MAXIMUM RATINGS* (TA = 25°C)
Symbol Parameter Value Unit
VTP Calling Voltage (f = 50 Hz) Continuous 120 Vrms
VTP Calling Voltage (f = 50 Hz) 5 Sec ON/10 Sec OFF 200 Vrms
ICC Supply Current 22 mA
Tstg Storage and Junction Temperature -65 to +150 °C
*
Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Min Max Unit
VCC Supply Voltage 26 V
TA Operating Temperatur e -20 +70 °C
This device contains protection circuitry to guard against damage due to high static voltages or electric
fields. However, precautions must be taken to avoid applications of any voltage higher than maximum rated
voltages to this high-impedance circuit. For proper operation, VIN and V
OUT
should be constrained to the range
GND≤(VIN or V
OUT
)≤VCC.
Unused inputs must always be tied to an appropriate logic voltage level (e.g., either GND or VCC).
Unused outputs must be left open.
ELECTRICAL CHARACTERISTICS(T
A
= 25°C)
Symbol
Parameter
Test Conditions
Guaranteed Limits
Unit
Min Typ Max
ICC Current Consumption without
Load
VS=8.8 to 26 V 1.8 mA
VON Activiation Voltage 12.2 13 V
V
ONR
Activiation Voltage Range RA = 1 KΩ 8 10 V
V
SUS
Sustaining Voltage 8 8.8 V
RD Differential Resistance in Off
Condition
6.4 KΩ
V
OUT
Output Voltage Swing VCC-3 V
I
OUT
Short Circuit Current VS = 26 V 35 mA