PRIOR TO INSTALLATION
Prior to installing the Sloan OPTIMA XLerator®Electronic Hand Dryer,
determine the location where the dryer will be installed. Read the
following section entitled “Installation Precautions” and then refer to
Table 1 for recommended mounting heights.
Installation Precautions
• Mounting surface should be smooth and flat.
• Mount dryer at least 24 inches (610 mm) away from basins.
• Mount dryer at least 20 inches (508 mm) away from corners.
• Mount multiple hand dryers a minimum of 20 inches (508 mm)
apart, center to center.
• Avoid installing hand dryers in narrow hallways and behind swinging
doors.
Important:
•
INSTALL ALL ELECTRICAL WIRING IN ACCORDANCE WITH
NATIONAL/LOCAL CODES AND REGULATIONS.
Table 1 — Recommended Mounting Heights
Users Height
Men 45 Inches (1143 mm)
Women 43 Inches (1092 mm)
Teenagers 41 Inches (1041 mm)
Small Children 35 Inches (889 mm)
Handicapped 37 Inches (940 mm)
Important:
counter and dryer
Refer to Table 2 for recommended fasteners.
When Mounting over a countertop, distance between
MUST BE 15” (381 mm) MINIMUM.
Code No. 0816786
Rev. 1 (06/10)
INSTALLATION INSTRUCTIONS
FOR XLERATOR®HAND DRYER
Table 2 — Recommended Fasteners
Wall Type Recommended Fastener
Masonry Wall 1/2” expansion sleeve with 1/4” lag bolt
Hollow Wall 1/4” wing type through bolt
Wooden Wall 1/4” lag screw with washer
INSTALLATION INSTRUCTIONS
Step 1 — Remove Cover
Using wrench provided, remove two tamper-proof fasteners from sides
of dryer cover. Remove cover from dryer.
Step 2 — Attach Wall Plate to Wall
Attach wall plate to wall using the recommended fasteners shown in
Table 2. Install a fastener at each corner of the wall plate. In locations
where vandalism is a concern, install two additional mounting fasteners
at the locations shown in the rough-in on page 2. Remove control
assembly to access the right side mounting hole.
Step 3 — Connect Electrical Wiring
Connect a 110/120V dryer to a 15 Amp. branch circuit using at least
#12 GA copper wire. (Do not exceed a 20 Amp. branch circuit).
Connect a 220/240V dryer to no more than a 15 Amp. branch circuit
using at least a #14 GA copper wire. Attach lines to terminals as
indicated by the schematic inside dryer cover. Be sure that an
equipment ground wire is securely fastened to green ground screw on
base plate. For runs over 50 feet or for multiple installations, increase
the size of the wire used. Dryers located in shower rooms or other wet
locations should be installed with circuits protected by ground fault
interrupter(s) or as local codes require.
Step 4 — Replace Cover
For multiple installations, before replacing cover, check the Serial
Number marked inside the dryer to be sure it matches the Serial
Number marked on the label at the bottom of cover.
COVERS.
Leave the special TAMPER PROOF WRENCH with the owner.
NOTE:
Install Cover using the two tamper-proof fasteners.
If the dryer will not turn on, stays on or stops working, it may be mounted
too close to a counter or object. Turn off power to dryer for 10 seconds
and then reapply power. If dryer starts, then turn off again, relocate the
object or remount dryer. If this is not possible, adjust the range of the
sensor by turning the potentiometer on the control board clockwise to
decrease sensor range. Please contact the Sloan Installation Engineering
Department at
trained technicians will be happy to assist you.
1-888-SLOAN-14 (1-888-756-2614)
DO NOT SWITCH
and one of our
(Continued on Page 2)
LIMITED WARRANTY
Sloan Valve Company warrants its XLerator®Hand Dryer to be made of first class materials, free from defects of material or workmanship under normal use and to
perform the service for which it is intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of five years (1 year for
special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective
if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor,
transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan
Valve Company for purpose of resale.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR
ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

ROUGH-IN
NOTE:
pon completing installation and checking for proper operation, it is
U
highly recommended that a bead of silicone sealant be placed around
the outside of the cover at the wall to protect dryer from internal
corrosion caused by wash water and cleaning solutions.
If further assistance is required, contact your nearest Sloan
Representative office or the Sloan Installation Engineering Department
1-888-SLOAN-14 (1-888-756-2614).
at:
OPERATION
• When the Infrared Sensor detects hands beneath
the exhaust port, it activates the XLerator®Hand
Dryer. Water droplets are first blown from hands
with a strong controlled air blast. Residual
moisture is then evaporated with a warm stream
of air up to 135° F/57° C.
WIRING DIAGRAM — 110/120 and 220/240 VAC
• After hands are withdrawn from the Sensor’s
detection zone, or after a maximum of thirty-five
(35) seconds of continuous operation, the Hand
Dryer automatically stops. It is then ready for the
next user.
CLEANING INSTRUCTIONS
Important:
DISCONNECT ELECTRICAL SUPPLY TO DRYER PRIOR TO SERVICING.
Outside
Gently wash cover (including air Inlet holes) using a soft cloth or
sponge and a mild soap or detergent with lukewarm water to
loosen dirt and grime.
Inside
CLEANING SHOULD BE PERFORMED BY QUALIFIED SERVICE
PERSONNEL
With normal use, dryer will require cleaning once a year.
requires more frequent cleaning.
Lint on the air inlet or other internal
parts of dryer will reduce efficiency and shorten the life of the working
parts. To clean, remove cover by unscrewing the tamper-proof
fasteners from cover with the special wrench provided with each dryer.
Use a small, soft brush to gently clean all parts.
Heavier usage