SkylinkHome lD-318 User Manual

Motion
Sensor
ModellD-318
Thank
you
for
your purchase
a SkylinkHome-" Motion Sensor, Model
lD-318.
The
Motion Sensor allows
you
to. activate a receiver module to
turn
lights
on automatically when movement
is detected. A built-in count-
down timer can turn lights
off after a
predefined
time
period.
This is ideal
for energy saving
purpose
where
an area is not
always occupied
but
lighting is needed when
someone is
present.
A
built-in
light
sensor
can
also
be
used so the lights will not be on when
the monitored area
is
bright
enough even if movement is detected
there.
All
wireless
signal communications within the
SkylinkHome-" System
are
based on
rolling
code technology to ensure
highest security
is
used.
The following items are included in this
package:
-
Motion Sensor lD-318
-
Ball Joint and Mounting
Accessories
-
User's
lnstructions
/
Ball Joint and Mounting Accessories
1. Undo the screw on the battery door and remove
the battery
door from
the sensor.
1) Use another
transmitter with
on / off function to turn
off
the load,
2) Turn off the
light manually
by the wall switch
(if
the load is
connected
to a wall
switch)
3)Activate the
motion
sensor so that the light will be
off after the
countdown timer.
You may
program
the motion sensor to different receiver
modules, so when
the motion sensor
is activated, all the receiver
modules will be activated.
SEN 2
(Low)
smin/30min/60min
CDS OFF
2. lnsert
a 9V alkaline battery
(Not
included)
to the sensor
and
its LED
on the
front will
be on for 2 seconds.
3. You may leave the battery
door open
until all
pro-
gramming
steps are completed,
Then
tighten the screw on the
battery door.
ln order to activate a receiver module for
automatic control with a Motion
Sensor, it must
be
programmed
to the receiver module.
To
program
a
remote
to the
receiver
module,
a
"Learn"
code
must be
transmitted,
follow
the instructions below to transmit
the
"Learn"
code to
the
receiver.
'1
. Undo the door
screw
on the
back of the motion
sensor
and remove the
battery compartment
door.
2. Put the receiver module that
you plan
to
program
into
programming
mode. Refer
to the User's
lnstructions
of that receiver
module.
Note: For receiver
modules such as PA-318, PR-318,
PL-318, LS-318,
WR-001, WE-001,
you
can
program
the Motion
Sensor either in
On
/ Off mode
or Countdown Timer Mode,
either way the activation of
the Motion Sensor will result in timer
operation. lf
you
want
the
light to
stay on after motion is detected, refer
to Section 4
of this manual.
Some
receiver
modules have Flashing Alert
Mode, if the Motion Sensor
is
programmed
under this operating
mode, the light will flash for a fixed
time
period
when
movement is detected.
CDS DARK
SEN
1,
SEN
2
-
SEN 1 for high
sensitivity, SEN2 for low sensitivity. The
sensor
in high
sensitivity can monitor further
movement, up to about
11 meters and less movement
is required for
activation. The sensor in low
sensitivity can monitor
movement within a shorter
distance and more move-
ment is required for
activation. Set the
jumper
connector at either one of
this
positions.
SET Button - For
programming
the Motion Sensor.
5 min / 30 min
/ 60 min
-
For
setting the countdown timer duration. For
example,
you
may set the
connector at the 5 min
position
so
the
light
will
be on
when
a motion is
detected and be off 5 minutes later
if no more
motion is detected. Each of these receiver
modules, Model PA-318,
PR-318, PL-318, LS-318,
WE-001, WR-001,
has its own countdown
timer duration
setting.
However,
when a
motion
sensor is
programmed
to any one of these receiver
modules,
the motion sensor
timer
duration setting overrides
the timer duration setting
of the receiver
module. Therefore,
when movement is
detected by the motion
sensor, the
duration will
be based on the
motion sensor timer setting.
You
may also move
the timer
jumper
connector away,
(no
jumper
con-
nector at 5 / 30
/ 60 minute). ln
this case, the light
will be on when motion
is detected
and it will not
be turned off
by the built-in countdown
timer. You
must
use other device
such as a remote
control to turn it
off.
