
Technical Data Sheet
øD
ød
f7/h6
H2
H
øZ
e8
G
X
-0,2
H1
HL
AG
3
0
°
6
x
6
0
°
w
øD
ød
f7/h6
H2
H
øZ
e8
G
X
-0,2
H1
HL
AG
3
0
°
6
x
6
0
°
w
L1
øD
ød
f7/h6
H2
H
øZ
e8
G
X
-0,2
H1
HL
AG
3
0
°
6
x
6
0
°
w
L1
Port:
release pressure
see
2
Port:
pressure compensation
see
6
Proximity switch port:1
Signal „Load secured“
see
5
Proximity switch port:2
Signal „unclamped“
see
5
L
1
2
LL
Load direction
Due to tolerances the ports 1 and 2
can be displaced up to +/-4°..
SITEMA - Safety Lock KRGP
Pneumatic actuation
English translation of German original
TI-S12-EN-01/2012
Technical Data Sheet TI-S12
Safety Lock KRGP
For detailed functional description refer to„Technical Information TI-S10“. Furthermore important practical advices are
given in the „Operating Manual BA-S12“.
Fig. 1: Dimensions Safety Lock KRGP
( CAD-Files download at www.sitema.com )
123 4
Type Ident.-No. d M p F6 H D Z X w L1 G T1 AG VL HL H1 H2 Weight
3
mm mm mm kg
KRGP 16
KRGP 22
KRGP 28
KRGP 016 20
KRGP 022 20
KRGP 028 20
mm kN bar kN mm mm mm mm mm mm mm cm
16 5 3,5 - 109 82 35 5 50° 55 M6 15 G1/4 10 19 91 88 1,5
22 10 3,5 3,5 132 102 40 6 40° 60 M6 15 G1/4 15 22 110 115 3
28 20 3,5 11 166 155 50 6 40° 80 M8 20 G1/4 40 43 141 146 8
Subject to modification without prior notice
1 M is the admissible force the mass to be secured exerts on the Safety Lock KRGP.
Against forces in load direction (see Fig. 1) the rod will be totally blo-
cked, the higher the force the stronger the grip. Therefore forces exceeding 2xM may cause damages of the device.
It must be ensured that the dimensions and arrangement of Safety Lock
KRGP in safety-relevant applications meet the requirements of the risk
evaluation (EN 1050) and also comply with any further standards and
regulations applying to the intended use. This is the duty of the system
manufacturer and the user.
2 p is the pressure required to keep released. The permissible working pressure is 10 bar.
3 Regarding safety it is an advantageous feature of the Safety Lock
KRGP, that it normally will not release unless not only pressure is applied but also the load is supported by the lifting drive, thus automatically unintended releasing is prevented.
However, this is only true, if the the load exceeds a minimum limit which
depends on the working air pressure. With for example 6 bar pressure
the critical minimum load is equal to F6. Values for other pressure level
will be given on request.
4 Pneumatic operating volume
5 Proximity switch holders are provided for standard proximity swit-
ches M12x1 shielded and with a nominal switching distance of 2 mm.
For easier service, the proximity switch holders have a positive stop
and are preset when deliverd from the factory..
6 Port T is used for pressure compensation (breathing). It is plugged
with an air filter element. If, however, moisture or aggressive media are
present, a hose instead of the filter must be installed to connect the de-
vice with clean and dry atmosphere.
SITEMA GmbH & Co.KG . Im Mittelfeld 10 . D-76135 Karlsruhe . Phone: +49(0)721/98661-0 . Fax: -11 . www.sitema.com
1/1