Skimo Split 320B05,Split 320B06,Split Heater 320B51 Installation, User And Maintenance Manual

Société Nouvelle De Climatisation
274, chemin des Agriés – 31860 LABARTHE SUR LEZE
Tél. : 05 34 480 480 - Fax : 05 34 480 481
This document is the property of SNDC SAS – It can neither be reproduced, nor communicated without SNDC SAS's written authorization.
Version 3 – 30/06/15 810C37-EN-MANUTMAIN
EN
INSTALLATION, USER AND MAINTENANCE MANUAL
SKIMO SPLIT
EN
PART NUMBER : 320B05 – SKIMO SPLIT 12V
320B06 – SKIMO SPLIT 24V
EN
Read this manual carefully until you understand it before unpacking, installing or using the Skimo unit. Keep this manual for further reference.
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
2/22
The 2 years warranty only applies under normal operation of the SKIMO A/C unit. * Limited warranty The warranty doesn’t cover damages resulting from an incorrect operation of the SKIMO A/C unit, particularly for the following cases :
Operating in an environment with high salinity. Operating in an environment with high acidity. Cleaning with a pressure washer and/or with detergents. Consumable parts (filters) or considered as wear parts are also excluded from warranty.
TABLE OF CONTENTS
Section
Title
Page
1
INTRODUCTION
3
2
SECURITY INSTRUCTIONS AND WARNINGS
3
3
TECHNICAL CHARACTERISTICS OF THE KIT SKIMO SPLIT
4
4
KIT SKIMO SPLIT DESCRIPTION
6
5
BEFORE FITTING THE KIT SKIMO SPLIT
7
6
FURNITURE REQUIRED TO INSTALL THE KIT SKIMO SPLIT
8
7
PREPARATION OF THE KIT SKIMO SPLIT
8
8
CABIN WALLS PREPARATION TO RECEIVE THE UNITS
9
9
INSTALLATION OF THE KIT SKIMO SPLIT
10
10
ELECTRICAL CONNECTION
11
11
REFRIGERATED CONNECTING OF THE KIT SKIMO SPLIT
12
12
CHARGE THE KIT SKIMO SPLIT WITH REFRIGERANT R134A
13
13
ELECTRICAL DRAWING
14
14
KIT SKIMO SPLIT USE
15
15
REPAIRS
15
16
MAINTENANCE
17
17
EXPLODED VIEWS AND SPARE PARTS LIST
18
18
APPENDIX AND REVISIONS
22
If you have any question regarding the installation and use of the kit SKIMO SPLIT, please contact our quality service:
+33 (0)5 34 480 480
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
3/22
1. INTRODUCTION
The KIT SKIMO SPLIT described in this manual, is composed of an outside unit SKIMO SPLIT and an evaporator unit to be positioned inside the cabin. The compressor - condenser unit can be installed horizontally on a wall or flat on a hood
(see pictures).
The kit SKIMO SPLIT is particularly adapted to the compact machines with little room or a small driving power, to the machines the cabin of which is far from the engine and to the users wishing a fast and easy assembly. The SKIMO SPLIT unit has the compressor integrated and driven by an electric motor. 2 units will be linked between them by 2 hoses (high and low pressure) and electrically by a harness. ( See the recommendations on the power supply with the rest of the vehicle). The charge of regrigerant R134a will be made by a qualified and approved technician.
2. SECURITY INSTRUCTIONS AND WARNINGS
You must read and understand this manual before proceeding to the installation, set-up, use and maintenance of the kit SKIMO SPLIT.
List of pictograms used in this manual or on the unit:
Pictogram
Meaning
Pictogram
Meaning
Conform to CE standard
General danger
Read and understand the manual
Physical danger
Important information
The kit SKIMO SPLIT must be installed by a person qualified and adequately equipped. All alteration of the unit or incorrect installation are strictly forbidden and can be dangerous. SNDC SAS cannot be held responsible in the case of physical or material damages due to an alteration, installation or use that is different to that described in this manual
The SKIMO SPLIT unit weights approximately 30 kg. Take necessary precautions when handling, installing and using the unit to avoid any risk of injury, fall or damage. Do not handle or install the SKIMO SPLIT unit on your own.
Do not store, install or use the kit SKIMO SPLIT close by flammable liquids, gas or solids, or close by a heat source or in a place presenting risks of explosion or fire.
