SMA Sunny Tripower 6000TL, STP 5000TL-20, Sunny Tripower 8000TL, Sunny Tripower 9000TL, Sunny Tripower 7000TL User Manual

...
EN
PV Inverter
SUNNY TRIPOWER 5000TL / 6000TL / 7000TL / 8000TL / 9000TL
User Manual
STP5-9TL-BA-en-10 | TBEN-STP5-9TL | Version 1.0
SMA Solar Technology AG Table of Contents
Table of Contents
1 Information on this Document. . . . . . . . . . . . . . . . . . . . . . . 5
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Intended Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.1 Sunny Tripower. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.3 Type Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.4 Electronic Solar Switch (ESS) . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.5 Communication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4 LED Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5 Cleaning the Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table of Contents SMA Solar Technology AG
4 STP5-9TL-BA-en-10 User Manual
SMA Solar Technology AG 1 Information on this Document

1 Information on this Document

Validity
This document is valid for the following device types as of firmware version 2.00:
• STP 5000TL-20
• STP 6000TL-20
• STP 7000TL-20
• STP 8000TL-20
• STP 9000TL-20
Target Group
This document is intended for end users.
Symbols
Symbol Explanation
Indicates a hazardous situation which, if not avoided, will result directly in death or serious injury
Indicates a hazardous situation which, if not avoided, could result directly in death or serious injury
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury
Indicates a situation which, if not avoided, could result in property damage
Information that is important for a specific topic or goal, but is not safety-relevant
Indicates an essential requirement for achieving a specific goal
Desired result
A problem that might occur
1 Information on this Document SMA Solar Technology AG
Nomenclature
Complete designation Designation in this document
Electronic Solar Switch ESS
PV plant Plant
®
SMA Bluetooth
Wireless Technology Bluetooth
Sunny Tripower Inverter, product
SMA Webconnect function Webconnect function
Abbreviations
Abbreviation Description Explanation
AC Alternating Current
DC Direct Current
EC European Community
EMC Electromagnetic Compatibility
LED Light-Emitting Diode
PV Photovoltaics
VDE Verband der Elektrotechnik
Elektronik Informationstechnik e.V.
Association for Electrical, Electronic and Information Technologies
6 STP5-9TL-BA-en-10 User Manual
SMA Solar Technology AG 2 Safety

2Safety

2.1 Intended Use

The Sunny Tripower is a transformerless PV inverter with two MPP trackers, that converts the direct current of the PV array into grid-compliant three-phase current and feeds this into the electricity grid.
Figure1: Design of a PV plant with Sunny Tripower
The Sunny Tripower is suitable for indoor and outdoor use. Alternative uses of the Sunny Tripower not expressly recommended by SMA Solar Technology AG
are not permitted. For safety reasons, it is not permitted to modify the product or install components that are not explicitly
recommended or distributed by SMA Solar Technology AG for this product. The enclosed documentation is an integral part of this product.
• Read and observe the documentation.
• Keep the documentation in a convenient place for future reference.
2 Safety SMA Solar Technology AG

2.2 Safety Precautions

Electric Shock
High voltages that can cause fatal electric shocks are present in the live components of the inverter.
• Do not open the inverter.
• All work on the inverter (e.g. repairs, modification) must be carried out by skilled persons only.
Burn Hazards
Some parts of the enclosure can become hot during operation.
• During operation, only touch the protective cover and the display.
Yield Loss
Poor heat dissipation can lead to yield loss.
• Do not place any objects on the enclosure.
Inverter Damage
Overvoltages can destroy the inverter.
• If the display message DC overvoltage - Disconnect generator is shown, inform your installer IMMEDIATELY.
8 STP5-9TL-BA-en-10 User Manual
Loading...