WARNING
The appliance must be installed and
connected to the power supply only by a
qualified technician.
• There should be adequate ventilation of the room when the rangehood is used at the same time as
appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the
room)
• The details concerning the method and frequency of cleaning
• There is a fire risk if cleaning is not carried out in accordance with the instructions;
• Do not flambé under the range hood;
• CAUTION: Accessible parts may become hot when used with cooking appliances.
Ducting available at www.siriusbrand.com
6 Year Warranty when Sirius Ducting is used. Full replacement warranty on parts and labour.
See website for terms & conditions.
A reduction in the duct diameter from stated ducting size will void warranty.
If you are in doubt about the ducting, please contact Sirius on 1300 762 219 prior to installation
The symbol on the product or on its packaging indicates that this product
may not be treated as house-hold waste. Instead it shall be handed
over to the applicable collection point for the recycling of electrical and
electronic equipment. By ensuring this product is disposed of correctly,
you will help prevent potential negative consequences for the environment
and human health, which could otherwise be caused by inappropriate
waste handling of this product. For more detailed information about
recycling of this product, please contact your local city office, your
household waste disposal service or the shop where you purchased the
product. This appliance is marked according to the European directive
2002/96/EC on waste electrical and electronic equipment (WEEE).
3
Page 4
WARNING
Min. 600mm - Max. 700mm for induction cooktops.
Min. 650mm - Max. 750mm gas cooktops.
If the rangehood is positioned above the max height
recommended, warranty may be compromised
as performance of the rangehood will be affected.
Measurement is taken from the top of the trivets to
the underside of the hood. (Fig.1)
600 - 700mm (induction)
650 - 750mm (gas)
SIDE VIEWFRONT VIEW
• The air being drawn can’t be conveyed through
or into a duct used to let out fumes from
appliances fed by energy other than electric
power (eg. centralized heating, radiators, water
heaters, etc.).
• Attention: remove any possible PVC film from the
stainless steel, including the filters.
• To externally vent, please comply with the
pertaining rules given by competent authorities.
• Provide the room with an adequate ventilation
when a rangehood and appliances fed by energy
other than electric power (gas, oil, or coal stoves,
etc.) are used simultaneously. The rangehood,
when evacuating the air, could generate a
negative pressure in the room which can’t exceed
the limit of 0.04 mbar, in order to avoid the
suck of exhausts deriving from the heat source.
Therefore the room should be provided with air
intakes to allow a constant flow of fresh air.
600 - 700mm (induction)
650 - 750mm (gas)
(Fig. 1)
flexible cable and plug, or with another device
ensuring omnipolar disconnections from the grid,
with an opening distance between the contacts of at
least 3mm, then such disconnecting devices must be
supplied within the fixed installation.
If the fixed appliance is endowed with a supply cord
and a plug, the appliance has to be put in a place
where the plug can be reached easily.
The use of materials which can burst into flames
should be avoided in close proximity of the appliance.
When frying, please pay particular attention to fire
risk due to oil grease. Being highly flammable, fried
oil is especially dangerous. Do not use uncovered
electric grills. In order to avoid possible fire risk, all
instructions for grease-filter cleaning and for removing
eventual grease deposits should be strictly followed.
When ducting rangehood, options are as follows:
Roof vent - EASYROOF 150T/M
EASYROOF 200T/M
*Kit includes roof flashing
Download installation guide
(Fig. 2a)
Eave vent - EASYEAVE 150/200
Download installation guide
If the rating label in the rangehood shows the symbol
, the appliance is built in class II° and it does not need any earth connection.
If the rating label in the rangehood does not show
the symbol , the appliance is built in class I° and it
needs the earth connection.
When performing the electrical connections on the
appliance, please make sure that the current-tap
is provided with earth connection and that voltage
values correspond to those indicated on the label
placed inside the appliance itself.
Before carrying out any cleaning or maintaining
operations, the appliance needs to be switched off.
