Skyrc D1000 V2 User Manual

AC/DC Dual Balance Charger Discharger / Power Supply
V2
Instruction Manual
[Version 1.20]
Table of Contents
Introduction
Special Features
Warning and Safety Notes
Explanation of Buttons
Operating Program
Lithium Battery Program (LiPo/LiFe/LiIon/LiHV)
NiMH/NiCd Battery Program
Pb Lead-acid Battery Program
DC Power Supply
Battery Memory Set and Call Out
System Setting
Battery Voltage Meter
Battery Resistance Meter
Controlling the Charger Using the App
Using the Charge Control Software “Charge Master”
Specification
Regulatory Information
Warranty and Service
01
03
06
10
13
15
18
22
24
25
27
29
30
31
37
38
39
42
WARNING:
This charger is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the charger. Do not recharge non-rechargeable batteries!
During charging, the battery must be placed in a well-ventilated area! Never leave the charger unattended when charging the battery.
Introduction
Congratulations on your choice of SKYRC D100v2 AC/DC Dual Balance Charger/Discharger/Power Supply. This unit is simple to use, but the operation of a sophisticated automatic charger such as SKYRC D100v2 does require some knowledge on the part of the user. These operating instructions are designed to ensure that you quickly become familiar with its functions. It is therefore important that you read right through the Operating Instructions, Warning and Safety Notes before you attempt to use your new charger for the first time. We hope you have many years of pleasure and success with your new battery charger.
SKYRC D100v2 is a twin-channel charger with two independent circuits which can charge batteries of varying chemistries (LiPo/LiFe/Lilon/LiHV/NiMH/NiCd/ Pb) simultaneously. Capable of operating as a power supply with the maximum output of 100W helps the hobbyists to power other DC equipments. With its unprecedented function of voice guide, even a freshman can operate this charger easily. Additional feature including our "SCAN TO GO" and smart phone control via Bluetooth.
Please BE SURE to read these INSTRUCTIONS, WARNING and SAFETY NOTES before you use the charger for the first time.
It can be dangerous to mis-handle batteries and battery chargers, as there is always a risk of batteries catching fire and exploding.
Mishandling batteries and battery chargers is extremely dangerous, which may cause fire and explosion.
D100v2
01 ·
Introduction
Please read this entire operating manual completely and attentively before using this product, as it covers a wide range of information on operating and safety. Or please do use this product in company with a specialist!
Dot Matrix 128x64 LCD Display
Output Socket
4mm Banana Plug
Balance Lead Socket
Temperature
Sensor Port
USB Port
Micro USB Port for
PC Link &
firmware upgrade
Temperature
Sensor Port
Resume or Start Charge Processes
Balance Lead Socket
Output Socket
4mm Banana Plug
Alter Values See the Status of Individual Cells in Balance Charge Mode
Cooling Fan
Scroll Through the Main Menu Stop Any Charge Processes
Switch from Channel A to B or Channel B to A
DC Power LED Light
DC Input: 11-18V DC Output: 13.8V
· 02
Speaker
AC Input 100-240V
D100v2
Special Features
LiPo
NiMH
Twin-channel Charger
SKYRC D100v2 allows you to plug 2 batteries into one charger simultaneously, and it will intelligently and automatically charge 2 battries at once to their maximum capacity. To top of it, the batteries being charged do not even need to have the same configuration. You can connect different chemistry(LiPo/LiFe/Lilon/LiHV/NiMH/NiCd/Pb)batteries into any of the charging ports.
Dual Input and Power Distribution
The input of the charger is AC 100-240V and DC 11-18V. In DC mode, the power of each channel is 100W. Total power is 200W. In AC mode, it supports power distribution, between Channel A, Channel B & Power Supply. For example, if both channel A and channel B are set to 40W, then, the DC power is 20W. The total power is 100W. (40W+40W+20W=100W)
Optimized Operating Software
SKYRC D100v2 features the so-called AUTO function that sets the feeding current during the process of charging or discharging. Especially for lithium batteries, it can prevent the overcharging which may lead to an explosion due to the user's fault. It can disconnect the circuit automatically and alarm once detecting any malfunction. All the programs of this product were controlled through two way linkage and communication, to achieve the maximum safety and minimize the trouble. All the settings can be configured by users!
DC Power Output Supported
With the unique feature of DC power source, the user does not have to carry additional big and heavy power supply to the racing track or flying filed.
Voice Guide
Purposes to make the charger more intuitive and user friendly.
