SMA 485 User Manual

Installation Manual
485 Data Module Type B
485BRD-10-IA-en-12 | Version 1.2 ENGLISH
Legal Provisions SMA Solar Technology AG
Legal Provisions
The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission.
SMA Warranty
You can download the current warranty conditions from the Internet at www.SMA-Solar.com.
Trademarks
All trademarks are recognized, even if not explicitly identified as such. A lack of identification does not mean that a product or symbol is not trademarked.
The BLUETOOTH and any use of these marks by SMA Solar Technology AG is under license.
Modbus® is a registered trademark of Schneider Electric and is licensed by the Modbus Organization, Inc.
QR Code is a registered trademark of DENSO WAVE INCORPORATED.
®
Phillips
and Pozidriv® are registered trademarks of Phillips Screw Company.
®
Torx
is a registered trademark of Acument Global Technologies, Inc.
SMA Solar Technology AG
Sonnenallee 1 34266 Niestetal Germany
Tel. +49 561 9522-0 Fax +49 561 9522-100 www.SMA.de E-mail: info@SMA.de
© 2004 to 2014 SMA Solar Technology AG. All rights reserved.
®
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc.
2 485BRD-10-IA-en-12 Installation Manual
SMA Solar Technology AG Table of Contents
Table of Contents
1 Information on this Document. . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Validity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Target Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Additional Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.4 Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.5 Typography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.6 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Appropriate Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Scope of Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.1 485 Data Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2 Type Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5 Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.1 Safety during Electrical Connection. . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2 Mounting Position and Cable Routing. . . . . . . . . . . . . . . . . . . . . . . . 12
5.3 Installing the 485 Data Module in the Inverter . . . . . . . . . . . . . . . . . 13
5.4 Preparing the Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.5 Preparing the Cable Gland on the Inverter . . . . . . . . . . . . . . . . . . . . 15
5.6 Connecting the Cables to the 485 Data Module . . . . . . . . . . . . . . . 17
6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7 Decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.1 Disassembling the 485 Data Module . . . . . . . . . . . . . . . . . . . . . . . . 20
7.2 Packaging the 485 Data Module for Shipping. . . . . . . . . . . . . . . . . 20
7.3 Disposing of the 485 Data Module . . . . . . . . . . . . . . . . . . . . . . . . . 20
8 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
9 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Installation Manual 485BRD-10-IA-en-12 3
Table of Contents SMA Solar Technology AG
4 485BRD-10-IA-en-12 Installation Manual
SMA Solar Technology AG 1 Information on this Document

1 Information on this Document

1.1 Validity

This document is valid for the device type "485BRD-10" (485 Data Module Type B).

1.2 Target Group

The tasks described in this document must be performed by qualified persons only. Qualified persons must have the following skills:
• Training in how to deal with the dangers and risks associated with installing and using electrical devices and plants
• Training in the installation and commissioning of electrical devices and plants
• Knowledge of all applicable standards and directives
• Knowledge of how an inverter works and is operated
• Knowledge of and compliance with this document and all the safety precautions

1.3 Additional Information

Links to additional information can be found at www.SMA-Solar.com:
Document title Document type
RS485 Cabling Plan Technical description

1.4 Symbols

Symbol Explanation
Indicates a hazardous situation which, if not avoided, will result in death or serious injury
Indicates a hazardous situation which, if not avoided, could result in death or serious injury
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury
Indicates a situation which, if not avoided, could result in property damage
Information that is important for a specific topic or goal, but is not
safety-relevant ☐ Indicates an essential requirement for achieving a specific goal ☑ Desired result ✖ A problem that might occur
Installation Manual 485BRD-10-IA-en-12 5
1 Information on this Document SMA Solar Technology AG

1.5 Typography

Typography Explanation Example bold • Display texts
• Elements of a user interface
•Terminals
• Elements to be selected
• Elements to be entered
> • Connects several elements to
be selected
[Button/Key] • B utt on o r ke y to be s ele cte d or
pressed
• The value can be read from the Energy field.
• Select Settings.
•Enter the value 10 in the Minutes field.
• Select Settings > Date.
• Select [Next].

1.6 Nomenclature

In this document, the "485 Data Module Type B" is referred to as "485 data module".
6 485BRD-10-IA-en-12 Installation Manual
SMA Solar Technology AG 2 Safety

2 Safety

2.1 Appropriate Usage

The 485 data module enables you to setup cable-connected RS485 communication. The 485 data module can be retrofitted, or installed in the inverter at the factory if specified in the
order. The inverter still complies with the standard after the product has been installed. The 485 data module is suitable for installation in the following SMA inverters:
Sunny Tripower Windy Tripower
STP 5000TL-20 STP 6000TL-20 STP 7000TL-20 STP 8000TL-20 STP 9000TL-20 STP 10000TL-20 STP 12000TL-20
Us e th is p rod uct onl y in acc ord anc e wi th t he i nfo rma tio n pr ovi ded in the enclosed documentation and with the locally applicable standards and directives. Any other use may result in personal injury or property damage.
For safety reasons, it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product.
The enclosed documentation is an integral part of this product.
• Read and observe the documentation.
• Keep the documentation in a convenient place for future reference.
WTP 5000TL-20 WTP 6000TL-20 WTP 7000TL-20 WTP 8000TL-20 WTP 9000TL-20
Installation Manual 485BRD-10-IA-en-12 7
2 Safety SMA Solar Technology AG

2.2 Safety Precautions

This section contains safety precautions that must be observed at all times when working on or with the product.
To prevent personal injury or property damage and to ensure long-term operation of the product, read this section carefully and follow the safety precautions at all times.
Electric shock due to live voltage
High voltages that can cause fatal electric shocks are present in the live components of the inverter.
• Prior to performing any work on the inverter, always disconnect the inverter from any voltage sources as described in the corresponding installation manual (see inverter installation manual).
Risk of burns due to hot enclosure parts
Some parts of the inverter enclosure can get hot during operation.
• During operation, touch the inverter on the enclosure lid and the protective cover only.
Damage to the 485 data module or the inverter due to electrostatic discharge
Touching electronic components on the 485 data module or in the inverter can cause damage to or destroy the 485 data module and the inverter through electrostatic discharge.
• Earth yourself before touching any components.
• Avoid any contact with components and plug contacts.
8 485BRD-10-IA-en-12 Installation Manual