S-60/S-64 E v2 / EVE 2.20
User Manual v8 (181510-8)
AIT55
Nothing from this publication may be copied, translated, reproduced, and/or published by
means of printing, photocopying, or by any other means without the prior written permission
of Siqura.
Siqura reserves the right to modify specifications stated in this manual.
Brand names
Any brand names mentioned in this manual are registered trademarks of their respective
owners.
Liability
Siqura accepts no liability for claims from third parties arising from improper use other than
that stated in this manual.
Although considerable care has been taken to ensure a correct and suitably comprehensive
description of all relevant product components, this manual may nonetheless contain errors
and inaccuracies. We invite you to offer your suggestions and comments by email via
t.writing@siqura.com. Your feedback will help us to further improve our documentation.
How to contact us
If you have any comments or queries concerning any aspect related to the product, do not
hesitate to contact:
Siqura B.V.
Meridiaan 32
2801 DA Gouda
The Netherlands
Index ......................................................................................................54
4
1S-60/S-64 E v2 / EVE Help
What's in this manual
This is version 8 of the user assistance for the S-60/S-64 E v2 and EVE video encoders with
firmware version 2.20. It is made up of the Help topics that you can open from the web
interface of these units. The topics describe:
● How to operate the unit
● How to adjust device settings
● How to manage user accounts
● How to resolve occurred issues
Note: Functions described in this generic Help information may be supported by all encoders
or by specific models only. When describing shared features, this manual uses the generic
term "unit" to refer to the S-60/S-64 E v2 and the EVE encoders. In descriptions of
distinguishing features, the individual product name is used.
Where to find more information
Find product specific datasheets, manuals, EU Declarations of Conformity and firmware
updates at
manual.
Who this manual is for
siqura.com/downloads/software. Make sure that you have the latest version of this
These instructions are for all professionals who will install, operate or maintain this unit.
What you need to know
You will have a better understanding of how this product works if you are familiar with:
● CCTV systems and components
● Ethernet network technologies and Internet Protocol (IP)
● Windows environments and web browsers
● Video, audio, data, and contact closure transmissions
● Video compression methods
Why specifications may change
We are committed to delivering high-quality products and services. The information given in
this manual was current when published. As we continuously seek to improve our products
and user experience, all features and specifications are subject to change without notice.
We like to hear from you!
Customer satisfaction is our first priority. We welcome and value your opinion about our
products and services. Should you detect errors or inaccuracies in this manual, we would be
grateful if you would inform us. We invite you to offer your suggestions and comments via
t.writing@siqura.com. Your feedback helps us to further improve our documentation.
Acknowledgement
This product uses the open-source Free Type font-rendering library. The Open Source
Libraries and Licenses document, available at siqura.com/downloads/software, gives a
complete overview of open source libraries used by our video encoders and IP cameras.
5
2Meet the S-60/64 E v2 family
S-60 E v2
● One-channel H.264 video encoder
● ONVIF Profile S
● Edge recording
● Picture enhancement
● Image quality monitor
● Advanced tamper detection
● 960H Support
● Duplex serial data
● Open Streaming Architecture (OSA)
● Available with SFP interface
● NAS recording
S-64 E v2
● Four-channel H.264 video encoder
● ONVIF Profile S
● Edge recording
● Picture enhancement
● Image quality monitor
● Advanced tamper detection
● 960H Support
● Duplex serial data
● Open Streaming Architecture (OSA)
● Available with SFP interface
● NAS recording
6
3Meet the EVE family
EVE ONE
● One-channel H.264 video encoder
● Click & Go – compact DIN rail mounting
● 2x Digital I/O
● Edge storage on μSDHC card
● Available with Power over Ethernet (PoE)
EVE FOUR
● Four-channel H.264 video encoder
● Click & go: compact DIN rail mounting
● 8x Digital I/O
● 4x Audio in, 1x audio out
● Edge storage on μSDHC card
● Available with Power over Ethernet (PoE)
7
Meet the EVE family
EVE 4x4
● Modular 4x four-channel H.264 encoder
● Edge storage on μSDHC card (4x)
● 4x 4 Audio in; 4x 1 audio out
● 4x 8 Digital I/O
EVE family shared features
● High resolution: 960 H support (960x576 pixels)
● Advanced picture enhancement
● Image quality monitoring
● Tamper detection
● ONVIF Profile S
● NAS recording
8
4Get access to the unit
From a standard browser on your PC, you can connect to the web interface of the unit. Use
the webpages to view live video over the network, remotely operate the PTZ functions, and
configure the settings of the unit. This chapter explains how to open the web interface in your
browser.
In This Chapter
4.1 Get access via web browser..................................................................................... 9
4.2 Get access via Device Manager................................................................................. 9
4.3 Get access via UPnP.............................................................................................. 10
4.4 Log on to the unit................................................................................................. 10
4.1Get access via web browser
Connect to the unit from your web browser
1Open your web browser.
2Type the IP address of the unit in the address bar.
The factory-set IP address of the unit is in the 10.x.x.x range.
3Press ENTER.
The Live Stream page is opened.
- or -
If user accounts exist on the unit, you are directed to the login page (see "Log on to the
unit" on page 10).
4.2Get access via Device Manager
Device Manager is a Windows-based software tool that you can use to manage and configure
our cameras and video encoders. The tool automatically locates these devices on the network
and offers you an intuitive interface to set and manage network settings, configure devices,
show device status, and perform firmware upgrade.
Install Device Manager
1Download the latest version of Device Manager at siqura.com/downloads/software.
2Double-click the setup file.
3Follow the installation steps to install the software.
Connect to the unit via Device Manager
1Start Device Manager
The network is scanned.
Detected devices appear in the List View pane.
2If multiple network adapters exist, select the appropriate adapter to scan the network
that you wish to connect to.
3To perform a manual search, click the Rescan button.
9
Get access to the unit
4.3Get access via UPnP
Universal Plug and Play (UPnP) support is enabled by default on the unit. With the UPnP
service enabled in Windows, you can get access to the unit from Windows Explorer.
Connect to the unit via UPnP
1In Windows Explorer, open the Network folder.
Detected devices in the same subnet as the computer are displayed, including codecs
and cameras with UPnP support.
2Double-click the unit that you want to connect to.
The Live Stream page is opened.
- or -
If user accounts exist on the unit, you are directed to the login page (see "Log on to the
unit" on page 10).
4.4Log on to the unit
By default, users can freely open the web interface of the camera. They are not required to
log on.
User authentication
If user accounts have been created and user authentication is activated, you encounter an
authentication box when you connect. You are prompted to supply your user name and
password. Only users with a valid account can log on.
Log on to the unit
1In User Name, type your user name.
User name and password are case sensitive.
2In Password, type your password.
3Click Log In.
Use strong passwords
CAUTION: MAKE SURE YOU CREATE AN ADMIN ACCOUNT WHEN YOU OPEN THE WEB
INTERFACE FOR THE FIRST TIME. TO KEEP THE ACCOUNT SAFE, SET A STRONG, COMPLEX
PASSWORD. THIS HELPS TO PREVENT UNAUTHORISED ACCESS.
Create a strong password
● Use at least eight characters
● Do not include your real name, user name, company name, or other personal information
● Do not use complete words that can be found in a dictionary
● Use a random combination of at least two of the following categories: upper case letters,
lower case letters, numbers and special characters
Note: For better protection, especially in high-security systems, we advise you to change
the password at regular intervals.
10
5Webpage features
The built-in web interface makes it easy to operate and configure your product over the
network. This section describes the layout and main features shared by the webpages.
Embedded Help
Help topics embedded in the webpages provide context-sensitive user assistance. For
information about items and settings found on a page, click the question mark (Show help) in
the Title bar of the page.
Note: The Embedded Help topics offer generic Help information for a range of Siqura
products. Whether or not a described feature, mode or setting is available on the unit at
hand depends on the model you purchased.
Home page
The Live Stream page is the home page of the unit. It is opened after successfully connecting
to the web interface.
Note: Out of the box, the unit is freely accessible. You are not prompted to log on. To
prevent unauthorised access, we recommend that you implement user authentication. This is
done by creating user accounts and activating user login. For more information, see UserManagement.
