to a constant velocity. When in the Position Mode (PM) the axis will begin to seek the specified target position. The servo must be in the "on" state for motion to occur.
Related Commands: MA, MR, PM, VM
Command: aMAn -- Move Target Absolute --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command sets the target position of servo axis 'a' to absolute position 'n'. The absolute position is relative to the point of initialization (home or 0). As the Move Absolute (MA) command will not initiate a motion, a Go (GO) command must be used. The servo's target position will be adjusted whether the servo is on or off.
Related Commands: GO, MR, PM
Command: aMF -- Motor Off --
This command is used to place servo axis 'a' in the "off" state. The servo's output will go to the null level. This command can be used to prevent unwanted motion or to allow manual positioning of the unit. When the servo is turned off, the target and the optimal positions will follow the real position.
Related Commands: MN
40
Page 36
SMAC LAC-25 Technical Reference Manual
Command: aMN -- Motor On --
This command is used to place servo axis 'a' in the "on" state. When the servo is turned on, its target position is set to its current position so that the servo is not inclined to move. When this command is issued, it will disable the Home and Index interrupt sources and will reset the Error, Fault, Breakpoint reached, Looking for Edge, Looking for Index and Limit Tripped bits in the status word for axis 'a'.
Related Commands: LM, LN, MF
Command: aMRn -- Move Target Relative --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command generates a relative target position of 'n' counts for servo axis 'a'. Since the Move Relative (MR) command will not initiate a motion, a Go (GO) command must be used. The servo's target position will be adjusted whether the servo is on or off.
Related Commands: GO, MA, PM
Command: aPM -- Enter Position Mode --
Default: Position mode
This command causes servo axis 'a' to enter the position mode of operation. In this mode, the servo can be commanded to move to a specific target position. The moves will be executed using a trapezoidal velocity profile based upon parameters set by the Set Velocity (SV) and the Set Acceleration (SA) commands.
Related Commands: EG, QM, VM
41
Page 37
SMAC LAC-25 Technical Reference Manual
Command: aQMn -- Enter Torque Mode --
Argument: 0 for voltage mode, 1 for current mode Default: Position mode
This command places servo axis 'a' in the Torque Mode of operation. For mode 0 (or QM0), the output PWM duty cycle (or analog output for appropriate models) can be manually controlled by the user program. Once QM0 has been entered, the Set Torque (SQ) command can be used to set or change the servo output (see the SQ command). Bear in mind, that if the output was being limited by an SQ command before entering torque mode (while in PM or VM), it will remain limited while in QM and cannot be changed until the unit is in PM or VM.
For mode 1 (or QM1), the LAC-25 will use one of its A/D channels to monitor servo output current and attempt to maintain that output current at a steady level as commanded by the user program (see the SQ and SC commands). In that the A/D converter has 10-bit resolution, this will result in a value from 0 to 1023 which represents the instantaneous output current with 0 being approximately 0 Amps and 1023 being approximately 5 Amps with intermediate values being somewhat linear.
In the case of a motor (for example), when an output command of 512 is set (or about 2.5 amps), the PWM output begins to ramp up until the desired output current is reached. If the motor is not loaded enough to require 2.5 amps then the PWM will ramp up to 100% putting the maximum supply voltage to the motor. If at this point the motor is suddenly loaded, the PWM will ramp down to a level sufficient to supply 2.5 amps to the motor.
Mode QM1 will not function with the D/A module option.
Related Commands: EG, PM, VM
Command: aSEn -- Set Maximum Following Error --
Argument: 0 <= n <= 16,383 Default: 16,383
This command is used to set the maximum allowable following error (difference between the actual position and the optimal position) for servo axis 'a'. If the following error exceeds the programmed value, the servo will be turned off (except in the case of the related interrupt being enabled) and the Error bit in the status word for axis 'a' will be set. This bit will remain set until the servo is turned back on with the Motor On (MN) command.
Related Commands: DB, TF
Command: aST -- Stop Motion --
This command is used to terminate motion on servo axis 'a'. This command differs from the Abort (AB) command in that the servo will decelerate at its preset rate instead of stopping abruptly. When in Torque Mode, the outputs will be set to null.
Related Commands: AB, WS
42
Page 38
SMAC LAC-25 Technical Reference Manual
Command: aVM -- Enter Velocity Mode --
Default: Position mode
This command places servo axis 'a' in the Velocity Mode of operation. In this mode, the servo can be commanded to move in either direction to a maximum velocity. The servo will move in that direction until commanded to stop. When using Velocity Mode, the user must specify the direction for the servo to move using the Direction (DI) command. After specifying the desired maximum velocity and the desired direction and placing the servo in velocity mode, the servo ca n be started by issuing the Go (GO) command. While the servo is moving in Velocity Mode, the user can change the velocity by issuing new Direction (DI) and/or Set Velocity (SV) commands. The acceleration rate at which the servo's velocity will change, is determined by the Set Acceleration (SA) command. The acceleration can also be changed at any time.
Related Commands: EG, QM, PM
43
Page 39
SMAC LAC-25 Technical Reference Manual
4.4 Register Commands
The LAC-25 uses part of its nonvolatile RAM (NVRAM) to create a 512 by 32 bit general purpose register space with Register "0" being referred to as the Accumulator.
The registers have many uses including storing data and parameters, performing mathematical operations and controlling command execution. The registers can be manipulated by several commands and can also be used to replace the argument in most commands. For example, if register "6" contains the value "-12000" and the following command is used...
MA@6,GO
it would use the contents of register "6" as the argument thus giving the same result as if the following command was issued...
MA-12000
Note that the use of the "@" character is what caused the command to assume a register argument (or indirect argument) instead of a direct argument. If the value following the "@" is not in the range of the 512 registers (0 to 511), an error will be reported. If the value contained by the register of the indirect argument is out of range, an error will also be reported.
As stated earlier, because the registers are within the NVRAM, they are non-volatile and can be used as such. For example, if a register is incremented once every user program cycle, it can be used as an ongoing cycle counter for maintenance purposes, production accounting and etc.
4.4.1 Internal Variables
In certain applications, the user may find it necessary to use data pertinent to the internal operation of the LAC-25. This may be accomplished via the use of the Read Byte (RB), the Read Word (RW) and the Read Long (RL) commands which copy the LAC-25's internal RAM memory to the accumulator and the Write Byte (WB), the Write Word (WW) and the Write Long (WL) commands which copy the accumulator to the LAC-25's internal RAM memory. The listings below tell the location of and describe the internal variables that may be of use to the user.
WARNING: Randomly modifying these variables or other internal RAM not listed will most
likely affect the operation of the LAC-25 resulting in unpredictable behavior or possible damage.
44
Page 40
SMAC LAC-25 Technical Reference Manual
Axis Variable Descriptions.
Status Status word (TS command). PV Peak velocity (SV command). MPV Negative peak velocity (SV command). V Temporal velocity (TV command). Desp Desired position (TT command). Carp Temporal desired position (TO command). Ack Acceleration constant (SA command). Curp Current real position (TP command). HREG Holding register (CI,IP,IR commands). IPPOS Interrupt on position reference. QI Integral of current mode error (QM1 command). PGAIN Proportional term of PID filter (SG command). IGAIN Integral term of PID filter (SI command). DGAIN Derivative term of PID filter (SD command). IL Integral limit of PID filter (IL command). CGAIN Current mode gain (QM1 command). FVGAIN Velocity feed-forward of PID filter (FV command). BIAS Output offset (OO command). THRO Current servo output (TQ,SQ command). QCMD Current command (QM1,SQ command). TLMTPL Maximum positive servo output (SQ command). FAGAIN Acceleration feed-forward of PID filter (FA command). PERR Last calculated servo position error (TF command). OERR Old servo position error. MAXERR Maximum servo position error (SE command). I Servo error integral. DERIV Servo error derivative. IMON Servo output current monitor. INTRVL PID derivative sample interval (FR command). SMPCNT PID derivative sample counter. IINTRVL PID integral sample interval (RI command). ISMPCNTPID integral sample counter.