There
are
some situations where
this is desirable.
For example,
a motion
sensor
installed in a
conference room
will turn
on
the
lighting when
someone walks
into the room,
and the
lighting should remain
on until
someone leaves the
room
and
turns
off the lighting
manually.
Without this
setting
(no
timer),
during the meeting,
the
lighting may
be turned off if no
movement is in the
monitored
area.
CDS
(Light
Sensor)
OFF
-
lf the
jumper
connector is in
place,
the CDS
light sensing function
will
be disabled,
meaning even it is
very bright, if
movement is
detected
by the motion
sensor, it will
still send a
signal to
activate the receiver.
lf
the
jumper
connector
is removed,
light
sensor function will
be enabled,
meaning the
light will
only be on if motion
is detected
and the
brightness
the
monitored
area is low
enough.
Light Sensor Enabled
CDS DARK
(Light
Sensing Threshold) -
For
setting the light
sensing
threshold.
Jumper connector
To
customize
your
motion
sensor,
open
up the battery
compartment
door and
set
the
jumper
connectors
according to
your
needs.
Motion Sensor lD-318
LED underneath
the lens
3. Once the receiver is in
programmtng
mode,
you
can transmit a "Learn"
code from the
Motion
Sensor by
pressing
the "SET"
button
on
the Motion
Sensor.
4. Once the motion
sensor
is
programmed,
the
receiver module will
quit
from
programming
mode. Programming is now
completed.
Learn Code
SET
Button
Follow steps
3 above to transmit the
"Learn"
code when
programming
the
Motion
Sensor to receiver modules.
After
programming
the
Motion
Sensor to certain receivers, such as MR-318,
MD-318, LS-318,
LX-3'18, the connected load
(i.e.
the light)
may
stay
on
depending on the light status before
programming.
lf
the
light is on,
you
may turn off the light by the following methods:
:
i#f9,",
AJ
,.i
(R)
Fr\= I t-
\\\t/,4
\ \,/./
\I//
Light Sensor
:
lf the
jumper
connector
is in
place,
the
light sensor threshold
is
set
to
dark,
a motion activation
signal
will
not turn
on the lighting
receiver
unless
the environment
is really
dark.
lf
the
jumper
connector
is removed,
the
light sensor
threshold
is set to
dim,
a
motion activation
signal
will
turn
on the
lighting receiver
even the
environment
is not so dark.
You should
set the desired
light sensing
threshold by
trial and
error.
After
setting all
the
jumper
connectors,
you
may
place
the battery
com-
partment
door back
on
and tighten
the screw.
You may
now mount
the
motion sensor at
ihe desired
location
where movement
will
be monitored
You
can use
the mounting
accessories
to mount
the Motion
Sensor
on a
wall.
First, mount the
ball
joint
on the
wall, then slide the
Motion
Sensor
on
the balljoint.
You should
mount
it at a height of about
7ft
from
the
oround to achieve
better
coverage
_+
Type B)
Erase by Remote
-
Model LX-318, MD-318,
MR-318,
WE401
Erase by
Remote means there
is no erase button on
the receiver, so
a
programmed
transmitter is needed
in order to erase
the memory of
the
receiver.
You need to transmrt a
"Erase"
code from the
Remote. ln
this case,
the remote
is the Motion Sensor.
Follow the instructions
below to erase
the
Motion Sensor
from the receiver.
1.
Press and hold the SET button
on the
Motion Sensor
for
least 2 seconds.
Do not
release this button until
step 3.
2. Put the
receiver that
you
want
to erase the Motion
Sensor from
into
programming
mode. Refer to the
User's lnstructions
of that receiver
3. Once
the receiver receives
this
"Erase"
code,
the receiver
will indicate
it
has erased
all Motion Sensors
and other
transmitters, and
you
may
now
release the button on
the Motion Sensor.
Erase Code
Follow steps
2 and 3 above
to transmit the
"Erase" code
when erasing
the
Motion Sensor
from Type B
receivers.