D100v2
03 ·
Special Features
Battery Memory (Data Store/Load)
The charger can store up to 10 different charge/discharge profiles for each channel. You can keep the data pertaining to program setting of the battery of continuous charging or discharging. Users can call out these data at any time without any special program setting.
Terminal Voltage Control(TVC)
The charger allows user to change the end voltage. (for expert user only)
PC Control Software “Charge Master”
The free “Charge Master” software gives you unparalleled ability to operate the charger through the computer. You can monitor pack voltage, cell voltage and other data during the charging, view charge data in real-time graphs. And you can initiate, control the charger from “Charge Master”.
Smart Phone Control via Bluetooth (both iOS and Android)
The charger can be operated with a smart phone via bluetooth connection.
SCAN TO GO
A very unique feature of D100v2 is SCAN TO GO (automatically charging system). As the range of battery types and capacity becomes more and more, each battery requires its own dedicated charging process. It is easy to set up the charger incorrectly for a specific type of battery, resulting damage the battery or even cause accident.
The revolutionary SCAN TO GO provides a solution to this problem by allowing the user to assign a QR Code which contains all the relevant data for the battery for charging or discharging. The user can create a unique QR Code by using “SkyCharger” apps. Print it and paste it on the battery.
Using your smart phone and launch “SkyCharger” app. Since all the essential information is stored in the QR Code. All you need to do is press the Scan button, and the charge or discharge process will start automatically.
Balancing Individual Cells Battery During Discharging
During the process of discharging, SKYRC D100v2 can monitor and balance each cell of the battery individually. Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal.
Fast Charge and Storage Mode of Lithium Battery
Function of the two modes differs from each other. “FAST CHG” minimizes battery charge time, while “STORAGE” has the capacity to control the final battery voltage, which is necessary and helpful for a rarely used battery.
Re-Peak Mode of NiMH/NiCd Battery
In re-peak charge mode, the charger can peak charge the battery once, twice or three times in a row automatically. This is good for making the battery fully charged.
· 04
D100v2
Special Features
Delta-peak Sensitivity for NiMH/NiCd
Delta-peak sensitivity for NiMH/NiCd battery: The automatic charge termination program based on the principle of the Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process will be terminated automatically.
Cyclic Charging/Discharging
1 to 5 cyclic and continuous process of charge > discharge or discharge > charge is operable for battery refreshing and balancing to stimulate the battery's activity.
Automatic Charging Current Limit
You can set up the upper limit of the charging current when charging your NiMH or NiCd battery, it is useful for the NiMH battery of low impedance and capacity in the 'AUTO' charging mode.
Battery Voltage Meter
The user can check battery's total voltage, the highest voltage, the lowest voltage and each cell's voltage.
Battery Internal Resistance Meter
The user can check battery's total internal resistance and each cell's internal resistance.
Capacity Limit
The charging capacity is always calculated as the charging current multiplied by time. If the charging capacity exceeds the limit, the process will be terminated automatically when you set the maximum value.
Temperature Threshold*
The battery's internal chemical reaction will cause the temperature of the battery to rise. If the temperature limit is reached, the process will be terminated.
This function is only available by connecting optional temperature probe, which is not included in the package.
*
Processing Time Limit:
You can also limit the maximum process time to avoid any possible defect.
USB Power 5V/2.1A
You can charge your phone and tablet using the built-in USB power output port.
D100v2
05 ·
Warning And Safety Notes
These warnings and safety notes are particularly important. Please follow the instructions for maximum safety; otherwise the charger and the battery can be damaged or at worst it can cause a fire.
Never leave the charger unattended when it is connected to its power supply. If any malfunction is found, TERMINATE THE PROCESS AT ONCE and refer to the operation manual.
Keep the charger well away from dust, damp, rain, heat, direct sunshine and vibration. Never drop it.
The allowable DC input voltage is 11~18V DC.
The allowable AC input voltage is 100~240V AC.
This charger and the battery should be put on a heat-resistant, non-inflammable and non-conductive surface. Never place them on a car seat, carpet or similar. Keep all the inflammable volatile materials away from operating area.
Make sure you know the specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger. If the program is set up incorrectly, the battery and charger may be damaged .It can cause fire or explosion due to overcharging.
Standard Battery Parameters
LiIon
3.6V/cell
4.1V/cell
3.7V/cell
1C
Nominal Voltage
Max Charge Voltage
Storage Voltage
Allowable Fast Charge
Min. Discharge Voltage
LiPo
3.7V/cell
4.2V/cell
3.8V/cell
1C
3.0-3.3V/cell 2.9-3.2V/cell
Be very careful to choose the correct voltage for different types of battery otherwise you may cause damage to the batteries. Incorrect settings could cause the cells to fire or explode.
