SK Telesys SKSN I15 CO Users manual

i-DEN REPEATER
R
i-DEN RF
EPEATE
USER MANUAL
Version 1.0
2007
SK Telesys Co., LTD Proprietary Document 1/46
i-DEN REPEATER
Lists of Contents
1. OVERVIEW.................................................................................................................3
2. COMPONENTS...........................................................................................................3
2.1 PACKING LIST ......................................................................................................3
2.2 SYSTEM QUICK VIEW .........................................................................................3
2.3 WARNING AND HAZARDS ...................................................................................3
3. FEATURES AND SPECIFICATION OF SYSTEM.......................................................3
3.1 ELECTRICAL SPECIFICATION ................................................................................3
3.2 MECHANICAL SPECIFICATION...............................................................................3
3.3 ENVIRONMENT SPECIFICATION............................................................................3
3.4 FREQUENCY USED .................................................................................................3
4. SYSTEM BLOCK DIAGRAM......................................................................................3
4.1 BLOCK DIAGRAM.................................................................................................3
4.2 BLOCK DIAGRAM DESCRIPTION .......................................................................3
5. SYSTEM OVERVIEW..................................................................................................3
5.1 CONSTRUCTION AND FEATURES OF SYSTEM ................................................3
5.1.1 PSU (POWER SUPPLY UNIT) ..............................................................................3
5.1.2 CONTROLLER ......................................................................................................3
5.1.3 UP / DOWN CONVERTER....................................................................................3
5.1.4 MULTIPLEXER ......................................................................................................3
SK Telesys Co., LTD Proprietary Document 2/46
i-DEN REPEATER
5.1.5 PAU(POWER AMPLIFIER UNIT)...........................................................................3
5.1.6 CABINET ...............................................................................................................3
5.2 ADDITIONAL FUNCTIONS ...................................................................................3
5.2.1 ALC FUNCTION ....................................................................................................3
5.2.2 SHUTDOWN FUNCTION ......................................................................................3
5.2.3 OSCILLATION CHECK FUNCTION ......................................................................3
5.2.4 OSCILLATION SHUTDOWN FUNCTION..............................................................3
6. SYSTEM INSTALLATION GUIDE...............................................................................3
7. WEB GUI INSTALLATION GUIDE..............................................................................3
7.1 PROGRAM SETUP ...............................................................................................3
7.2 WEB GUI CONNECTION ......................................................................................3
7.3 MONITOR/CONTROL OF WEB GUI STATE .........................................................3
7.3.1 ACCOUNT.............................................................................................................3
7.3.2 USER REGISTRATION .........................................................................................3
7.3.3 DELETION AND CHANGE OF USER ...................................................................3
7.3.4 ALARM HISTORY..................................................................................................3
7.3.5 CONFIG.................................................................................................................3
7.3.6 UP LOAD...............................................................................................................3
8. MAINTENANCE GUIDE..............................................................................................3
8.1 CONFIRMATION OF SYSTEM COMPONENTS ...................................................3
8.2 CAUTIONS ON SYSTEM INSTALLATION ............................................................3
SK Telesys Co., LTD Proprietary Document 3/46
i-DEN REPEATER
9. SYSTEM SET UP AND INSPECTION ........................................................................3
9.1 ITEMS TO BE CHECKED FOR OPENING............................................................3
9.2 ITEMS TO BE CHECK AFTER OPENING.............................................................3
9.3 FAILURE AND INSPECTION.................................................................................3
9.3.1 INSPECTION OF REPEATER...............................................................................3
9.3.2 FACILITY INSPECTION ........................................................................................3
10 . WARRANTY AND REPAIR POLICY........................................................................3
10.1 GENERAL WARRANTY ........................................................................................3
10.2 LIMITATIONS OF WARRANTY .............................................................................3
10.3 LIMITATION OF DAMAGES ..................................................................................3
10.4 NO CONSEQUENTIAL DAMAGES.......................................................................3
10.5 ADDITIONAL LIMITATION ON WARRANTY .........................................................3
10.6 RETURN MATERIAL AUTHORIZATION (RMA) ....................................................3
CONTACT INFORMATION........................................................................................3
Information in this document is subject to change without notice. SK Telesys Co., LTD. All rights reserved.
