INTRODUCTION

In this user manual, you will find information and advice for using, operating and maintaining Sit & Shower.
Sit & Shower is designed for homecare and inpatient purposes. Sit & Shower is to be used exclusively for assistance during showering, bathing or using a toilet. Sit & Shower is not designed for long periods of sitting.

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS.
Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution, and care should be exercised when installing, maintaining, or operating the device. ALWAYS contact the manufacturer about problems or conditions you do not understand.
Safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
“WARNING” indicates a potentially hazardous situation which, if not avoided, may result in death or serious injury.
“CAUTION” indicates a hazardous situation which, if not observed properly, may result in serious consequences.
1. Use the device only for its intended use as described in this manual.
2. Install and use the shower chair only indoors, on solid, even, level and non-slippery surfaces.
3. WARNING: Install the device in accordance with these instructions. Use supply wires that are suitable for 75°C (167°F), including the temperature rating of the supply conductors to be used. This unit should be electrically grounded and installed by a licensed contractor, electrician, and plumber. Building materials and wiring should be routed away from the motor/pump or blower or other heat producing components of this unit. A pressure wire connector is provided on the exterior of the motor/pump and heater to permit connection of an No. 8 AWG solid copper bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity, as needed to comply with local requirements.
4. Do not use the device on an incline greater than 5°.
5. WARNING: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
6. WARNING: Only allow children to use the appliance without supervision when adequate instructions have been given so that the child is able to use the appliance in a safe way and understands the hazards of improper use.
7. Never drop or insert any object into any opening of the device.
8. RISK OF ELECTRIC SHOCK: The device must be connected only to a dedicated electrical supply circuit that is protected by an Earth Leakage Circuit Breaker (ELCB). The ELCB should be tested on a routine basis by the homeowner. To test the ELCB push the test button. The ELCB should interrupt power. Push the RESET button. Power should be restored. If the ELCB fails to operate in this manner there is a ground current fault, indicating the possibility of an electric shock. Do not use the device. Disconnect the power and have the problem corrected by a qualified service electrician. Re-test the ELCB and only when it is operating properly may the device be used.
9. The appliance should be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
10. RISK OF ELECTRIC SHOCK: A terminal is provided on the exterior of the pump. To reduce the risk of electric shock, connect this terminal to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment. Save These Instructions.
11. RISK OF ELECTRIC SHOCK: It is NOT recommended to use the device whilst lightning, thunderstorm or under any extreme weather conditions.
12. CAUTION: Glowing cigarettes are to be fixed in a conspicuous place beside the toilet. Glowing cigarettes and other burning materials should not be thrown into the toilet.
13. CAUTION: Water temperature in excess of 106°F (42°C) or less than 96.8°F (36°C) may be injurious to your health and harmful to your skin. Check and adjust water temperature before use.
14. CAUTION: Maximum temperature of hot water input should not exceed 55°C.
15. CAUTION: To reduce the risk of infection or injury, please ensure the device is connected to sanitized hot and cold water supplies. Failure to maintain water quality may lead to unhealthy conditions for shower and increase risk of contracting waterborne illnesses and/or respiratory ailments. Poor water quality may also damage the device’s shell and components and the shower chair, which are not covered under the warranty.
16. CAUTION: Showering for too long may be harmful, especially for seniors. It is recommended not to shower for more than 10 minutes.
17. CAUTION: To prevent falling, always wear the seat belt while showering. Whilst using the device the user should remain calmly seated. Excessive movement should be avoided.
18. Sitting down, standing up and moving the patient should be supervised by a qualified care-worker, as to the health condition of the patient. Always use handlebars as a precautionary measure when sitting down or standing up.
19. WARNING: To prevent falling, do NOT lean on the side and foot panels which are not intended to support your body weight. Do NOT lean on the handlebars frame or use them to support your body weight if you find any moving parts in them. Condition checking of the handlebars and frame should be done regularly.
20. CAUTION: Bathroom floor may be slippery, to prevent falling, please be careful when walking in and out of the device. Please make sure the bathroom floor is slip proof.
21. CAUTION: Do not exceed the recommended supporting capacity of the device - 100kg (220lbs).
22. WARNING: To avoid resident infection and contamination of the device, disinfect the device and the shower chair after initial set up and ALWAYS disinfect the device and the shower chair AFTER each use.
23. CAUTION: Do NOT disinfect the device when it is occupied otherwise injury may occur.
24. ALWAYS wear gloves, protective apron, and face shield protection when disinfecting or cleaning the device.
25. ALWAYS handle disinfectants, cleaning compounds, and powdered sanitizers with extreme care. Warranty does not cover physical or mechanical damage caused by improper handling or usage of the device.
26. CAUTION: Do NOT be anywhere near the device during the disinfectant cycle. Doing so could result in skin or eye contact with the disinfectant, which is corrosive. If contact is made, rinse IMMEDIATELY with water. If irritation occurs, consult a physician.
27. WARNING: To prevent residue of sanitizer, DO NOT stop the device during auto­disinfection cycle and please ensure the disinfection cycle is complete.
28. NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of these types of cleaners may make the finish of the device scratched and dull. NEVER use cleaners containing concentrated hydrogen peroxide, iodine, bromine, povidone-iodine or methylene blue. The use of these types of cleaners may cause the device to stain. Never use cleaners containing concentrated bleach. Use of these types of cleaners may dry out the rubber seals and gaskets and the tub may not function properly.
29. During assembly, use or cleaning, be careful not to put your fingers between any moving parts.
30. Avoid reaching into the hinges areas to prevent body parts or objects from getting pinched.
31. Do not modify or reconstruct the device or use attachments NOT recommended by the manufacturer.
32. DANGER: If you are or think you may be pregnant, consult your physician before using the device.
33. Whilst the device is being adjusted, the user must be kept away from moving parts.
34. The device should be used with care.
35. Do not operate the device if damaged, malfunctioning, partially disassembled, or if it has missing or broken parts or you suspect it is faulty or broken. Contact your distributor or Automation for Humanity Ltd. directly.
36. Installation, maintenance, and repair should be performed by a qualified installer. Work by unqualified persons could be dangerous and may void the warranty.
37. The appliance is only to be used with the power adaptor unit provided with the appliance.
38. Glowing cigarettes is to be fixed in a conspicuous place beside the toilet. Glowing cigarettes and other burning materials must not be thrown into the toilet.
39. Separate electrical appliances producing steam or humidity are not to be used inside the cabinet.
40. CAUTION: Do not exceed the water pressure range 0.2 – 0.6MPa (2.0-6.0 bar).
41. CAUTION: Do not exceed the cold and hot water supply temperature range Cold water: 5°C (41°F), Hot water: 55°C (131°F)
42. The appliance must only be supplied at safety extra low voltage corresponding to the marking on the appliance.
43. : CAUTION: Hot surface
44. To obtain additional or electronic copies of the manual; please email info@sitnshower.com
45. The device should be installed above a toilet such that the central hole of the device is aligned with the center of the toilet bowl.
46. To clean the device, please utilize the regular disinfection cycle and follow up with a gentle wash with a mild detergent or disinfecting cleaner.
47. Regular cleaning of the toilet bowl can be done with an L-shaped or curved brush. For more extensive cleaning, please disconnect the power source, turn off the water supply and ensure that the inlet water supply pipes have cooled. Gently pull the device out to clean the toilet and device. After cleaning, first place the device back into its proper position before restarting the water supply and connecting the power source
48. Regular cleaning the appliance is necessary to ensure hygienic conditions
49. Turn off and disconnect the appliance from the power source before cleaning or maintenance.
50. The appliance should connect to water mains with the hose sets which have complied with IEC 61770.