Menu
Use the vertical menu on the left to navigate the web interface. Clicking a menu entry opens a
page or a submenu.
Nice to know
To find a specific webpage quickly, type its name in the search-as-you-type box
above the menu.
Layout
Webpages have a single-page layout or content is organised across a number of tabs. A tab
contains related commands and settings. The title of the active tab is highlighted and
underlined.
Previews
Pages such as Live Stream, Overlays, Motion Detection, and Tampering include a camera
preview. You use it to view live video or determine the effect of your settings when you make
changes.
Revert button
A Revert button appears when you adjust specific settings. It lets you undo your changes. The
button is available until you leave the webpage.
Restore the setting to its original state (at the time of opening the webpage).
11
6Live Stream
The Live Stream page is the home page of the unit. This is where you can:
● View and record live video
● Take snapshots
● Control a connected PTZ camera
● Adjust the focus and iris
Layout
The Live Stream page is taken up entirely by the camera preview. On multichannel units,
video from the connected cameras can be viewed in single-view or quad-view mode.
Switch view mode
On multichannel units, the Live Stream page is opened in quad-view mode. You can select a
channel to bring it to the foreground.
1Move your mouse pointer over the previews.
Arrow buttons and option buttons appear.
2Use the Next/Previous buttons to switch channels.
- or -
Click the option button associated with the preview you need.
Show previous/next preview
Show preview associated with selected option button
Toolbar
The toolbar in the upper-right corner has - depending on the selected mode - these buttons.
Hide PTZ controlsShow PTZ controls
Take snapshot
Start recordingStop recording
Full-screenClose full-screen
PTZ controls
In single-view mode, PTZ controls can be displayed in the lower-left corner. This is done by
clicking Show PTZ controls in the toolbar. Note that this button is hidden when PTZ control
is disabled. The function can be enabled on the PTZ page.
12
Live Stream
Important: In the web interface and in this manual, these controls are referred to as "PTZ
controls". Note, however, that a fixed camera connected to the unit does not have pan/tilt
(PT) functionality. The zoom (Z) function is supported though - that is, if PTZ control is
enabled.
Take a snapshot
It is possible to take a snapshot of the video in the preview.
● Click Take snapshot.
The picture is saved in JPG format to the designated folder.
The file name includes the camera name and date/time information.
Record a live stream
A video stream shown in the preview can be recorded and downloaded to your PC.
1Click Start recording.
The button flashes red to show you started a recording.
2To stop the recording, click Stop recording.
The recording is saved in AVI format to the designated folder.
The file name includes date/time information.
Enter full-screen mode
For better observation, you may want to enter full-screen mode.
● Click Full-screen.
The preview fills the entire screen.
Clicking Close full-screen or pressing [Esc] on your keyboard takes you back to standard
mode.
Video streaming
Video streaming can be started and paused with the Play and Pause buttons in the centre of
the preview. These buttons are available when the PTZ controls are hidden.
Play live video stream
Pause live video stream
Pan/Tilt a camera
A PTZ camera connected to the unit can be controlled from the Live Stream page.
1Go to the PTZ page to make sure that PTZ control is enabled for the camera.
2On multichannel units, click the Next/Previous buttons to select the camera you wish
to control.
3In the upper-right corner, click Show PTZ controls.
4To pan/tilt the camera, drag your mouse pointer across the preview in the direction you
need.
Clicking in the preview also moves the camera.
13
Live Stream
Adjust zoom, focus, and iris
To zoom the camera or adjust the focus and iris, use the sliders in the lower-left corner of the
preview. Drag the slider to the left or right and watch the preview until you achieve the
desired effect.
Create a PTZ preset
Camera positions can be stored as PTZ presets.
1Pan, tilt, zoom and focus the camera as needed.
2Click Store current position as preset (the Star button).
The preset is added to the list with a number to identify it.
3Type a descriptive name in the Preset text box.
You can also name and rename presets on the PTZ page.
Recall a PTZ preset
Camera positions stored as PTZ preset can be recalled.
● In the PTZ preset list, click the required preset.
The camera adopts the recorded position.
Delete a PTZ preset
Camera positions stored as a PTZ preset can be deleted when no longer needed.
1In the PTZ preset list, click the preset you want to delete.
2Click Delete preset (the Recycle button).
Note that a deleted preset is irretrievably lost! You are therefore asked to confirm the
deletion.
You can delete multiple presets in one go on the PTZ page.
14
7Camera
On the webpages grouped under Camera, you can adjust the settings for camera
management, image quality, overlays, video streaming and PTZ.
In This Chapter
7.1 Camera Management.............................................................................................15
Note: Available functions and settings on this page vary from model to model.
Name
In Name, type a name for the camera. Use a unique, descriptive name so that you can easily
identify it on the network. The camera name can be enabled as an overlay so that it is visible
in the previews and in video streams transmitted by the camera.
Input
A video input is enabled by default. You can choose to set it to Disabled. This is typically done
when no video signal is connected to an input. If you disable the input:
● No “Video loss”, “Image quality” and “Tamper detect” alarms will be raised.
● The blue screen with “No Video” is not shown when no input signal is connected.
● A black image with reduced frame rate with only the OSD-texts will be streamed.
Aspect ratio
This setting lets you adjust the proportional relationship between the width and the height of
the preview images shown in the web interface.
Input impedance
Impedance is the measure of resistance to signal current flow. With one video source on one
video input, select 75 Ohm. With a number of video inputs in parallel using one video source,
use High-Z on all inputs except the last.
Video standard
The video display standard you select here - PAL, NTSC, or Auto - determines the available
frame rates on the Streaming Profiles page - that is 25 fps for PAL and 30 fps for NTSC.
15
Camera
7.2Image Quality
On the Image Quality page, image quality settings are overlaid over the video in the preview.
Use these settings to enhance the image quality for optimal display in your web browser or in
an application you are using to extract the video stream. Any changes you make are
immediately effective and visible in the preview.
Note: On multichannel units, use the Next/Previous buttons to go to the camera you need,
and then make the required changes.
Noise filter
It is possible to (partially) remove noise from the video signal.
1Click the Noise filter list.
2Select Weak, Average, or Strong as required.
Selecting Off disables the filter.
Auto-enhancement
When set to On, this function continuously analyses the images and dynamically adjusts the
image quality to compensate for changing conditions.
Manual enhancement
Image quality can be controlled manually.
1Set Auto-enhancement to Off.
2While observing the changes in the preview, move the Brightness, Contrast,
Sharpness, Colour saturation, and Hue sliders until you achieve optimal viewing
quality.
Note: With manual enhancement, the settings are not dynamically adjusted when conditions
change.
Brightness
Use this function to adjust the brightness level of the video images to your viewing conditions.
Contrast
Use this function to adjust the contrast level of the video images to your viewing conditions.
Sharpness
Use this function to adjust image sharpness to your viewing conditions.
Color saturation
Use this function to adjust the intensity (purity) of the colours in the video images.
Hue
Use this function to enhance the colours in the video images if they do not look natural.
16
Camera
7.3Overlays
On the Overlays page, text can be superimposed on the video streamed by the unit. You can,
for example, have the camera name, date and time information, measurements or a custom
text displayed. Depending on model, you can also add an image overlay, such as a logo.
Note: On multichannel units, use the Next/Previous buttons to go to the camera you need,
and then make the required changes.
Layout
The greater part of the Overlays page is taken up by the preview. To the right of it, you find
the functions for overlay creation, overlay alignment, font management and image
management.
SectionFunctions
Overlay settings● Add/Modify/Delete text overlays
Overlay alignment● Move overlay to left/right
Font management● Upload/Delete a font
Image management● Upload/Delete an image
● Add/Modify/Delete an image overlay
● Set overlay position
● Set overlay appearance
Toolbar
Overlay toolbar buttons vary from model to model.
ButtonName
Add text overlay
Add image overlay
Add a text overlay
You can add up to three text overlays.
1In the toolbar, click Add text overlay.
A shape with a green border is added to the preview.
2Click the shape to open the shape settings.
3Type your custom text in the text box located in the Selected shape section.
- or -
Click the button to the left of the text box, and then select a predefined entry.
It is possible to reopen the list and click a different entry to append to the selection
already in the text box.
