Nothing from this publication may be copied, translated, reproduced, and/or published by
means of printing, photocopying, or by any other means without the prior written permission
of Siqura.
Siqura reserves the right to modify specifications stated in this manual.
Brand names
Any brand names mentioned in this manual are registered trademarks of their respective
owners.
Liability
Siqura accepts no liability for claims from third parties arising from improper use other than
that stated in this manual.
Although considerable care has been taken to ensure a correct and suitably comprehensive
description of all relevant product components, this manual may nonetheless contain errors
and inaccuracies. We invite you to offer your suggestions and comments by email via
t.writing@tkhsecurity.com. Your feedback will help us to further improve our documentation.
How to contact us
If you have any comments or queries concerning any aspect related to the product, do not
hesitate to contact:
Siqura B.V.
Zuidelijk Halfrond 4
2801 DD Gouda
The Netherlands
1.2 Copyright and trademarks........................................................................................4
1.1Typographical conventions
DANGER!
High level hazard.
Risk of electric shock. Disconnect the power supply before proceeding
with any operation, unless indicated otherwise.
CAUTION!
Medium level hazard.
This operation is very important for the system to function properly.
Please read the procedure described very carefully and carry it out as
instructed.
INFO
Description of system specifications.
We recommend reading this part carefully in order to understand the
subsequent stages.
1.2Copyright and trademarks
The quoted names of products or companies are trademarks or registered trademarks.
4
2Safety rules
CAUTION! The device must be installed only and exclusively by skilled
technical personnel.
CAUTION! The electrical system to which the unit is connected must be
equipped with an automatic bipolar circuit breaker. The circuit breaker
for main supply voltage phase units must have a level of intervention
of 20 A max. The circuit breaker for low voltage units must have a level
of intervention of 6 A max. This circuit breaker must be of the Listed
type. The minimum distance between the contacts must be 3 mm
(0.1 in). The circuit breaker must be provided with protection against
the fault current towards the ground (differential) and the overcurrent
(magnetothermal).
● The manufacturer declines all responsibility for any damage caused by an improper use of
the appliances mentioned in this manual. Furthermore, the manufacturer reserves the
right to modify its contents without any prior notice. The documentation contained in this
manual has been collected with great care. The manufacturer, however, cannot take any
liability for its use. The same thing can be said for any person or company involved in the
creation and production of this manual.
● Before starting any operation, make sure the power supply is disconnected.
● Do not use cables that seem worn or old.
● Never, under any circumstances, make any changes or connections that are not shown in
this handbook. Improper use of the appliance can cause serious hazards, risking the safety
of personnel and of the installation.
● Use only original spare parts. Non-original spare parts could cause fire, electrical discharge
or other hazards.
● Before proceeding with the installation, check the supplied material to make sure it
corresponds to the order specification by examining the identification labels (see "Product
markings" on page 7).
● This device was designed to be permanently installed on a building or on a suitable
structure. The device must be installed permanently before any operation. The altitude of
operation is up to 2000 metres.
● When installing the device, comply with all the national standards.
● Installation category (also called Overvoltage Category) specifies the level of mains
voltage surges that the equipment will be subjected to. The category depends upon the
location of the equipment, and on any external surge protection provided. Equipment in an
industrial environment, directly connected to major feeders/short branch circuits, is
subjected to Installation Category III. If this is the case, a reduction to Installation
Category II is required. This can be achieved by use of an insulating transformer with an
earthed screen between primary and secondary, or by fitting listed Surge Protective
Devices (SPDs) from live to neutral and from neutral to earth. Listed SPDs shall be
designed for repeated limiting of transient voltage surges, suitable rated for operating
voltage and designated as follows: Type 2 (Permanently connected SPDs intended for
installation on the load side of the service equipment overcurrent device); Nominal
Discharge Current (In) 20 kA min. For example: FERRAZ SHAWMUT, STT2240SPG-CN,
STT2BL240SPG-CN rated 120 Vac / 240 Vac, (In=20 kA). Maximum distance between
installation and reduction is 5 m.
● Any device which could be installed inside the product must comply with the current safety
standards.
● If the installation is NEMA TYPE 4X, the installer must replace the cable glands of the
product with NEMA TYPE 4X cable glands.
5
Safety rules
● For all connections, use cables that are able to withstand temperatures of at least 75 °C
(167 °F).
● The product is designed to house only cameras that are properly certified (7 W max).
● A disconnecting device, readily and easily accessible, must be incorporated in the electrical
system of the building for rapid intervention.
● To connect the power supply line use the appropriate junction-box (UPTJBUL). For further
information, refer to the product use and installation manual.
● Use Listed copper tube crimping lugs for the connection of the network conductors to the
terminals. The copper tube crimping lugs must be suitable for the type of installation (from
-20 °C (-4 °F) to +80 °C (+176 °F) min., V-0). Copper tube crimping lugs examples: RP,
BP or YP (Cembre).
6
3Identification
In This Chapter
3.1 Product description and type designation................................................................... 7
This housing has been designed to fit thermal cameras with compact lenses for vision even in
total darkness.
It is possible to use it for a wide range of day/night surveillance systems, such as: monitoring
and rescue in the event of a fire, public safety, along with airport, industrial and
environmental surveillance.
The frontal opening system allows an easy access to the camera and all internal connections.
A wide range of accessories for mounting the equipment is available, thereby satisfying all
installation needs.
3.2Product markings
See the label attached to the product.
7
4Preparing the product for use
Any change that is not expressly approved by the manufacturer will
invalidate the guarantee.
4.3 Disposing of packaging material................................................................................8
4.4 Preparatory work before installation.......................................................................... 9
4.1Unpacking
When the product is delivered, make sure that the package is intact and that there are no
signs that it has been dropped or scratched.
If there are obvious signs of damage, contact the supplier immediately.
Keep the packaging in case you need to send the product for repairs.
4.2Contents
Check the contents to make sure they correspond with the list of materials as below:
● Housing
● Housing equipment:
-Allen wrench
-Spacers
-Cable glands gaskets
-Cable glands (x3)
-Bolts and screws
-Screws for camera
● Instructions manual
● Desiccant bag
4.3Disposing of packaging material
The packaging material can all be recycled. The installer technician will be responsible for
separating the material for disposal, and in any case for compliance with the legislation in
force where the device is to be used.
When returning a faulty product we recommend using the original packaging for shipping.
8
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.