If the kit SKIMO SPLIT is damaged, it must not be used or turned on. It must be repaired or replaced first.
Flat mounting
Horizontal mounting
With horizontal
mounting only the
connectings on
the TOP
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
4/22
If repairs or maintenance operations are required on the kit SKIMO SPLIT, use a qualified company using qualified personnel to perform the operations. Any repair or maintenance operation that is not done properly can create risks of danger. Do not try to repair the SKIMO SPLIT by your own means if you are not qualified. For the charge or maintenance of the A/C refrigerant circuit, use a qualified company that is equipped with appropriate tools and security equipment and that uses original spare parts.
Do dot alter cabins that are certified « FOPS-ROPS »
In case of fire, do not open the unit cover. Extinguish the fire with an appropriate fire extinguisher for electrical and A/C units.
Contact the vehicle or machine supplier to enquire of the necessary changes regarding the papers (height of vehicle, weight…). Perform any necessary changes.
Always turn the kit SKIMO SPLIT and the vehicle or machine off before an operation of maintenance.
Disconnect all the electrical connections to the machine before fixing, or repairing the kit SKIMO SPLIT or before any operation that could involve getting in contact with the electrical circuit.
Do not introduce foreign objects inside the SKIMO SPLIT unit.
The kit SKIMO SPLIT contains moving parts that represent a danger. Do not disable the security features. Switch
the SKIMO SPLIT unit and the machine or vehicle off before opening the unit or taking the cabin panel off.
The A/C refrigerant circuit is under pressure. Do not open the A/C refrigerant circuit. This would create a loss of refrigerant gas that is colourless and odourless. It could create serous burns. The personal performing the repair or maintenance of the A/C refrigerant circuit must be qualified to manipulate such systems and must use appropriate tools, equipment and protection equipment. Wear protection goggles and gloves when you maintain the SKIMO SPLIT unit. Rejecting refrigerant gas in the atmosphere is strictly forbidden.
The kit SKIMO SPLIT must be maintained and cleaned up regularly from dust, vegetal or other wastes or combustibles to avoid risks of fire.
Use only original spare parts.
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
5/22
3. TECHNICAL CHARACTERISTICS OF THE KIT SKIMO SPLIT
The SKIMO SPLIT unit is the element positioned outside, it includes the following components : the condenser, the drying filter, the compressor, the electric components (electrical motor, fan, blower, harness, fuses), but also the electric harness of connection with the vertical evaporator unit positioned inside the cabin.
External dimensions:
o SKIMO SPLIT unit (+ ou - 1cm) : lengh 69 cm, width 42 cm, height 20.5 cm o Vertical evaporator unit (+ ou 1 cm) : lengh 41 cm, width 15.5 cm, height 41.5 cm.
Weight :
o SKIMO SPLIT unit 30 kg o Vertical evaporator unit 10 kg
Evaporator cooling capacity: 2900 W with +31°C air intake and 50% air humidity. Maximal consumption: 960W (that is 80 Amps electrical current for a 12V unit and 45 Amps for a 24V unit. Refrigerant HFC R134a quantity : according to the position of the outside SKIMO SPLIT unit (see board in chapter
number 12)
Oil: SP10 ISO 46 (SNDC Ref 430A09) (see board in chapter number 12)
205
420
688
414
155
410
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
6/22
4. KIT SKIMO SPLIT DESCRIPTION
DESCRIPTION
1. Condenser ventilator
2. SKIMO SPLIT cover
3. Ouside air intake grids
4. Drying filter
5. SKIMO SPLIT casing
6. M8 unit fastening screws (4)
7. Seal box of fuses and relays
8. Electric motor
9. Compressor
10. LOW-PRESSURE connect
11. HIGH-PRESSURE connect
12. Electrical harness
13. Control and air distribution plenum
14. Control panel
15. Air filter access grid
16. Grid fastening screws
17. Vertical evaporator unit fixations
18. Adjustable air louvers
19. Default signal light
20. A/C and ventilation speed selector switch
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
7/22
5. BEFORE FITTING THE KIT SKIMO SPLIT
Prior to fitting and using the kit SKIMO SPLIT, check the following points:
Cabin volume: Ideally the volume of the cabin is approximately 2m3 but if it is over 3m3 the performances of the SKIMO SPLIT system will decrease.