4In the Render mode list, select Outline or Border as needed.
17
Camera
Your adjustment is immediately effective. See the preview for visual feedback.
5Click Position.
6In the Position list, select a preset position.
- or -
Click Free positioning and type custom values in the X position and Y position boxes
to freely place the shape over the video image. Using the options in the Anchor point
list, you can shift the object relative to the anchor point.
You can also position the shape using a drag-and-drop operation.
7(Optional) Use the Rotation angle slider to rotate the text.
8Click Colour.
9Select a font colour and a border colour.
10(Optional) Drag the Transparency slider to set the transparency level of the text.
11Click Font.
12Select the font to be used.
Using the Font management section, you can upload your own fonts to the unit.
13Enter the font size.
As an alternative, you can freely adjust the font size by dragging the resizing handles of
the shape.
Add an image overlay
An image that you have uploaded via Image management can be overlaid on the video.
1In the toolbar, click Add image overlay.
An image shape is added to the preview.
2Click the image to open the shape settings.
3In the Image list, select the image to be used.
4Click Position.
5In the Position list, select one of the preset positions.
- or -
Click Free positioning and type custom values in the X position and Y position boxes
to freely place the shape over the video image. Using the Anchor point setting, you can
shift the shape relative to the anchor point.
You can also position the shape using a drag-and-drop operation.
6Click Advanced.
7(Optional) Drag the Transparency slider to set the transparency level of the image.
8(Optional) Drag the X scale and Y scale sliders to adjust the scaling of the image.
As an alternative, you can freely adjust the scaling by dragging the resizing handles of
the shape.
9(Optional) If your overlay is an animated GIF image, define its speed in Animation
speed.
Delete an overlay
1Click the overlay shape in the preview.
2In the Selected shape section, click the Recycle Bin button.
Upload a font
1Click the arrow which expands Font Management.
2Drag the font file onto the dashed rectangle.
- or -
Use Click to select file to locate and select the file.
3Click Upload.
18
Camera
Delete a font
1Click the arrow which expands Font Management.
2Click Select font to delete.
3Click the font you wish to delete.
4Click Delete.
Upload an image
1Click the arrow which expands Image Management.
2Drag the image file onto the dashed rectangle.
- or -
Use Click to select file to locate and select the file.
The unit supports .GIF and .JPG files.
3Click Upload.
Delete an image
1Click the arrow which expands Image Management.
2Click Select image to delete.
3Click the image you wish to delete.
4Click Delete.
7.4Streaming Profiles
Dual streaming
Per channel, the unit can take the analogue video signal from the connected camera and
convert it into two independent digital video streams with different video encoding settings.
Streaming profile types
A straightforward method of configuring the encoding settings for a video stream is to use a
factory-set streaming profile - that is, a predefined combination of settings for a specific
application. The unit offers profiles optimised for video storage, PTZ, or high-quality live
viewing, for example. If none of the factory profiles meets your requirements you can create
and save user-defined streaming profiles.
Use a factory-set profile
A factory-set streaming profile defines the settings that the unit will use for the application
indicated by the profile name.
1Click the camera name at the top of the webpage.
2Click Stream 1 or Stream 2 to select the stream to assign the streaming profile to.
3In the Profile list (below the Stream tabs), select the factory profile which is
appropriate for (or comes closest to) the intended purpose.
4Repeat steps 1 through 3 for the other stream, if necessary.
Factory profile settings
When you select a factory profile, the video stream will be encoded with the settings shown
below the profile list. For several of these settings, the actual value is shown to the right of
the defined value.
19
Camera
Create a custom profile
If the supplied factory-set profiles do not meet your requirements you can create a custom
streaming profile.
1Click the camera name at the top of the webpage.
2Click Stream 1 or Stream 2, to select the stream to assign the streaming profile to.
3In the Profile list, select the factory profile to be used as a basis for the custom profile.
4Adapt the profile settings to your requirements.
The custom profile is added to the Profile list (User section) as: Factory profile-Copy-yymmdd.
5To rename the profile, type a descriptive name into the Name box.
Delete a custom profile
Custom streaming profiles can be deleted (unlike factory-set profiles).
1In the Profile list, select the profile to be deleted.
2Click Delete.
3In the information bar, click Yes, delete to confirm this action.
Name
Indicates the currently selected streaming profile. You can name and rename custom
streaming profiles. The names of the factory-set profiles cannot be changed.
Encoder type
Depending on the application, select the video encoding method that is to be used to
compress the video signal.
Frame rate
Here you can set the number of video frames per second for the video transmission. Range:
1-25 fps (PAL); 1-30 fps (NTSC).
GOP size
Determines the distance in frames between two I-frames.
Maximum bit rate
Here you can set the maximum bit rate allowed for the video transmission. You can use this
setting to control the network load. The actual bit rate is shown to the right of the text box.
This value is dynamically updated with the current bit rate to provide feedback on the bit rate
that is used on average with the current Maximum quality setting.
Maximum quality
Generally speaking: the higher the Maximum quality setting, the lower the compression ratio
and the more bits are consumed. This means a trade-off has to be found between the desired
quality level and available bandwidth. When configuring these settings it is good to keep the
following in mind.
● If the configured Maximum quality cannot be achieved with the currently set Maximum bit
rate, the actual quality will be lower. The actual quality percentage is shown real-time to
the right of the configured Maximum quality.
● The actual quality level will never exceed the configured Maximum quality, even if the
Maximum bit rate should allow it.
Resolution
Indicates the number of pixels that can be displayed in each dimension (width x height). See
the table below for supported resolutions.
20
Camera
PALNTSC
960H960x576960x480
D1720x576720x480
2/3 D1480x576480x480
1/2 D1352x576352x480
4CIF704x576704x480
2CIF720x288720x240
CIF352x288352x240
QCIF176x144176x120
VGA640x480640x480
QVGA320x240320x240
Traffic shaping
Traffic shaping sets the maximum network bit rate per encoder. Traffic shaping will spread
network traffic bursts which helps the network infrastructure handle the traffic. In its turn,
however, traffic shaping will increase the latency.
● With traffic shaping set to Off, the stream is transmitted with minimum latency but with
bursty network traffic.
● With traffic shaping set to Low, Medium or High, the network traffic is more evenly spread
out in time, but the latency will increase.
Parameter value combinations
When you create a custom streaming profile, set sensible combinations of Frame rate, GOP
size, Maximum bit rate, Maximum long term bit rate, Maximum quality, and Resolution. If in
doubt about the effects of specific encoder settings, you are advised to select the factory-set
profile offering the closest match to your required application.
Use Quad view
To see live video from the S-64 E v2, you can use a web browser or video viewing software.
In a browser, the Live Stream page presents the four camera views arranged in quad layout.
For closer viewing, you can select an individual camera. Likewise, if you use viewing software
to extract video, you can request a quad view RTSP stream or open a separate RTSP stream
per channel. Note that the unit's Quad view function is disabled by default.
1On the Quad view tab, click Enable.
2Configure the encoding settings as needed.
3In your viewing application, specify the URL containing the IP address of the S-64 E v2.
4Add "/quad" after the IP address.
For example: rtsp://10.50.3.72/quad
On successful connection, the S-64 E v2 quad view is streamed to your application.
Tip: Depending on the chosen settings, the overall performance will be reduced when the
quad view stream is enabled. To prevent reduced frame rate or increased latency, it is
recommended to set any unused streams to low resolution and low frame rate.
21
Camera
7.5PTZ
Overview
The PTZ page has the following tabs:
● Camera-#
Use this tab to enable PTZ camera control from your browser, assign an ID to the camera
and manage the PTZ presets you have created on the Live Stream page.
● Driver management
Use this tab to activate PTZ control, upload and delete PTZ drivers, and configure data
settings.
PTZ control
On the Camera-# tab, select/clear the Enable check box to enable/disable PTZ operation from
your web browser.
Camera ID
In order to address multiple cameras on the same RS-485 bus, each camera needs to be
assigned a unique ID. Make sure to set all connected cameras to a different ID on the camera
itself, and then set the camera IDs for all cameras accordingly on this page.
1Click the Camera-# tab.
2In the Camera ID box, type the ID.