INSTALLATION INSTRUCTIONS

SAFETY PRECAUTION

To prevent damage to human body or property loss, please read through the following instructions before installing Sit & Shower (herein referred as “this product”). Please comply with the following content as damage will be caused if used incorrectly.
This product should be installed by qualified plumber or service agent.

PRECAUTION BEFORE INSTALLATION

CLAIM

Before finishing the installation, please DO NOT plug in or connect to the power socket,
otherwise damage may be caused.
Please ONLY use the components provided in the package for installation.
This product is suitable for water pressures between 0.2MPa ~ 0.6 MPa and water flow larger
or equal to 7 L/min.
If the ground is not level, the device could wobble and may not be secure

REMINDER

This product has been factory-tested under wet conditions; some water may remain on the
packaged product

PREPARATION BEFORE INSTALLATION

CONFIRM THE POWER SOURCE

Before installation, please ensure the power socket in your place can fulfill this product’s requirement and ‘ground’ it correctly. If it cannot be ensured, please find a qualified electrician to confirm. Switch of the power supply before connecting the transformer.
The transformer should be installed on the ceiling or away from any source of water and at least 2 meters above floor or put on top of the false ceiling.
This appliance must only be supplied by safety extra low voltage corresponding to the marking on the appliance.
This appliance must only be connected and installed by the power connector provided by the qualified plumber or service agent.