AXIS Axis number lookup index. ATYPE Axis output type (OM command). PHASE Phase, sense and polarity information (PH command). GMAxis Gear mode "gear to" axis (EG command). DBAND Position error dead-band (DB command). DERR Position error with dead-band. GMOFF Gear mode initial position offset (EG command). RATIO Gear mode gear ratio (GR command). USER1 User variable #1 (See OM command). FCNT Fault system counter. FCMP Fault system comparator. TLMTMI Maximum negative servo output (SQ command).
45
Page 41
SMAC LAC-25 Technical Reference Manual
System Variable Descriptions
RecRate Data recorder sample rate. RecAddr Data recorder sample address source. RecSize Data recorder sample data size. AIN0 Analog Input 0. (After TA0,GA0 command). AIN1 Analog Input 1. (After TA1,GA1 command). AIN2 Analog Input 2. (After TA2,GA2 command). AIN3 Analog Input 3. (After TA3,GA3 command). AIN4 Analog Input 4. (After TA4,GA4 command). AIN5 Analog Input 5. (After TA5,GA5 command). AIN6 Analog Input 6. (After TA6,GA6 command). AIN7 Analog Input 7. (After TA7,GA7 command). AIN8 Analog Input 8. (After TA8,GA8 command). AIN9 Analog Input 9. (After TA9,GA9 command). VERSION Version number for program use. (VE command). LST_ERR Last error code (TE command). LTIMER 1 Hz LED timer. ADSEMA A/D Interrupt system semaphores flags. SYSSTAT System status word. IPEND0 User interrupt pending level 0 -15 (EV,DV command). IPEND1 User interrupt pending level 16 - 31 (EV,DV command). SCLOCK Servo loop counter. RCLOCK 1 mS Real time clock/counter. IO_DELAY User digital input delay (ID command).
SYSSTAT Variable Bit Definitions
Bit Purpose
0 Axis 0 Enabled. This bit is set to Ò1Ó when axis 0 is enabled. 1 Axis 1 Enabled. This bit is set to Ò1Ó when axis 1 is enabled. 2 Reserved. 3 Reserved. 4 Reserved. 5 Pause. This bit is set to Ò1Ó when the space bar is used to pause a user program. 6 SXOff. This bit is set to Ò1Ó when the LAC-25 receives an XOFF code. 7 HexMod. This bit is set to Ò1Ó by the HM command and set to Ò0Ó by the DM
command. 8 Echo. This bit is set to Ò1Ó by the EN command and set to Ò0Ó by the EF command. 9 HandSh. This bit is set to Ò1Ó by the HN command and set to Ò0Ó by the HF
command.
10 Reserved. 11 Reserved. 12 Reserved. 13 Reserved. 14 Fail. This bit is set to Ò1Ó by the FN command and set to Ò0Ó by the FF command. 15 BadInp. This bit is set to Ò1Ó by the VI command to indicate an error in user input.
46
Page 42
SMAC LAC-25 Technical Reference Manual
Axis Variable Locations
Variable
Name
Status LONG PV LONG MPV LONG V LONG Desp LONG Carp LONG Ack LONG Curp LONG HREG LONG IPPOS LONG QI LONG PGAIN WORD IGAIN WORD DGAIN WORD IL WORD CGAIN WORD FVGAIN WORD BIAS WORD THRO WORD QCMD WORD TLMTPL WORD FAGAIN WORD PERR WORD OERR WORD MAXERR WORD I WORD DERIV WORD IMON WORD INTRVL BYTE SMPCNT BYTE IINTRVL BYTE ISMPCNT BYTE AXIS WORD ATYPE BYTE PHASE BYTE GMAxis BYTE DBAND WORD DERR WORD GMOFF LONG RATIO LONG USER1 WORD FCNT WORD FCMP WORD TLMTMI WORD
Type Axis #1 Address Axis #2 Address
01C0H/0448 0250H/0592 01C6H/0454 0256H/0598 01CAH/0458 025AH/0602 01CEH/0462 025EH/0606 01E0H/0480 0270H/0624 01E6H/0486 0276H/0630 01EAH/0490 027AH/0634 01EEH/0494 027EH/0638 01F8H/0504 0288H/0648 01FCH/0508 028CH/0652 0200H/0512 0290H/0656 0204H/0516 0294H/0660 0206H/0518 0296H/0662 0208H/0520 0298H/0664 020AH/0522 029AH/0666 020CH/0524 029CH/0668 020EH/0526 029EH/0670 0210H/0528 02A0H/0672 0212H/0530 02A2H/0674 0214H/0532 02A4H/0676 0216H/0534 02A6H/0678 0218H/0536 02A8H/0680 021AH/0538 02AAH/0682 021CH/0540 02ACH/0684 021EH/0542 02AEH/0686 0220H/0544 02B0H/0688 0222H/0546 02B2H/0690 0224H/0548 02B4H/0692 0226H/0550 02B6H/0694 0227H/0551 02B7H/0695 0228H/0552 02B8H/0696 0229H/0553 02B9H/0697 022AH/0554 02BAH/0698 022CH/0556 02BCH/0700 022EH/0558 02BEH/0702 022FH/0559 02BFH/0703 0230H/0560 02C0H/0704 0232H/0562 02C2H/0706 0234H/0564 02C4H/0708 0238H/0568 02C8H/0712 0240H/0576 02D0H/0720 0242H/0578 02D2H/0722 0244H/0580 02D4H/0724 0246H/0582 02D6H/0726
47
Page 43
SMAC LAC-25 Technical Reference Manual
System Variable Locations
Variable Name
RecRate WORD RecAddr WORD RecSize WORD AIN0 WORD AIN1 WORD AIN2 WORD AIN3 WORD AIN4 WORD AIN5 WORD AIN6 WORD AIN7 WORD AIN8 WORD AIN9 WORD VERSION WORD LST_ERR BYTE LTIMER WORD ADSEMA WORD SYSSTAT WORD IPEND0 WORD IPEND1 WORD SCLOCK LONG RCLOCK LONG IO_DELAY BYTE
Type Address
01A6H/422 01A8H/424 01AAH/426 0600H/1536 0602H/1538 0604H/1540 0606H/1542 0608H/1544 060AH/1546 060CH/1548 060EH/1550 0610H/1552 0612H/1554 0616H/1558 0619H/1561 061AH/1562 061CH/1564 0712H/1810 0718H/1816 071AH/1818 0722H/1826 0726H/1830 073EH/1854
Command: AAn -- Add 'n' to Accumulator (Signed) --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command adds the value 'n' to the accumulator.
Command: AC -- Accumulator Complement --
This command causes a (bit-wise) 1's complement of the accumulator.
Command: ADn -- Accumulator Divide by 'n' (Signed) --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command performs a 64 bit by 32 bit signed division with a 64 bit quotient and a 32 bit remainder. The low order 32 bits of the numerator must be in the accumulator and the high order 32 bits must be in Register 1. The divisor is specified by 'n'. The lower 32 bits of the quotient will be stored in the accumulator and the upper 32 bits will be stored in Register 1. The remainder will be in Register 2.
Related Commands: AM
48
Page 44
SMAC LAC-25 Technical Reference Manual
Command: AEn -- Exclusive-Or Accumulator with 'n' --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command causes the result of an exclusive-OR of the accumulator with 'n' to reside in the accumulator.
Command: ALn -- Load Accumulator with 'n' (Signed) --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command causes the accumulator to be loaded with the value 'n'.
Command: AMn -- Multiply Accumulator by 'n' (Signed) --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command does a signed multiply of the 32 bit contents of the accumulator and 'n',
leaving the lower 32 bits of the 64 bit product in the accumulator and the upper 32 bits in Register 1.
Related Commands: AD
Command: ANn -- And Accumulator with 'n' --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command causes the result of the accumulator ANDed with 'n' to reside in the accumulator.
Command: AOn -- Or Accumulator with 'n' --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command causes the result of the accumulator ORed with 'n' to reside in the accumulator.