Rename a preset
Presets are automatically saved as "PTZ preset #" followed by the preset number. On the
Camera # tab, you can rename a preset to give it a more descriptive name.
1In the Preset name column, click the current name of the preset.
2Type the new preset name.
The preset can now be found under the new name in the Preset list on the Live Stream
page.
Add a reserved preset
Certain functions of a connected camera (such as a wiper/washer system, for example) can be
activated by working with reserved presets, if the camera supports these.
1Click Add Reserved Preset.
A new row is added to the preset table.
2Click the appropriate cell under Preset number and type the number that will activate
the camera function.
3Click the corresponding cell under Preset name and type a descriptive name.
The preset is added to the preset list on the Live Stream page.
Delete PTZ presets
Note that it is not possible to undo the deletion of a preset!
1Click to select the check box(es) of the preset(s) you wish to delete.
2Click Delete preset.
You are asked to confirm the deletion.
Upload a PTZ driver
PTZ drivers not included in the factory-default driver list can be uploaded to the unit.
1On the Driver management tab, click Upload driver.
22
Camera
2Drag the driver file (with .js file extension) onto the dashed rectangle.
3Click Upload.
The driver is added to the User section of the driver list.
Delete a PTZ driver
Uploaded drivers that you no longer need can be deleted. It is not possible to delete the
factory-installed drivers.
1On the Driver management tab, click the list of available drivers.
2Click the driver you wish to delete.
3Click Delete.
PTZ commands over TCP
The unit supports the streaming of PTZ data over TCP using a client/server connection. The
TCP connection is bidirectional.
1In the Listening on port box, specify the port on which the server listens for incoming
TCP connections.
Range: [0 ... 65535]. Default: 1024.
2To activate this function, select Enable.
Bit rate
Determines the speed of the digital transmission - that is, the amount of information
transferred/processed per unit of time.
TX/RX
The TX and RX indicators next to the Bit rate setting are highlighted in green when data is
transmitted (TX) or received (RX) via the serial port.
Word length
Determines the number of bits that is transferred in a single operation.
Stop bits
Indicates the end of a data character to enable the receiver to resynchronise with the stream.
Parity mode
Enables the sending of an extra bit with each data character for error detection purposes.
Wire mode
The RX-4xx interface type on the data connector is set in software. Select the required type in
the Wire mode list.
Biasing
If biasing is needed, it should be enabled on at least one module on the bus.
Termination
Normally, the devices at the two extremes of a bus are terminated, while intermediate devices
are not. Therefore: RS-422, always enable (being point-to-point); RS-485, enable only for the
first and last module connected to the bus configuration.
23
Camera
7.6Privacy Mask
To avoid intrusive monitoring, privacy masks can be used to conceal sensitive areas within the
field of view of a camera.
Add a privacy mask
You can create up to ten privacy masks.
1In the upper-right corner, click Add privacy mask.
The mask appears as an overlay.
2Drag the mask to the area that you want to conceal.
3Drag the sides of the mask to resize it.
It is recommended to set the mask to twice the size of the sensitive area.
4In the Colour list (lower-left corner), select a colour for the mask.
Delete a privacy mask
1Click on the mask to select it.
2In the upper-right corner, click the Recycling button (Delete privacy mask).
24
8Event
On the Event pages, you can define how the unit is to handle incoming events.
On the Event Management page, you can link actions to specific events. Once the event
occurs, it triggers the selected action automatically.
Add an event
The Event Management page is blank when you open it for the first time. You can add events
by selecting a trigger and linking an action to it.
1Click Add event.
2In the Trigger column, click Select trigger.
3In the Trigger list, select the event that will set off the trigger action.
4In the Action column, click the corresponding cell.
5In the Action list, select the action to be taken when the event occurs.
The event is effective as soon as you have defined the trigger and the action.
Note: Make sure that the FTP server settings are configured correctly when you select "FTP
image ..." as a trigger action.
Delete an event
1Select the check box of the event you wish to delete.
2Click Delete event.
8.2Connection Monitor
The Connection Monitor function can monitor the network connection between the unit and a
target host on the network. The unit pings the remote machine - that is, sends data packets
to it, at intervals of 15 seconds to determine if the remote machine is accessible and
responding.
Edge recording
To prevent loss of video when the connection to a central network video recorder or VMS
system is lost, recorded video clips can be stored on the microSD card inside the edge device.
From the Edge Recording page, the clips can then be downloaded for further processing.
25
Event
Steps
Setting up the unit to record video to the SD card when a ping request times out without a
response involves the following steps:
● On the Recording page, check the SD card status.
● On the Event Management page, add a "Connection # lost" trigger and link a "Start
recording of Camera #" action.
● On the Connection Monitor page, set up and enable the Connection Monitor to monitor the
connection to the VMS/NVR.
Set up the connection monitor
1In IP address, type the IP address of the remote machine that is to be pinged.
2Click Enable to activate the monitor.
The connectivity status is given as "Connection present" or "Connection lost".
"Connection present" indicates that the remote machine responds to the ping
requests.
"Connection lost" indicates a network failure.
Connection loss
Detection of a connection loss to a device at a monitored IP address triggers the following:
● Edge recording starts at the first lost ping.
Important: Recording does not start if the device at the specified IP address has not
been detected previously. In other words, recording is only possible for devices which
have acknowledged their presence on the network at least once by responding to ping
messages. This is to prevent unintended recording to the microSD card.
● The connection loss is reported in the Connection Monitor page: "Connection lost".
● The associated video clip appears in the Available clips section on the Edge Recording page
with clip status shown as 'Recording'.
● Edge recording continues until the device becomes responsive to ping messages again that is, on the next received ping.
8.3Digital I/O
The number of digital I/O channels that is provided depends on the model of your encoder
(see the table below). Each of the I/O pins can function as a digital input or a digital output
(but not simultaneously).
ProductDigital I/O channels
EVE ONE2
EVE FOUR8
EVE 4x44x8
S-60 E v24
S-64 E v28
On the Digital I/O page, you can set the mode for each pin.
1In the Mode column, click the required cell.
2Select the desired mode.
26
Event
ModeDescription
Force closedI/O contact is closed
InputI/O pin is input pin
Output (inverted)I/O pin is output pin (output inverted)
OutputI/O pin is output pin
On the Event Management page, you can add events triggered by "I/O # closed" and define
actions to be taken when such events occur.
8.4FTP Push
On the Event Management page, events can be set to trigger an FTP push. When such an
event occurs, the unit posts a camera image on one or two FTP servers. A target server must
hold a user account associated with the unit. If you assign two servers, images are posted
simultaneously to FTP server 1 and FTP server 2.
Set up the FTP server connection
1Select the Enable check box of Send to this server.
2In IP address, type the IP address of the FTP server you want to use.
3In Port, type the port number to be used.
The FTP protocol typically uses port 21 on the FTP server to listen for clients initiating a
connection. Port 21 is also where the server is listening for commands issued to it.
4In Name, type the user name that is needed for authentication before you can access
the server.
5In Password, type the password that is needed for authentication before you can
access the server.
6(Optional) Repeat steps 1-5 for the second FTP server.
On the Camera-# tab, you can set the path to an FTP server and configure settings for
continuous posting.
Server path
In the Server path box, type the name of the folder on the FTP server which is assigned to the
FTP client. Example: \Captures\Cam-1. This can be used if the client is not allowed to access
the server root folder.
Click Test FTP settings to make sure that the server path has been set correctly. A message
in the top of the screen will indicate if the camera has been able to make a connection with
the FTP server or not.
Continuous posting
Image upload to an FTP server can be event-triggered but you can also set it to be
continuous.
1In Interval, type a value to determine the interval between two image posts.
2In File name, type a descriptive name or accept the default name.
With the append button you can add extra information to the file name.
3To activate continuous posting, select Enable.
27
9Recording
The unit provides edge recording. This function makes it possible to record and store video
locally - that is, at the unit itself. Recorded video clips are stored on the microSD card inside
the unit. From the Edge Recording page, the clips can be downloaded for further processing.
9.3 NAS recording...................................................................................................... 30
9.1Camera-#
Record
Use the stream list at the top of the page to select Stream 1 or Stream 2 for recording.
