Skov DOL 100 Technical User Manual

DOL 100 digital box
Technical User Guide
604336 • 2018-08-07
English For other language variants of this document we refer to: Español Para otras variantes del idioma de este documento, visite: Français Pour les versions dans d'autres langues de ce document veuillez consulter:
http://docs.skov.com/1174
DOL 100 digital box
Technical User Guide 3
Product and Documentation Changes
We reserve the right to change this manual and the product described herein without further notice. In case of doubt, please contact us.
The last revision date appears on the front and back pages.
Note
• All rights reserved SKOV A/S. No part of this manual may be reproduced in any manner whatsoever without the expressed written permission of SKOV A/S.
• Every effort has been made to ensure the accuracy of the information contained in this manual. Should any mistakes or imprecise information be found in spite of this, SKOV A/S would appreciate being notified thereof.
• Irrespective of the above, SKOV A/S shall not accept any liability with regard to loss or damage caused or alleged to be caused by reliance on any information contained herein.
• Copyright by SKOV A/S.
DOL 100 digital box
Technical User Guide
1 Product description........................................................................................................................................5
2 Product survey ...............................................................................................................................................6
2.1 Accessories.................................................................................................................................. 6
3 Mounting Guide ..............................................................................................................................................7
3.1 Recommended tools .................................................................................................................... 7
3.2 Mounting on Wall ......................................................................................................................... 8
4 Installation Guide ...........................................................................................................................................9
4.1 Electrical connection .................................................................................................................... 9
4.2 Cable routing................................................................................................................................ 9
4.3 Nano CAN bus coupler .............................................................................................................. 10
4.3.1 LED indication on the CAN bus coupler..................................................................................... 11
4.4 Nano I/O module digital 8l.......................................................................................................... 12
4.5 Connection in DOL 100.............................................................................................................. 13
4.6 Setting up the DOL 100 in the controller....................................................................................14
4.7 Cable Plan .................................................................................................................................15
4.8 Circuit Diagram .......................................................................................................................... 16
4.8.1 DOL 100 and water meter.......................................................................................................... 16
4.8.2 DOL 100 and DOL 192 12 ......................................................................................................... 17
4.8.3 DOL 100 and DOL 192 20 ......................................................................................................... 17
4.8.4 DOL 100 and DOL 192 30-75 .................................................................................................... 18
4.8.5 DOL 100 and capacitive sensor.................................................................................................18
5 Cleaning ........................................................................................................................................................19
6 Troubleshooting guide.................................................................................................................................20
7 Technical Data ..............................................................................................................................................21
DOL 100 digital box
Technical User Guide 5
1 Product description
DOL 100 Digital 8I/16I box is used to connect water meter, egg counter, and capacitive sensor to the CAN bus communication and thereby avoid numerous cables to the climate controller. The DOL 100 converts the signal into digital signals and transmits them to the controller using CAN bus commu­nication.
• DA 100 digital is available in two variants:
• Connect up to 8 items to the DOL 100 digital 8I box.
• Connect up to 16 items to the DOL 100 digital 16l box.
(C)
(B)
(A)
(D)
(E)
(A) Controller
(B) Connect up to 16 items to the DOL 100
digital 8l/16l box.
(C) Water meter
(D) Egg counter
(E) Capacitive sensor
DOL 100 digital box
6 Technical User Guide
2 Product survey
130183 DOL 100 digital 8l box
130184 DOL 100 digital 16l box
External I/O box for connection of of water meter, egg counter or capacitive sensor.
The DOL 100 converts the signal into digital signals and transmits them to the controller using CAN bus communication.
Standard software / hardware of the DOL 530/630 series supports 13 I/O modules in total. DOL 100 is counted in as one module.
0-24 V inputs terminals: 8 or 16.
Is used with the data network module (132244) and a CAN bus cable (130121-130128)
2.1 Accessories
132244 Data network module w. CAN bus
Always use the data network module when using external CAN bus com­munication.
One for each controller.
130121 CAN bus cable 50 m 130125 CAN bus cable 100 m 130126 CAN bus cable 250 m 130122 CAN bus cable 500 m
For indoor use.
Use these cables in connection with external units using the CAN bus com­munication.
130123 CAN bus cable UV 50 m 130127 CAN bus cable UV 100 m 130128 CAN bus cable UV 250 m 130124 CAN bus cable UV 500 m
For outdoor use.
Use these cables for external units that apply CAN bus communication and for extending silo load cell cables.
