Skyrc B6AC+ DUAL POWER,imax b6ac version 2 Instruction Manual

SkyRC Technology Co., Ltd. 2014
Version 1.0
Version 2
AC/DC Professional Balance Charger/Discharger
TABLE OF CONTENTS
INTRODUCTION
WARNING AND SAFETY NOTES
PROGRAM FLOW CHART
OPERATION
OPERATING PROGRAM
CHARGING PROGRAM
BATTERY MEMORY SET AND CALL OUT
SYSTEM SETTING
BATTERY METER
BATTERY RESISTANCE METER
WARNING AND ERROR MESSAGE
USING THE CHARGE CONTROL SOFTWARE “CHARGE MASTER”
THE SET CONTAINS
SPECIFICATION
CONFORMITY DECLARATION
COMMONLY USED TERMS
WARRANTY AND SERVICE
01
03
05
08
09
10
13
14
16
18
19
20
21
21
22
23
24
25
Congratulations on your choice of SKYRC B6AC+ Version 2(V2) AC/DC Input Professional Balance Charger/Discharger. This unit is simple to use, but the operation of a sophisticated automatic charger such as SKYRC B6AC+ does require some knowledge on the part of the user. These operating instructions are designed to ensure that you quickly become familiar with its functions. It is therefore important that you read right through the Operating Instructions, Warning and Safety Notes before you attempt to use your new charger for the first time. We hope you have many years of pleasure and success with your new battery charger.
SKYRC B6AC+ V2 is the upgraded version for well-known IMAX B6AC+. Compared with B6AC+ V1, it is more accurate and stable and also has some new features and functions. Users could set the terminal voltage by themselves and connect it to PC for PC control and firmware upgrade. What's more, users could also use it as Lithium Battery Meter and Battery Internal Resistance Meter. There are Automatic Charging Current Limit, Capacity Limit, Temperature Threshold and Processing Time Limit which makes the charger safer than V1.
SKYRC B6AC+ V2 is a high-performance, micro processor control charge/discharge station with battery management suitable for use with all current battery types, with integral equalizer for six-cell Lithium­Polymer (LiPo), Lithium iron phosphate(LiFe) and Lithium-Ion (LiIon) batteries; maximum 6A charge current and maximum 50W charge power. It can be powered by 11-18V DC source or from 100V-240V via the built in switch-mode power supply.
Please BE SURE to read these INSTRUCTIONS, WARNING and SAFETY NOTES before you use the charger for the first time.
It can be dangerous to mis-handle batteries and battery chargers, as there is always a risk of batteries catching fire and exploding.
INTRODUCTION
01 ·
B6AC+ V2
INTRODUCTION
· 02
Please read this entire operating manual completely and attentively before using this product, as it covers a wide range of information on operating and safety. Or please do use this product in company with a specialist!
B6AC+ V2
Balance Lead Socket JST-XH Ports
Output Charge Lead 4mm Banana Plug
LCD Display
Scroll Through the Main Menu Stop Any Charge Processes
Alter Values See the Status of Individual Cells in Balance Charge Mode
Resume or Start Charge Processes Confirm Any Action
AC Input Power Port AC 100-240V 50-60Hz
DC Input Power Port DC 11-18V
Micro USB Port for PC Link / WiFi Module Connection
Temperature Sensor Port
SPECIAL FEATURES
Optimized Operating Software
SKYRC B6AC+ V2 features the so-called AUTO function that set the feeding current during the process of charging or discharging. Especially for lithium batteries, it can prevent the overcharging which may lead to an explosion due to the user's fault. It can disconnect the circuit automatically and alarm once detecting any malfunction. All the programs of this product were controlled through two way linkage and communication, to achieve the maximum safety and minimize the trouble. All the settings can be configured by users!
Battery Memory (Data Store/Load)
The charger can store up to 10 different charge/discharge profiles for your convenience. You can keep the data pertaining to program setting of the battery of continuous charging or discharging. Users can call out these data at any time without any special program setting.