If the appliance is not provided with a non-separable
(Fig. 2b)
Wall vent - EASYWALL 150/200
Download installation guide
Dome
featured on
200mm kit
only
(Fig. 2c)
For 1500mm versions, a comprehensive list of
300mm components is available at
www.siriusbrand.com or contact nearest retailer.
4
Page 5
SL906 DL series INSTALLATION ONBOARD MOTOR
WARNING: Failure to install the screws or fixing
device in accordance with these instructions
may result in electrical hazards.
NOTE
Before installing the appliance, make sure that
none of the parts are damaged in any way. In
case of damaged parts, contact your retailer
and do not proceed with installation. Read all
of the following instructions with care before
installing the appliance.
• Use ducting within the min/max specifications
• Limit the number of ducting bends.
• Do not make any changes in ducting diameter
(recommended constant diameter:
Ø 150 mm / Ø 200 mm / Ø 300mm or equal
surface area).
To install the appliance please respect the follow
instructions:
• The appliance must be installed by qualified
technicians, or where possible use a Sirius
recommended installer. See siriusbrand.com. In
order to avoid damage to the electronic parts
of the appliance, please do not use additional
screws.
• Essential precautions to respect before installing
the appliance are the following:
To have made a cutout on the bottom of the
cabinet which is suitable to hold the appliance in
position (fig. 4):
SL906 DL 520 - 501 x 265mm
SL906 DL 850 - 835 x 265mm
SL906 DLTM 850 - 835 x 265mm
SL906 DLTM 1000 - 985 x 265mm
SL906 DLTM 1200 - 1100 x 265mm
SL906 DLTM 1500 - 1480 x 364mm
Before installing the appliance - in order not to
damage the appliance itself - the metal grease filter
should be removed. These filters could be removed
by pushing the handles towards the back side of the
rangehood and pulling it downwards to unfasten it
from its slot. (Fig.3).
(Fig.3a)
(Fig.4)
1. Prepare the power supply - 240 volts.
2. Prepare a hole for the exhaust - 160mm diameter
for single motor & 210mm for twin motor versions
and 310mm for triple motor version.
• Do not use screws to fix the ducting to the
rangehoods as they will prevent the movement of
non-return valves.
• Limit the number of elbows in the ducting, since
each elbow reduces the duct efficiency by 1
metre. (i.e. if you use two 90° elbows, the length
of ducting must not exceed 5 metres.)
• Avoid abrupt direction changes.
• Use 150mm constant diameter ducting for the
whole length for the single motor, 200mm ducting
for the twin motor model, and 300mm for triple
motor version.
• The use of Sirius ducting
• will increase the warranty of the unit to 6
years.
(Fig.3b)
5
Page 6
WARNING
The rangehood is quite heavy, so two people
will be needed for installation.
1. To install the appliance, adjust the position of the
adjustable side-springs using the supplied screws
(fig.5), according to the thickness of the board, in
which the appliance will be fixed.
27mm
(Fig.5)
2. Insert the rangehood into the cutout in the
cabinet until the stop click of the side-springs is
heard and the rangehood is supported.
3. Insert the 25mm screws provided into the holes
inside the rangehood (Fig.6) to fix it to cabinetry.
NOTE
To remove the rangehood from the cabinet,
remove the fixing screws (fig. 6) using a
screwdriver, and remove the grease filters
(fig.3).
• Push down on the small handle of the springs,
which are inside the rangehood, with the
necessary strength to unhook the hood from the
cabinet.
4. Insert the grease channel.
5. Insert the grease filter (Fig.3b)
(Fig.6)
CAUTION
Before connecting any ducting to the motor,
make sure the non-return valves - which are on
the air outlet of the motor - can swing open.
External venting
• Connect the flange to the exhaust hole with the
appropriate ducting. Connect the rangehood with
the electrical mains through the supply cord.
Rear vented version
• All the models with one motor can be rear
vented; if the customer wants to use this option,
it is necessary to remove the 18 10mm screws
from the motor group support. Then take the
metal support with motor included out (fig.7a).
