DIMENSIONS – GAS BOILERS
®
SENTRY
|
C |
Vent Damper* |
|
|
|
Dimensions |
|
|
MODEL S-34 |
|
Integral |
11/2" Supply |
|
|
|
Draft |
|
|
|
Diverter |
|
193/4" |
|
3/4" to air eliminating system (by others)
Pressure/Temp. |
|
|
Gauge |
|
|
Blocked Vent |
287/16" |
|
Safety Switch |
||
3/4"Drain |
|
|
Rollout Safety |
|
|
Switch (behind |
A |
|
front panel) |
||
61/2" |
||
B |
LEFT END VIEW |
FRONT VIEW |
High Limit. |
|
|
Control |
|
|
Ignition |
|
|
Control |
|
|
Circulator: |
|
|
1/4" Circ. Flange |
|
Sediment Trap |
11/2" Return Tapping |
|
|
|
|
(required) |
Combination |
|
|
Gas Valve |
Ground |
(Dotted piping |
(gas tapping 1/2") |
||
|
Joint Union |
by others.) |
RIGHT END VIEW
C |
Vent Damper* |
|
Dimensions MODELS S-60 to S-150
11/2" Supply
193/4"
3/4" to air eliminating |
Blocked Vent |
system (by others) |
Safety Switch |
|
|
High Limit |
|
|
|
Supply Piping |
|
Control |
|
|
|
|
|
|
|
||
(by others) |
|
Ignition |
|
|
|
|
|
Control |
|
|
|
Pressure/Temp. |
|
327/16" |
|
|
|
Gauge |
|
Circulator: |
|
|
|
3 |
|
1/4" Circ. Flange |
|
|
|
|
11/2" Return Tapping |
|
|
||
/4" Drain |
|
|
|
Sediment Trap |
|
|
|
|
|
(required) |
|
Rollout Safety |
|
Combination |
|
|
|
Switch (behind |
|
|
|
||
A |
Gas Valve |
Ground |
(Dotted piping |
||
front panel) |
|||||
(gas tapping 1/2") |
Joint Union |
by others.) |
|||
|
|||||
|
B |
|
|
|
LEFT END VIEW |
FRONT VIEW |
RIGHT END VIEW |
C |
|
Vent Damper* |
|
Vent Damper* |
C |
|
|
|
Dimensions |
3/4" to air eliminating |
|
system (by others) |
|
|
MODELS SX-150 |
Blocked Vent |
High Limit |
Safety Switch |
||
to SX-210 |
|
Control |
|
|
11/2" |
Supply Piping |
|
|
|
|
D |
Supply |
|
|
Ignition |
|
||
|
|
|
|
|||
|
(by others) |
|
|
Control |
|
|
|
|
|
|
|
|
|
|
Pressure/Temp. |
|
287/16" |
Circulator: |
|
|
|
Gauge |
|
1/4" Circ. Flange |
|
Sediment Trap |
|
|
|
|
|
11/2" Return Tapping |
|
(required) |
|
3/4" Drain |
|
|
|
|
|
|
|
|
|
|
|
|
|
Rollout Safety |
|
|
Combination |
|
|
|
|
|
Gas Valve |
Ground |
|
|
3 |
Switch (behind |
A |
|
(Dotted piping |
||
|
(gas tapping 1/2") |
|||||
19 /4" |
front panel) |
|
Joint Union |
by others.) |
||
|
|
|||||
|
|
|
B |
|
|
|
LEFT END VIEW |
FRONT VIEW |
RIGHT END VIEW |
*Vent damper may be installed horizontally on all models with use of a common vent elbow.
|
|
|
|
|
|
|
DIMENSIONS-Inches |
|
||
|
|
|
|
|
|
|
|
C-VENT DIAMETER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MODEL |
A |
B |
INTEGRAL |
EXTERNAL |
D |
|
|
|
|
|
DRAFT |
DRAFT |
||||
|
|
|
|
|
NUMBER |
|||||
|
|
|
|
|
|
|
DIVERTER |
HOOD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S-34 |
81⁄8 |
145⁄8 |
4 |
_ |
_ |
|
|
|
|
|
S-60 |
111⁄8 |
175⁄8 |
4 |
_ |
_ |
|
|
|
|
|
S-90 |
141⁄8 |
205⁄8 |
5 |
_ |
_ |
|
|
|
|
|
S-120 |
171⁄8 |
235⁄8 |
6 |
_ |
_ |
|
|
|
|
|
S-150 |
201⁄8 |
265⁄8 |
7 |
_ |
_ |
|
|
|
|
|
SX-150 |
201⁄8 |
265⁄8 |
_ |
6 |
47 |
SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600 |
SX-180 |
231⁄8 |
295⁄8 |
_ |
7 |
483⁄16 |
||||
SX-210 |
261⁄8 |
325⁄8 |
_ |
7 |
483⁄16 |
|||||
FAX: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario |
|
|
|
|
|
|
||||
|
|
|
|
|
|
www.slantfin.com |
©Slant/Fin Corp. 2007 |