Terminal Voltage Control(TVC)
The charger allows user to change the end voltage. (for expert user only)
PC Control Software “Charge Master”
The free “Charge Master” software gives you unparalleled ability to operate the charger through the computer. You can monitor pack voltage, cell voltage and other data during the charging, view charge date in real-time graphs. And you can initiate, control charging and update firmware from “Charge Master”.
Internal Independent Lithium Battery Balancer
SKYRC B6AC+ V2 employs an individual-cell-voltage balancer. It isn't necessary to connect an external balancer for balance charging.
Balancing Individual Cells Battery Discharging
During the process of discharging, can monitor and balance each cell of the battery individually. Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal.
SKYRC B6AC+ V2
Adaptable to Various Type of Lithium Battery
SKYRC B6AC+ V2 is adaptable to various types of lithium batteries, such as LiPo, LiIon and the new LiFe series of batteries.
03 ·
B6AC+ V2
Smart Phone Control via WiFi Module (both iOS and Android)
Finally, your charger gets its own apps. This charger can be controlled and operated by
smart phones via WiFi module(option part SK-600075).
SPECIAL FEATURES
Cyclic Charging/Discharging
1 to 5 cyclic and continuous process of charge > discharge or discharge > charge is operable for battery refreshing and balancing to stimulate the battery's activity.
Re-Peak Mode of NiMH/NiCd Battery
In re-peak charge mode, the charger can peak charge the battery once, twice or three times in a row automatically. This is good for making certain the battery is fully charged.
Delta-peak Sensitivity for NiMH/NiCd
Delta-peak sensitivity for NiMH/NiCd battery: The automatic charge termination program based on the principle of the Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process will be terminated automatically.
Automatic Charging Current Limit
You can set up the upper limit of the charging current when charging your NiMH or NiCd battery, it is useful for the NiMH battery of low impedance and capacity in the 'AUTO' charging mode.
Capacity Limit
The charging capacity is always calculated as the charging current multiplied by time. If the charging capacity exceeds the limit, the process will be terminated automatically when you set the maximum value.
Temperature Threshold*
The battery's internal chemical reaction will cause the temperature of the battery to rise. If the temperature limit is reached, the process will be terminated.
This function is available by connecting optional temperature probe, which is not included in the package.
*
Processing Time Limit:
You can also limit the maximum process time to avoid any possible defect.
Battery Internal Resistance Meter
The user can check battery's total internal resistance and each cell's internal resistance.
LiPo Battery Meter
The user can check battery's total voltage, the highest voltage, the lowest voltage and each cell's voltage.
· 04
B6AC+ V2
Fast and Storage Mode of Lithium Battery
Purposes to charge lithium battery varies, 'fast' charge reduce the duration of charging, whereas 'store' state can control the final voltage of your battery, so as to store for a long time and protect useful time of the battery.
These warnings and safety notes are particularly important. Please follow the instructions for maximum safety; otherwise the charger and the battery can be damaged or at worst it can cause a fire.
Never leave the charger unattended when it is connected to its power supply. If any malfunction is found, TERMINATE THE PROCESS AT ONCE and refer to the operation manual.
Keep the charger well away from dust, damp, rain, heat, direct sunshine and . Never drop it.
vibration
The allowable DC input voltage is 11~18V DC
This charger and the battery should be put on a heat-resistant, noninflammable and nonconductive surface. Never place them on a car seat, carpet or similar. Keep all the inflammable volatile materials away from operating area.
Make sure you know the specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger. If the program is set up incorrectly, the battery and charger may be damaged .It can cause fire or explosion due to overcharging.
Standard Battery Parameters
Be very careful to choose the correct voltage for different types of battery otherwise you may cause damage to the batteries. Incorrect settings could cause the cells to fire or explode.
