Slant-Fin Intrepid TR User Manual

RATINGS CHART – OIL BOILERS
®
INTREPID TR SERIES - WATER
D.O.E.
Heating
Capacity
MBH
Water
Steam
I=B=R Burner
Net Ratings
Water
Steam
MBH
MBH
Steam Sq. Ft.
I=B=R Chimney Size
Nom. Rect.
x Height
(in x in x ft)
§
I.D.Round
x Height
(in x ft)
A.F.U.E.
Water
%
Steam
Boiler
Length
“A”
Boiler Model
No.
I=B=R Burner
Capacity Oil Input
GPH
BTUH
TR-20 0.75 105,000 91 79 8 x 8 x 15 5 x 15 83.50 111⁄ TR-30H 1.00 140,000 121 105 8 x 8 x 15 6 x 15 86.00 14
TR-30
1.10 154,000 134 134 117 101 421 8 x 8 x 15 6 x 15 84.85 84.15 147⁄8 101⁄32 611⁄4 275⁄8 3 3.20 3.00
1.25 175,000 151 131 8 x 8 x 15 6 x 15 83.50 14
TR-40H 1.50 210,000 182 179 158 134 558 8 x 8 x 15 6 x 15 86.00 84.00 18
TR-40
1.60 224,000 195 195 170 146 608 8 x 8 x 15 7 x 1 5 84.45 83.80 181⁄4 1123⁄32 7 11⁄4 31 4 3.90 3.50
1.80 252,000 218 190 8 x 8 x 15 7 x 15 83.33 18
TR-50H 2.00 280,000 243 239 211 179 746 8 x 8 x 15 7 x 15 86.00 84.00 21
TR-50
TR-60
2.10 294,000 256 255 223 191 796 8 x 8 x 15 8 x 15 84.06 83.45 215⁄8 1313⁄32 8 11⁄2 343⁄8 5 4.40 4.00
2.35 329,000 272
2.60 364,000 298#298#259 224 933 8 x 12 x 15 10 x 15 25 153⁄32 811⁄2 373⁄4 6 4.90 4.50
#
237 8 x 12 x 15 8 x 15 215⁄
2.85 399,000 327#— 284 8 x 12 x 15 10 x 15 25 153⁄32 811⁄2 373⁄4 6 5.20
TR-70
3.10 434,000 352#354#306 266 1108 8 x 12 x 15 10 x 15 283⁄8 1625⁄32 9—411⁄
3.35 469,000 381#— 331 8 x 12 x 15 10 x 15 283⁄8 1625⁄32 9—411⁄8 7 5.70
Dimensions (inches)
Boiler
Return
Front to
Flue
“B”
89⁄
2
7
101⁄
8
7
8 101⁄32 6 11⁄4 275⁄8 3 3.40
1
11
4
1
4 1123⁄32 711⁄
5
8 1313⁄32 8 11⁄2 343⁄8 5 4.40 3.90
8
13
Flue
Circulator
Dia.
¢
32
32
2
3
32
1
3
32
“C”
6
611⁄
711⁄
8 11⁄
Flange
“D”
11⁄
4
4
4
4
2
section
Overall Length
“E”
241⁄
4
275⁄
8
31 4 3.80 3.40
31 4 4.15
8
343⁄
8
Tankless
Heater
**
GPM
Water
Steam
2 2.20 — 3 3.00
5 4.70
7 5.45 5.00
* Add Suffix: (P)Packaged water boiler less tankless heater, (PT)Packaged water boiler with tankless heater, (PPT)Packaged water boiler with provision for tankless heater, (PZ)Packaged steam boiler less
tankless heater, (PZT)P † Ratings apply to the use of light oil at 140,000 Btu per gallon, and a .02% draft (negative pressure) over the fire. ‡ The net I=B=R output ratings shown are based on an allowance for piping and pickup of 1.15 (water) or 1.33 (steam). D.O.E. capacity gross output is divided by the allowance to obtain net rating.
The manufacturer should be consulted before selecting a boiler for unusual piping and pickup requirements such as intermittent system operation, extensive piping, etc.
§ Nominal clay tile liner dimensions. ** Tankless heater rating based on intermittent draw. ¶ Water boiler models TR-30, TR-40, TR-50, TR-60 and TR-70 have two firing rates. The boiler is factory shipped at the lower firing rate. To obtain the higher firing rate, refer to the Intrepid boiler installation
instructions for the appropriate field adjustments. # I.B.R. gross output Collar is oblong, will fit 6" diameter nominal connector.
NOTE: All boilers under 300,000 Btuh input are tested and rated for capacity under the U.S. Department of Energy (D.O.E.) Test Procedures for Boilers.å
ackaged steam boiler with tankless heater.
SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600
FAX: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com
©Slant/Fin Corp. 2007