SKC 690-300 User Manual

Operating Instructions
12345
Tel: 724-941-9701 Fax: 724-941-1369 e-mail: skctech@skcinc.com
Secondary Diffusion Barrier for
ULTRA III Passive Samplers
Cat. No. 690-300
Wear gloves to install and remove the secondary diffusion barrier (photos shown without gloves for clarity).
863 Valley View Road, Eighty Four, PA 15330 USA
from sampling holes. To do this, press the end of the
Clip
Cover
sampler without holes against the heel of your hand and use fi ngertips of same hand to slide cover toward palm until cover is fl ush with end of sampler.
2. Grip sampler tightly with thumb covering sampling holes. Grip cover and slide it off end of sampler.
3. Align channels on secondary diff usion barrier with slide rails on sampler. Slide diff usion barrier toward sampling
Stop
holes until barrier rests against stop.
Secondary diffusion barrier
4. A er desired sampling period, remove sampler from worker. Immediately remove secondary diff usion barrier using the same technique described in Steps 1 and 2.
Clip
Barrier
Dispose of barrier using appropriate procedures.
5. Immediately replace cover by aligning channels with slide rails on sampler and slide cover toward sampling holes until cover rests against stop.
Stop
For detailed instructions on using the SKC ULTRA III Passive Sampler, go to www.skcinc.com/prod/690-101.asp.