CHECK THE DIMENSIONS OF THE TOILET AND THE SPACE OF INSTALLING THE PRODUCT

Make sure the installation site has at least 880 mm width and 1200 mm depth for installation and maintenance.
1. CLOSE THE INSTALLATION SITE’S WATER INLET VALVES
Make sure both the hot and cold water inlet valve are closed.
2. UNINSTALL THE ORIGINAL WATER FAUCET
3. PREPARE INSTALLATION TOOLS
Wrench
4. CHECK IF FULL ACCESSORIES ARE INSIDE THE PACKAGE
Name Quantity
A User manual, Installation manual, Quick manual 3 kinds
B Remote control 1 piece
C Transformer 1 piece

INSTALLATION OF PRODUCT

CONNECTION OF WATER SUPPLY

Before installing the water inlet pipe, make sure the original water faucets are uninstalled and the water inlet valves are closed.
From the back view of the device, the pipe on the left hand side is hot water inlet pipe, the pipe on the right hand side is cold water inlet pipe. Connect them with the corresponding water supply using wrench. DO NOT connect the hot water pipe to the right side or the cold to the left, otherwise this product will not function normally.

INSTALLATION OF ELECTRICAL PART

(PLEASE PREPARE ACCESSORIES B AND C)
1. CONNECT THE REMOTE CONTROL ON THE MACHINE
a. Connect the socket of remote control according to the picture shown below and
place the remote control to the remote control stand.
2. CONNECT THE 13A 220V POWER SOCKET
Reminder: Before connecting power to the power socket, it is highly recommended that all electricity supply is shut off and that an independent switch for the power socket is installed beforehand
10

DEVICE TESTING

1. TURN ON THE MAIN POWER SUPPLY AND THE WATER INLET VALVES
2. TURN ON THE DEVICE
When the device is turned on, you can hear two long beeps and two short beeps sound. And the display on remote control will be blinking.
3. PRESS “STANDBY” BUTTON TO CHECK IF ALL NOZZLES HAVE WATER COMING OUT
This process will finish within 1 minute.
4. PRESS “START/TIME+” BUTTON TO CONFIRM THE BATHING PROGRAM CAN FUNCTION NORMALLY
After pressing the stated buttons, the bathing program will start after 5 seconds.
5. THIS PRODUCT IS READY TO USE
11

OPERATING INSTRUCTIONS

PREPARATION

Open hot and cold water supplies and water heater, ensure they operate properly. Please allow enough time for heating up water before using Sit & Shower if you are using storage tank water heater.
Warm up the device every time before showering or if the device has not been used for a while. The warm up process takes approximately 30 -60 seconds. If device is beeping after 1 minute, it is an indication that the warm up function cannot finish as the temperature of incoming hot water supply is lower than the temperature you set. Please check if your water heater is functioning normally.
CAUTION: Maximum temperature of hot water input allowed is 55°C.
WARNING: To prevent temperature shock, the device should be warmed up before using the handheld shower or before a user sits on it. WARNING: To avoid resident infection and contamination of the device, disinfect the device and the shower chair after initial set up and ALWAYS disinfect the device and the shower chair AFTER each use.

SHOWER GEL & SHAMPOO

Clear bottles are provided with the device for storing shower gel and shampoo. Please do not fill up the bottle with exfoliating shower gel, or body scrub.