Cabin insulation: The cabin walls must be properly insulated, especially from important heat sources (engine, exhaust pipe, hydraulic system …). SNDC SAS cannot be held responsible in the case of poor performances of the SKIMO SPLIT system caused by poor cabin insulation.
Electrical power: The machine or vehicle engine must be equipped with an alternator able to supply the electrical power required from the vehicle or machine AND from the KIT SKIMO SPLIT. The SKIMO SPLIT system maximal consumption is 960W (80 Amps for a 12V unit or 40 Amps for a 24V unit). If the vehicle or the machine is equipped with an alternator that is not powerful enough, it must be replaced by a suitable alternator.
Roof and ceiling: Do not alter or make a hole in the cabin of vehicles that are certified « FOPS-ROPS » The walll must be stiff and strong enough for the Skimo SPLIT unit to be installed on. If it is not the case, the wall must be reinforced. The SKIMO SPLIT unit must not be installed if it would affect the stability of the vehicle or machine it is installed on, or if it would create excessive strains on its structure. Make sure using the drawing showing the dimensions of the unit and the cut-out area that there is enough space to fit the unit outside on the wall and the vertical evaporator unit n panel inside the cabin. The surface on which unit is installed must be flat and horizontal (+/- 5°). The cabin panel must be installed inside the cabin, and the user must be able to access the controls from his driving position while using the vehicle or machine.
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
8/22
6. FURNITURE REQUIRED TO INSTALL THE KIT SKIMO SPLIT
Two 16 mm
2
(12V) or 10mm² (24V) diameter cables to connect SKIMO to the vehicle’s battery : a black one for
the ground and a red one for the positive, fitted with M6 crimp terminals on the SKIMO’s end and crimp terminals on the battery’s end (according to the battery’s connection type, generally M10)
Caution: Maximum cable length: 5 m
One 1 mm
2
diameter cable to connect SKIMO to the D+ signal (“engine running”) of the alternator, with a 1 way FASTON connector (male housing, female contact) and a connector on the other end to connect to the D+ signal coming from the alternator.
A fuse holder and a 100Amps (12Volts) or 50Amps (24Volts) fuse.
The above mentioned components are available as a connection optional set, reference 274B56 (12Volts) or 274B58 (24Volts)
7. PREPARATION OF THE SKIMO SPLIT
1. Open the cardboard of the SKIMO SPLIT unit.
2. Remove the foam protection surrounding the 2 units.
3. Take the SKIMO SPLIT unit, remove the 4 screws of the cover to reach in the 4 unit fastening screws
4 unit
fastening
holes
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
9/22
8. CABIN WALLS PREPARATION TO RECEIVE THE UNITS
Preparation for fastening the SKIMO SPLIT unit
Dimensions en millimeters (mm)
Drill in the chosen wall 4 holes in diameter 10 mm according to the plan of setting-up above.
Preparation for fastening the vertical evaporator unit
Dimensions en millimeters (mm)
Drill in the chosen wall 4 holes in diameter 8 mm according to the plan of setting-up above.
4 holes
4 holes
CABIN FLOOR
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
10/22
9. INSTALLATION OF THE KIT SKIMO SPLIT
The SKIMO SPLIT unit is heavy (approximately 30 kg). Take necessary precautions to avoid hurting
yourself or damaging the unit. Never install the unit on your own.
Location of the SKIMO SPLIT unit
Fix the SKIMO SPLIT unit to the wall by means of the supplied stainless screws 4 HM8-20 + 8 flats M8 and 4 slices EPDM
8.5x20mm and 4 nuts HM8.
Access of the 4 fastening unit
Nut HM8
Flat M8
Screw HM8-20
EPDM slice
Inside of the
SKIMO SPLIT
Wall vehicle
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
11/22
Location of the vertical evaporator unit
Fix the vertical evaporator unit to the wall by means of the supplied stainless screws 4 HM6-25 + 8 flats M6 and 4 nuts HM6.
10. ELECTRICAL CONNECTION
The installer must make sure that the cables are insulated and protected from any risk of deterioration
or tear-up (from branches for example) and that they do not present any risk for people or appliances.
The passage of electric cables will be made on the side of the unit.