LiFe
3.3V/cell
3.6V/cell
3.3V/cell
4C
2.6-2.9V/cell
LiHV
3.8V/cell
4.35V/cell
3.85V/cell
1C
3.1-3.4V/cell
NiCd
1.2V/cell
1.5V/cell
n/a
NiMH
1.2V/cell
1.5V/cell
n/a
1C-2C
0.1-1.1V/cell 0.1-1.1V/cell
1C-2C
Pb
2.0V/cell
2.46V/cell
n/a
0.4C
1.8V/cell
· 06
D100v2
Warning And Safety Notes
Never attempt to charge or discharge the following types of batteries.
A battery pack which consists of different types of cells (including different manufacturers) A battery that is already fully charged or just slightly discharged. Non-rechargeable batteries (Explosion hazard). Batteries that require a different charge technique from NiCd, NiMH, LiPo or Gel cell (Pb, Lead acid). A faulty or damaged battery. A battery fitted with an integral charge circuit or a protection circuit. Batteries installed in a device or which are electrically linked to other components. Batteries that are not expressly stated by the manufacturer to be suitable for the currents the charger delivers during the charge process.
Please bear in mind the following points before commencing charging:
Did you select the appropriate program suitable for the type of battery you are charging? Did you set up adequate current for charging or discharging? Have you checked the battery voltage? Lithium battery packs can be wired in parallel and in series, i.e. a 2 cell pack can be 3.7V (in parallel) or 7.4V (in series). Have you checked that all connections are firm and secure? Make sure there are no intermittent contacts at any point in the circuit.
Charging
During charge process, a specific quantity of electrical energy is fed into the battery. The charge quantity is calculated by multiplying charge current by charge time. The maximum permissible charge current varies depending on the battery type or its performance, and can be found in the information by the battery manufacturer. Only batteries that are expressly stated to be capable of quick-charge are allowed to be charged at rates higher than the standard charge current.
Connect the battery to the terminal of the charger: red is positive and black is negative. Due to the difference between resistance of cable and connector, the charger can not detect resistance of the battery pack, the essential requirement for the charger to work properly is that the charge lead should be of adequate conductor cross-section, and high quality connectors which are normally gold­plated should be fitted to both ends.
Always refer to the manual by battery manufacturer about charging methods, recommended charging current and charging time. Especially, the lithium battery should be charged according the charging instruction provided by the manufacturer strictly.
D100v2
07 ·
Warning And Safety Notes
Attention should be paid to the connection of lithium battery especially.
Do not attempt to disassemble the battery pack arbitrarily.
Please get highlighted that lithium battery packs can be wired in parallel and in series. In the parallel connection, the battery’s capacity is calculated by multiplying single battery capacity by the number of cells with total voltage stay the same. The voltages imbalance may cause fire or explosion .Lithium battery is recommended to charge in series.
Discharging
The main purpose of discharging is to clean residual capacity of the battery, or to reduce the battery voltage to a defined level. The same attention should be paid to the discharging process as charging. The final discharge voltage should be set up correctly to avoid deep-discharging. Lithium battery can not be discharged to lower than the minimum voltage, or it will cause a rapid loss of capacity or a total failure. Generally, lithium battery doesn't need to be discharged. Please pay attention to the minimum voltage of lithium battery to protect the battery.
Some rechargeable batteries have a memory effect. If they are partly used and recharged before the whole charge is accomplished, they remember this and will only use that part of their capacity next time. This is a memory effect. It is said that NiCd and NiMH batteries are suffering from memory effect. NiCd has more memory effect than NiMH.
· 08
D100v2
Program Flow Chart
Note: The flow chart is taking one channel for example as the flow chart for the two channels (Channel A and Channel B) are identical.
