![](/html/65/6529/6529aa5b356a794ad54f3e23ac03b6bf44aef308fd337679b1b302d16dc2f811/bg1.png)
SL74HC193
Presettable 4-Bit Binary UP/DOWN Counter
High-Performance Silicon-Gate CMOS
The SL74HC193 is identical in pinout to the LS/ALS193. The device
inputs are compatible with standard CMOS outputs; with pullup
resistors, they are compatible with LS/ALSTTL outputs.
The counter has two separate clock inputs, a Count Up Clock and
Count Down Clock inputs. The direction of counting is determined by
which input is clocked. The outputs change state synchronous with
the LOW-to-HIGH transitions on the clock inputs. This counter may be
preset by entering the desired data on the P0, P1, P2, P3 input. When
the Parallel Load input is taken low the data is loaded independently of
either clock input. This feature allows the counters to be used as
devide-by-n by modifying the count lenght with the preset inputs. In
addition the counter can also be cleared. This is accomplished by
inputting a high on the Master Reset input. All 4 internal stages are set
to low independently of either clock input.Both a Terminal Count
Down (TCD) and Terminal Count Up (TCU) Outputs are provided to
enable cascading of both up and down counting functions. The TCD
output produces a negative going pulse when the counter underflows
and TCU outputs a pulse when the counter overflows. The counter can
be cascaded by connecting the TCU and TCD outputs of one device to
the Count Up Clock and Count Down Clock inputs, respectively, of the
next device.
• Outputs Directly Interface to CMOS, NMOS, and TTL
• Operating Voltage Range: 2.0 to 6.0 V
• Low Input Current: 1.0 µA
• High Noise Immunity Characteristic of CMOS Devices
ORDERING INFORMATION
SL74HC193N Plastic
SL74HC193D SOIC
TA = -55° to 125° C for all packages
PIN ASSIGNMENT
LOGIC DIAGRAM
PIN 16 =VCC
PIN 8 = GND
SLS
System Logic
![](/html/65/6529/6529aa5b356a794ad54f3e23ac03b6bf44aef308fd337679b1b302d16dc2f811/bg2.png)
SL74HC193
MAXIMUM RATINGS*
Symbol Parameter Value Unit
VCC DC Supply Voltage (Referenced to GND) -0.5 to +7.0 V
VIN DC Input Voltage (Referenced to GND) -1.5 to VCC +1.5 V
V
DC Output Voltage (Referenced to GND) -0.5 to VCC +0.5 V
OUT
IIN DC Input Current, per Pin ±20 mA
I
DC Output Current, per Pin ±25 mA
OUT
ICC DC Supply Current, VCC and GND Pins ±50 mA
PD Power Dissipation in Still Air, Plastic DIP+
SOIC Package+
750
500
Tstg Storage Temperature -65 to +150 °C
TL Lead Temperature, 1 mm from Case for 10 Seconds
260 °C
(Plastic DIP or SOIC Package)
*
Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
+Derating - Plastic DIP: - 10 mW/°C from 65° to 125°C
SOIC Package: : - 7 mW/°C from 65° to 125°C
RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Min Max Unit
VCC DC Supply Voltage (Referenced to GND) 2.0 6.0 V
VIN, V
DC Input Voltage, Output Voltage (Referenced to GND) 0 VCC V
OUT
TA Operating Temperature, All Package Types -55 +125 °C
tr, tf Input Rise and Fall Time (Figure 1) VCC =2.0 V
VCC =4.5 V
V
=6.0 V
CC
0
0
0
1000
500
400
mW
ns
This device contains protection circuitry to guard against damage due to high static voltages or electric
fields. However, precautions must be taken to avoid applications of any voltage higher than maximum rated
voltages to this high-impedance circuit. For proper operation, VIN and V
GND≤(VIN or V
OUT
)≤VCC.
should be constrained to the range
OUT
Unused inputs must always be tied to an appropriate logic voltage level (e.g., either GND or VCC).
Unused outputs must be left open.
System Logic
SLS
![](/html/65/6529/6529aa5b356a794ad54f3e23ac03b6bf44aef308fd337679b1b302d16dc2f811/bg3.png)
SL74HC193
The IN74HC193 is an UP/DOWN MODULO-16
DC ELECTRICAL CHARACTERISTICS(Voltages Referenced to GND)
VCC Guaranteed Limit
Symbol Parameter Test Conditions V 25 °C
to
-55°C
VIH Minimum High-Level
Input Voltage
VIL Maximum Low -Level
Input Voltage
VOH Minimum High-Level
Output Voltage
VIN=VIH or VIL
VOL Maximum Low -Level
Output Voltage
VIN=VIH or VIL
IIN Maximum Input
V
=0.1 V or VCC-0.1 V
OUT
I
≤ 20 µA
OUT
V
=0.1 V or VCC-0.1 V
OUT
I
≤ 20 µA
OUT
VIN=VIH or VIL
I
≤ 20 µA
OUT
I
≤ 4.0 mA
OUT
I
≤ 5.2 mA
OUT
VIN=VIH or VIL
I
≤ 20 µA
OUT
I
≤ 4.0 mA
OUT
I
≤ 5.2 mA
OUT
2.0
4.5
6.0
2.0
4.5
6.0
2.0
4.5
6.0
4.5
6.0
2.0
4.5
6.0
4.5
6.0
1.5
3.15
4.2
0.3
0.9
1.2
1.9
4.4
5.9
3.98
5.48
0.1
0.1
0.1
0.26
0.26
VIN=VCC or GND 6.0 ±0.1 ±1.0 ±1.0 µA
Leakage Cur rent
≤85
°C
1.5
3.15
4.2
0.3
0.9
1.2
1.9
4.4
5.9
3.84
5.34
0.1
0.1
0.1
0.33
0.33
≤125
°C
1.5
3.15
4.2
0.3
0.9
1.2
1.9
4.4
5.9
3.7
5.2
0.1
0.1
0.1
0.4
0.4
Unit
V
V
V
V
ICC Maximum Quiescent
Supply Current
(per Package)
FUNCTION TABLE
Inputs Mode
MR PL CPU CPD
H X X X Reset(Asyn.)
L L X X Preset(Asyn.)
L H H No Count
L H H Count Up
L H H Count Down
L H H No Count
X = don’t care
VIN=VCC or GND
I
=0µA
OUT
6.0 8.0 80 160 µA
Binary Counter.
Logic equations
For Terminal Count:
TCU = Q0 • Q1 • Q2 • Q3 • CPU
TCD = Q0 • Q1 • Q2 • Q3 • CPD
SLS