Sloan REGAL 110 XL, REGAL 111 XL, REGAL 116 XL, REGAL 120 XL, REGAL 122 XL Installation Instructions Manual

...
Code No. 0816312
Rev. 1 (05/10)
I
INSTALLATION INSTRUCTIONS FOR EXPOSED REGAL®XL
LIMITED WARRANTY
Sloan Valve Company warrants its Regal XL Flushometers to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
Before you install the Regal XL Flushometer, be sure the items listed below are installed. Also, refer to the rough-in diagrams on the next page.
• Closet or urinal fixture
• Drain line
• Water supply line
Important:
I
NSTALL ALL PLUMBING IN ACCORDANCE WITH APPLICABLE CODES
AND REGULATIONS.
WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
The Sloan Regal XL Flushometer is designed to operate with 10 to 100 psi (69 to 689 kPa) of water pressure.
THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED.
Consult fixture manufacturer for minimum pressure requirements. Most Low Consumption water closets (1.6 gpf/6.0 Lpf) require a minimum flowing pressure of 25 psi (172 kPa).
Closet Flushometer 1½” (38 mm) Top Spud
MODELS 110/111, 113, 115 & 116
Closet Flushometer 1½” (38 mm) Back Spud
MODEL 120 & 122
Service Sink Flushometer 1½” (38 mm) Top Spud
MODEL 117
Urinal Flushometer 1¼” (32 mm) Top Spud
MODEL 180
Urinal Flushometer ¾” (19 mm) Top Spud
MODEL 186
Squat Toilet Flushometer 1½” (38 mm) Back Spud
MODEL 137
PRIOR TO INSTALLATION
TOOLS REQUIRED FOR INSTALLATION
• Straight blade screwdriver
• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench
2
M
MODELS 110/111
MODELS 113, 115 & 116
MODEL 117 MODELS 120/122
MODEL 180 MODEL 186
NOTE: Model 180 requires 1” I.P.S. (DN 25 mm) Supply
IMPORTANT NOTES:
• When mounted on an ADA accessible bowl, the rough-in to the supply inlet should be no higher than 37½” or the handle will exceed maximum height allowances under ADA guidelines.
• New ADAAG Guidelines allow for Split or Offset Grab Bars, check with local authorities or reference section 604.5.2 of ADAAG.
† 1” Control Stop is available with Whitworth Thread
NOTE: Water Closet Valves with “-2.4” Model Designation deliver 2.4 gpf (9.0 Lpf)
VALVE ROUGH-INS