Recording types
Two types of edge recording are available:
● Continuous recording
● Event-triggered recording
Recording source
Each camera input has multiple streams. In the Recording source list, select the stream to
be recorded.
Recording destination
Recordings can be stored either on an SD card or a configured NAS server. In the Recording
destination list, select the desired storage medium.
Continuous recording
Selecting Enable activates continuous recording of the chosen video stream to the microSD
card. Recording continues until you clear the check box to disable the function.
Important: Be aware that recording in continuous mode for extended periods of time will
wear out the flash memory of your microSD card prematurely.
Event-triggered recording
Unlike 24-hour recording by an NVR or VMS, event-triggered recordings are typically short
recordings. Start and stop times for the recordings are triggered by specific external events.
On the Event Management page, you can link a "Start recording" action to triggers such as:
● a lost connection to an NVR or VMS
● camera tampering
● a closed I/O contact
● motion detection
● image quality issues
28
Recording
● signal loss
● audio level rising above a threshold
Note: If you set connection loss as a trigger you also need to set up the Connection Monitor
to monitor the connection.
Persistent recording
Recording to the microSD card is persistent. This means that powering the unit off and on
does not erase the existing recordings on the microSD card. Be aware, though, that the oldest
recordings will be overwritten by new recordings when the card is 90% full.
Available clips
Details about clips can be found in the Available clips section.
● Clips with recording status 'Recording' or 'Ready' are available for download in .avi format.
● Clips include 30 seconds of prerecorded video and five seconds of postrecorded video. The
prerecording mechanism is active at all times.
● Clip file size will not exceed 500 MB. If a recording requires more storage capacity,
multiple clips are created.
Download a clip
1In the Available clips section, click the clip's Ready or Recording status indication.
The file is saved to the designated folder on your PC.
2In the information bar, click Open or Show in folder.
Clip names are created automatically using UTC date/time information.
Note: Downloading a clip to your PC does not remove the clip from the microSD card. You
can delete clips manually on the Edge Recording page (see below).
Delete a clip
1In the Available clips section, select the clip by clicking the check box.
2Click Delete selected clip.
9.2SD Card
microSD card
The unit supports µSDHC and XC cards with a maximum capacity of 32 GB. You can check the
card storage capacity and available space through the SD card tab on the Edge Recording
page. When the SD card is 90% full, new recordings will overwrite the oldest recordings.
Format the SD card
1Click Format SD card.
2To confirm, click Yes, format.
The existing data on the SD card is erased.
The unit reboots.
Maximum retention period
Indicates how long recordings will be stored on the SD card. If you set the maximum
retention period to, for instance, 1 week, all recordings older than 1 week will automatically
be deleted.
29
Recording
SD card usage
We advise to use high-grade, highly-durable microSD cards. Note that microSD cards are
limited to the number of write cycles ranging from 200 (off-the-shelf TLC NAND) to 100.000
(4 GB industrial SLC NAND). Intensive usage will eventually wear out the card.
The number of write cycles times the capacity of the microSD card gives you the total amount
of data that can be written to the card in its life time. A 32 GB microSDHC with 2000 write
cycles, for example, can write 64 TB before it should be replaced.
Card status
Indicates the status of the SD card. Possible statuses are:
● Not present
No SD card is found.
● Not recognized
The SD card found is not recognized by the camera.
● OK
The SD card is present and recognized.
● Error
There is an unknown error with the SD card.
● Formatting
The SD card is currently being formatted.
● Retrieving
The SD card is currently being retrieved.
Card size
Indicates the total storage capacity of the SD card. The diagram indicates how much of the
storage capacity is currently in use.
9.3NAS recording
The unit supports NAS (Network Attached Storage) using the SMB/CIFS or NFS protocol.
Use NAS client
To activate the NAS client, select Enable.
9.3.1Server settings
Type
In the Type list, select the protocol to be used for NAS storage: either SMB/CIFS (also known
as SAMBA or Windows file sharing) or NFS.
Address
In the Address box, type the host name or the API address of the NAS server. Examples:
● 1.2.3.4
● storage-1.example.net
30
Recording
Path
In the Path box, type the name of the folder where the unit should store its recording data.
For SMB/CIFS, the path always starts with the share name, followed by the directory in the
share. Example: camera/camera0016.
User name
In the User name box, type the user name to be used to connect to the NAS server (only
applicable for SMB/CIFS).
Password
In the Password box, type the password to be used to connect to the NAS server (only
applicable for SMB/CIFS).
Bit rate limiting
If the unit is connected to a network with limited bandwidth, it is recommended to limit the
bandwidth for communication to and from the NAS. This is to make sure that enough
bandwidth remains available for other data, for example video streams.
Select the Enable check box to limit the bandwidth.
Bit rate limit
In the Bit rate limit box, type the number of kilobits per second to which you wish to limit
the bandwidth for communication to and from the NAS.
Apply server settings
Click Apply server settings to apply all server settings at once.
Status
Indicates the status of the NAS server.
Storage size
Indicates the total storage capacity of the NAS server. The diagram indicates how much of the
storage capacity is currently in use.
Maximum retention period
Indicates how long recordings will be stored. If you set the maximum retention period to, for
instance, 1 week, all recordings older than 1 week will automatically be deleted.
31
10Device
Users with an Administrator or Operator account can access the Device pages to configure the
device, network, date and time, security, and SNMP settings. Administrators can also manage
user accounts.
On the Device Management page, you can restart the unit, reset it to the factory-default
settings, create and restore backup files, and upgrade the firmware.
Name
Type a descriptive name in the Name box. This makes identification of the unit easier when
you scan the network in Device Manager. The unit must be restarted for the change to take
effect.
Description
Defines the device type.
Article code
Administrative information for article identification.
Serial number
Uniquely identifies the unit. You may be asked to provide this number when you contact our
technical support.
Firmware version
Indicates the currently active firmware version.
Uptime
The time elapsed since the camera system became operational.
Firmware upgrade
The unit has two firmware storage areas: a fixed image area and an upgrade image area. The
fixed image area contains the original factory version of the firmware. This cannot be erased.
The upgrade image area is usually empty upon factory release.
32
Device
Using the Firmware upgrade section you can write a new firmware version to the upgrade
image area. An upgrade image can replace an existing upgrade image written to the unit at an
earlier upgrade.
Important: It is essential that the upgrade image is compatible with the unit.
1To open the upgrade section, click Firmware upgrade.
2Drag the firmware file (sqrfw extension) onto the dashed rectangle.
- or -
Use click Click to select file to locate and select the file.
3Click Upgrade.
The firmware is upgraded. The unit is unresponsive for 30 seconds.
Restart the unit
The Restart button restarts the unit without resetting variables. During the restart the unit is
unresponsive for 30 seconds.
Reset to factory defaults
With the options accessed via the Reset to factory defaults button, you can reset all variables
that can be set by the user. After clicking either of the options the unit restarts and is
unresponsive for 30 seconds.
● If you need to keep the current network configuration, click Keep network settings.
● If you want a complete reset which restores all device settings, including the IP address
and subnet mask, to their original, default values, click Discard network settings.
Warning: "Discard network settings" restores the unit to the factory-set IP address. This
could make the unit unreachable for in-band communications. In that case the webpages
are accessible only by moving a PC to the same subnet as the unit.
Create a backup file
It is possible to back up the settings of the unit, so that you can restore them if a problem
should occur.
1Click Create backup file.
The backup file is saved to the designated folder on your PC.
File name convention: yymmdd-backup.tar
2Store the file in a safe location (designated for backups, for example).
Restore a backup
You can restore a backed-up configuration.
1To open the upgrade screen, click Restore previously created backup.
2Click Do not restore network settings from backup if you want to preserve the
current network settings.
3Drag the backup file ( with .tar extension) onto the dashed rectangle.
4Click Restore.
The unit becomes unresponsive for some 30 seconds while the backup is restored.
10.2Network
For correct functioning of the unit, its network settings must be compatible with the network
to which it is added. On the Network page, you can set a static IP address or enable DHCP to
have an IP address assigned dynamically.