SK Telesys Co., LTD Proprietary Document 4/46
i-DEN REPEATER
- Lists of Figures -
< Fig. 1 > Configuration of iDEN Network ................................................................................. 3
< Fig. 2 > Components of iDEN Repeater................................................................................. 3
< Fig. 3 > Front & Back View of iDEN Repeater........................................................................ 3
< Fig. 4 > Side View of iDEN Repeater ..................................................................................... 3
< Fig. 5 > Bottom View of iDEN Repeater................................................................................. 3
< Fig. 6 > iDEN Frequency........................................................................................................ 3
< Fig. 7 > Features of iDEN Carrier........................................................................................... 3
< Fig. 8 > Block Diagram........................................................................................................... 3
< Fig. 9 > Internal Construction of iDEN Repeater.................................................................... 3
< Fig. 10 > Bottom View of iDEN RF Repeater ......................................................................... 3
< Fig. 11 > Latch Structure ........................................................................................................ 3
< Fig. 12 > Hinge Functions ...................................................................................................... 3
< Fig. 13 > Swing Handle Function ........................................................................................... 3
< Fig. 14 > Guide for Wrench Prevention.................................................................................. 3
< Fig. 15 > Mounting Sequence of the iDEN Repeater ............................................................. 3
< Fig. 16 > Local Area Connection Properties........................................................................... 3
< Fig. 17 > Internet Protocol(TCP/IP) Properties ...................................................................... 3
< Fig. 18 > Local Area Connection State-1................................................................................ 3
< Fig. 19 > Local Area Connection State-2................................................................................ 3
< Fig. 20 > Web GUI Initial Screen............................................................................................ 3
< Fig. 21 > Monitoring Screen of iDEN Repeater State............................................................. 3
< Fig. 22 > Control Screen of iDEN Repeater State.................................................................. 3
< Fig. 23 > Input Range Excess Message ................................................................................ 3
< Fig. 24 > Set Up Completion Message .................................................................................. 3
< Fig. 25 > Polling Time............................................................................................................. 3
< Fig. 26 > Function Button ....................................................................................................... 3
< Fig. 27 > Logout ..................................................................................................................... 3
< Fig. 28 > Account Page.......................................................................................................... 3
< Fig. 29 > User Registration .................................................................................................... 3
< Fig. 30 > Deletion and Change of User.................................................................................. 3
< Fig. 31 > Alarm History........................................................................................................... 3
SK Telesys Co., LTD Proprietary Document 5/46
i-DEN REPEATER
< Fig. 32 > Construction Information of System ........................................................................ 3
< Fig. 33 > Upload Page ........................................................................................................... 3
< Fig. 34 > File Selection........................................................................................................... 3
< Fig. 35 >Upload Arrangement ................................................................................................ 3
< Fig. 36 > Key Value Error ....................................................................................................... 3
< Fig. 37 > Upload Completion.................................................................................................. 3
- Lists of Tables -
<Table 1 > Packing List ............................................................................................................. 3
<Table 2 > System Features ..................................................................................................... 3
<Table 3 > Figure and Function................................................................................................. 3
< Table 4 > Environmental specifications .................................................................................. 3
< Table 5 > iDEN Frequency ..................................................................................................... 3
SK Telesys Co., LTD Proprietary Document 6/46
i-DEN REPEATER
1. Overview
iDEN (Integrated Digital Enhanced Network) repeater is an OTA type of repeater based on RF
signal boosting to enhance in-building coverage using frequency bandwidths operated by iDEN
system.
iDEN repeater amplifies received EBTS(Enhanced Base Transceiver System) OTA signal and
relays it to fill an in-building coverage. The amplified signal can be distributed by repeaters
installed in various poor coverage where telecommunication service can not be provided such
as buildings, homes and in-building parking lots..
It is designed to be flexibly applicable for every frequency in iDEN spectrum bandwidth with
excellent selectivity capabilities of frequency in broad range for Down Link and Up Link service
through one UP/DOWN Converter and minimizes interference of other signals. For stable
service of repeater installed in the field iDEN (Integrated Digital Enhanced Network) repeater
controller has two management functions; the local repeater management function to
continuously manage and control the repeater and remote repeater management function to
remotely inspect and control through intensive inspection system.
iDEN (Integrated Digital Enhanced Network) repeater is interlocked with iDEN repeater
intensive inspection system using modem.
The basic structure of iDEN repeater is supported by one input Port and one output Port. The
inner section of repeater composes of One-Module of DL(Down Link) Converter and UL(Up
Link) Converter, PSU(Power Supply Unit), Multiplexer, Controller, and PAU(Power Amplifier
Unit) in order to achieve optimized size and high effectiveness.
All modules except PAU are commonly used for cost effective operation. For instance
replacement of PAU enables change of repeater output.