3.7V/cell
Nominal Voltage
Min. Discharge Voltage
Max Charge Voltage
Storage Voltage
Allowable Fast Charge
3.7V/cell
4.2V/cell
3.8V/cell
1C
LiPo
LiIon
3.6V/cell
4.1V/cell
1C
3.3V/cell
3.6V/cell
3.3V/cell
4C
LiFe
1.2V/cell
1.5V/cell
n/a
1C-2C
NiCd
1.2V/cell
1.5V/cell
n/a
1C-2C
MiMH
2.0V/cell
2.46V/cell
n/a
0.4C
Pb
WARNING AND SAFETY NOTES
3.0-3.3V/cell 2.9-3.2V/cell
2.6-2.9V/cell 0.1-1.1V/cell 0.1-1.1V/cell
1.8V/cell
The allowable AC input voltage is 100~240V AC
05 ·
B6AC+ V2
A battery pack which consists of different types of cells (including different manufacturers) A battery that is already fully charged or just slightly discharged. Non-rechargeable batteries (Explosion hazard). Batteries that require a different charge technique from NiCd, NiMh, LiPo or Gel cell (Pb, Lead acid). A faulty or damaged battery. A battery fitted with an integral charge circuit or a protection circuit. Batteries installed in a device or which are electrically linked to other components. Batteries that are not expressly stated by the manufacturer to be suitable for the currents the charger delivers during the charge process.
Please bear in mind the following points before commencing charging:
Did you select the appropriate program suitable for the type of battery you are charging? Did you set up adequate current for charging or discharging? Have you checked the battery voltage? Lithium battery packs can be wired in parallel and in series, i.e. a 2 cell pack can be 3.7V (in parallel) or 7.4V (in series). Have you checked that all connections are firm and secure? Make sure there are no intermittent contacts at any point in the circuit.
Charging
During charge process, a specific quantity of electrical energy is fed into the battery. The charge quantity is calculated by multiplying charge current by charge time. The maximum permissible charge current varies depending on the battery type or its performance, and can be found in the information by the battery manufacturer. Only batteries that are expressly stated to be capable of quick-charge are allowed to be charged at rates higher than the standard charge current.
Connect the battery to the terminal of the charger: red is positive and black is negative. Due to the difference between resistance of cable and connector, the charger can not detect resistance of the battery pack, the essential requirement for the charger to work properly is that the charge lead should be of adequate conductor cross-section, and high quality connectors which are normally gold­plated should be fitted to both ends.
Always refer to the manual by battery manufacturer about charging methods, recommended charging current and charging time. Especially, the lithium battery should be charged according the charging instruction provided by the manufacturer strictly.
Never attempt to charge or discharge the following types of batteries.
WARNING AND SAFETY NOTES
· 06
B6AC+ V2
Discharging
The main purpose of discharging is to clean residual capacity of the battery, or to reduce the battery voltage to a defined level. The same attention should be paid to the discharging process as charging. The final discharge voltage should be set up correctly to avoid deep-discharging. Lithium battery can not be discharged to lower than the minimum voltage, or it will cause a rapid loss of capacity or a total failure. Generally, lithium battery doesn't need to be discharged. Please pay attention to the minimum voltage of lithium battery to protect the battery.
Some rechargeable batteries have a memory effect. If they are partly used and recharged before the whole charge is accomplished, they remember this and will only use that part of their capacity next time. This is a memory effect. It is said that NiCd and NiMH batteries are suffering from memory effect. NiCd has more memory effect than NiMH.
Attention should be paid to the connection of lithium battery especially.
Do not attempt to disassemble the battery pack arbitrarily.
Please get highlighted that lithium battery packs can be wired in parallel and in series. In the parallel connection, the battery s capacity is calculated by multiplying single battery capacity by the number of cells with total voltage stay the same. The voltages imbalance may cause fire or explosion .Lithium battery is recommended to charge in series.
WARNING AND SAFETY NOTES
07 ·
B6AC+ V2
Loading...
+ 19 hidden pages