Sirius warranty covers only Sirius product. If you choose to install a non-Sirius
branded accessory such as flexible ducting, Sirius will only warrant the hood
and motor. If installation is found to be the cause of failure or issue then charges
will apply for service and parts.
Flexible ducting is not permitted under any circumstances. Flexible ducting has
been found to increase noise levels, increase vibration and reduce airflow.
Sirius Semi-rigid or solid ducting can be used in lieu. There is a range available
to suit any application.
Ducting available at www.siriusbrand.com
A reduction in the duct diameter from stated ducting size will void warranty.
If you are in doubt about the ducting, please contact Sirius on 1300 762 219 prior to installation
The symbol on the product or on its packaging indicates that this product
may not be treated as house-hold waste. Instead it shall be handed
over to the applicable collection point for the recycling of electrical and
electronic equipment. By ensuring this product is disposed of correctly,
you will help prevent potential negative consequences for the environment
and human health, which could otherwise be caused by inappropriate
waste handling of this product. For more detailed information about
recycling of this product, please contact your local city office, your
household waste disposal service or the shop where you purchased the
product. This appliance is marked according to the European directive
2002/96/EC on waste electrical and electronic equipment (WEEE).
2
Page 3
WARNING
Min. 600mm - Max. 650mm for induction cooktops.
Min. 600mm - Max. 750mm gas cooktops.
If the rangehood is positioned above the max height
recommended, warranty may be compromised
as performance of the rangehood will be affected.
Measurement is taken from the top of the trivets to
the underside of the hood. (Fig.1)
600 - 650mm (induction)
600 - 750mm (gas)
600 - 650mm (induction)
600 - 750mm (gas)
flexible cable and plug, or with another device
ensuring omnipolar disconnections from the grid,
with an opening distance between the contacts of at
least 3mm, then such disconnecting devices must be
supplied within the fixed installation.
If the fixed appliance is endowed with a supply cord
and a plug, the appliance has to be put in a place
where the plug can be reached easily.
The use of materials which can burst into flames
should be avoided in close proximity of the appliance.
When frying, please pay particular attention to fire
risk due to oil grease. Being highly flammable, fried
oil is especially dangerous. Do not use uncovered
electric grills. In order to avoid possible fire risk, all
instructions for grease-filter cleaning and for removing
eventual grease deposits should be strictly followed.
SIDE VIEWFRONT VIEW
(Fig. 1)
• The air being drawn can’t be conveyed through
or into a duct used to let out fumes from
appliances fed by energy other than electric
power (eg. centralized heating, radiators, water
heaters, etc.).
• Attention: remove any possible PVC film from the
stainless steel, including the filters.
• To externally vent, please comply with the
pertaining rules given by competent authorities.
• Provide the room with an adequate ventilation
when a rangehood and appliances fed by energy
other than electric power (gas, oil, or coal stoves,
etc.) are used simultaneously. The rangehood,
when evacuating the air, could generate a
negative pressure in the room which can’t exceed
the limit of 0.04 mbar, in order to avoid the
suck of exhausts deriving from the heat source.
Therefore the room should be provided with air
intakes to allow a constant flow of fresh air.
When ducting rangehood to a SEM 1 or SEM 8
motor, options are as follows:
Roof vent - EASYROOF 150T/M
EASYROOF 200T/M
*Kit includes roof flashing
Download installation guide
Eave vent - EASYEAVE 150/200
Download installation guide
Wall vent - EASYWALL 150/200
Download installation guide
Ducting kits are not needed for SEM 2 and SEM 7
motors as not all components are required.
If the rating label in the rangehood shows the symbol
, the appliance is built in class II° and it does not need any earth connection.
If the rating label in the rangehood does not show
the symbol , the appliance is built in class I° and it
needs the earth connection.
When performing the electrical connections on the
appliance, please make sure that the current-tap
is provided with earth connection and that voltage
values correspond to those indicated on the label
placed inside the appliance itself.
Before carrying out any cleaning or maintaining
operations, the appliance needs to be switched off.