SK Telesys Co., LTD Proprietary Document 7/46
i-DEN REPEATER
< Fig. 1 > Configuration of iDEN Network
SK Telesys Co., LTD Proprietary Document 8/46
i-DEN REPEATER
2. Components
2.1 Packing List
No Description quantity Remark
1 iDEN Repeater 1
2 AC Power Cable 1
3 Ground Cable 1
4 Bolts to fix the holder 4
5 Key 2
6 CD 1 Manual
<Table 1 > Packing List
< Fig. 2 > Components of iDEN Repeater
SK Telesys Co., LTD Proprietary Document 9/46
i-DEN REPEATER
2.2 System Quick View
< Fig. 3 > Front & Back View of iDEN Repeater
< Fig. 4 > Side View of iDEN Repeater
SK Telesys Co., LTD Proprietary Document 10/46
i-DEN REPEATER
< Fig. 5 > Bottom View of iDEN Repeater
2.3 Warning and Hazards
Danger of electric shock! Switch off while( it is ) maintained and inspected!
Working with the repeater while in operation, may expose the technician to RF electromagnetic fields that exceed FCC rules for human exposure. Visit the FCC website at www.fcc.gov/oet/rfsafety about the effects of exposure to RF electromagnetic fields.
to learn more
SK Telesys Co., LTD Proprietary Document 11/46
i-DEN REPEATER
RF EXPOSURE & ANTENNA PLACEMENT
Actual separation distance is determined upon gain of antenna used. Please maintain a minimum safe distance of at least 20 cm while operating near the donor and the service antennas. Also, the donor antenna needs to be mounted outdoors on a permanent structure.
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at own expense.
Warning!
This equipment generates or uses radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.
SK Telesys Co., LTD Proprietary Document 12/46
i-DEN REPEATER
3. Features and Specification
3.1 Electrical Specification
Item Specification Remark
Downlink : 851~874MHz
Frequency
Range
800MHz
900MHz
(Ability to switch 862~869 MHz)
Uplink : 806~824MHz
(Ability to switch 817~824 MHz)
Downlink : 935~940MHz
Uplink : 896~901MHz
25kHz Step
25kHz Step
Amplifier Gain /
Output Powe
Input Level
Gain Control Range
Downlink
Adjacent
Power
r per Channel
Ripple 2.5 dB p-p
Roll offs Over 65dBc @Band Edge± 500 KHz
1 carrier
8carriers
65dB / 15dBm iDEN(65/15) 65dB / 25dBm iDEN(65/25) 80dB / 30dBm iDEN(80/30)
-25 ~ -50dBm / Total iDEN(65/15)
-15 ~ -40dBm / Total iDEN(65/25)
-20 ~ -50dBm / Total iDEN(80/30)
25 dB(1dB/Step±0.5dB or less) iDEN(65/15),(65/25)
30 dB(1dB/Step±0.5dB or less iDEN(80/30)
25KHz : 50dBc 50KHz : 55dBc
500KHz : 55dBc
1MHz, 2MHz : 55dBc
25KHz : 47dBc 50KHz : 52dBc
500KHz : 52dBc
1MHz, 2MHz : 52dBc
Out of band paging
carrier rejection
900MHz Inter modulation 1870~1880MHz/-105dBm 900MHz only
Spurious RF Emission -13dBm or less
Propagation Delay 8us or less
Noise Figure
VSWR 1.5 : 1
Input/output connector N-Type (Female)
929~932MHz(3MHz),
940~941MHz(1MHz)
Input : -15dBm ~ +5dBm
5dB or less @Gain 65dB(Uplink)
12dB or less @Gain 40dB(Uplink)
SK Telesys Co., LTD Proprietary Document 13/46
i-DEN REPEATER
Input/output impedance 50
Power 108 ~ 127 VAC, 60Hz
<Table 2 > System Features
3.2 Mechanical Specification
Item Specification
Cabinet Indoor Type
RF Connector Type(IN/OUT) N-Type Female
Dimension
(H*W*D)
Weight
<Table 3 > Figure and Function
390*326*190 mm iDEN(65/15) 390*326*210 mm iDEN(65/25) 390*326*240 mm iDEN(80/30)
18.5Kg iDEN(65/15)
20.0Kg iDEN(65/25)
21.5Kg iDEN(80/30)
Option -40 to -60VDC
20 to 30 VDC
3.3 Environmental Specification
Item Specification Remark
Working temperature/
working humidity
Power 108 ~ 127 VAC, 60Hz
< Table 4 > Environmental specifications
-10 ~ 50 / 5 % ~ 95%℃℃
Temperature and humidity
around cabinets
Option -40 to -60VDC
20 to 30 VDC
SK Telesys Co., LTD Proprietary Document 14/46
Loading...
+ 32 hidden pages