DOL 100 digital box
Technical User Guide 7
3 Mounting Guide
3.1 Recommended tools
Below follows a list of tools recommended for installation of the DOL 100.
Item Description
Cordless drill
Screwdriver bits
Utility knife
Multimeter
Tape measure
Side cutter
Pointed pliers
Ladder
Screwdriver
Spirit level
DOL 100 digital box
8 Technical User Guide
3.2 Mounting on Wall
Mount the DOL 100 digital box on the wall us­ing four screws.
DOL 100 digital box
Technical User Guide 9
4 Installation Guide
4.1 Electrical connection
Installation, servicing and troubleshooting of all electrical equipment must be carried out by quali­fied personnel in compliance with the applicable national and international standard EN 60204-1 and any other EU standards that are applicable in Europe.
The installation of a power supply isolator is required for each motor and power supply to facilitate voltage-free work on the electrical equipment. SKOV does not supply the power supply isolator.
4.2 Cable routing
To prevent water from running into the DOL 100 via cables and screwed connections, run the cables so that water does not gather around the cable in the gasket of the screwed connec­tion.
DOL 100 digital box
10 Technical User Guide
4.3 Nano CAN bus coupler
(A)
(A)
(A)
(A)
(B)
(D)
(C)
(E)
Item Function Description
(A)
Terminals Terminals to I/O modules
(B)
N1 GND N2 +24V N3 CAN_H N4 CAN_L N5 SHIELD N6 CAN GND
0 V Power supply +24 VDC (max. 2.1 A) CAN high (brown CAN bus) CAN low (white CAN bus) Shield (braided shield CAN bus) (green CAN bus) The terminal can also be used as a looped terminal strip to the next box.
(C)
CAN ID CAN bus address (CAN ID). The address switches are used for setting the CAN ID.
The DOL 100 must have a specific CAN ID for the controller to communicate with it. The address of the individual DOL 100 corresponds to the address in the controller in the menu Technical | Setup | Installation | I/O Modules | Additional I/O Modules
Address switches X10 is set to 5 in connection with DOL 100 water and 3 in con­nection with DOL 100 digital.
The address switches X01 are set to the displayed number or letter after the fig­ure 5 or 3 in the controller. If change of address, restart DOL 100 for the change to take effect.
(D)
TERM ON
Jumper is set to (ON).
(E)
TERM ON CAN bus termination. If DOL 100 is the last node in the CAN bus communication, the
jumper must be set to (ON) .
DOL 100 digital box
Technical User Guide 11
4.3.1 LED indication on the CAN bus coupler
(A)
(B)
(D)
(C)
(D)
Item Function LED col-
our
Description
(A)
24 V IN
Green
ON: 24 V DC power supply OK.
24 V Log ON: 24 V DC Internal OK.
24 V I/O ON: 24 V DC I/O fuse F1 OK.
(B)
Internal CAN bus RX Green ON: receiving data
Internal CAN bus TX Red ON: transmitting data
(C)
External CAN bus RX
Green ON: receiving data
External CAN bus TX
Red ON: transmitting data
(D)
CPU RUN Green FLASHES: OK.
OFF: not ready for operation
Operate Yellow States the CAN bus status
ON: operate OFF: pre-operate
CAN ERROR Red OFF: CAN bus OK.
FLASHES: CAN bus error.
ERROR Red General error
Boot mode All LED ON (CPU RUN, Operate, CAN ER-
ROR and ERROR
DOL 100 digital box
12 Technical User Guide
4.4 Nano I/O module digital 8l
Nano I/O module # 1
Nano I/O module # 2
(A)
(A)
(B)
(G)
(F)
(E)
(E)
(D)
(C)
(C)
(D)
Item Function Description
(A)
TERM CAN bus termination.
The jumper is mounted on the I/O module furthest away from the CAN bus coupler.
(B)
CAN ID
Jumper setting on I/O module # 1.
Jumper setting on I/O module # 2.
(C)
Terminals +24 V DC N11 -N28. Max. 1.9 A gathered on the outputs N11-N28
(D)
Terminals Signal input N11 -N28
(E)
Terminals GND N11 -N28
(F)
High / Low
Jumper Low (NPN)
(G)
LED 1-8 Green = Input 1-8 active
DOL 100 digital box
Technical User Guide 13
4.5 Connection in DOL 100
24 V DC power supply
CAN bus connection, see dimensions below. CAN_H = brown CAN_L = white CAN GND = green.
Strip the cable so the shield can be connected to the DOL 100 when mounting in the connection terminal.
As illustrated by the picture, the connection terminal can also be used as a looped terminal strip to the next box.
