Skope CONSORT PLC075TI, CONSORT PLC125TI, CONSORT PLC150TI, CONSORT PLC200TI Operating Instructions Manual

PLC075TI, PLC125TI, PLC150TI, PLC200TI
SKOPE CONSORT Convection Panel Heaters
Installation and Operating Instructions
MAN0981 Rev. 2.0 March 2010
PLC075TI, PLC125TI, PLC150TI, PLC200TI
SKOPE CONSORT Convection Panel Heaters
Safety Information
When using any electrical appliance, safety precautions should always be observed. Read these instructions carefully, and retain for future reference. For service, contact your nearest authorised service agent.
•When used by, or near, young children or infirm persons, close supervision is necessary. Young children should be supervised to ensure that they do not play with the appliance, nor touch anywhere near the outlet grille.
•Do NOT touch the outlet grille, as it is VERY hot.
•Do NOT use this appliance other than for its intended use.
•Do NOT cover the grilles or place any object or material up against the unit, as this may block entry or exhaust of airflow.
•Do NOT probe any opening to remove fluff. To ensure trouble-free performance it is recommended that on a regular basis the unit be isolated from the power supply and a vacuum cleaner used to remove dust and fluff from the inlet and outlet grilles.
•Do NOT allow the supply cord to come into contact with heated surfaces during operation.
•Use this appliance with the voltage specified on the rating label.
•Be very careful not to touch hot surfaces or moving parts.
•If the supply cord becomes damaged, it must be replaced by a SKOPE authorised service agent, or similarly qualified person, in order to avoid a hazard.
•Regulations require that electrical work be carried out by authorised persons. For your own safety and that of others, ensure this is done.
PLC075TI, PLC125TI, PLC150TI, PLC200TI
SKOPE CONSORT Convection Panel Heaters
Installation Regulations
This appliance MUST be installed in accordance with relevant wiring rules and regulations which cover installation of appliances and accessories in damp situations such as bathrooms, showers, laundries and other areas with fixed water containers (in Australia and New Zealand - AS/NZS 3000:2000 Wiring Rules).
IMPORTANT: The heater must not be located immediately below a socket outlet. A suitable disconnection device (acting in all active supplies) is required to be incorporated in the fixed supply wiring.
The heater must be mounted a minimum distance of:
•150mm from floor level
•400mmm below a fixture or ceiling
•300mm from adjacent walls
Installation Dimensions
Model A B C
PLC075TI 442mm 196mm 123mm PLC125TI 614mm 364mm 125mm PLC150TI 680mm 488mm 96mm PLC200TI 852mm 616mm 118mm
Figure 1: Installation dimensions
PLC075TI, PLC125TI, PLC150TI, PLC200TI
SKOPE CONSORT Convection Panel Heaters
Installation Instructions
The wall bracket supplied with the heater must be used when attaching heater to the wall. To attach heater to the wall:
1.Remove wall bracket from the heater, with the chains attached,
by removing the two securing screws from top of the rear panel.
2.Fix wall bracket to wall using the four fixing screw holes provided
(see Figure 1 for dimensions).
3.Locate heater onto both bottom lugs of the wall bracket.
4.Hinge heater upwards, and replace retaining screws with link
plates of chain attached, and move heater to upright position. The link plates should slide under the wall bracket retaining slot.
5.Tighten both retaining screws (see Figure 2 below).
Figure 2: Wall bracket
Wall bracket retaining slot
Heater
Retaining screw
Fixing screw
Chain link plate
Chain
Wall
bracket
PLC075TI, PLC125TI, PLC150TI, PLC200TI
SKOPE CONSORT Convection Panel Heaters
Operation
The controls are located behind a cover on the right hand end of the heater. When the appliance is connected to the mains supply the neon indicator on front of the heater should be illuminated. The operation of the heater is controlled by use of the following controls:
Heat Switches
The heat output is controlled by two switches located under the thermostat knob (see Figure 3 below). One switch depressed will give half the heater output, while both switches depressed will give full heat output.
Thermostat
The heater is fitted with a built­in thermostat to control the temperature level to which the room is heated. The thermostat adjustment knob is located on the right hand end and is numbered. Rotate the knob clockwise to a higher number to raise the room temperature. Once set it is unlikely to require to be touched again.