33
Device
Important: On the S-64 E v2, DHCP is disabled by default. The unit is initially accessible
through the factory-set IP address which can be found on a sticker on the unit. This is also
the IP address to which the unit reverts when you reset it to the factory-defaults discarding
the network settings. On EVE encoders, DHCP is enabled by default.
After you make changes on this page, the unit must be restarted for the changes to take
effect. While restarting, the unit is unresponsive for 30 seconds.
Host name
Identifies the unit on the network. You can set the host name on the Device Management
page.
HTTP port
The port used for connections over HTTP. Default: port 80.
HTTPS port
The port used for secure communication over the network. Default: port 443.
Use DHCP
By default, DHCP is enabled. With DHCP enabled, the unit dynamically requests an IP address
and other networking parameters from a DHCP server on the network. There are two possible
outcomes.
● A DHCP server is found and an IP address is assigned from its pool of addresses.
The unit can then be found with Device Manager - a software tool available for download
at siqura.com/downloads/software. You can use this tool to connect to the web interface of
the unit.
● No DHCP server is found.
The unit then reverts to its factory-set IP address. This is the same IP address as that
found on the sticker on the housing of the camera. To get access to the web interface,
take the following steps:
1. Set the network adapter of a browsing PC to the factory-default subnet of the unit.
2. Connect the unit to the PC.
3. From a browser on the PC, open the web interface of the unit and go to the Network
page.
4. Configure the network settings as needed.
It is also possible to request a time server address via DHCP. You can activate this function on
the Date & Time page.
MTU size
This value is set to 1500 (Ethernet) by default. Maximum Transmission Unit (MTU) is the
maximum size (in bytes) of an IP packet that can be transmitted over the network without
dividing it into pieces. You can use the (default) values on the list or type a custom value. An
MTU size that you specify here must be supported on the other side of the link.
Use a static IP address
Instead of using an IP address assigned by DHCP you can set a static IP address.
1Clear the DHCP check box.
2Type the new network settings in the appropriate boxes.
34
Device
IP address
The factory-set IP address of the unit is in the 10.x.x.x range with a 255.0.0.0 subnet mask.
Achieving initial communication with the unit requires that the network adapter of the
browsing PC is set to the factory-default subnet of the unit. Having made the web interface
accessible in this way, you can use the Network page to change the default network settings
to the desired settings.
For IP address input to be valid, the IP address of the unit:
● must be within the 10.0.0.1 ~ 223.255.255.254 range.
● cannot start with 127 (reserved for loopback on local host).
Subnet mask
Used to subdivide the IP network for security or performance purposes.
Default gateway
The IP address of the network node (router) which serves as the entry point and exit point to
the network.
Preferred DNS
The IP address of the DNS server that will be used first for DNS name resolution.
Alternate DNS
The IP address of the server which will be used as the secondary DNS server.
Services
On the Services tab of the Network page, you can enable or disable the unit's RTSP, ONVIF,
MX, and UPnP services as needed. For more information, see the service descriptions below.
RTSP
The unit implements an RTSP server. A hardware or software decoder (the latter within a
viewing application, for example) is the RTSP client. Media sessions between client and server
are established and controlled with RTSP. Media stream delivery itself is handled by the RealTime Transport Protocol (RTP). Select the RTSP check box to enable RTSP streaming.
RTSP port
The port number used for RTSP media sessions. Default port: 554.
ONVIF
Enables the ONVIF service on the unit. The ONVIF specification ensures interoperability
between products regardless of manufacturer. It defines a common protocol for the exchange
of information between network video devices including automatic device discovery and video
streaming. The unit fully supports the ONVIF standard. It has been tested to support ONVIF
Profile S.
ONVIF Discovery
Makes the unit discoverable for ONVIF clients. Clear this check box if you prefer to disable
discovery. In that case, the unit can still be controlled from ONVIF clients that "know" of its
existence.
MX
Select this check box if you need to establish MX connections. MX/IP is a proprietary UDP
protocol used to communicate with Siqura equipment over a network connection.
35
Device
UPnP
If enabled, UPnP (Universal Plug and Play) allows the unit to advertise its presence and
services to control points on the network. A control point can be a network device with
embedded UPnP, a VMS application or a spy software tool, such as Device Spy. With the UPnP
service enabled in Windows, you can connect to the unit from Windows Explorer.
10.3Date & Time
The date and time on S-6x E v2 units can be set manually or you can use a time server. The
S-6x E v2 encoders have a battery-supported real-time clock. When you reboot this unit, the
correct date and time information is retained. EVE encoders do not include a battery. They
need to be connected to a time server.
Manual date and time setting
1Clear the Use time server check box.
2Click the Date & Time button.
3Make your adjustments in the Date and Time boxes.
Format
The date and time are displayed in fixed format in the web interface - that is, yyyy-mm-dd and
hh:mm:ss. On the Overlays page, you can select an alternative format for text overlays.
Time zone
Set the local zone depending on the physical location of the unit.
Adjust automatically for DST
The unit can adjust the time automatically for daylight saving time (DST).
1Select Adjust automatically for DST.
2Use To daylight saving time and To standard time to set the appropriate start and
end details.
The unit will automatically adjust at the given dates and times.
The table below gives DST change information. Note that these dates and times are
subject to change. Refer to http://www.timeanddate.com/time/dst or similar websites
for current information.
DST beginsDST ends
Australia2:00 AM local time, first Sunday in
October
ChinaN/AN/A
Europe2:00 AM local time, last Sunday in
March
RussiaN/AN/A
USA2:00 AM local time, second Sunday
in March
3:00 AM local time, first Sunday in
April
3:00 AM local time, last Sunday in
October
2:00 AM local time, first Sunday in
November
36
Device
Use a time server
We strongly recommend that you use a time server. Without a time server, the real-time
clock will deviate from the actual time after a few days. There are two options for specifying
which time server is to be used.
● The time server IP address can be obtained via DHCP.
● The time server IP address can be set manually. This can be the address of an NTP server
or that of a Video Management System (VMS) with time server functionality, such as VDG
Sense
Obtain time server from DHCP
It is possible to have the IP address of a time server included in the settings received through
DHCP. Using this function requires that DHCP is enabled on the Network page (see
"Network" on page 33).
Note: Since DHCP is disabled by default on the S-64 E v2, the Obtain time server from
DHCP functionis also disabled by default.
Time server address
Here you can set the address of a time server.
1To activate this function, clear the Obtain time server from DHCP check box.
2In the Time server address box, type the IP address or the name of the time server.
Identifying the time server through its name requires the presence of a DNS server to
translate the name into an IP address. The DNS server IP address can be included in the
DHCP settings or you can set it on the Network page (see "Network" on page 33).
Time service query interval
Indicates the time interval, in minutes, used by the camera to retrieve the current time from
the time server.
10.4Security
Via the Security page, Administrators can install security certificates to enable secure
connections between the unit and web browsers. It is also possible to activate authentication
for users who want to start an RTSP video stream or extract JPEG snapshot images.
Authentication for camera viewing
This function is disabled by default. Users can freely connect to the unit over RTSP and extract
a video stream that it is generating. This may be undesirable from a security perspective.
Therefore, it is possible to restrict access to the unit to users with a valid account.
Administrators can create and delete user accounts via User Management.
● Select Enable.
On attempting to open an RTSP connection, users are now asked to provide a user name
and password.
Secure connections
With HTTPS implemented and activated, a safe exchange of data between the unit and a web
browser is ensured. Information transported over the network - for example, device settings
and user credentials - is encrypted to protect it against intrusions and infections that can
compromise the security and privacy of the information.
37
Device
Certificates
To implement HTTPS on the unit, you need to install an HTTPS certificate. You can use a selfsigned certificate or one created by a Certificate Authority (CA). CA-issued certificates provide
a higher level of security and inspire more trust than self-signed certificates. Self-signed
certificates are often installed for test purposes or as a temporary solution until a CA-issued
certificate has been obtained.
Certificate information
The following information must be provided to create a certificate.
ItemDescription
CountryThe country where the certificate is to be used
Country codeTwo-letter country code
Days until expirationThe valid period (in days) of the certificate. Default: 365
State/ProvinceThe administrative region in which the organisation is located
Common nameThe name of the entity to be certified by the certificate
CityCity where the organisation is based
EmailThe contact email address
OrganisationThe name of the organisation which owns the entity specified in
the "Common name" box
Organisation unitThe name of the organisational unit which owns the entity
specified in the "Common name" box
Important: Make sure that the Common name that you specify matches the URL that is
used to access the webpages of the unit. Generally, this is its IP address.
