Sloan Royal Exposed Flushometer User Manual

Code No. 0816195
Rev. 6 (02/15)
INSTALLATION INSTRUCTIONS FOR EXPOSED ROYAL® FLUSHOMETERS
Closet Flushometer
for 1½” Top Spud
MODELS 110/111,
113, 115 & 116
Service Sink Flushometer
for 1½” Top Spud
MODEL 117
LIMITED WARRANTY
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY
RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
Urinal Flushometer
for 1¼” Top Spud
MODEL 180
Urinal Flushometer
for ¾” Top Spud
MODEL 186
Closet Flushometer
for 1½” Back Spud
MODELS 120, 121 & 122
PRIOR TO INSTALLATION
Before you install the flushometer, be sure the items listed below are installed. Also, refer to the rough-in diagram below.
• Closet fixture • Drain line • Water supply line
IMPORTANT:
• ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.
• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
• FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
Sloan’s flushometers are designed to operate with 15 to 80 psi (103 to 552 kPa) of water pressure. THE MINIMUM PRESSURE
REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for
minimum pressure requirements. Most High Efficiency water closets require a minimum flowing pressure of 25 psi (172 kPa). Many building codes and the ASME A112.19.2 fixture standard list Maximum static water pressure as 80 PSI (552 kPa).
ROUGH-INS
MODELS 110/111,
113, 115, & 116
MODELS 120, 121, & 122
MODELS 180/186
!!! IMPORTANT !!!
WHEN MOUNTED ON AN ADA ACCESSIBLE BOWL, THE ROUGH-IN TO
THE SUPPLY INLET SHOULD BE NO HIGHER THAN 37½” OR THE
HANDLE WILL EXCEED MAXIMUM HEIGHT ALLOWANCES UNDER ADA
GUIDELINES.
MODEL 117
MODEL 186
TOOLS REQUIRED FOR INSTALLATION
• Straight blade screwdriver
• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench
!!! IMPORTANT !!!
PROTECT THE CHROME OR SPECIAL FINISH OF SLOAN
FLUSHOMETERS — DO NOT USE TOOTHED TOOLS TO
INSTALL OR SERVICE THESE VALVES. USE A SLOAN A-50
SUPER-WRENCH™, SLOAN A-109 PLIER WRENCH OR SMOOTH
JAWED SPUD WRENCH TO SECURE ALL COUPLINGS. SEE
“CARE AND CLEANING” SECTION.
!!! IMPORTANT !!!
NEVER OPEN CONTROL STOP TO WHERE THE FLOW FROM
THE VALVE EXCEEDS THE FLOW CAPABILITY OF THE
FIXTURE. IN THE EVENT OF A VALVE FAILURE, THE FIXTURE
MUST BE ABLE TO ACCOMMODATE A CONTINUOUS
FLOW FROM THE VALVE.
WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT
USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE
THIS PRODUCT CONTAINS MECHANICAL AND/OR ELECTRICAL COMPONENTS THAT ARE SUBJECT TO NORMAL WEAR. THESE
COMPONENTS SHOULD BE CHECKED ON A REGULAR BASIS
AND REPLACED AS NEEDED TO MAINTAIN THE VALVE’S
Please take the time to read this manual to ensure proper
product installation and longevity.
When further assistance is required, please contact your local
Sloan Representative or Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614)
!!! IMPORTANT !!!
COMPONENT OR COUPLING!
!!! IMPORTANT !!!
PERFORMANCE.
1 - INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD)
FINISHED WALL
Measure from finished wall to C/L of fixture spud. Cut pipe
A
1¼” (32 mm) shorter than this measurement. Chamfer O.D. and I.D. of water supply pipe.
Slide threaded adapter fully onto pipe.
B
WATER SUPPLY PIPE
1-1/4”
(32 mm)
SWEAT
Sweat solder the Adapter to pipe.
C
SOLDER ADAPTER
C/L OF
FIXTURE
SPUD
2 - INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO SUPPLY PIPE
Measure from finished wall
A
to first thread of Adapter or threaded supply pipe (dimension “X”). Cut Cover Tube to this length.
Slide Cover Tube over pipe.
B
Slide Wall Flange over Cover Tube until against wall.
Thread Control Stop onto
C
pipe. Tighten with a wrench.
WATER
SUPPLY PIPE
SET SCREW
SWEAT SOLDER ADAPTER
COVER TUBE
WALL FLANGE
SET SCREW
SUPPLY FLANGE
Tighten Set Screw with a 1/16”
D
hex wrench. DO NOT install Vandal Resistant Stop Cap at this time.
IRON PIPE NIPPLE OR COPPER PIPE WITH SWEAT SOLDER ADAPTER
COVER TUBE
3 - INSTALL VACUUM BREAKER FLUSH CONNECTION
Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and
A
Spud Flange over Vacuum Breaker Tube.
Insert Tube into Fixture Spud.
B
Hand tighten Spud Coupling onto Fixture Spud.
C
MODELS 110/111, 113, 115, 116, 117
VACUUM BREAKER
TUBE
ELBOW FLUSH
CONNECTION
SPUD COUPLING
MODELS 120, 121, 122
SPUD COUPLING
MODEL 180 MODEL 186
SPUD FLANGE
SPUD COUPLING
VACUUM
BREAKER
TUBE
BAK-CHEK CONTROL STOP
®
NYLON SLIP
GASKET
RUBBER GASKET
SPUD FLANGE
NYLON SLIP GASKET
RUBBER GASKET
2
NYLON SLIP
GASKET
RUBBER GASKET
SPUD FLANGE