SkyLink M6 Quick Manual

Page 1
2in1 Alert/Alarm System
Model: M6
Protect your Home the Smart Way!
Quick Guide
1. Safety Information
2 x Door/Window Sensor
Security Keypad
Mounting AccessoriesPower Adapter
2. Insert 4 x AAA-Batteries in the Main Console for backup power in case of power outage. (Optional)
2. Use a coin to open the Motion Sensor and insert an AA Battery.
Arm Home
Enter PIN number and press “Arm Home” to protect while you’re at home. This mode deactivates motion sensors but leaves other sensors activated.
Arm Away / Exit Away
Enter PIN number and press the “Arm Away” to protect your home when you’re away. This mode activates or triggers the alarm after a default set of time, giving you enough time to get in and out of your house to arm/disarm the alarm system.
Disarm
Enter PIN number and tap the Button to disarm the alarm system.
Panic Button
Press the Panic Button to activate the alarm.
Main Console
2 x Motion Sensor
www.skylinkhome.com
NOTE: 7 x AAA and 2 x AA-Batteries are required to setup the Alert/Alarm System. (AA/AAA Batteries are not included.)
2. Package Content 3. Setup the Main Console
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interferences that may cause undesired operation.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment complies with the requirements relating to electromagnetic compatibility, EN 301489-1, EN301489-3, EN300220-1, EN300220-2 and EN60950-1. This equipment conforms to the essential requirement of the 1999/5/EC R&TTE Directive.
Warning:
CE Declaration of Conformity
7. Main Console Overview
(FRONT)
(BACK)
AC Adapter
Input Jack
Mute Button
To disable the beep sound temporary
.
Learn Button
To program and erase sensors.
Alert Notification Switch
Select the type of audio alert signal. OFF | CHIME | ALERT
Antenna
LED Armed Indication
Shows if the Alarm System is armed or disarmed.
LED Zone Indication
Shows the status of the sensors in that zone or the status when programming.
Power LED
Steady green is normal and flashing green indicates low backup battery status.
1. Push the both sides in and open the cover of the Door/Window Sensor to insert an AAA Battery.
4. Insert Batteries in the Sensors
8. Security Keypad Overview
NOTE: The backlight will turn on when pressing the buttons. The factory default Pin is 0,0,0,0.
3. Undo the screw on the bottom side of the Security Keypad to remove the back plate and insert an AAA Battery.
5. Testing the Door/Window Sensor
1. Slide the switch at the back of the Main Console to alert mode.
2. Activate the Sensor by separating the magnetic contact of the sensor.
4. Move the magnetic contact back to the sensor and the alert sound will stop.
3. The Main Console will continue beeping and the Zone LED will flash if the door is open.
3. The main console will beep continuously and flash the Zone 1 LED if the door is open.
6. Testing Motion Sensor
* As an energy saving feature, the motion sensor will not be triggered again unless there is no motion detected for 6 seconds. In this case, the red LED will only flash once indicating the motion is detected, but no signal is sent.
1. Slide the switch at the back of the Main Console to alert mode.
2. Move in front of the motion sensor to trigger the sensor. The red LED on the sensor will flash multiple times.
3. The Main Console will continue beeping and the Zone 2 LED will flash if a motion is detected.
4. The Main Console will stop beeping and flashing the LED after 15 seconds.
LED
10. Install the Security Keypad
Place the sensor in the appropriate location:
Mount the Door/Window Sensor on your door or window
with double sided tape.
11. Install the Door/Window Sensor
Back Plate
1. Undo the screw on the bottom of the Keypad and remove the back plate.
Screw
LED
NOTE: The Door/Window Sensors are factory preset in Zone 1.
NOTE: The Motion Sensors are factory preset in Zone 2.
9. Change the Passcode of the Security Keypad
1. Input current PIN [factory default 0 0 0 0] and press button.
2. Input the new PIN number followed by button.
3. Input the new PIN again and press button.
NOTE: The factory default passcode is 0,0,0,0. The passcode can be 2-8 digits long and with a combination of buttons from 0-6.
If the Keypad emits 2 beep, your pin has been successfully changed. If it emits a long error beep, start from step 1 again.
2. Mount the backplate with the included Screws.
3. Attach the Keypad on the back plate and tighten the screw on the bottom of the Keypad.
Back Plate
Page 2
When chime mode is enabled
and your Skylink Alarm System
is disarmed, the Main Console
will beep every time a sensor
gets triggered.
When alert mode is enabled
and your Skylink Alarm System
is disarmed, the Main Console will
beep continously when a window/
door is opened or motion is detected
until the sensor is deactivated.
Chime Mode Alert Mode
14. Enable Chime or Alert Mode
23. Warranty / Customer Service20. Sensor Failure/Battery Indication 21. FAQ
This product is guaranteed to be free of defects in materials and workmanship for 1 year from the date of purchase. If this product is defective, call 1-800-304-1187 for repair or replacement parts. Guarantee does not include normal wear and tear or batteries.
If you have any questions, problems or missing parts, please call:
Skylink Customer Support
1-800-304-1187
9:00am – 5:00pm EST, Monday-Friday.
Or e-mail us at support@skylinkhome.com
www.skylinkhome.com
P/N:101Y186
If the signal is lost between the sensor and the Main Console, or if the battery in the sensor is low, the zone LED light will start blinking fast.
Take the following steps to troubleshoot the problem:
1. Check if the sensor is located where it should be, and whether there is any physical damage to the sensor.
2. If the failed sensor is not physically damaged, try to activate the sensor and see if the Main Console reacts to the activation.