Command: ARn -- Copy Accumulator to Register 'n' --
Argument: 0 <= n <= 511
This command causes the value in the accumulator to be copied to Register 'n'.
Related Commands: RA
Command: ASn -- Subtract 'n' from Accumulator (Signed)
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command causes the value 'n' to be subtracted from the accumulator.
49
Page 45
SMAC LAC-25 Technical Reference Manual
Command: RAn -- Copy Register 'n' to Accumulator --
Argument: 0 <= n <= 511
This command causes the value in Register 'n' to be copied to the accumulator.
Related Commands: AR
Command: RBn -- Read Byte (8 bits) at RAM location 'n'
Argument: 0 <= n <= 2047
This command reads the 8 bit value at internal RAM location 'n' and copies it to the low 8­bits of the accumulator while clearing the upper 24 bits.
Related Commands: RW, RL, WB, WL, WW
Command: RLn -- Read Long (32 bits) at RAM location 'n' --
Argument: 0 <= n <= 2046
This command reads the 32 bit value at internal RAM location 'n' and copies it to the accumulator. The value specified by 'n' must be evenly divisible by 2.
Related Commands: RB, RW, WB, WL, WW
Command: RWn -- Read Word (16 bits) at RAM location 'n' --
Argument: 0 <= n <= 2046
This command reads the 16 bit value at internal RAM location 'n' and copies it to the low 16-bits of the accumulator while clearing the upper 16 bits. The value specified by 'n' must be evenly divisible by 2.
Related Commands: RB, RL, WB, WL, WW
Command: SLn -- Shift Accumulator Left 'n' bits --
Argument: 0 <= n <= 31
This command causes the accumulator to be shifted left 'n' bits while filling the low order bits with zero.
Related Commands: SR
50
Page 46
SMAC LAC-25 Technical Reference Manual
Command: SRn -- Shift Accumulator Right 'n' bits --
Argument: 0 <= n <= 31
This command causes the accumulator to be shifted right 'n' bits while filling the high order bits with zero.
Related Commands: SL
Command: TRn -- Tell Contents of Register 'n' --
Argument: 0 <= n <= 511
This command reports the value contained by Register 'n'.
Command: WBn -- Write Byte (8 bits) to RAM location 'n' --
Argument: 0 <= n <= 2047
This command copies the low 8-bits of the accumulator to the internal RAM location 'n'.
Related Commands: RB, RL, RW, WL, WW
Command: WLn -- Write Long (32 bits) to RAM location 'n' --
Argument: 0 <= n <= 2046
This command copies all 32 bits of the accumulator to the internal RAM location 'n'. The value of 'n' must be evenly divisible by two.
Related Commands: RB, RL, RW, WB, WW
Command: WWn -- Write Word (16 bits) to RAM location 'n' --
Argument: 0 <= n <= 2046
This command copies the low 16-bits of the accumulator to the internal RAM location 'n'. The value of 'n' must be evenly divisible by two.
Related Commands: RB, RL, RW, WB, WL
51
Page 47
SMAC LAC-25 Technical Reference Manual
4.5 Sequence Commands
The LAC-25 includes commands that provide for conditional sequence command execution based on the register data, I/O state and etc. These Sequence Commands are illustrated by the following general forms:
If the condition is true, command execution will continue normally. If the condition is
false, the next two commands in the command line or the macro will be skipped.
If the condition is true, command execution will continue normally. If the condition is
false, the rest of the command line or the macro will be skipped.
If the condition is true, command execution will continue normally. If the condition is
false, command execution will be suspended until the condition becomes true.
Command: DFn -- Do if I/O Channel is "Off" --
Argument: 0 <= n <= 63
This command will cause command execution to continue if I/O channel 'n' is "Off"; otherwise, the rest of the command line or the macro will be skipped.
Related Commands: CF, CN, DN
Command: DNn -- Do if I/O Channel is "On" --
Argument: 0 <= n <= 63
This command will cause command execution to continue if I/O channel 'n' is "On"; otherwise, the rest of the command line or the macro will be skipped.
Related Commands: CF, CN, DF
Command: EP -- End Program --
This command will cause program execution to cease and return the ">" prompt.
Related Commands: RC
Command: IBn -- If Accumulator is Below 'n' (Signed) -
Argument: -2,147,483,647 <= n <= 2,147,483,647
If the contents of the accumulator is less than (signed comparison) the value 'n', command execution will continue; otherwise, the next two commands in the command line or the macro will be skipped.
52
Page 48
SMAC LAC-25 Technical Reference Manual
Command: ICn -- If Bit 'n' of Accumulator is Clear (0) --
Argument: 0 <= n <= 31
If bit 'n' of the accumulator is clear (equals 0), command execution will continue; otherwise, the next two commands in the command line or the macro will be skipped.
Command: IEn -- If Accumulator Equal to 'n' --
Argument: -2,147,483,647 <= n <= 2,147,483,647
If the accumulator is equal to the value 'n', command execution will continue; otherwise, the next two commands in the command line or the macro will be skipped.
Related Commands: IU
Command: IFn -- If I/O Channel is "Off" --
Argument: 0 <= n <= 63
If the I/O channel specified by 'n' is in the "off" state, command execution will continue; otherwise, the next two commands in the command line or the macro will be skipped.
Related Commands: CF, CN, IN
Command: IGn -- If Accumulator is ">" 'n' (Signed) --
Argument: -2,147,483,647 <= n <= 2,147,483,647
If the contents of the accumulator is greater than (signed comparison) the value 'n', command execution will continue; otherwise, the next two commands in the command line or the macro will be skipped.
Command: INn -- If I/O Channel is "On" --
Argument: 0 <= n <= 63
If the I/O channel specified by 'n' is in the "on" state, command execution will continue; otherwise, the next two commands in the command line or the macro will be skipped.
Related Commands: CF, CN, IF
53
Page 49
SMAC LAC-25 Technical Reference Manual
Command: aIPn -- Interrupt on Absolute Position 'n' --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command is used to determine when servo axis 'a' has achieved the specified position 'n' referenced by the home position (or zero). When that position has been reached, the "breakpoint reached" flag in the status register will be set. This command can be issued before or after the servo has been commanded to move.
Related Commands: IR, TB
Command: aIRn -- Interrupt on Relative Position 'n' --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command is used to determine when servo axis 'a' has achieved the specified position 'n' referenced by the current position when this command is executed. When that position has been reached, the "breakpoint reached" flag in the status register will be set. This command can be issued before or after the servo has been commanded to move.
Related Commands: IP, TB
Command: ISn -- If Bit 'n' of Accumulator is Set (1) --
Argument: 0 <= n <= 31
If bit 'n' of the accumulator is set (equals 1), command execution will continue; otherwise, the next two commands in the command line the or the macro will be skipped.
Related Commands: IC
Command: IUn -- If Accumulator Unequal to 'n' --
Argument: -2,147,483,647 <= n <= 2,147,483,647
If the accumulator is unequal to the value 'n', command execution will continue; otherwise, the next two commands in the command line or the macro will be skipped.
Related Commands: IE
Command: RPn -- Repeat --
Argument: 0 <= n <= 65,535
This command causes the command line to repeat 'n' more times. If 'n' is not specified or is "0", the command line is repeated indefinitely.
54
Page 50
SMAC LAC-25 Technical Reference Manual
Command: WAn -- Wait ÔnÕ milliseconds --
Argument: 0 <= n <= 65,535
This command causes a wait period of 'n' milliseconds before going on to the next command.
Command: aWEn -- Wait for Edge --
Argument: 0 or 1
This command waits until the Coarse Home Input Active bit in the status word of servo axis 'a' is at the logic state specified by 'n' before continuing command execution. If 'n' is not specified or is 0, it will wait for the Home input to go inactive. If 'n' is 1, it will wait for the Home input to go active.
Note: The argument for this command works in reverse as compared to that of the IMCSA controller.