Turn the motor to have the air outlet on the rear
side (fig.7b) and fix the 10mm screws previously
removed.
WARNING
If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similarly qualified person in order to
avoid a hazard.
(Fig.7a)(Fig.7b)
6
Page 7
OPERATION
SL906-DL series
A: Light switch on/off
B: Motor switch on speed 1/off - (low/simmer)
C: Motor switch on speed 2 - (general cooking)
D: Motor switch on speed 3 - (high power)
E: Motor switch on speed 4 - (booster)
F: 10 minute shut-off timer
(Fig.8)
MAINTENANCE
• Accurate maintenance guarantees good
functioning and long-lasting performance.
• Particular care is due to the grease filter panel. It
can be removed by pushing its handle toward the
back side of the rangehood and pulling the filter
downwards so to unfasten it from its slot (Fig.3).
To insert the filter just perform the opposite
operation.
• After 30 hours of operation, the button control
panel will flash, signaling the filters are due for
cleaning. Press the timer button to reset.
The grease filter needs cleaning by regular
handwashing or in dishwashers every two
months at least, depending on its use.
Filters may require cleaning sooner if
frequent heavy frying is done.
• To clean the appliance itself, water and detergent
are recommended, while abrasive products
should be avoided. For steel appliances
specialized detergents are recommended (please
follow the instructions indicated on the product
itself to obtain the desired results).
DIMMABLE LIGHT FUNCTION
This function provides for lights dimmability, ranging
from 20% to 100%, by holding down light key on the
remote control or rangehood buttons.
Functions are the following:
- rangehood light off- shortly press the key - light on
at 100%
- light on at 100% - shortly press the key - light off
- light on at 100% - hold down the light button
to reduce brightness.
- releasing the key during reduction, or increase light keeps the luminous intensity reached.
- Light on - dimmed - hold down the light button to
increase brightness.
COLOUR TEMPERATURE SETTING (KELVIN)
Make sure that the lights and the fan are off. Holding
down the TIMER key will turn on the light at the
previously set colour temperature.
Press the TIMER key again. As long as the key
is kept pressed, the colour temperature is changed
from warm to cool, just leave the light key to select
the desired colour. Exit the colour temperature
selection function by pressing the ON/OFF key.
7
Page 8
REPLACING THE LED STRIP ON THE
SL906 DL
1. Before replacing the LED light, switch off the
rangehood, then - by using appropriate tools remove the LED light from its slot. (Fig 9a - b)
2. Take out the LED light from its connector and
replace. (Fig 9c - d)
• To find the correct LED light, please contact Sirius
directly on our toll-free number: 1300 762 216.
• NB: light is easier to remove from the centre of LED strip. Use a small, flathead screwdriver,
pallette knife or blunt butter knife.
(Fig.9a)
(Fig.9b)
(Fig.9c)
(Fig.9d)
8
Page 9
WIRING DIAGRAM SL906 DL (single motor)
9
Page 10
WIRING DIAGRAM SL906 DLTM (twin motor)
10
Page 11
WARRANTY INFORMATION
Dear Customer,
Thank you for choosing this Sirius Rangehood.
We are sure that it will provide you with many years of excellent service. At Arisit Pty Limited we are dedicated to ensuring
that our customers receive the best possible after-sales care.
The Sirius ‘Protection Plan’ has been devised to give you added peace of mind. Should you encounter any problems with your
appliance, our nationwide team of specially trained technicians will deal with your call swiftly and efficiently.
PRIORITY SERVICE, ACCESSORIES & SPARE PARTS
AUSTRALIA
ARISIT PTY LIMITED
40-50 Mark Anthony Drive, Dandenong South,
VIC 3175, Australia
Phone: 1300 762 219
Email: consumer.care@arisit.com
NEW ZEALAND
ARISIT PTY LIMITED
1A Howe Street, Newton,
Auckland 1145, New Zealand
Phone: (09) 306 1020
Email: sales@aristonappliances.co.nz
Warranty
By registering your ownership NOW, you qualify for
Sirius’s Total Peace of Mind Protection Plan.
