SLS SL4093BD, SL4093BN Datasheet

SL4093B
Semiconductor
Quad 2-Input NAND Schmitt Triggers
High-Voltage Silicon-Gate CMOS
The SL4093B consists of four Schmitt-trigger circuits. Each circuit functions as a two-input NAND gate with Schmitt-trigger action on both inputs. The gate switches at different points for positive- and negative- going signals. The difference between the positive voltage (VP) and the negative voltage (VN) is defined as hysteresis voltage (VH) (see Fig.1).
Operating Voltage Range: 3.0 to 18 V
Maximum input current of 1 µA at 18 V over full package-
temperature range; 100 nA at 18 V and 25°C
Noise margin (over full package temperature range):
1.0 V min @ 5.0 V supply
2.0 V min @ 10.0 V supply
2.5 V min @ 15.0 V supply
LOGIC DIAGRAM
ORDERING INFORMATION
SL4093BN Plastic
SL4093BD SOIC
TA = -55° to 125° C for all packages
PIN ASSIGNMENT
PIN 14 =VCC
PIN 7 = GND
FUNCTION TABLE
Inputs Output
A B Y
L L H
L H H H L H H H L
System Logic
SLS
SL4093B
Semiconductor
MAXIMUM RATINGS*
Symbol Parameter Value Unit
VCC DC Supply Voltage (Referenced to GND) -0.5 to +20 V VIN DC Input Voltage (Referenced to GND) -0.5 to VCC +0.5 V
V
DC Output Voltage (Referenced to GND) -0.5 to VCC +0.5 V
OUT
IIN DC Input Current, per Pin ±10 mA PD Power Dissipation in Still Air, Plastic DIP+
SOIC Package+
PD Power Dissipation per Output Transistor 100 mW
Tstg Storage Temperature -65 to +150 °C
TL Lead Temperature, 1 mm from Case for 10 Seconds
(Plastic DIP or SOIC Package)
Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions. +Derating - Plastic DIP: - 10 mW/°C from 65° to 125°C
SOIC Package: : - 7 mW/°C from 65° to 125°C
750 500
260 °C
RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Min Max Unit
VCC DC Supply Voltage (Referenced to GND) 3.0 18 V
VIN, V
DC Input Voltage, Output Voltage (Referenced to GND) 0 VCC V
OUT
TA Operating Temperature, All Package Types -55 +125 °C
mW
This device contains protection circuitry to guard against damage due to high static voltages or electric fields. However, precautions must be taken to avoid applications of any voltage higher than maximum rated voltages to this high-impedance circuit. For proper operation, VIN and V GND(VIN or V
Unused inputs must always be tied to an appropriate logic voltage level (e.g., either GND or VCC). Unused outputs must be left open.
System Logic
SLS
OUT
)VCC.
should be constrained to the ra nge
OUT
Loading...
+ 3 hidden pages