Product Introduction
The unit is a photoelectric 3V DC smoke and heat alarm. It is operated by 3v AA Alkaline battery. With the photoelectric technology, it is more sensitive in detecting slow smoldering fires which generate light smoke.little heat and may smolder for hours before bursting into flames. This smoke alarm does not contain any radioactive material. The smoke alarm is an intelligent security equipment that can be controlled by the Z-Wave network which has particular frequency. Different countries or areas, the radio frequency of the Z-Wave is different. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. In the Z-Wave network communications, the smoke alarm can communicate with other devices associated. When the smoke is detected, the sensor will send messages to the main controller, and then the alarm sound. Through the Z-Wave network, the devices associated can response after smoke is detected, For instance ,Start fire extinguishing equipment and trigger an alarm,Through the Z-Wave network controller, You will be notified in case of fire.
Technical Parameters
Power : DC2*1.5V Alkaline AA battery (Gold Peak Group: GP15A LR6 or
Energizer: E91 or Raymax: LR6)
Operation current : <13uA (Standby current), <90mA (Alarm current) Alarm volume : >85dB(A) at 3 meters. Smoke sensitivity : 0.114-0.167dB/m Silence time: approx10 minutes Heat sensitivity: 54-70Local smoke alarm sound pattern: BI 0.5s - pause 0.5s – BI 0.5s – pause 0.5s – BI
0.5s – pause 1.5s, BI 0.5s - pause 0.5s – BI 0.5s – pause 0.5s – BI 0.5s – pause
4.5s, with the red LED flash, repeat this alarm pattern.
Local heat alarm sound pattern: BI 0.2s - pause 0.1s, with the red LED flash,
repeat this alarm pattern for about 8.5seconds,then pause 4.5 seconds. repeat this alarm pattern.
Comply With: EN14604:2005/AC:2008 Radio Protocol: Z-Wave Radio Frequency: 868.4MHz EU; 908.4MHz US Wireless distance: >50 m in buildings Security: S2_UNAUTHENTICATED
Document NO.: RD-559B-39-001 3 Version: F
Product Configuration Product List:
Smoke Alarm 1pc Bracket 1pc Screw 2pcs Screw stopper 2pcs Instruction 1pc
Wireless function description:
Add(Including) alarm to Z-Wave Network
1:Make sure the battery is installed well before operating the product.
2:Make sure the alarm is on its final install location, then set the controller into the
Add(Inclusion )mode.
3:Quickly, triple click the test button, The LED will light up.
4:Issued beep, LED off, the alarm being Add (included)to the network successfully.
Remove(Excluding) alarm for Z-Wave Network
1: Make sure the battery is installed well before operating the product. 2: Set the Z-Wave Network controller into Remove(exclusion) mode. 3:Quickly, triple click the test button, The LED will light up and alarm enter Remove(Excluding) Mode. 4:Wait for the main controller to Remove(exclusion) the alarm.
Note: If the alarm is Remove(excluded), then the sensor will be itselfrestored to
factory default settings.
Restore the alarm to factory default settings
Reset will delete all information on the Z-Wave network controller, and restore the alarm to factory default settings. 1: Press and hold the test button , Installing the battery, red LED light, until the LED is off, release the button, LED light up again, press the button again, When hearing a beep, restore factory settings successfully. Note: If this sensor is reset, the information of Z-Wave network in the sensor will be deleted. The sensor will be itself restored to factory default settings. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Associations
This has the effect that when the sensor detects the smoke, all devices associated with the sensor will receive the relevant reports and can be controlled by the sensor, e.g. Fire extinguishing equipment, alarm device etc. This device supports five linkage groups: Linkage group 1 is Lifeline.
Document NO.: RD-559B-39-001 4 Version: F
Linkage group 2 is assigned to the devices status - sending BASIC SET control frame to the associated devices having detected the smoke alarm. Linkage group 3 reports the detection's status to the associated device. smoke alarm Linkage group 4 is assigned to the devices status - sending BASIC SET control frame to the associated devices having detected the heat alarm. Linkage group 5 reports the detection's status to the associated device. The alarm will send a “BASIC SET(0xFF)” message to associated group2,4 when pressing test button. to check the function; The alarm will also send a “BASIC SET(0x00)” message to associated group2,4 when quiting the test button. The alarm will also send a “BASIC SET(0xFF)” message to associated group2, when the alarm detects the smoke; and the alarm will also send a “BASIC SET(0x00)” message to associated group2, when the smoke is cleared.The alarm will send a “BASIC SET(0xFF)” message to associated group4, when the heat function is overheat alarm; and the alarm will also send a “BASIC SET(0x00)” message to associated group4, when the overheat alarm is cleared. The maximum number of devices that can be added to the Linkage group 1is 1. The maximum number of devices that can be added to the Linkage group 2,3,4,5 is 4.
Command Classes:
This sensor supports Command Classes as below:
COMMAND_CLASS_ZWAVEPLUS_INFO(V2) COMMAND_CLASS_ASSOCIATION(V2) COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION(V3) COMMAND_CLASS_ASSOCIATION_GRP_INFO(V3) COMMAND_CLASS_VERSION(V2) COMMAND_CLASS_MANUF ACTURER_SPECIFIC(V2) COMMAND_CLASS_DEVICE_RESET_LOCALLY(V1) COMMAND_CLASS_POWERLEVEL(V1) COMMAND_CLASS_BATTERY(V1) COMMAND_CLASS_NOTIFICATION(V8) COMMAND_CLASS_WAKE_UP(V2) S2 supported Command Classes: COMMAND_CLASS_VERSION COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SUPERVISION
Supported Notification Type: Smoke Alarm Smoke AlarmSupportedEvent: 1:Smoke detected,Unknown Location(0x02) 2:SmokeAlarm T est(0x03)