Inside the cabin
Exit electric harness
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
12/22
Do not lay the cables out near the motor and compressor belt located at the back of the unit.
Once the cables laid out, connect them as follows to the SKIMO unit electrical motor:
1. Take the 2 nuts of the motor (+) terminal off. Insert the red cable through the rubber cover.
2. Screw the nuts back on onto the red cable and red wires crimp terminals and the washer.
3. Put the rubber cover back into place. Repeat 1 and 2 on the motor (-) terminal with the ground black cable and wires.
4. Connect the cables to the battery or to the alternator. The fuse housing with its fuse (100Amps for 12Volts, 50 Amps for 24Volts) must be fitted on the red positive cable less than 15cm away from the crimp terminal connected to the (+) terminal of the battery or of the alternator.
Caution: The positive (+) cable MUST be protected by a 100Amps (12V) or 50 Amps (24 V) fuse located
as close as possible to the power source.
Make sure that the section of the cables between the battery and the alternator is big enough for the current required by the SKIMO SPLIT (80 Amps for the 12Volts unit, 40 Amps for the 24Volts unit) and by the other electrical equipments of the vehicle.
5. Connect the 1-way FASTON located inside the cabin to the D+ signal from the alternator (signal indicating that the engine is running) with a 1mm² section cable.
6. Plug the ventilator connector back and fasten unit cover back on with its 4 screw.
11. REFRIGERATED CONNECTING OF THE KIT SKIMO SPLIT
Connect the SKIMO SPLIT unit and the vertical evaporator unit by 2 hoses with oring steel fittings to be determined by the customer:
A flexible hose M6, high pressure, connecting the entrance of the evaporator unit to the entrance of the SKIMO SPLIT unit.
A flexible hose M10, low pressure, connecting the exit of the SKIMO SPLIT unit with the exit of the vertical evaporator unit.
Lubrificate lightly each Oring with the same oil SP10 or PAG 46 than for the compressor before connecting any fitting. Make sure the hoses be correctly connected, so as not to be in contact with cutting parts or heat source. When flexible hoses cross a wall, it’s necessary to use one thread rubber or adapted protective plastic ducts.
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
13/22
12. CHARGE THE KIT SKIMO SPLIT WITH REFRIGERANT R134a AND OIL
Complete the unit with 30 cc of SP10 ISO 46 oil.
The charge of R134a of the kit SKIMO SPLIT will be a function:
Of the position of the SKIMO SPLIT unit outside. Of the total length in flexible hose.
Position SKIMO SPLIT unit
Length flexible hoses
Flat
Horizontally
2 meters
480 g
480 g
4 meters
500 g
500 g
6 meters
550 g
550 g
For the charge or maintenance of the A/C refrigerant circuit, use a qualified company that is equipped with appropriate tools and security equipment and that uses original spare parts.
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
14/22
13. ELECTRICAL DRAWING
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
15/22
14. KIT SKIMO SPLIT USE
The SKIMO SPLIT is designed to run when the vehicle’s engine is running. If the unit is turned on while the vehicle’s engine is off, the alternator will not feed the unit and there is a risk of battery discharge.
The ability of the SKIMO SPLIT to maintain the required temperature inside the cabin depends on the amount of heat that penetrates inside the cabin. Some preventive measures are necessary to lower the amount of heat that enters the cabin and to improve the performances of A/C system :
- Park the machine or the vehicle in the shade.
- Drive for a few minutes with the windows opened to lower the temperature inside the cabin before turning the
A/C unit on.
- Keep the doors and windows closed while using the A/C unit.
- Avoid using devices that produce heat.
Operating modes:
- Once the kit SKIMO SPLIT is installed and the vehicle’s engine is running, turn the control panel ventilation speed selector switch to first speed to turn the unit on. The first ventilation speed and the air conditioning are turned on.
- Adjust the ventilation speed to 1, 2 or 3 according to your requirement with the ventilation speed selector switch.
- To switch the unit off, turn the ventilation speed selector switch to 0.
Switch the kit SKIMO SPLIT off if the vehicle’s or machine’s engine runs on low speed for an extended amount of time (for over 15 minutes). If not, there is a potential risk of battery discharge due to the fact that the alternator might not supply enough power when the engine runs at low speed. The SKIMO SLIT unit would turn to security mode. If that happens, refer to section 15.