Related Commands: FE
Command: WFn -- Wait for I/O Channel "Off" --
Argument: 0 <= n <= 63 Default: "Off"
This command waits until I/O channel 'n' is in the "off" state before continuing command execution.
Related Commands: CF, CN, WN
Command: aWI -- Wait for Index --
This command will wait for the occurrence of an Index input signal on servo axis 'a' before continuing to the next command. If a Find Index (FI) command has not been issued prior to this command, no waiting will occur.
Related Commands: CI, FI
Command: WNn -- Wait for I/O Channel "On" --
Argument: 0 <= n <= 63 Default: "Off"
This command waits until I/O channel 'n' is in the "on" state before continuing command execution.
Related Commands: CF, CN, WF
55
Page 51
SMAC LAC-25 Technical Reference Manual
Command: aWPn -- Wait for Absolute Position 'n' --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command is used to determine when servo axis 'a' has achieved the specified position 'n' referenced by the home position (or zero). Until that position has been reached, command execution will be suspended. This command can be issued before or after the servo has bee n commanded to move; however, if the servo is not moving, then command execution may be suspended indefinitely.
Related Commands: WR
Command: aWRn -- Wait for Relative Position 'n' --
Argument: -2,147,483,647 <= n <= 2,147,483,647
This command is used to determine when servo axis 'a' has achieved the specified position 'n' referenced by the current position when this command is executed. Until that position has been reached, command execution will be suspended. This command can be issued before or after the servo has been commanded to move; however, if the servo is not moving, then command execution might be suspended indefinitely.
Related Commands: WP
Command: aWSn -- Wait for Stop --
Argument: 0 <= n <= 65535
This command will wait until servo axis 'a' has stopped moving for 'n' milliseconds before continuing to the next command. So that there is only one delay period, in the case where 'n' is specified as "0", the command will wait for all servo axis' to stop moving before the delay is executed.
Related Commands: ST
56
Page 52
SMAC LAC-25 Technical Reference Manual
4.6 Learned Position Storage (LPS) Commands
The LAC-25 uses part of its nonvolatile RAM (NVRAM) to create a 256 item table for storing positions. This table overlaps the last 256 registers of the register table.
The LPS table is normally accessed by three commands: Learn Position (LP), Learn Target (LT) and Move to Position (MP). The purpose for the LPS table is to allow the user to store pre­determined positions for later use (such as in contouring) as the NVRAM will retain data even when powered down. In other cases, this table can be built through calculations using the register commands.
Command: aLPn -- Learn Current Position --
Argument: 0 <= n <= 255
This command causes the current position of servo axis 'a' (that position reported by the Tell Position (TP) command) to be stored in location 'n' of the Learned Position Storage table. This command is useful for "teaching" target positions to the LAC-25.
Related Commands: LT, MP
Command: aLTn -- Learn Target Position --
Argument: 0 <= n <= 255
This command causes the current target position of servo axis 'a' (that position reported by the Tell Target (TT) command) to be stored in the location 'n' of the Learned Position Storage table. This command is useful for setting up a table of target positions via a downloading procedure.
Related Commands: LP, MP
Command: aMPn -- Move to Index Table Position 'n' --
Argument: 0 <= n <= 255
This command causes the position contained by the Learned Storage Position table location 'n' to become the new target position. This command will not initiate a motion; therefore, a Go (GO) command may be required.
Related Commands: LP, LT
57
Page 53
SMAC LAC-25 Technical Reference Manual
4.7 Macro Commands
Command instructions can be entered and executed immediately, but the LAC-25 also has the capability of using commands to form other commands called "macros". These macros are stored in the nonvolatile RAM (NVRAM) and can be executed automatically. Macros are created by stringing together one or more commands (with arguments), separated by commas, and indicating where they are to be stored. It should be noted that macros can use indirect as well as direct arguments. The LAC-25 allows for the creation of 256 macros consisting of a total of nearly 2,300 command instructions. Macro calls via the Macro Call (MC) command or the interrupt system, may be nested up to 25 calls deep.
An example of a macro might be...
>MD5,SV1000000,SA10000,MA25000,GO,WS100<CR>
Once this command line is entered, it will become the definition for macro 5. When macro 5 is used via the Macro Call (MC), Macro Sequence (MS) or Macro Jump (MJ) commands, the commands contained within the macro will be executed automatically.
There are a few necessary restrictions when creating macros. When using the Macro Define (MD) command, it must be placed first in the command line and it may be used only once. This also implies that it cannot be used as part of a macro. The Reset Macro (RM) command is similar in that it too cannot be used as part of a macro.
Another feature of the LAC-25 is the ability to automatically execute macro "0" on power­up or after a Reset (RT) command. If macro "0" is not defined, the user will receive the ">" prompt, and the LAC-25 will wait for manual input.
Command: DVn -- Disable Interrupt Vector 'n' --
Argument: 0 <= n <= 31
This command disables interrupt vector 'n'. This prevents any possibility of an interrupt being caused by that source.
Related Commands: EV, LV
Command: EVn -- Enable Interrupt Vector 'n' --
Argument: 0 <= n <= 31
This command enables interrupt vector 'n'. This allows the possibility of an interrupt being caused by that source.
Related Commands: DV, LV
58
Page 54
SMAC LAC-25 Technical Reference Manual
Command: JPn -- Jump to Command, Absolute --
Argument: 0 <= n <= 31
This command causes execution of a macro to jump to the absolute command specified by 'nÕ. Commands are numbered sequentially starting from 0. If 'n' is specified whereas the command would attempt to jump past the end of the macro, command execution will resume as if the macro had ended.
Related Commands: JR
Command: JRn -- Jump to Command, Relative --
Argument: 0 <= n <= 31
This command causes execution of a macro to jump to the command specified by 'n' relative to the current command location. If 'n' is specified as zero, then this command will jump to itself. If 'n' is specified such that the command would attempt to jump past the end of the macro, command execution will resume as if the macro had ended. If 'n' is specified such that the command would attempt to jump to a point before the beginning of the macro, an error will be reported.
Related Commands: JP
Command: LVn -- Load Interrupt Vector 'n' --
Argument: 0 <= n <= 31
This command loads interrupt vector table entry 'n' with the contents of the low 8-bits of the accumulator. The following program fragment will cause execution of macro "10" upon the activation of digital input 0 (while a macro program is running).
MD1,AL10 ; Load accumulator with number for macro "10". MD2,LV0 ; Load that number to interrupt vector 0. MD3,EV0 ; Enable interrupt vector 0.
MD10,MG"Input 0 was just activated.",RC
When input 0 is activated, the line "Input 0 was just activated." will be displayed.
Related Commands: DV, EV
59
Page 55
SMAC LAC-25 Technical Reference Manual
Command: MCn -- Macro Call --
Argument: 0 <= n <= 255
This command allows a previously defined macro specified by 'n' to be called like a subroutine. When this command is used, the current macro being executed is pushed to the macro stack and execution of macro 'n' begins. If macro 'n' has not been defined, then an error will be reported. After execution of the defined macro, command execution will continue immediately after the Macro Call (MC) command. The Macro Call (MC) command can be used any place in a macro. Macro calls may be nested up to 25 times; however, it is NOT advisable for a macro to call itself.
Related Commands: RC, UM
Command: MDn -- Macro Definition --
Argument: 0 <= n <= 255
This command is used to define a new macro. Any duplication of numbers will simply result in the loss of the previously defined macro using that number and the loss of the memory that it used. The Macro Define (MD) command must be the first command in the command line or an error will be reported.
Related Commands: RM, TM
Command: MJn -- Macro Jump --
Argument: 0 <= n <= 255
This command may be used to "Jump" to a previously defined macro command. Once the LAC-25 begins executing the new macro, it has no record of how it got there. This means that any commands that appear after the Macro Jump (MJ) command will not be executed. If there is no macro defined by the number 'n', an error will be reported. Once the end of the macro is encountered, macro execution stops (See the Macro Sequence (MS) command). The Macro Jump command can be used any place in a command string or macro command. It is also acceptable for a macro to jump to itself.