When
the LED does
not flash
(ON
then OFF,
etc) after
the Motion
Sensor
is triggered
or when
the motion sensor does
not control
receiver after
movement
is detected,
it is time to
replace the battery. Refer
to Section
2
for detailed
instructions.
Note: Dispose of batteries
properly.
The Remote
Control is approved by
the FCC and it complies
with Part 15 of
the
FCC
Rules. lts operation is subject
to the following two
conditions :
1. This device may not cause
harmful interference.
2. This device
must accept any interference
that may cause
undesired operation.
WARNING: Changes
or modificalions to this unit
not expressly approved
by the
party
responsible
of compliance
could void the user's authority
to operate the equipment.
lf, within one
year
from date of
purchase,
this
product
should
become defective
(except
battery), due to faulty workmanship or
materials, it
will
be
repaired or
replaced,
without
charge.
Proof of
purchase
and a
Return Authorization are
required.
lf
you
would
like
to
- find
out
the up-to-date specifications
-
know more about features and applications
-
download
documents, i.e.
user's
instructions
-
order Skylink
products
or if
you
have
difficulty
getting
products
to work.
please:
'1.
visit our FAQ section at www.skylinkhome.com, or
2. email us at suoport@skylinkhome.com,
or
3.
call ourtoll free at'l-800-304-1187 from Mondayto
Friday,9 am to 5
pm
EST
Fax
(800) 286-1320
The SkylinkHome" System consists
of many other devices such
as
SkylinkPad'" Remotes, Motion Sensor, ON/OFF
Wall Switch,
Wall Dimmer,
Plug-ln Dimmer with or without Repeater, Plug-ln ON/OFF
Control
(Outdoor/lndoor),
Screw-ln
Dimmer, ON/OFF/Dimming Control,
ON/OFF
Control, Smart Button'" Garage
Door
Control, etc.
Please visit Skylink
website at www.skylinkhome.com
for
more
information.
CUSTOMER SERVICE
17 Sheard
Avenue, Brampton, Ontario, Canada
L6Y'1J3 Email:support@skylinkhome.com http://www.skylinkhome.com
P/N.1012702-001
Patent Pending
O2O'10 SKYLINK GROUP
#
Threshold
Bright
'.ffi
l.
Walk
Test
Walk test
should be
performed
after
the motion sensor
is mounted.
Walk
in the covered
area, if
motion is detected,
a red light
inside the
sensor
will flash.
lf the red light
does not flash,
motion has not
been detected
and
you
may need to
re-position the sensor.
Ensure
you
walk test
the
whole
area that
you
would
like the motion sensor
to cover.
Note:
-
Perform
the walk test
after
you
have
inserted the battery
for more
than
1 minute.
-
The sensor
will not be
triggered
by a
new motion unless
no motion
has been detected
for 3
seconds.
Therefore,
wait for at
least 3 seconds
during
walk testing to
make a next
movement.
-
Disable CDS Light Sensor
during
walk
test, re-enable
it after walk test
if needed.
Note:
When installing
the motion sensor,
avoid
placing
it near heat or
cold
producing
devices
(i.e.
A/C or
furnace vents, fans, ovens,
space
heaters,
etc), and
avoid
pointing
it to the moving objects
like a window
curtatn.
Air
movement,
especially
caused by
changes in temperature
may
trigger
the
Motion
Sensor. Please
carefully test
your
Motion Sensor
so that
it will
only
be triggered
by wanted
movement.
There
are 2 types of
receivers
and erasing transmitter
from
these 2
types
of receivers
are difierent.
Please
follow the erase
procedure
based
on
the
receiver
you
have.
Type
A)
Self
Erase
-
Model PL-318,
PR-318, PA-318,
LS-318,
WR401
Self
Erase
means there
is a erase button
on the receiver,
by
pressing
this
erase
button, all transmitters
can be erased.
To erase
transmitters
from these
receivers, simply
follow the instructions
of
these
receivers. The erase
procedure
does not involve
the transmitter.
DETECTING AREA:
(Unit
=
meter)
Loading...