Australian & New Zealand 3 / 6 Year Protection Plan*
This guarantees your appliance for a full 3 years parts and labour & 10 years for the off-board motors (covering
manufacturing defects only) from the date of purchase, subject to the Terms and Conditions overleaf.
*3 Year warranty is extended to a 6 year period only when Sirius ducting is installed.
Year Warranty
when Sirius ducting is used*
www.siriusbrand.com
11
Page 12
Your Warranty
Register now to qualify.
Terms & Conditions
These Terms and Conditions apply only to
Sirius products distributed in Australia and
New Zealand by Arisit Pty Limited.
1. This warranty applies for a period of 3
years on all products.
a) Warranty is extended to a 6 year
period when Sirius ducting is
installed.
b) All off-board motors are covered
under warranty for a 10 year period
for manufacturing defects only.
2. Warranty applies for parts and labour in
Australia and New Zealand, commencing
from date of purchase.
3. This warranty applies only to the original
purchaser/hire purchaser of this appliance
and cannot be assigned or transferred.
Failure to produce documentary proof
of the date of original acquisition by the
original purchaser will result in a charge
being levied for work done, labour and
parts supplied.
4. This warranty does not apply to:
a) Consumable items such as filters,
fuses, and light bulbs.
b) Damage to body work, paint work,
glass, and plastic items (such as, but
not limited to windows, covers,
baskets, trays, worktops, door
handles, control and kick panels.)
c) Corrosion & rust damage.
A fee may be charged following warranty
claims where no fault is found with the
appliance.
5. This warranty will not apply where:
a) The fault is caused by accident,
misuse, an infestation of insect
and or vermin, fire, flood or the use
of products not approved by Arisit
Pty Limited.
b) There has been a failure to comply
with the manufacturer’s operating
and installation instructions.
c) Service, modification or repair has
been carried out by anybody
other than an approved Arisit Service
Technician.
d) The appliance has been used/
installed anywhere other than a
private dwelling, or where it has been
used other than for domestic use.
e) The appliance is subject to a rental
agreement.
6. Any defective part that has been replaced
becomes the property of Arisit Pty.
Limited.
7. This warranty applies only to Sirius
appliances purchased and installed in
Australia and New Zealand.
8. Loss of use of the appliance or
consequential loss of any nature is not
covered.
9. A charge may be levied at the discretion
of Arisit Pty Limited if the call is deemed
unnecessary or if the cause of failure is
traced to external sourced such as, but
not limited to: blown fused, power failure,
faulty installation, customer misuse or
negligence, etc
10. Where the appliance, the subject of
a warranty claim or repair, is used
or installed more than TWENTY (20)
kilometres from the nearest Arisit Service
Division or Authorised Service Agent, the
cost of delivery to the nearest Service
Division or travel costs for a technician or
Authorised Service Agent shall be for the
account of the Purchaser. Where a built-in
appliance is located or installed outside
the Arisit Authorised Service Agent’s
normal service area, additional travel and
labour costs shall be the account of the
Purchaser.
11. Service is offered during normal business
hours only, also appliances to have a clear
access in a serviceable area
12. Arisit Pty Limited shall not under any
circumstances be responsible in terms of
this warranty for the replacement or repair
of any part of the equipment which may
have been damaged in transit, during and
after installation or imperfections after
installation.
13. Losses caused by act of God, failure to
obtain spare parts, strikes or lockouts are
not covered.
14. External off board motors must be
installed a minimum of 2 metres and
maximum of 7 metres away from the
rangehood. This is for optimum sound
and performance.
15. All motors must be accessible for
servicing purposes and if installed above
2 metres from ground height additional
cost will be incurred due to OH&S
standards for service agents. Prior to
install please check minimum & maximum
installation details on the Sirius website,
FAQ under support tab.
We reserve the right to amend any of the
above without prior notice.
16. This warranty does not affect your
statutory rights.