3. If not, try to remove the sensor from its location, and bring it closer to Main Console and then activate the sensor. It is possible that the sensor is installed too far from the Main Console and it cannot establish a steady communication with the Main Console. If this is the case, please install the sensor closer to the Main Console.
4. Replace the battery of the sensor in that zone if the Main Console does not respond even when the sensor is near the Main Console.
NOTE: If you have multiple sensors in a zone, you may test the function of each sensor to identify which sensor is having a problem.
1. Slide the switch at the back of the Main Console to enable Chime or Alert Mode.
15. Alert Notication
The motion sensor can be mounted with a double
sided tape or screws in a corner, straight wall, ceiling or
stand freely by itself.
22. Erasing the Sensors/Remote from the Main Console
1. Remove the power adapter from the Main Console.
2. Press and hold the Learn Button and plug in the power adapter back in the Main Console.
3. Release the learn button when the red LED are flashing on the Main Console.
4. You have successfully erased all sensors and remotes from the Main Console.
NOTE: To erase any sensors or remote from the Main Console, you need reset the Main Console and learn the sensors/remotes you wish to keep.
LEDAC Adapter
Learn Button
Arm Home
Arm Away
13. Operation of Alarm System
1. Arm your alarm system by entering your PIN number followed by the “Arm Home” or “Arm Away” button on the Security Keypad.
2. When a sensor get triggered, the main console will sound a siren and the corresponding zone LED will flash for 3 minutes.
3. Enter the PIN number and press the “Disarm Button” on the Security Keypad to deactivate the alarm system.
12. Install the Motion Sensor
Place the sensor in the appropriate location:
ZONE 1 SENSORS - 1 Beep , Pause , 1 Beep , Pause ... etc.
ZONE 2 SENSORS - 2 Beep , Pause , 2 Beep , Pause ... etc.
ZONE 3 SENSORS - 3 Beep , Pause , 3 Beep , Pause ... etc.
ZONE 4 SENSORS - 4 Beep , Pause , 4 Beep , Pause ... etc.
When the Alert Mode is activated, you can identify the zone number by the number of beeps.
The beeping will continue until the sensor is deactivated. When the Main Console receives a signal from the motion sensor, the Main Console will beep and the LED will flash on the corresponding zone for 15 seconds.
Press the MUTE button if you want to temporarily disable the beeping sound.
Disarm
17. Program W/D Sensor to Main Console
1. Press and hold the “Learn” button for 3 seconds, until the Zone 1 red LED flash.
2. Zone 1 is selected. Press the learn button to select the Zone you want to program the sensor.
3. Activate the Sensor by separating the magnetic contact of the sensor.
4. Once the sensor is programmed, the Main Console will beep once and the corresponding zone red LED will be off.
18. Program Motion Sensor to Main Console
1. Press and hold the “Learn” button for 3 seconds, until the Zone 1 red LED flash.
2. Zone 1 is selected. Press the learn button to select the Zone you want to program the sensor.
3. Open the Motion Sensor cover with a coin and press the learn button.
4. Once the sensor is programmed, the Main Console will beep once and the corresponding zone red LED will be off.
16. Program Security Remote/Keypad Console
1. Press and hold the “Learn” button for 3 seconds, until the Zone 1 LED is flash.
3.
Once the Security Keychain Remote or Keypad Console is programmed, the Main Console will beep once and the corresponding zone LED will be off.
2. Press any button to program the Security Keychain Remote or enter the PIN number followed by the “Disarm Button” to program the Security Keypad Console.
NOTE: The Keychain Remote must be programmed in Zone 1. You can program up to 4 Remotes or Keypads with the Main Console.
NOTE: You can program up to 4 sensors in each Zone.
NOTE: You can program up to 4 sensors in each Zone.
19. Zone Settings
Refer to the chart below for the 2 zone operation modes. The unit is currently set at Default Zone Setting Mode.
Change between Default Zone and All Alert Zone Mode:
1. Power up the Main Console.
2. Press and hold the “Learn” and “Mute” button simultaneously for 5 seconds, until you hear the beep.
3. If you hear one beep, you are in “All Alert Zone Setting” and if you hear 2 beeps, you are in “Default Zone Setting”.
4. Release both button.
Zone Setting
Default Zone SettingZone
Zone 1 & 2
Special Zone Setting Suggestion Application
Zone 3
Zone 4
Alert when disarmed, Alarm when armed.
Alert when disarmed,
Alarm when armed.
Alert when disarmed,
Alarm when armed.
Alert when disarmed,
Alarm when armed.
No alert when disarmed,
but will alarm when armed.
Alert Only, No Alarm.
For outdoor sensor.
Indoor motion sensor in
a high traffice area.
Most sensor, except for sensors in outdoor or high traffic area.
Repeat the above steps to change between 2 operation modes.
- You must program the sensor or keypad to zone 1 of the main unit before they can work together.
- Ensure to input the correct password on the Keypad.
- Ensure to input the correct password if enable the password feature in keychain remote.
The Main Console does not respond to the sensor, keychain remote or Keypad Control?
- You must erase all the sensors/remotes in that zone and then program the remote you want to keep.
Can I erase just one sensor or remote from a zone?
- You need to test each remote/keypad/sensor individually.
I have multiple remotes in a zone and the zone LED keep flashing that is a remote failure, how do I know which sensor/remote is having the problem?
- It is recommended to power up the control panel with AC adapter. Install batteries to the Control Panel so it can continue to operate during power failure.
Can I only use battery to power up the Control Panel?
- When the backlit is dimmer and if you have to enter the Pin multiple times to arm/disarm the system, it is time to replace the battery.
When do I need to change the battery on the Keypad?
- Please contact Skylink customer support.
I forget the password on the Keypad, how can I reset it?
Loading...