Install a self-signed certificate
1Enter the required information as described above.
2Click Create self-signed certificate.
The certificate is created and installed.
Install a CA-issued certificate
1Enter the required information as described above.
2Click CA created certificate.
3Click Create and download certificate request.
4Go to your download folder, copy the certificate_request.csr file, and then send it
to a CA.
Once you have received the signed certificate from the CA:
5Click CA created certificate.
6Click Upload certificate.
7Drag the certificate file onto the dashed rectangle.
8Click Upload.
Open a secure connection
With a security certificate installed, you can establish a secure connection.
1Click Self-signed certificate or CA created certificate (depending on the type you
want to use).
2At the top of the page, activate HTTPS by selecting Certificate required.
38
Device
3Refresh the page.
4Log on to the unit.
Your browser is now using a secure connection to communicate with the unit.
10.5User Management
Initial setup
Out of the box, the unit is freely accessible - that is, when you connect to the web server you
are not prompted to log on. To prevent unauthorised access, we recommend that you
implement user authentication. This is done by creating user accounts and activating user
login. The number of user accounts you can create is virtually unlimited.
Roles
The unit supports three account types with associated access levels.
AccountPage accessPermissions
ViewerLive Stream onlyView live video, PTZ control
OperatorAll pages except User
Management
AdminFull accessFull control
Configure, manage and operate the unit.
User management not allowed.
Use strong passwords
CAUTION: MAKE SURE YOU CREATE AN ADMIN ACCOUNT WHEN YOU OPEN THE WEB
INTERFACE FOR THE FIRST TIME. TO KEEP THE ACCOUNT SAFE, SET A STRONG, COMPLEX
PASSWORD. THIS HELPS TO PREVENT UNAUTHORISED ACCESS.
Create a strong password
● Use at least eight characters
● Do not include your real name, user name, company name, or other personal information
● Do not use complete words that can be found in a dictionary
● Use a random combination of at least two of the following categories: upper case letters,
lower case letters, numbers and special characters
Note: For better protection, especially in high-security systems, we advise you to change
the password at regular intervals.
Add a user
Before you can add users and activate user login you must create an Admin account.
1Click Add user.
2Click Enter user name.
3Type the user name.
User names and passwords are case sensitive.
4Click Enter password.
5Type the password.
6Repeat steps 1-5 as needed and select the role which is applicable.
7(Optional) Refresh the page to sort the user list by name.
39
Device
Activate user authentication
Once you have an Admin account, you can activate user authentication for the unit.
● On the User Management page, click Activate user login.
Users will now be prompted to supply their user name and password when they connect to
the unit.
Edit a user
Admins can change user passwords and assign new roles.
1Click the Password box.
2Type a new password.
3Click the Role box.
4Select a new role.
The user name cannot be modified.
Delete a user
Admins can delete user accounts.
1Click the check box of the user you wish to delete.
2Click Delete user.
3In the information bar, click Yes, delete.
10.6SNMP
The Simple Network Management Protocol (SNMP) can be used to monitor the unit for
conditions or events which require administrative attention. Via SNMP, several status variables
can be read and traps can be generated on events.
The SNMP Agent is MIB-2 compliant and supports versions 1 and 2c of the SNMP protocol.
Note: The unit includes SNMP support for its Image Quality monitor and Tamper Detect
functions. A trap is sent when bad image quality or camera tampering is detected and
another one when the situation returns to normal.
Required MIB files can be downloaded at siqura.com/downloads/software.
System information
This section shows the network/device data specifically made available to the SNMP manager
for making the device, its location and service manager(s) traceable.
1In the Contact box, type the name of the service manager.
2In the Node name box, type the host name of the unit.
3In the Location box, type the name of the physical location of the unit.
Communities
The community strings (names which can be regarded as passwords) in the Communities
section must conform to those configured in the SNMP manager. Often, these are 'public',
mainly used for the read and trap communities, and 'private' or 'netman', for read-write
operations. The manager program may offer additional choices.
40
Device
Traps
An alarm status change in the unit generates a trap which can be caught by any SNMP
manager. The unit can, for example, send traps on the occurrence of Image Quality and
Camera Tampering events. Variables, which can be read from the unit's MIB through an SNMP
manager, indicate why the alarm occurred. The OPTC-VCA-MIB required for this can be
downloaded, together with the other MIBs for the unit, at siqura.com/downloads/software.
1In the Version list, click the SNMP version used.
2In the IP Address box, type the IP address associated with the manager program.
3In the Port box, type the destination port number.
Default: 162.
Note: Version, IP Address, and Port are required fields.
4In the Alternate IP Address box, if desired, type an alternative destination IP address.
5In the Alternate Port box, if desired, type an alternative destination port number.
6If desired, select Enable to activate Authentication trap.
This adds an authentication trap to catch attempts at access using the wrong community
string.
41
11Diagnostics
The Logging page can assist you when you need to troubleshoot encountered issues.
The unit includes logging functionality which can be used for diagnostic purposes.
Download a log file
To view the logfile of the unit, you need to download it to your computer.
1Click Download log file.
2In your download folder, click system.log.
The file is opened in Notepad.
Use a syslog server
Syslog is a standard which allows devices to send event notification messages over IP
networks to event message collectors, also known as syslog servers.
1In the Syslog server IP address box, type the IP address of the syslog server you will
2To activate Send log to syslog server, select Enable.
11.2LED
To identify the unit you can make the status LED blink for a selectable time span.
Start blinking
1Click to open the Start blinking LED list.
2Click a time span.
Stop blinking
1Click to open the Start blinking LED list.
2Click Stop blinking LED.
be using.
42
12Analytics
Siqura video encoders include video analytics which can monitor the video images and raise
an alert when the following events occur:
● The image quality becomes too poor.
● The camera's position or field of view has changed.
● Movement is detected in a predefined area of the image.
Motion detection enables the user to define a portion of the screen and to detect picture
changes there. These changes could be caused by motion or varying lighting, for example.
Set up motion detection
The Motion Detection function enables the unit to trigger an alarm when motion in a specified
area of the field of view - that is, the Region of Interest (ROI), reaches or exceeds a
configured sensitivity threshold value.
1In the upper-right corner, click Activate Motion Detection.
The button turns green and the Draw ROI button appears.
Drawing a ROI is optional. If you do not need a ROI, proceed to step 4. In that case, the
entire field of view becomes the ROI.
2Click Draw ROI.
3Drag the mouse pointer across the preview to draw the Region of Interest (ROI).
If the ROI is not the correct size or in the wrong place you can repeat steps 2 and 3.
4Drag the Alarm level slider to set the sensitivity of the detection.
Local change is only detected if its level exceeds the defined value (indicated by the red
horizontal line). The Alarm level setting can be used to eliminate unwanted ('false')
triggering (for example, caused by background noise or constant local movement). You
may need to try out several alarm levels to achieve the best detection.
5If required, go to the Event Management page and add an event with motion detection
as an event trigger.
Deactivate motion detection
You can (temporarily) deactivate motion detection.
● Click Deactivate Motion Detection.
The Motion Detection button turns red and the ROI is hidden. Clicking the button once
again reactivates motion detection using the same ROI.
43
Analytics
12.2Tampering
As a result of tampering, or more accidentally, after cleaning, a camera may no longer cover
the area designated for monitoring. The Tampering function can detect camera position
changes and scene changes such as a blocked camera view. It does so by comparing the
current image to one or more reference images that were captured and stored earlier.
Set up tamper detection (EVE encoders)
Tamper detection needs a reference image for comparison with the current image.
1Click Activate Tamper Detection.
The button turns green and reference image learning starts. Progress is indicated by a
progress bar.
Once created, the reference image is displayed as an overlay over the current image.
Detection starts immediately.
When the camera scene or position is changed, a warning is displayed: "Camera hasbeen tampered with!!!".
2If required, go to the Events Management page, add an event with a "Camera #
tampering detected" trigger, and then define the subsequent action.