DOL 100 digital box
14 Technical User Guide
4.6 Setting up the DOL 100 in the controller
Make sure the CAN protocol is set to CANopen.
Technical | Setup | Installation | I/O Modules | CAN protocol
Select number of DOL 100. The DOL 100 8I box supports up to 8 water meters, egg counters or capacitive sensor. The DOL 100 16I box supports up to 16 water meters, egg counters or capacitive sensors. The software supports up to 13 I/O modules. DOL 100 is counted in as one module.
Technical | Setup | Installation | I/O Modules | Extra I/O modules
Here you see the CAN bus address (CAN ID) and if it is connected.
Select number of water meters
Technical | Setup | Installation | Production | Water meter
Select number of egg counters
Technical | Setup | Installation | Production | Egg counter | Egg counters installed
The DOL 539/535 installation menu specifies which connection ter­minal numbers and in which DOL 100 box the water water meters must be connected. For correct connection of the items, see the menu Technical | Setup |
Show connections
I/O#1 N13 = DOL 100 box no. 1, connection terminal N13.
I/O#3 N28 = DOL 100 box no. 3, connection terminal N28.
DOL 100 digital box
Technical User Guide 15
4.7 Cable Plan
Power supply
Power supply
CAN bus cable
max. 400 m
(D)
(A)
(B)
(C)
(E)
(F)
(G)
(A) Power supply to the controller, two-wire cable including earthing contact.
(B) Max. 400 m CAN bus communication cable between the DOL 100 digital 8l/16l box and the controller. The
CAN bus cable connecting all units of the system may not exceed 400 m.
(C) Power supply to the DOL 100 digital 8I/16I box, two-wire + earthing contact.
(D) Two-wire control cable to the water meter.
(E) Three-wire power supply and control cable to DOL 192 12-20 egg counter.
(F) Two-wire control cable to DOL 192 30-75 egg counter.
(G) Four-wire power supply and control cable to capacitive sensor.
DOL 100 digital box
16 Technical User Guide
4.8 Circuit Diagram
4.8.1 DOL 100 and water meter
DOL 100 digital box
Technical User Guide 17
4.8.2 DOL 100 and DOL 192 12
4.8.3 DOL 100 and DOL 192 20
DOL 100 digital box
18 Technical User Guide
4.8.4 DOL 100 and DOL 192 30-75
4.8.5 DOL 100 and capacitive sensor
DOL 100 digital box
Technical User Guide 19
5 Cleaning
The DOL 100 box is maintenance-free but should be kept free of litter and dirt.
Clean the product with a cloth that has been wrung out almost dry in water and avoid using:
• high-pressure cleaner
• solvents
• corrosive/caustic agents
DOL 100 digital box
20 Technical User Guide
6 Troubleshooting guide
Error
No light LED on the CAN bus coupler.
Check the 24 V DC power supply to the DOL 100.
Check that you have installed the DOL 100 digital 8I/16I box and water meter/egg counter/capacitive sensor in the controller, see section Setting
up the DOL 100 in the controller [}14]
No CAN bus communication con­nectivity with the DOL 100 digital 8l/16l box.
Check resistance between CAN H and CAN L; the resistance must be approximately 60 ohms.
If the resistance is > 100 ohms, a termination is missing.
If the resistance is< 45 ohms, there are too many terminations.
DOL 100 digital box
Technical User Guide 21
7 Technical Data
Electrical Setup
Operating voltage
V AC 90 – 264
Max. power
W 75
Max. power consumption
A 0.7
CAN bus
Protocol
CANopen in accordance with CiA301 and CiA401
Baud rate (fast)
Kbd 125
Max. cable length
m 400
Input terminals 8 digital
Low V < 6
High V > 12
Input impedance kOhm 24
Max. input frequency Hz 500
Puls width min. ms 1
Outputs for power supply to egg counter and capacitive sensor
Voltage V dc 24
Max. current A 1.9
Mechanical
Material
ABS
Cable knock-out holes
20 x M25 For metrical cable glands
Environment
Temperature, operation
°C 0 – 50
Protection class
IP 54
Shipment
Dimensions (H x W x D)
mm 381x400x170
Dimensions crated H x W x D
mm 395x415x206
Weight
g 3520
Shipping weight
g 4560
604336 • 2018-08-07 • en • Made in Denmark
SKOV A/S • Hedelund 4 • Glyngøre • DK-7870 Roslev
Tel. +45 72 17 55 55 • www.skov.com • E-mail: skov@skov.dk