Slant-Fin B-200, B-120 User Manual

®
RATINGS CHART – GAS BOILERS
BOBCAT
Modulating, Condensing - High Efficiency
SPECIFICATIONS:
Fuel Rate Input:
Boiler Water Volume:
Water Piping
Connections:
Weight of Boiler
(uncrated):
Gas orifice size:
Gas Piping Connection:
Vent Connection:
Air Intake Connection:
*Note: No orifice changes are required for high altitude installations.
B-120 Boiler B-200 Boiler
120,000 BTUH max
30,000 BTUH min
1.0 gallon (8.3 lbs) 1.4 gallon (11.07 lbs)
1” NPT (male)
145 lbs. 200 lbs.
Natural Gas - No orifice used*
Propane - .2025” inside
diameter
3” nominal I.D. pipe (PVC, CPVC or stainless steel)
3” nominal I.D. pipe (PVC, CPVC or stainless steel)
**
1/2” NPT (female)
200,000 BTUH max
50,000 BTUH min
Propane - .250” inside
diameter
**
SLANT/FIN CORPORA
FAX: (516) 484-5921 • In Canada:
TION, Greenvale, NY 11548 • Phone: (516) 484-2600
Slant/Fin LTD/LTEE, Mississauga, Ontario
©Slant/Fin Corp. 2007