DECINC
DECINC
DECINC
DECINC
DECINC
NiMH BATT
DECINC
NiCd BATT
DECINC
Pb BATT
DECINC
BATT METER
DECINC
DECINC
DECINC
Stop
Batt Type
ENTER
START
ENTER
START
START
ENTER
START
ENTER
START
ENTER
START
ENTER
START
ENTER
START
ENTER
START
ENTER
START
ENTER
START
ENTER
START
ENTER
START
ENTER
BATT/PROGRAM LiPo BATT
BATT/PROGRAM LiFe BATT
BATT/PROGRAM LiIo BATT
BATT/PROGRAM LiHV BATT
BATT/PROGRAM
BATT/PROGRAM
BATT/PROGRAM
BATT/PROGRAM
BATT/PROGRAM BATT RESISTANCE
BATT/PROGRAM SYSTEM SETTING->
BATT/PROGRAM BATT MEMORY
LiPo BALANCE
2.0A 7.4V (2S)
LiFe BALANCE
2.0A 6.6V (2S)
Lilo BALANCE
2.0A 7.2V (2S)
LiHV BALANCE
2.0A 7.6V (2S)
NiMH CHARGE CURRENT 2.0A
NiCd CHARGE CURRENT 2.0A
Pb CHARGE
2.0A 2.0V (1P)
4.20 4.19 4.19 V
0.00 0.00 0.00 V
005 003 003 mΩ 005 mΩ
DC SUPPLY: OFF CH1: 50 CH2:50W
Version HW:1.00 FW: 2.00
[ BATT MEMORY 1 ] ENTER SET->
STARG/ENTER>3Seconds
ENTER CHARGER LOAD……
[ BATT MEMORY 2 ] ENTER SET->
[ BATT MEMORY 2 ] C:1.0A D:1.0A
START
ENTER CHARGER LOAD……
[ BATT MEMORY 3 ] ENTER SET->
Pb CHARGE
3.3A 4.0V(2P)
Pb DISCHARGE
1.5A 4.0V(2P)
ENTER > 3s
INC
LiPo CHARGE
2.0A 7.4V (2S)
DEC
INC
LiFe CHARGE
2.0A 6.6V (2S)
DEC
INC
Lilo CHARGE
2.0A 7.2V (2S)
DEC
INC
LiHV CHARGE
2.0A 7.6V (2S)
DEC
INC
NiMH Auto CHARGE CURRENT 2.0A
DEC
INC
NiCd Auto CHARGE CURRENT 2.0A
DEC
INC
Pb DISCHARGE
0.1A 2.0V (1P)
DEC
INC
MAIN 0.00V H0.000V L0.000V
DEC
INC
TATAL: 16mΩ H: 5mΩ L: 3mΩ
DEC
INC
Safety Timer ON 120Min
DEC
INC
Load Factory Set Enter
DEC
START
BATT TYPE LiPo
ENTER
[ BATT MEMORY 1 ] C:4.9A D:2.2A
LiPo BALANCE CHG
4.9A 7.4V(2S)
START
BATT TYPE MiMH
ENTER
[ BATT MEMORY 2 ] NiMH 2.4V (2S )
NiMH CHARGE CURRENT 1.0A
START
BATT TYPE Pb
ENTER
ENTER CHARGER LOAD……
INC
LiPo FAST CHG
2.0A 7.4V (2S)
DEC
INC
LiFe FAST CHG
2.0A 6.6V (2S)
DEC
INC
Lilo FAST CHG
2.0A 7.2V (2S)
DEC
INC
LiHV FAST CHG
2.0A 7.6V (2S)
DEC
INC
NiMH DISCHARGE
0.1A CUT: 1.0V
DEC
INC
NiCd DISCHARGE
0.1A CUT: 1.0V
DEC
INC
Capacity Cut-Off ON 5000mAH
DEC
INC
DEC
INC
BATT VOLTAGE
7.4V ( 2S )
DEC
[ BATT MEMORY 1 ] LiPo 7.4V (2S )
INC
LiPo CHARGE
4.9A 7.4V(2S)
DEC
INC
BATT VOLTS
2.4V (2S)
DEC
SAVE PROGRAM SAVE….
INC
NiMH Auto CHARGE CURRENT 1.2A
DEC
INC
BATT VOLTS
4.0V (2P)
DEC
[ BATT MEMORY 3 ] C:3.3A D:1.5A
STARG/ENTER>3s
DC Input Low CUT-OFF 11.0V
INC
LiPo STORAGE
2.0A 7.4V (2S)
DEC
INC
LiFe STORAGE
2.0A 6.6V (2S)
DEC
INC
Lilo STORAGE
2.0A 7.2V (2S)
DEC
INC
LiHV STORAGE
2.0A 7.6V (2S)
DEC
INC
NiMH RE-PEAK 1
DEC
INC
NiCd RE-PEAK 1
DEC
INC
Temp Cut-Off ON 50°C 122°F
DEC
INC
Key Beep ON Voice ON
DEC
INC
CHARGE CURRENT
4.9A
DEC
SAVE PROGRAM SAVE….