Related Commands: MC, MS
Command: MSn -- Begin Macro Sequence --
Argument: 0 <= n <= 255
This command will cause macros to be executed sequentially beginning with macro 'n' until an undefined macro or an End Program (EP) command is encountered. This command can be used anywhere in a command string or macro command. If the Macro Jump (MJ) or Macro Call (MC) commands are encountered, macro execution will still continue to execute sequentially.
Related Commands: MC, MJ
60
Page 56
SMAC LAC-25 Technical Reference Manual
Command: RC -- Return from Macro Call --
When executed, this command will cause immediate return to the calling macro (assuming there was one).
Related Commands: MC, interrupts
Command: RMn -- Reset Macro(s) --
Argument: 0 <= n < 255
This command is used to delete one or more macros. If an argument is used, the macro specified by 'n' will be deleted and the memory it used will be lost. If no argument is used, all macros will be deleted, and all macro memory will be recovered. A Reset Macro command (RM) should be used before entering or downloading a new set of macro commands.
Related Commands: MD
Command: TMn -- Tell Macros --
Argument: -2 <= n <= 255
The Tell Macro (TM) command will display the commands which make up any macros that have been defined. If 'n' >= 0 and 'n' <= 255, then the macro specified by 'n' be displayed. If 'n' = ­1, then all the macros will be displayed preceded by the individual macro number. If 'n' =-2, then all macros will be displayed and will be preceded by the letters "MD" and the individual macro number. This is useful when downloading programs from the LAC-25 to a computer in that you need not re-enter the Macro Define (MD) command and number at the beginning of each macro.
Related Commands: MD
Command: UMn -- Un-push Macro(s) --
Argument: 0 or 1
This command is used for controlling the macro subroutine call and return stack. If this command is used with no argument or an argument of "0" then one macro will be removed from the macro stack. If there is no macro to be removed then a MACRO_STACK_UNDERFLOW error will be reported. If the argument is "1" then the macro stack will be completely reset. The UM command is used in the event that a macro is paused due to a program interrupt and it is not desirable to return to that macro, or under some circumstances, a program may need to completely reset itself.
Related Commands: MC, interrupts
61
Page 57
SMAC LAC-25 Technical Reference Manual
4.8 Input / Output (I/O) Commands
The user is able to manipulate the LAC-25's I/O channels via the use of several commands. These include setting or clearing outputs, reading inputs and altering the logic type of both.
Command: BIn -- Bulk Input from I/O Port 'n' --
Argument: 0 <= n <= 7
This command reads the value at the 8-bit digital input port and copies it to the low 8-bits of the accumulator with the lower channel being the lowest bit in the accumulator. The unused bits of the accumulator will be set to 0. The state of the inputs will be determined by the Channel High (CH) and Channel Low (CL) commands and the inputs will have been debounced if the Input Debounce (ID) command is in effect.
Related Commands: BO
Command: BOn -- Bulk Output to I/O Port 'n' --
Argument: 0 <= n <= 7
This command copies the low 8-bits of the accumulator to the digital output port. The state of the outputs will be determined by the Channel High (CH) and Channel Low (CL) commands. Unused bits in the accumulator are ignored.
Related Commands: BI
Command: CFn -- Turn I/O Channel 'n' "Off" --
Argument: 0 <= n <= 63 Default: "Off"
This command will cause I/O channel 'n' to assume the "off" state. The actual output state will depend on whether the channel is set active "on" (CH command) or active "off" (CL command).
Related Commands: CH, CL, CN
Command: CHn -- Make I/O Channel 'n' Active High --
Argument: 0 <= n <= 63 Default: Active high or active "on"
This command causes I/O channel 'n' to assume an active "on" mode.
Related Commands: CL
62
Page 58
SMAC LAC-25 Technical Reference Manual
Command: CLn -- Make I/O Channel 'n' Active Low --
Argument: 0 <= n <= 63 Default: Active high or active "on"
This command causes I/O channel 'n' to assume an active "off" mode.
Related Commands: CH
Command: CNn -- Turn I/O Channel 'n' "On" --
Argument: 0 <= n <= 63 Default: "Off"
This command will cause I/O channel 'n' to assume the "on" state. The actual output state will depend on whether the channel is set active "on" or active "off".
Related Commands: CF, CH, CL
Command: IDn -- Input Debounce 'n' milliseconds --
Argument: 0 <= n <= 7 Default: 0
This command determines the length of debounce time, if any, that is applied to the digital inputs. The digital inputs are sampled once every millisecond. What this means is that an input must remain in a given state for 'n' samples before it is considered valid. If the argument 'n' is "0", then no input debouncing in performed. This debouncing applies to the following commands: BI, DF, DN, IF, IN, WF, WN.
63
Page 59
SMAC LAC-25 Technical Reference Manual
4.9 Future Expansion Interface
For future expansion, the LAC-25 provides a proprietary high speed serial data bus. Such uses might include various external devices such as thumb-wheel switches, LED or LCD displays, switch panels and additional number or types of input and output. This provides custom expansion flexibility in certain qualified OEM applications.
64
Page 60
SMAC LAC-25 Technical Reference Manual
4.10 Serial Communications and Miscellaneous Commands
These commands control operation of the serial communication's interface and cover the balance of the LAC-25 functions not fitting in the other categories.
Command: BK -- Break --
This command will cause the rest of the command line or macro to be skipped. This command is used along with the Sequence Commands for conditional command execution.
Command: BRn -- Set Baud Rate --
Argument: 300, 600, 1200, 2400, 4800, 9600 or 19,200 Default: 9600
This command allows the user to change the baud rate at which the serial communication's interface operates. Once this command has been issued with a valid argument, the communication's interface will then immediately operate at the specified baud rate. This baud rate will remain in place, even after power cycling the unit, until it is changed again. Please note
that the default baud rate is 9600.
65
Page 61
SMAC LAC-25 Technical Reference Manual
Command: CDn -- Capture Data --
Argument: 0 <= n <= 16383
This command allows for the capture and recording of data from an internal variable with the user being able to later download and plot this data for analysis. The number of samples that can be recorded depends on the amount of macro memory available at the time that the Capture Storage (CS) command is issued.
The argument determines the number of samples to record. If an argument is used that is greater than the allocated storage space, then the argument will be truncated to fit that space. Al l data sizes are extended to 32 bits before they are stored.
Before using the CD command, a few things must be taken care of. The first of these is to define an area to store the data. The Capture Storage (CS) command is used for this in that i t allocates a storage area in the macro memory to where the data can be recorded. The next thing to do is to specify the location and size of the data to be recorded. The internal 16-bit variable ÒRecAddrÓ (see Register commands) is used to specify the location (or address) of the variable to be recorded. The internal 16-bit variable ÒRecSizeÓ is used to specify the data size. If bit 0 of ÒRecSizeÓ is equal to Ò1Ó then 8 bit data samples are recorded. If bit 1 of ÒRecSizeÓ is equal to Ò1Ó then 16 bit data samples are recorded. If bits 0 and 1 of ÒRecSizeÓ are both Ò0Ó then 32 data samples are recorded. The last thing that needs to be specified is the sample rate at which the data is captured. This is set by writing the appropriate value to the 16-bit variable ÒRecRateÓ. T he sample rate will be whatever the servo sample rate is (see SS command) divided by ÒRecRateÓ.
After using the CD command, the Dump Data (DD) command can be used to display the data that was captured.
Example:
To make 2000 records of the actual position of axis 2 you would issue the following commands:
CS2000 ; Reserve space for 2000 samples. ; ; ; AL4,WW422 ; Servo rate = 1mS so Data rate = 4mS. AL638,WW424 ; Set address of axis 2 Curp. AL0,WW426 ; Set for 32-bit variable size.
The CS command should be used only once. After that, the CD and DD commands can b e used repeatedly.