If the appliance is not provided with a non-separable
3
Page 4
SL906-L series INSTALLATION OFFBOARD
NOTE
Before installing the appliance, make sure that
none of the parts are damaged in any way. In
case of damaged parts, contact your retailer
and do not proceed with installation. Read all
of the following instructions with care before
installing the appliance.
• Use ducting within the min/max specifications
• Limit the number of ducting bends.
• Do not make any changes in ducting diameter
(recommended constant diameter: Ø 150 mm /
Ø 200 mm or equal surface area).
Before installing the appliance - in order not to
damage the appliance itself - the metal grease filter
should be removed. These filters could be removed
by pushing the handles towards the back side of the
rangehood and pulling it downwards to unfasten it
from its slot. (Fig.2).
To install the appliance please follow these
instructions:
• The appliance must be installed by qualified
technicians, or where possible use a Sirius
recommended installer (see website for details).
In order to avoid damage to the electronic parts
of the appliance, please do not use additional
screws.
• Essential precautions to respect before installing
the appliance are the following:
To have made a cutout on the bottom of the
cabinet which is suitable to hold the appliance in
position (fig. 3):
SL906 EM-L 520 - 501 x 265mm
SL906 EM-L 850 - 835 x 265mm
SL906 EM-L 1000 - 985 x 265mm
SL906 EM-L 1200 - 1100 x 265mm
(Fig.2a)
(Fig.3)
1. Prepare the power supply - 240 volt.
2. Prepare a hole for the ducting - 160 mm or
210mm diameter.
• Maximum length of ducting should not exceed 7
metres to motor.
• (SEM 1 or SEM 8) Additional 5 metres from motor
to atmosphere.
• Do not use screws to fix the outlet pipe to the
rangehoods as they will prevent the movement of
non-return valves.
• Limit the number of elbows in the ducting, since
each elbow reduces the duct efficiency by 1
metre. (i.e. if you use two 90° elbows, the length
of ducting must not exceed 5 metres.)
• Avoid abrupt direction changes.
• Use 150mm constant diameter ducting for the
whole length for the single motor, 200mm ducting
for the twin motor model.
• The use of Sirius ducting will increase the
warranty of the unit to 4 years.
(Fig.2b)
4
Page 5
WARNING
The rangehood is quite heavy, so two people
will be needed for installation.
1. To install the appliance, adjust the position of the
adjustable side-springs using the supplied screws
(fig.4), according to the thickness of the board, in
which the appliance will be fixed.
27mm
(Fig.4)
MAINTENANCE
• Accurate maintenance guarantees good
functioning and long-lasting performance.
• Particular care is due to the grease filter panel. It
can be removed by pushing its handle toward the
back side of the rangehood and pulling the filter
downwards so to unfasten it from its slot (Fig.2).
To insert the filter just perform the opposite
operation.
• After 30 hours of operation, the push button
control panel will flash, signaling the filters are due
for cleaning. Press the timer button to reset.
The grease filter needs cleaning by regular
handwashing or in dishwashers every two
months at least, depending on its use.
• To clean the appliance itself, water and detergent
are recommended, while abrasive products
should be avoided. For steel appliances
specialized detergents are recommended (please
follow the instructions indicated on the product
itself to obtain the desired results).
2. Insert the rangehood into the cutout made in the
cabinet until the stop click of the side-springs is
heard and the rangehood is supported.
3. Insert the screws provided into the holes inside
the rangehood (Fig.5) to fix it to cabinetry.
(Fig.5)
4. Insert the grease channel.
5. Insert the grease filter (Fig.2b)
WARNING
If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similarly qualified person in order to
avoid a hazard.
REPLACING THE LED LIGHT ON THE
SL 906-L
1. Before replacing the LED light, switch off the
rangehood, then - by using appropriate tools remove the LED light from its slot (fig.6).
2. Take out the LED light from its connector and
replace.
• To find the correct LED light, please contact Sirius
directly on our toll-free number: 1300 762 216.
Download motor installation manual at
www.siriusbrand.com for SEM 1, 2, 5, 7, 8
(Fig.6)
• NB: light is easier to remove from centre of
LED globe. Use a small, flathead screwdriver
(pictured), pallette knife or blunt butter knife.
5
Page 6