REMOTE CONTROL

When pressing button, please hold for 0.5 second with a bit of force until you hear 1 short beep, it is designed in this way to prevent user accidently pressing any button. If you press the button too shortly or with not enough force, the remote is not be able receive the signal.
12
①:temperature & info display
1. Open hot and cold water supplies and water heater. If you are using storage tank
heater, please allow enough time for heating up water before using Sit & Shower.
2. Ensure the shower gel and shampoo bottles contains enough shower get and shampoo
for shower.
3. Turn on Sit & Shower device
4. Set temperature: temperature range: 38°C - 43°C
a. Press Temp.
temperature is blinking.
b. Press once more to raise or lower temperature by one degree, temperature is set
at a sequence of “38°C, 39°C, 40°C, 41°C, 42°C, 43°C, 42°C, 41°C, 40°C, 39°C, 38°C”.
c. When temperature stops blinking, it indicates you have existed the temperature
setting stage.
d. Default temperature will be the last temperature set.
5. Press Standby
handheld shower. The device is warming up to reach the set temperature, the current temperature is displayed and blinking indicating it’s adjusting by the device. If device is beeping after 1 minute, it is an indication that the warm up function cannot finish. Please check if your water heater is functioning normally.
6. Select shower program:
a. Default shower program only wash the body without hair or private part.
水溫調較
準備
once to activate temperature setting stage where
every time after adjust temperature, before showering or use
13
b. Extra features selection selected features will be included in shower program.
洗髮
i. Press “Hair wash
1. Hair wash button light is on: hair nozzles are selected
2. Hair wash button light is off: hair nozzles are unselected
ii. Press Bidet
1. Bidet button light is on: bidet is selected
2. Bidet button light is off: bidet is unselected
7. Start a shower program: Press “Start/Time+
shower program will start after 5 seconds. Default duration: 4 mins 30 secs. Program will stop automatically when time runs out.
8. Extend rinsing time: after starting a shower program, press “Start/Time+
once to extend rinsing time by adding one rinsing cycle, press twice to add two more rinsing cycles.
Other functions:
臀部洗淨
once to select/deselect hair nozzles
once to select/deselect bidet
開始/加時
to start a shower program,
開始/加時
Handheld shower: Press Handheld
turn off. (Warning Please warm up device before using handheld shower)
沖廁
Flush toilet: Press Flush
Press
Device disinfection: Press Flush
Caution
Stop
you hear 3 beeps. During disinfection, device will keep beeping to indicate that disinfection function is still running, and no user should be allowed to use the device or be near the device during disinfection.
a. Prepare disinfectant in disinfectant bottle. It is recommended to use Dettol or
b. Please ensure disinfection cycle is complete to prevent disinfectant residue, do
During standby stage, if temperature of incoming water is higher/lower than set
temperature, device will dispose of water until it reaches the set temperature.
If standby function
signal that temperature of incoming water is too high or too low for device to reach set temperature. Please check your water heater and hot & cold water supplies.
If you try to adjust temperature or open other faucets that share the same hot water
supply with the device while shower program is running, due to insufficient hot water supply, device will resume automatically after it finishes adjusting temperature (takes ~3s). If you need to use other faucets while using Sit & Shower, please open them before warming up device to avoid this problem.
停止
” once to stop any running function.
any neutral disinfectant. Please do not use bleach to clean the device.
not stop disinfection function before it finishes.
stops after 1 minute and device keeps beeping, it’s a warning
” once.
手提淋浴
沖廁
” and Stop
once to turn on; press a second time to
停止
” together for 5 seconds until
device may suddenly stop
14

CARE AND MAINTENANCE

The device requires regular inspection. Check the device frequently for rips or tearing, breakage, holes or lost parts and/or non-functioning parts. Check all nuts and bolts are present and secured and any straps are in a good state of repair. Remove dirt and grease from the castors and check that the brakes are working effectively. We recommend that a competent person who is familiar with the product undertakes the regular checks and the device and the shower chair is removed from normal use when it is clear they are not functioning correctly or safely. The device should be cleaned regularly and as required. To clean the device, simply use a mild, nonabrasive liquid detergent solution, and turn on the self-cleaning function of the device. Do not use a bleach solution. To do so invalidates your guarantee. Use a recommended disinfection solution with the chair. Follow the instructions on the bottle for the correct dilution. The device should be rinsed in plain water after cleaning and disinfection. Advice: Do not use any aggressive cleaning materials or hard brushes. To do so may invalidate your guarantee.

WATER MAINTENANCE

To reduce the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water quality within specified limits. This will enhance your enjoyment and prolong the life of the device.
Water maintenance requires regular attention on balancing several factors regarding water chemistry.

WATER pH CONTROL

it is important to maintain the input shower water at a slightly alkaline condition of 7.4 to 7.6 pH. Problems become proportionately severe the further outside of this range the water gets. A low pH may be corrosive to metals in the device. A high pH may cause minerals to deposit on the interior surface (scaling).