Related Commands: CS, DD
RecSize Recorded Variable Size
1 8 Bits 2 16 Bits 0 32 Bits
66
Page 62
SMAC LAC-25 Technical Reference Manual
Command: CSn -- Capture Storage --
Argument: 0 <= n <= 16383
This command is used to allocate storage space for the data recorder commands. The argument determines the maximum number of samples that can be recorded. If an argument is used that is greater than the macro memory available, then an error will be reported. Because information pertaining to this command is stored in non-volatile memory, once this command is issued, the storage space will remain, even after power-cycling. To recover the macro memory used by this command, use the Reset Macros (RM) command.
Related Commands: CD, DD
Command: DDn -- Dump Data --
Argument: 0 <= n <= 16383
This command is used to dump data that has been previously recorded by the Capture Data (CD) command to the display. The argument determines the number of recorded samples to display. If an argument is used that is greater than the allocated storage space, then the argument will be truncated to fit that space.
Related Commands: CD, CS
Command: DM -- Decimal Mode --
Default: Decimal Mode
This command causes all numerical input and output to be interpreted as decimal or base
10. Numbers will be output with a leading "-" if they are less than zero.
Related Commands: HM
Command: EF -- Echo Off --
Default: Echo On
This command suppresses the echoing of characters received by the serial communication's interface. It is normally used in the half-duplex mode of operation in serial communications.
Related Commands: EN
67
Page 63
SMAC LAC-25 Technical Reference Manual
Command: EN -- Echo On --
Default: Echo On
This command causes characters received from the serial communication's interface to be echoed as they are received. It is normally used in the full-duplex mode of operation in serial communications.
Related Commands: EF
Command: GAn -- Get A/D Channel
Argument: 0 <= n <= 9
This command will cause a conversion on A/D channel 'n' and will store the result in the bottom 10 bits of the accumulator. Unused bits will be set to 0.
Related Commands: TA
Command: HF -- Hardware Handshaking Off --
Default: Hardware handshake off
This command does not function and is retained for backward compatibility reasons.
Command: HM -- Hexadecimal Mode --
Default: Decimal Mode
This command causes all numerical input and output to be interpreted as hexadecimal or base 16. Numbers will be output as 2, 4 or 8 digits with leading 0's if they are positive and leading F's if they are negative.
Related Commands: DM
Command: HN -- Hardware Handshaking On --
Default: Hardware handshake off
This command does not function and is retained for backward compatibility purposes.
68
Page 64
SMAC LAC-25 Technical Reference Manual
Command: MG[[""][:n][:N]] -- Display Message --
Argument: 0 <= n <= 511
This command allows for the display of an optional text string and / or an optional register variable with the additional option of inhibiting the carriage return / linefeed (CRLF) at the end.
The text string must be enclosed by quotes """ and may be up to 127 characters long. Additional parameters must be separated by a colon ":" .
The following are all the valid examples. Note that the "N" option inhibits a CRLF. Parameters must be given in specific order.
>MG ; Display CRLF only.
>MG"THE BLACK BEAR IS " ; Display "THE BLACK BEAR IS " followed by
; CRLF.
>MG0 ; Display contents of register 0 followed
; by CRLF.
>MGN ; This command displays nothing followed
; by nothing.
>MG"THE BLACK BEAR IS ":0 ; Display "THE BLACK BEAR IS " followed by
; the contents of register 0 followed by
; CRLF.
>MG"THE BLACK BEAR IS ":N ; Display "THE BLACK BEAR IS " followed by
; nothing.
>MG0:N ; Display the contents of register 0
; followed by nothing.
>MG"THE BLACK BEAR IS ":0:N ; Display "THE BLACK BEAR IS " followed by
; the contents of register 0 followed by
; nothing.
Command: NO -- No Operation --
This command does nothing. It can be used to cause short delays in command line executions or to fill out commands (see Sequence Commands).
Command: RT -- Reset --
This command performs a complete restart of the LAC-25, including restoration of a ll default conditions, such as acceleration and velocity, and leaves all servo axis' in the "off" state.
69
Page 65
SMAC LAC-25 Technical Reference Manual
Command: VI[[""][:n][:N]] -- Variable Input --
Argument: 0 <= n <= 255
This command allows for the display of an optional text string, an optional carriage return / linefeed (CRLF) and the entry of integer numeric operator input to a register variable.
The text string must be enclosed by quotes """ and may be up to 127 characters long. Additional parameters must be separated by a colon ":". Entered numbers will be interpreted (as decimal or hexadecimal) as determined by the current mode set by the DM or HM commands. If the value entered by the operator is in error (indeterminate), then the Bad Input bit (bit 15 of the variable SYSSTAT) is set, otherwise it is cleared. If no operator input is entered (only a carriage return is received), then no register will be altered. If no argument is given and operator input is received, then register 0 will be the default recipient of the input value.
The following are all the valid examples. Note that the "N" option causes a CRLF. Parameters must be given in specific order.
>VI ; Wait for operator input (if any) to register 0.
>VI"ENTER NUMBER: " ; Display "ENTER NUMBER: " and wait for
; operator input (if any) to register 0.
>VI5 ; Wait for operator input (if any) to
; register 5.
>VIN ; Display a CRLF and wait for operator input
; (if any) to register 0.
>VI"ENTER NUMBER: ":5 ; Display "ENTER NUMBER: " and wait for
; operator input (if any) to register 5.
>VI"ENTER NUMBER: ":N ; Display "ENTER NUMBER: " followed by a
; CRLF and wait for operator input (if any) ; to register 0.
>VI5:N ; Display a CRLF and wait for operator input
; (if any) to register 5.
>VI"ENTER NUMBER: ":5:N ; Display "ENTER NUMBER: " followed by a CRLF
; and wait for operator input (if any) to ; register 5.
Command: XFn -- Set XOFF Code --
Argument: 0 <= n <= 255 Default: 19
This command does not function and is retained for backward compatibility purposes.
70
Page 66
SMAC LAC-25 Technical Reference Manual
Command: XNn -- Set XON Code --
Argument: 0 <= n <= 255 Default: 17
This command does not function and is retained for backward compatibility purposes.
Command: ZF -- Format NVRAM --
Argument: n = 123
This command re-formats and re-initializes the LAC-25's non-volatile static ram (NVRAM). This means that any macros will be deleted and their space recovered, register contents will be set to 0 and the baud rate (among other things) will be set to their default values. Evidence of the baud rate change will not be immediate but will occur when the unit is either power cycled or the Reset (RT) command is issued. This command is intended for use by the manufacturer to place the unit in a known state after testing but is sometimes useful as a "when all else fails" means under certain circumstances. This command must include an argument "key code" of "123" in order to function. This is to reduce the possibility of accidental execution.
Command: ZZ -- Dump Memory --
Argument: 0 <= n <= $3FFFF
This command does a display dump of the memory starting at address 'n'. This command is intended for use by the manufacturer for diagnosing purposes.
71
Page 67
SMAC LAC-25 Technical Reference Manual
5. Appendix A, LAC-25 Error Code Definitions
1 - ARGUMENT ERROR.
This error indicates that a command argument was not given or was specified out of the permissible numerical range.
2 - INVALID COMMAND.
This error indicates that an invalid or unrecognized command was specified in the command line.
3 - INVALID MACRO COMMAND.
This error indicates that an invalid or unrecognized command was used in defining a macro.
4 - MACRO ARGUMENT ERROR.
This error indicates that a command argument was not given or was specified out of the permissible numerical range in defining a macro.
5 - MACRO NOT DEFINED
This error indicates that execution of an undefined macro was attempted.
6 - MACRO OUT OF RANGE.
The LAC-25 allows for a maximum of 256 macros (numbered 0 to 255). This error indicates that an attempt was made to access a macro out of this boundary.
7 - OUT OF MACRO SPACE.
The LAC-25 allows for a maximum of 256 macros with up to 256 commands per macro and approximately 15800 bytes of macro storage space. Each macro command requires 6 bytes of macro storage memory and each macro requires an overhead of 1 byte. This error indicates that so many macros/macro commands have been defined that there is no remaining memory to define more.
8 - CAN'T DEFINE MACRO IN A MACRO.