It is normal for the internal thermostat to regulate the A/C unit if the blowing temperature is too low, in which case the blowers still run but the air conditioning is turned off for a while.
SNDC SAS cannot be held responsible for condensation appearing on the cabin’s surfaces. The air contains moisture
that tends to condensates on cold surfaces. Appropriate cabin insulation can prevent or lover the risks of condensation.
15. REPAIRS
If the A/C circuit hasn’t got the correct amount of gas, the performances of the A/C system will lower. If it seems that your SKIMO SPLIT unit doesn’t work properly, you should take it to an A/C specialist.
Never try to repair faults by your own means. Repair and recharge of an A/C circuit must be carried out
by a specialist that is qualified, certified, equipped with necessary tools and that will use original spare parts.
If one of the security systems is activated, the air conditioning system is turned off (no more cold production) and the default light is switched on on the control panel. To reset the Skimo A/C unit after a security cut off, turn it off and on again. A security cut off should not be a recurring feature. In the case of repeated cut offs, contact your qualified specialist.
Révision D
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
16/22
Error codes:
Error code
Failure
Repair required
1 blink
Overheating of the electrical motor. The temperature of the motor went over 113°C. The unit can be reset by switching it off and
on again only once the motor’s temperature
is lower than 109°C
Check that the air way cooling the electrical motor is not clogged up.
To be done by an A/C specialist:
Check that the A/C circuit hasn’t got too much
gas R134a.
2 blink
The battery is flat. The tension of the battery went lower than 9.5V (for a 12V unit) or 14V (for a 24V unit)
Check that the battery gets charged up properly and that the alternator is powerful enough. Check that
the vehicle’s engine doesn’t run at low speed for
extended periods of time (over 15 minutes)
3 blink
Over consumption of the electrical motor
Check the power consumption of the SKIMO SPLIT.
To be done by an A/C specialist:
Check that the A/C circuit hasn’t got too much
gas R134a.
5 blink
High voltage. The tension of the battery went over 18V (for a 12V unit) or 32V (for a 24V unit)
Check that the alternator supplies its nominal voltage, and that the nominal tensions of the alternator, of the battery and of the SKIMO SPLIT are identical.
6 blink
Low voltage. The tension of the battery went lower than 10.5V (for a 12V unit) or 21V (for a 24V unit).
Check that the battery gets charged up properly and that the alternator is powerful enough. Check that
the vehicle’s engine doesn’t run at low speed for
extended periods of time (over 15 minutes)
Light on continuously
A/C system gas low pressure. The pressure switch is activated for a pressure lower than 2 bars in the high pressure part of the circuit in case of the quantity of gas being too low (caused by a leak for example).
To be done by an A/C specialist: Check the airtightness of the A/C circuit and recharge with R134a gas.
Light AND electrical motor on and off
A/C system gas high pressure. The pressure switch is activated for a pressure higher than 14 bars in the high pressure part of the circuit.
Check that the condenser is not clogged up.
To be done by an A/C specialist:
Check that the A/C circuit hasn’t got too much
gas R134a.
Light not on but unit not working
The Skimo A/C is not working properly but the default light is not switched on. This can be due to an electrical problem.
Check that the default LED light works properly. Check the fuses, the relays, the electrical harness, the connectors and the electrical connection between the Skimo unit and the vehicle or the machine.
There are two other security systems on the kit SKIMO SPLIT:
Compressor security: The compressor is equipped with a security pressure valve to protect the system in case of a pressure switch failure.
Machine security: The SKIMO SPLIT unit is equipped with a sensor that disables the SKIMO SPLIT unit if the cover is opened.
Use only original spare parts.
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
17/22
16. MAINTENANCE
The SKIMO SPLIT must be maintained and cleaned up regularly from dust, vegetal or other wastes or combustibles to avoid risks of fire. The frequencies listed below are for reference only. The maintenance must be done more frequently if the working environment can lead to clogging up, premature wear or deterioration of some parts.
The SKIMO SPLIT unit contains parts that are moving that can present a danger. Never disable the security features. Always turn the unit and the vehicle off before opening the cover or taking the cabin panel off.
Switch the unit off before any maintenance.
Every 50 hours:
Clean the dust filter Check the condenser, the ventilator, the main casing. Clean if necessary
In winter:
Turn the Skimo A/C unit on once a week even for a short time (1 minute) to guarantee the lubrication of the seals inside the A/C circuit.