Frost Watch
The ‘Frost Watch’ function is intended to keep vacated areas above freezing level, so water pipes do not burst.
To set the heater to the Frost Watch mode, turn the thermostat control knob fully anti-clockwise until the frost symbol aligns with mark.
Figure 3: Control panel
Heat switches
24-hour timer dial
Thermostat knob
Selector switch
PLC075TI, PLC125TI, PLC150TI, PLC200TI
SKOPE CONSORT Convection Panel Heaters
24-Hour Timer
The heater must be connected to the mains supply in order for the timer to operate continuously.
Set the correct time on the timer by rotating the dial clockwise until the correct time is indicated on the 24-hour clock face.
Automatic Operation
Move the selector switch (immediately beneath the timer) to the auto position designated .
The 24-hour timer can be set to give any combination of On/Off intervals to a minimum of 15 minutes on. Select the 'On' time required by pressing the black segment (on the circumference of the timer) adjacent to the time required outwards. This will cause the heater to switch 'On' at the selected time for 15 minutes operation. Each additional segment pressed out will give a further 15 minutes of operation. In this way, select the length of time required for the unit to be 'On' and push out the number of 15-minute segments necessary to select the time period required.
The timer can be set to give as many 'On' periods as required during any 24-hour period.
This program will repeat itself every 24 hours until changed. This program may be overridden at any time by switching to manual operation.
Manual Operation
Move the selector switch, immediately beneath timer, to the manual position designated . The heater will now run continuously, controlled by the heat switches and thermostat setting.
7
PLC075TI, PLC125TI, PLC150TI, PLC200TI
SKOPE CONSORT Convection Panel Heaters
Thermal Operated Cut-Out
The appliance is fitted with an Electronic Safety Control (ES). This is a safety device, which switches the heater off if, for any reason, the appliance overheats. The ES control can only be re-set after the appliance has cooled down. In order to re-set the ES control, proceed as follows:
1.Switch off appliance and leave for approximately 5 minutes.
2.Switch appliance back on and ES control will re-set.
3.Ensure that the appliance is functioning correctly. If the ES
control operates again, the appliance should be checked by a competent electrician.
The heater carries a 'Do Not Cover' label to warn the user that if the appliance is covered, there is a risk of overheating.
CAUTION:
In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must NOT be supplied through an external timer.
If your heater does not work:
•Check that power is available to the heater. The neon indicator on front of the heater should be illuminated.
•Check that the thermal cut-out has not operated. If the cut-out has operated follow the re-set instructions above.
•Do not attempt to repair the heater.
Care
The heater is best wiped down with a damp cloth. Do not use any abrasive cleaners. Always disconnect the heater from the mains power before cleaning the heater. When cleaning the heater:
•Do NOT use any abrasive cleaners
•Do NOT touch the heater with wet hands, or in any way bring water into contact with the heater.
PLC075TI, PLC125TI, PLC150TI, PLC200TI
SKOPE CONSORT Convection Panel Heaters
Specifications
SKOPE Industries Limited reserve the right to alter specifications without notice.
Contact Addresses
Dimensions
Model: PLC075 PLC125TI PLC150TI PLC200TI Height: 430mm 430mm 430mm 430mm Width: 442mm 614mm 680mm 852mm Depth: 93mm (includes rear fixing bracket) Weight: 3.7 kg 4.9 kg 5.4 kg 6.5 kg
Electrical
Wattage: 675-750 W 1125-1250 W 1350-1500 W 1800-2000 W Supply: 230-240 Volts a.c. 50 Hz. Wiring: 1.8m flexible cord and plug. This appliance MUST be Earthed. Ingress Protection Rating: IPX4
New Zealand
SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone: 0800 947 5673 Fax: (03) 983 3896 Email: enquiry@skope.co.nz Website: www.skope.co.nz
Australia
SKOPE AUSTRALIA PTY LTD A.C.N. 000 384 270 PO Box 7543, Baulkham Hills B.C. NSW 2153, Australia Freephone: 1800 121 535 Freefax: 1800 121 533 Email: enquiry@skope.com.au Website: www.skope.com.au