This error indicates that an attempt was made to define a macro from another macro that is currently being executed. This is not allowed on the LAC-25 as to prevent loss of program control due to possible "nesting".
9 - CAN'T DEFINE MACRO WHILE SERVO ENABLED.
This error indicates that attempt was made to define a macro while a servo axis the was enabled (i.e.: "MN"). This is not allowed on the LAC-25 as to prevent loss of program and/or servo control due to macro memory space definition contention.
10 - MACRO JUMP ERROR.
This command indicates that an attempt was made to jump ("MJ" command) to a command within a macro that does not exist.
72
Page 68
SMAC LAC-25 Technical Reference Manual
11 - OUT OF MACRO STACK SPACE.
When a macro is called by another macro (via the "MC" command or a macro interrupt), the return macro and macro command number must be saved along with other internal variables. This error indicates that the memory space set aside for this purpose has been exhausted and no more "calls" may be attempted. The LAC-25 is capable of macro calls nested 25 deep.
12 - MACRO MUST BE FIRST COMMAND.
When defining a macro, the "MD" command must be the first command in the command line. This error indicates that this requirement was not met.
13 - STRING ERROR
When using a MG or VI command, no closing quote was encountered.
14 - MACRO STRING ERROR
When using a MG or VI command in defining a macro, no closing quote was encountered.
15 - SYNTAX ERROR
Indicates the improper usage of the MG or VI commands.
16 - MACRO SYNTAX ERROR
Indicates the improper usage of the MG or VI commands while defining a macro.
17 - AXIS RANGE ERROR
The axis specified is out the possible numerical range.
18 - INTERRUPT MACRO NOT DEFINED
During the course of interrupt processing, at attempt was made to go to an undefined macro.
19 - INTERRUPT MACRO STACK ERROR
Indicates that the macro stack has run out of space during interrupt processing.
20 - MACRO STACK OVERFLOW
The macro stack has run out of space.
21 - MACRO STACK UNDERFLOW
An attempt was made to "pop" a macro off of the macro stack when there was no macro to pop.
73
Page 69
SMAC LAC-25 Technical Reference Manual
6. Appendix B, Summary of LAC-25 Commands
Parameter Commands
DB - - Set Dead Band FA -- Feed-forward, Acceleration FF - - Fail Input Off FN - - Fail Input On FR - - Derivative Sampling Frequency FV -- Feed-forward, Velocity GR -- Set Electronic Gearing Ratio IL -- Integration Limit LF -- Limit Off LM -- Limit Mode LN -- Limit On OM - - Output Mode OO -- Output Offset PH - - Phase RI - - Sampling Rate of Integral SA - - Set Acceleration SC - - Set Current Gain SD -- Set Derivative Gain SG - - Set Proportional Gain SI -- Set Integral Gain SQ - - Set Torque SS -- Set Servo Speed SV - - Set Velocity
Reporting Commands
TA -- Tell A/D Channel TB -- Tell Breakpoint TC - - Tell Channel TD - - Tell Derivative Gain TE -- Tell Last Command Error TF - - Tell Following Error TG -- Tell Position Gain TI - - Tell Integral Gain TK -- Tell (K)Constants TL -- Tell Integration Limit TM -- Tell Macros TO -- Tell Optimal Position TP -- Tell Real Position TQ -- Tell Torque TR - - Tell Register TS -- Tell Status TT - - Tell Target Position TV -- Tell Current Velocity VE - - Tell Version
Motion Commands
AB - - Abort Motion CI - - Capture Index DA -- Disable Axis DH - - Define Home DI - - Set Direction EA - - Enable Axis EG - - Enter Electronic Gearing Mode FE -- Find Edge (Home)
FI - - Find Edge (Index) GH -- Go Home GO - - Go (start motion) MA - - Move Absolute MF - - Motor Off MN -- Motor On MR -- Move Relative PM -- Position Mode QM - - Torque Mode SE - - Set Maximum Following Error ST - - Stop Motion VM -- Velocity Mode
Sequence Commands
DF - - Do if Channel "Off" DN - - Do if Channel "On" EP - - End Program IB -- If Accumulator Below IC -- If Accumulator Bit is Clear IE -- If Accumulator Equal to 'n' IF - - If Channel "Off" IG -- If Accumulator is ">" 'n' IN - - If Channel is "On" IP -- Interrupt on Absolute Position IR - - Interrupt on Relative Position IS - - If Accumulator Bit is Set IU - - If Accumulator Unequal to 'n' RP - - Repeat WA - - Wait WE -- Wait for Edge (Home or Index) WF -- Wait for Channel "Off" WI - - Wait for Index WN -- Wait for Channel "On" WP -- Wait for Absolute Position WR - - Wait for Relative Position WS -- Wait for Stop
Learned Position Storage Commands
LP - - Learn Current Position LT - - Learn Target Position MP -- Move to Position
Macro Commands
DV -- Disable Interrupt Vector EV - - Enable Interrupt Vector JP - - Jump Absolute JR - - Jump Relative LV -- Load Interrupt Vector MC -- Macro Call MD - - Macro Definition MJ - - Macro Jump MS - - Macro Sequence RC -- Return from Call RM - - Reset Macro(s) TM -- Tell Macro(s)
UM -- Unpush Macro
Serial Comm. and Misc. Commands
BK - - Break BR - - Baud Rate CD -- Capture Data CS -- Capture Storage DD -- Dump Data DM - - Decimal Mode EF - - Echo Off EN - - Echo On GA - - Get A/D Channel HF - - Hardware Handshaking Off HM -- Hexadecimal Mode HN - - Hardware Handshaking On MG -- Display Message NO - - No Operation RT - - Reset VI -- Variable Input XF - - Set XOFF Code XN - - Set XON Code ZF -- Format NVRAM ZZ - - Dump Memory
Register Commands
AA - - Accumulator Add AC -- Accumulator Complement AD -- Accumulator Divide AE - - Accumulator Exclusive-Or AL - - Accumulator Load AM -- Accumulator Multiply AN - - Accumulator And AO - - Accumulator Or AR -- Copy Accumulator to Reg. AS - - Accumulator Subtracted RA -- Copy Register to Accum. RB - - Read Byte RL - - Read Long RW -- Read Word SL - - Accumulator Shift Left SR -- Accumulator Shift Right TR - - Tell Register WB -- Write Byte WL -- Write Long WW -- Write Word
Input / Output (I/O) Commands
BI -- Bulk I/O Input BO - - Bulk I/O Output CF - - Turn Channel "Off" -­CH - - Make Channel Active "On" CL -- Make Channel Active "Off" CN - - Turn Channel "On" ID - - Input Debounce Delay
74
Page 70
SMAC LAC-25 Technical Reference Manual
7. Appendix C, LAC-25 Connector Pin Definitions
POWER
11
RS-232
J1 - Power Interface 8-Pin 5.08mm Centers Phoenix Digi-Key# ED1721-ND
1. Axis 1 Motor- output
2. Axis 1 Motor+ output
3. Axis 2 Motor- output
4. Axis 2 Motor+ output
5. Main V+ power input
6. Main power return
J2 - Axis Interface 26-Pin High density female D-Sub NorComp# HDT26P : Digi-Key# T815M-ND
1. Axis 2 Limit- input
2. Axis 1 Fault input
3. Axis 1 Limit+ input
4. +5 VDC
5. +5 VDC
6. Axis 2 Encoder phase B-
7. Axis 2 Encoder phase B+
8. Axis 1 Encoder phase B-
9. Axis 1 Encoder phase B+
10. Axis 2 Fault input
11. Axis 2 Limit+ Input
12. Axis 1 Home Input
13. Common
14. Common
15. Axis 2 Encoder phase A-
16. Axis 2 Encoder phase A+
17. Axis 1 Encoder phase A-
18. Axis 1 Encoder phase A+
19. Axis 2 Home Input
20. Axis 1 Limit- Input
21. Common
22. Common
23. Axis 2 Encoder Index-
24. Axis 2 Encoder Index+
25. Axis 1 Encoder Index-
26. Axis 1 Encoder Index+
J3 - Optional I/O Expansion Interface 6-Pin Modular Type AMP# 5-641337-3 : Digi-Key# A9093-ND
1. Receive Data- input
I/O EXP USER I/O SERVO INTERFACE POWER INTERFACE
STATUS
1
2. Transmit Data- output
3. Receive Data+ input
4. Transmit Data+ output
5. Clock+ output
6. Clock- output
J4 - RS-232 Communication Interface 6-Pin Modular Type AMP# 5-641337-3 : Digi-Key# A9093-ND
1. Handshake output
2. Handshake input
3. Receive data input
4. Transmit data output
5. Common
6. +5 VDC
J5 - User I/O Interface 26-Pin High density female D-Sub NorComp# HDT26P : Digi-Key# T815M-ND
1. Axis 2 Analog output
2. Analog input 2
3. Analog input 1
4. Opto-output 3
5. Opto-output 3 return
6. Opto-input 1
7. Opto-input 1 return
8. Opto-output 1
9. Opto-output 1 return
10. Axis 1 Analog output
11. Axis 2 Analog output return
12. Analog input 0
13. Opto-input 3
14. Opto-input 3 return
15. Opto-output 2
16. Opto-output 2 return
17. Opto-input 0
18. Opto-input 0 return
19. Axis 1 Analog output return
20. 10 VDC Analog refence output.