Every 200 hours:
Check the motor-compressor belt tension: Tension too high: Risk of premature wear of the compressor bearings. Tension too low: Risk of premature belt wear. Replace the air filter (SNDC Ref 281G47). Check that the water drain holes in the main casing and in the evaporator casing are not clogged up.
Every two years: (To be done by an A/C specialist) Clean the condenser and the evaporator coils. Clean the water drain holes in the main casing and in the evaporator casing. Recover the A/C circuit gas and replace the receiver dryer (SNDC Ref 225A13). Check the A/C circuit air tightness. Recharge the circuit and check the thermostat and the pressure switch. Check the oil level.
Every five years or 2000 hours: (To be done by an A/C specialist) Check and tighten all the screws and nuts. Replace the motor-compressor belt.
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
18/22
17. EXPLODED VIEWS AND SPARE PARTS LIST
SKIMO SPLIT unit
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
19/22
Item
12 volts
24 volts
Description
Qty
1
520C23
520C23
Cover SKIMO SPLIT unit
1 2 296C34
296C34
Condenser coil
1 3 520C17
520C17
Support condenser and air plenum
1 5 520C18
520C18
Support condenser
1 6 235L16
235L16
Receiver dryer-condenser A/C hose #6
1 7 235L15
235L15
Condenser-compressor A/C hose #8
1 8 235L14
235L14
Exit unit-compressor A/C hose #10
1
11
540F70
540F71
Electrical motor
1
12
200H05
200H05
Compressor
1
13
560C16
560C16
Motor bracket
1
14
560C26
560C26
Comprressor bracket
1
15
260A40
260A27
Ventilator
1
16
520C16
520C16
Frame SKIMO SPLIT unit
1
17
235L17
235L17
Exit unit-receiver drier A/C hose #6
1
20
274C49
274C50
Electrical box
1
21
264A59
264A59
Pressostat
1
22
233A17
233A17
Receiver drier clamp bracket
1
23
225A13
225A13
Receiver dryer filter
1
24
273D14 273D15
273D14 273D15
Magnetic sensor security
1
26
274B71
274B71
SKIMO SPLIT unit electrical harness
1
27
242C48
242C48
Compresor fitting #10
1
28
274C49
242C49
Compresor fitting #8
1
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
20/22
Vertical evaporator unit
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
21/22
Item 12 volts
24 volts
Description
Qty
1
530C44
530C44
Casing
1 2 530C45
530C45
Plenum
1 3 530C47
530C47
Bracket blower
1 4 530C46
530C46
Air filter access grid
1 5 261A25
261A26
Blower
1 6 294C07
294C07
Evaporator
1 7 530C48
530C48
A/C pipe #6
1 8 250A16
250A16
Expansion valve
1
9
370C44 370B32
350C44 370B32
Adjustable air louvers
5
10
370D43
370D43
Control panel adhesive
1
11
265A37
265A37
Thermostat
1
12
370D44
370D44
Control panel
1
13
234A18
234A18
Grommet 35mm
1
14
690A47
690A47
Specific screw M4-15
1
15
650A07
650A07
Flat washer stainless M22
1
16
243A06
243A06
Nut A/C pipe #10
1
17
650A16
650A16
Flat washer stainless M16
1
18
640A17
640A17
Grower washer stainless M16
1
19
660A20
660A20
Nut A/C pipe #6
1
20
281G47
281G47
Air filter
1
21
274B70
274B70
Electrical harness
1
22
281K41
281K41
Back wall insulation
1
23
281K42
281K42
Side wall insulation
1
24
281K43
281K43
Front wall insulation
1
25
281B80
281B80
Conector DEUTSCH gasket
1
26
281A24
281A24
Wall fitting gasket #10
1
27
281A03
281A03
Wall fitting gasket #6
1
SKIMO SPLIT
PART NUMBER : 320B05 (12V) / 320B06 (24V)
INSTALLATION, USER AND MAINTENANCE MANUAL
22/22
18. APPENDIX AND REVISIONS
Revisions
Version
Date
Objet
0
May 2010
Creation
1
July 2010
Modifications.
2
November 2011
Modify electric drawing.
3
June 2015
Update of the expolded views and the type of oil.
Loading...