INC
LiPo FAST CHARGE
4.9A 7.4V(2S)
DEC
INC
CHARGE CURRENT
3.3A
DEC
START
SAVE PROGRAM
ENTER
INC
NiMH DISCHARGE
1.0A CUT: 2.0V
DEC
INC
CHARGE CURRENT
3.3A
DEC
[ BATT MEMORY 3 ] Pb 4.0V (2S )
ENTER
INC
LiPo DISCHARGE
2.0A 7.4V (2S)
DEC
INC
LiFe DISCHARGE
2.0A 6.6V (2S)
DEC
INC
Lilo DISCHARGE
2.0A 7.2V (2S)
DEC
INC
LiHV DISCHARGE
2.0A 7.6V (2S)
DEC
INC
NiMH CYCLE CHG>DCHG 1
DEC
INC
NiCd CYCLE CHG>DCHG  1
DEC
INC
Temperature Unit Celsius
DEC
INC
NiCd Sensitivity D.Peak  4mV
DEC
INC
DISCHG CURRENT
2.2A
DEC
START
SAVE PROGRAM ENTER
ENTER
INC
LiPo STORAGE
4.9A 7.4V(2S)
DEC
INC
TRICKLE 100mA
DEC
INC
DSCH VOLTAGE
1.1V/CELL
DEC
INC
NiMH RE-PEAK 2
DEC
INC
DSCH CURRENT
1.5A
DEC
SAVE PROGRAM SAVE….
INC
Rest Time CHG>DCHG 10Min
DEC
INC
NiMH Sensitivity D.Peak  4mV
DEC
INC
DISCHG VOLTAGE
3.0V/CELL
DEC
INC
TVC=YOUR RISK !
4.20V
DEC
INC
LiPo DISCHARGE
2.2A 7.4V(2S)
DEC
INC
PEAK DELAY 1Min
DEC
INC
DSCH CURRENT
2.2A
DEC
INC
NiMH CYCLE DCHG>CHG 1
DEC
INC
DSCH VOLTAGE
1.7V/CELL
DEC
START
SAVE PROGRAM
ENTER
DECINC
DECINC
DECINC
DECINC
ENTER
D100v2
09 ·
Explanation of Buttons
CH A/CH B: It is used to switch from Channel A to B or vice versa.
BATT PROG / STOP Button: It is used to stop the progress or go back to previous step/screen
DEC Button: It is used to go through the menus and decrease the parameter value
INC Button: It is used to go through the menus and increase the parameter value
ENTER / START Button: It is used to enter parameter, store parameter on screen and start the program.
When you are willing to alter the parameter value in the program, press the START/ENTER button to make it blink then change the value by pressing DEC and INC button. The value will be stored by re-pressing the START/ENTER button. If there is another parameter can be altered in the same screen, when you confirm the first parameter value, the next parameter value will start to blink which means it is ready to alert.
When you are willing to start the process, press and hold the START/ENTER button for 3 seconds. When you are willing to stop the progress or go back to previous step/screen, press the BATT PROG/STOP button once.
· 10
D100v2
Power and Battery Connection
1. Connecting to power source
There are two kinds of inputs for SKYRC D100v2, DC 11-18V and AC 100-240V.
AC 100-240V power source connection.
12V DC Battery / DC power supply connection.
XT60
D100v2
11 ·
Power and Battery Connection
Note: We will explain the operating procedure of one channel as the procedure for channel A and B is identical.
2. Connecting the battery
TO AVOID SHORT CIRCUITS, ALWAYS CONNECT THE CHARGE LEADS TO THE CHARGER FIRST, AND THEN TO THE BATTERY. REVERSE THE
WARNING!
SEQUENCE WHEN DISCONNECTING THE PACK.
1) LiPo Battery Connection with Balance Adapter
LiPo
Balance Socket
For safety reasons, the default setting for charging Lithium (LiPo, Lilon, LiFe and LiHV) battery is using balance adaptor to connect battery and charger in Charge, Fast Charge, Balance Charge, Discharge and Storage modes. But if the battery comes without balance wire,please proceed with the prompting message "No balance cable detected, push enter to continue".
The balance wire attached to the battery must be connected to the charger with the black wire aligned with the negative marking. Ensure correct polarity!
2) NiMH/NiCd or Pb Battery Connection
· 12
NiMH
D100v2
Loading...
+ 30 hidden pages