21. Analog reference return
22. Common
23. Opto-input 2
24. Opto-input 2 return
25. Opto-output 0
26. Opto-output 0 return
1
1
75
Page 71
SMAC LAC-25 Technical Reference Manual
8. Index
A
A/D interface ¥ 11 Accumulator ¥ 44 Appendix A
Error Code Definitions ¥ 72
Appendix B
Summary of Commands ¥ 74
Appendix C
Connector Pin Definitions ¥
75 Axis Variable Descriptions ¥ 45 Axis Variable Locations ¥ 47
C
Command
AA ¥ 48 AB ¥ 37 AC ¥ 48 AD ¥ 48 AE ¥ 49 AL ¥ 49 AM ¥ 49 AN ¥ 49 AO ¥ 49 AR ¥ 49 AS ¥ 49 BI ¥ 62 BK ¥ 65 BO ¥ 62 BR ¥ 65 CD ¥ 66 CF ¥ 62 CH ¥ 62 CI ¥ 38 CL ¥ 63 CN ¥ 63 CS ¥ 67 DA ¥ 38 DB ¥ 19 DD ¥ 67 DF ¥ 52 DH ¥ 38 DI ¥ 38 DM ¥ 67 DN ¥ 52 DV ¥ 58 EA ¥ 39 EF ¥ 67 EG ¥ 39 EN ¥ 68 EP ¥ 52 EV ¥ 58 FE ¥ 39 FF ¥ 20 FI ¥ 40 FN ¥ 20 FR ¥ 20 FV ¥ 19, 21
GA ¥ 68 GH ¥ 40 GO ¥ 40 GR ¥ 21 HF ¥ 68 HM ¥ 68 HN ¥ 68 IB ¥ 52, 53 ID ¥ 63 IE ¥ 53 IF ¥ 53 IG ¥ 53 IL ¥ 22 IN ¥ 53 IP ¥ 54 IR ¥ 54 IS ¥ 54 IU ¥ 54 JP ¥ 59 JR ¥ 59 LF ¥ 22 LM ¥ 22 LN ¥ 23 LP ¥ 57 LT ¥ 57 LV ¥ 59 MA ¥ 40 MC ¥ 60 MD ¥ 60 MF ¥ 40 MG ¥ 69 MJ ¥ 60 MN ¥ 41 MP ¥ 57 MR ¥ 41 MS ¥ 60 NO ¥ 69 OM ¥ 23 OO ¥ 24 PH ¥ 24 PM ¥ 41 QM ¥ 42 RA ¥ 50 RB ¥ 50 RC ¥ 61 RI ¥ 25 RL ¥ 50 RM ¥ 61 RP ¥ 54 RT ¥ 69 RW ¥ 50 SA ¥ 25 SC ¥ 26 SD ¥ 26 SE ¥ 42 SG ¥ 26 SI ¥ 26 SL ¥ 50 SQ ¥ 27 SR ¥ 51 SS ¥ 28 ST ¥ 42
SV ¥ 29 TA ¥ 30 TB ¥ 30 TC ¥ 30 TD ¥ 31 TE ¥ 31 TF ¥ 31 TG ¥ 31 TI ¥ 31 TK ¥ 32 TL ¥ 33 TM ¥ 33, 61 TO ¥ 33 TP ¥ 33 TQ ¥ 33 TR ¥ 33, 51 TS ¥ 34 TT ¥ 35 TV ¥ 35 UM ¥ 61 VE ¥ 36 VI ¥ 70 VM ¥ 43 WA ¥ 55 WB ¥ 51 WE ¥ 55 WF ¥ 55 WI ¥ 55 WL ¥ 51 WN ¥ 55 WP ¥ 56 WR ¥ 56 WS ¥ 56 WW ¥ 51 XF ¥ 70 XN ¥ 71 ZF ¥ 71 ZZ ¥ 71
Command summary ¥ 74
D
Dedicated digital inputs ¥ 8 Digital I/O "states" ¥ 9 Digital I/O interface ¥ 8 Downloading commands ¥ 18
E
Electronic Gearing Mode ¥ 37 Enabling and disabling
interrupts ¥ 13 Encoder interface ¥ 11 Entering commands ¥ 17 External fault input ¥ 8
F
Fault condition ¥ 8
76
Page 72
SMAC LAC-25 Technical Reference Manual
G
Gear Ratio ¥ 37 General purpose inputs ¥ 8 General purpose outputs ¥ 9
I
I/O Commands ¥ 62 I/O Expansion interface ¥ 64 I/O technical specifications ¥ 10 Indirect Argument ¥ 44 Internal variables ¥ 44 Interrupt completion ¥ 15 Interrupt latency ¥ 15 Interrupt priority ¥ 14 Interrupt Sources ¥ 13, 14 Interrupt vector table ¥ 13 Introduction ¥ 7 Invalid Command ¥ 17
L
Learned Position Storage
Commands ¥ 57
Loading Vector Table ¥ 13
M
Macro "0" ¥ 58 Macro commands ¥ 58 Macro interrupt system ¥ 13
Mathematical Operations ¥ 44 Miscellaneous commands ¥ 65 Motion commands ¥ 37
O
Output driver interface ¥ 11 Over-temperature Sensor ¥ 11
P
Parameter commands ¥ 19
R
Register commands ¥ 44 Register Space ¥ 44 Reporting commands ¥ 30
S
Sequence Commands ¥ 52 Serial communications
commands ¥ 65 Serial interface ¥ 11 Specifications ¥ 7 Status Bits
Accelerating ¥ 34
Bad Input ¥ 34
Breakpoint Reached ¥ 34
Coarse Home Input Active ¥
34
Current Direction ¥ 34 Current Mode ¥ 35 Desired Direction ¥ 34 Fail Input Flag ¥ 34 Limit- Active ¥ 35 Limit- Enabled ¥ 35 Limit Mode Abort ¥ 35 Limit Mode Stop ¥ 35 Limit- Tripped ¥ 35 Limit+ Active ¥ 35 Limit+ Enabled ¥ 35 Limit+ Tripped ¥ 35 Looking for Edge ¥ 34 Looking for index ¥ 34 Over Temperature / Fault ¥
34 Position Mode ¥ 34 Servo Enabled ¥ 34 Servo Error ¥ 34 Servo Stopping ¥ 34 Torque Mode ¥ 34 Trajectory Complete ¥ 34 Velocity Mode ¥ 34
Status LED ¥ 17 Switching Frequency ¥ 11 System Variable Descriptions ¥
46
System Variable Locations ¥ 48
T
Table of Contents ¥ 5 Trapezoidal Velocity Profile ¥ 37
77