XM-01
Electronic Sphygmomanometer
Operating Manual

Introduction
Thank you for buying a XM-01Automatic Electronic Blood Pressure Monitor
. This device is an innovative networking product and must be used with a smart phone or a tablet
PC display terminal. Over the network you can check all the previous measured data.
This product needs to be used with an app, which supports Android 4.0 and IOS 6.0 and higher
versions. The app can be downloaded from: www.tcxy.com.cn.
Before using this device, please read the manual carefully and pay attention to all the instructions
so as to use the product correctly.
For detailed information about the blood pressure readings obtained with this device, please
consult a professional doctor.

Purposes of the Product
The XM-01Automatic Electronic Blood Pressure Monitor is used to measure adults' systolic
pressure, diastolic pressure and pulse rate with the oscillometric method, and the data it
produces are only an aid to diagnosis.
Description of Symbols
Instructions
1. To facilitate comparison blood pressure should be measured at the same time each day.
2. This device is suitable for measuring adults' systolic pressure, diastolic pressure and pulse rate
with the oscillometric method, and the data it produces are only an aid to diagnosis.
3. Newborns, pregnant women and sufferers from aura epilepsy should not use this
sphygmomanometer.
4. Before each measurement remain at rest for 15 minutes. If the device is used to measure the
same person repeatedly, preserve an interval of 5 minutes between each measurement.
5. Do not eat, smoke, drink or undertake any vigorous activity for 30 minutes before measurement.
6. When measuring it with your body relaxed and at rest. Keep your hand as level as possible, with

your palm up and wristband and heart at the same height. Remain relaxed and breathe gently.
7. Take care that the wristband is attached correctly. Bare your wrist and do not wrap the wristband
round too tight.
8. Patients with serious blood circulation disorders or blood diseases should use the device under
the direction of a doctor.
9. In the event of common arrhythmia (e.g. atrial premature beats, ventricular premature beats,
atrial fibrillation etc.) the measurements may not be correct or blood pressure may not be
measurable. In such cases do not use the device to measure your blood pressure.
10. Measurements you make yourself are only for personal reference, and should not replace
medical examination. You can consult your doctor about the measured data, but you should not
use them as the basis for any medical decision.
11. Do not dismantle, repair or change the sphygmomanometer's main body or wristband, otherwise
the results may be affected.
12. This device is only suitable for the purposes specified in the operating manual, and the
manufacturer is not responsible for any damage caused by violating regulations or misusing the
device.

Caution
1. When the air pocket is pressurized excessively, it may cause damage to your arm. If this
situation occurs, loosen the wristband immediately.
2. Overcharging for a long time may result in damage to the hardware and batteries. Power
off promptly when charging is complete.

Federal Communication Commission Interference Statement
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
2. Changes or modifications made to this equipment not expressly approved by Sky Innovation
Technology (Shanghai) Limited may void the FCC authorization to operate this equipment.
3. Radio frequency radiation exposure Information:
The radiated output power of the device is far below the FCC radio frequency exposure limits.
Nevertheless, the device shall be used in such a manner that the potential for human contact
during normal operation is minimized.