DEVICE SANITIZATION & AUTO-DISINFECTION FUNCTION

To destroy bacteria and organic compounds on the device surface and in the water pipes, device disinfection should be done regularly. Device should be sanitized before using for the first time and after every use.
Failure to clean the device can cause cross contamination. User can manually sanitize the device or use the automatic disinfection function of the device.
To use the automatic disinfection function, first add sanitizer to the sanitizer bottle on the device and activate the disinfection function, device will automatically:
1. Dilute sanitizer to the preset concentration and spray it onto the device’s surface through
nozzles
15
2. Stop spraying and leave device wet for contact with the sanitizer
Model
Sit & Shower
Dimensions
Outer
1100 mm L x 820 mm W x 1580 mm H Seat width front
550 mm
Seat width rear
550 mm
Seat depth
440 mm
Dry Weight
45 kg
Toilet height
clearance
410mm
Seat
1 person
Recommended
150 kg
Material
Shell Material
Acrylic/ABS
Frame Material
Steel
Jet Configuration
Handheld Shower
Filtration System
Filter
1 pc
Foot tray
1 pc
Electrics
Control tablet
1 set
3. Rinse off sanitizer with water
During the auto-disinfection cycle, device will keep beeping for warning user the disinfection function is on. WARNING: To avoid eye or skin irritation, Do NOT be anywhere near the device during auto-disinfection cycle.
User should always check the sanitizer bottle to make sure there’s enough sanitizer. The user is responsible for selecting the correct sanitizer and employing the correct concentration to the sanitizer.
WARNING: To prevent residue of sanitizer, DO NOT stop the device during auto-disinfection cycle and please ensure the disinfection cycle is complete.
WARNING: User should check frequently and use their best judgement to ensure the device is clean for use and free from cross-contamination. Automatic disinfection function alone cannot guarantee good device hygiene. It also depends on the sanitizer used, sanitizer concentration and other factors all affect the device hygiene level. A clean environment and good hygiene practice are also essential.

TECHNICAL SPECIFICATIONS

Maximum load
Dimensions
Total Jets 11/13 pcs
head
1 pc
16
Voltage
12V 5A
Water supply
G1/2 tube

LIMITED WARRANTY

Automation for Humanity Limited (the “Company”) provides limited warranty to the original purchaser of this Product against defects in material or workmanship for a period of 365 days from the initial date of delivery. If this Product is determined to be defective, the Company will repair or replace the Product, at its sole discretion, at no additional charge. This same Warranty Period applies to all replacement or repaired Products. After the Warranty Period, you must pay for all Product servicing including parts, labour and shipping charges.
This limited warranty does not cover defects, damage or failure caused by user, installer, or other persons, pets, or rodents, or resulting from, without limitation, any of the following: careless handling including its own negligence; modification of any type for any reason (including modification to meet local codes); improper installation; connections supplied by the installer of the equipment; improper voltage supply or unauthorized electrical modification; unreasonable or improper use, falls from a height; incorrect operation, or lack of proper routine maintenance; operation of the unit without specified minimum amount of water or at inappropriate water temperature; use of abrasive or improper cleaners; or natural disasters, such as lightning, floods, earthquakes, etc. this limited warranty does not apply to the Product surfaces( i.e., discoloration, scratches or wear and tear arising from use).
In addition, the company will not be responsible for incidental or consequential damages or losses arising from any cause (e.g., water damage to carpet, ceiling, tiles, marble, loss of use, etc.) including its own negligence; damages to, respecting, or resulting from: optional bath equipment not manufactured by the Company but supplied by dealer, installer or the Company; the unit's prior usage as an operational display; or defects that should have been discovered before installation.
This limited warranty does not include: labor, transportation, or other costs incurred in the removal and/or reinstallation of the original unit and/or installation of a replacement unit; any costs relating to obtaining access for repair; or loss of use damage, including loss of sales, profit or business advantage of any kind under any circumstances. Units are excluded from any warranty coverage if any addition, deletion, or modification of any kind whatsoever has been made to the unit (or to any component). The warranty is void if the ownership or original installation location is changed (device is relocated). Warranty coverage is provided in Hong Kong or its territory of purchase.
17
First name
Last Name
Address line 1
Address line 2
Country
Email
Product serial
number
Purchase date
The product comes with a user manual that provides instructions on how to use, operate and maintain the device. Please make sure you understand the instructions. If necessary, refer to the Sit & Shower website or contact our customer service for further assistance.
In the event of a warranty claim, the warranty is valid only when a filled customer information form (found at the end of this user manual) and a proof of purchase (i.e., a receipt) are provided.
Loading...