3To delete the current reference image, click Deactivate Tamper Detection.
Clicking Activate Tamper Detection once more will create a new reference image.
Set up tamper detection (S-60/S-64 E v2)
The Tamper Detection function enables the unit to trigger an alarm when camera position
changes or scene changes are detected in a specified area of the field of view, that is, the
Region of Interest ROI). Tamper detection needs a reference image for comparison with the
current image.
1Click Activate Tamper Detection.
The button turns green and additional buttons appear.
2If the selected camera is a PTZ camera, click Select to open the PTZ preset list in the
lower-left corner, and then click the PTZ preset for which you want to create a reference
image.
Drawing a ROI is optional. If you do not need a ROI, proceed to step 5. In that case, the
entire field of view becomes the ROI.
3Click Draw ROI.
4Drag the mouse pointer across the preview to draw the Region of Interest (ROI).
This defines the area which will be monitored for changes.
5Click Add reference image.
The reference image is created. Progress is indicated by a progress bar.
Once created, the reference image appears as an overlay with a green border.
6Click Show reference images.
7Click the new reference image, type a name in the Name box, and then close the
dialogue box.
8To create more reference images, repeat steps 2-7 as needed.
Detection starts immediately.
When the camera scene or position is changed, a warning is displayed: "Camera hasbeen tampered with!!!" and the reference image border goes from green to red.
9If required, go to the Events Management page (see "Event" on page 25), add an event
with a "Camera # tampering detected" trigger, and then define the subsequent action.
10To delete a reference image, click Show reference images, point to the image to be
deleted, and then click the Recycle button.
44
Analytics
12.3Quality Monitor
The Quality Monitor can detect if images produced by the camera are still usable. Four
coloured dials give an indication of the performance of the camera and show whether or not it
needs attention. A quality check is made against what is normally a good picture.
Examples of detectable occurrences
● The camera is in focus during sunny days, but out of focus in low light situations.
● The initial daytime camera position seemed OK, but streetlights and spot lights affect the
image during nighttime.
● The lens has got dirty.
● The iris control has got stuck.
● Camera failure occurs.
Measurements
The Quality Monitor can measure the contrast level, exposure, SNR (Signal-to-Noise Ratio)
and picture detail. The four measurements are enabled by default. The camera health is being
measured continuously.
StateDescription
Error state
Hysteresis: the area where the alarm output is either
"true" or "false" depending on the preceding alarm state
Correct performance
On the Event Management page, you can add events triggered by various image quality
states, such as "... image too bright", "... contrast too low", or "... detail too low", and then
define actions to be taken when a specific state occurs.
45
13Advanced
The Advanced menu gives access to the Direct Streaming, Data, and Audio (if supported)
pages.
Important: We recommend that you have in-depth understanding of the Advanced settings
and their values before you make any changes. If in doubt, do not change the default
values.
In This Chapter
13.1 Direct Streaming.................................................................................................46
On the Direct Streaming page you can enter IP settings for direct streaming to a unicast or
multicast IP address.
Multicast
The unit supports IP multicast. This is a method for 'one-to-many' real-time communication
over an IP network. The technique can be used to send media streams from an IP camera or a
video encoder to a group of interested receivers in a single transmission. The intermediary
network switches and routers replicate the data packets to reach the multiple receivers on the
network. The switches and other network devices used must be carefully configured for, and
capable of handling multicasting and its associated protocols (most notably IGMP).
SAP
The unit includes a SAP announcer. The Session Announcement Protocol (SAP) is used to
advertise that a media stream generated by the unit is available at a specific multicast
address and port. SAP listening applications can listen to the announcements and use the
information to construct a guide of all advertised sessions. This guide can be used to select
and start a particular session. The SAP announcer is not aware of the presence or absence of
SAP listeners.
1In IP address, type the multicast destination IP address for the announcements and
media streams.
Range: 224.2.128.0 ~ 224.2.255.255.
2In Port, type the destination port number.
Default: 1024. Use even numbers only.
3Select Enable.
Session announcements and media streams will now be sent to the given IP address.
The media stream can be identified through the Program name which is made up of the
camera name and stream number.
46
Advanced
Direct Streaming
The unit supports direct media streaming to a multicast or unicast IP address (a decoder or
viewing application, for example).
1In IP address, type the destination IP address.
2In Port, type the destination port number.
Default: 50010. Use even numbers only.
3Select Enable.
Audio and data streaming
Per camera, you can set up direct streaming of audio and data (if supported by the unit).
Specify the appropriate destination/source IP addresses and port numbers, and then select
Enable to activate Direct Streaming.
Quad view
On the Quad view tab of the S-64 E v2, you can configure settings for Quad view streaming
using RTSP Multicast or Direct Streaming. Note that Audio, Data, and SAP settings are not
available. For more information about Quad view streaming, see also Camera > Streaming
Profiles > Quad view.
13.2Data
PTZ commands over TCP
The unit supports the streaming of PTZ data over TCP using a client/server connection. The
TCP connection is bidirectional.
1In the Listening on port box, specify the port on which the server listens for incoming
TCP connections.
Range: [0 ... 65535]. Default: 1024.
2To activate this function, select Enable.
Bit rate
Determines the speed of the digital transmission - that is, the amount of information
transferred/processed per unit of time.
TX/RX
The TX and RX indicators next to the Bit rate setting are highlighted in green when data is
transmitted (TX) or received (RX) via the serial port.
Word length
Determines the number of bits that is transferred in a single operation.
Stop bits
Indicates the end of a data character to enable the receiver to resynchronise with the stream.
Parity mode
Enables the sending of an extra bit with each data character for error detection purposes.
Wire mode
The RX-4xx interface type on the data connector is set in software. Select the required type in
the Wire mode list.
47
Advanced
Biasing
If biasing is needed, it should be enabled on at least one module on the bus.
Termination
Normally, the devices at the two extremes of a bus are terminated, while intermediate devices
are not. Therefore: RS-422, always enable (being point-to-point); RS-485, enable only for the
first and last module connected to the bus configuration.
Cause:Obtain Time server from DHCP is enabled, but on the Network page DHCP is
disabled.
Solution: Open the Network page and enable DHCP or set the Time server address
manually on the Date & Time page.
Cause: The Time server address is set manually but the address cannot be reached.
Solution: Verify the Time server address. If the address is specified as a name, a DNSserver must be available. Open the Network page and check the Preferred DNS and
Alternate DNS addresses.
14.2FTP issues
Unable to upload to FTP server
Cause: The FTP server does not hold a user account associated with your encoder.
Solution: Request a user account from the FTP server.
14.3Logon issues
Unable to log on
Cause: Incorrect user name or password. User name and password are case sensitive.
Solution: Supply correct user name and password.
49
Troubleshooting
Cause: Unknown user.
Solution: Request Administrator to create a user account.
Use the reset button
If you have forgotten your Admin password or are otherwise locked out of your video encoder
you can regain access by using the reset button on the front panel of the unit.
1Insert a straightened paper clip into the reset button hole which is located:
- to the left of the VIDEO IN BNC connector (EVE ONE).
- below the Digital I/O connector (EVE FOUR).
- to the right of the Digital I/O connector (EVE 4x4).
- to the left of the Digital I/O connector (S-60/S-64 E v2).
2Keep the reset button depressed for at least three seconds.
This erases the upgrade firmware (if present) in the upgrade image area.
The unit will revert to its factory-set network settings.
3Use the IP address found on the sticker on the unit to access the webpages.
14.4Network issues
No network connection between the unit and the browsing PC
Cause: Physical network issue(s).
Solution: Verify that all network devices are properly connected and powered up. Follow the
cables, make sure they are plugged into the correct connectors, and check every connector
thoroughly.
Cause: Network configuration issue(s). To establish an IP connection, the unit and the
browsing PC must be on the same subnet. EVE encoders request an IP address via DHCP by
default. If no server is found, the unit reverts to its factory-set IP address in the 10.x.x.x
range. On S-64 E v2 units, DHCP is disabled by default.
Solution: Install Device Manager (available for download at siqura.com/downloads/software)
on the browsing PC. Scan the network with Device Manager. If the unit is not detected, set
the network adapter of the PC to the factory-set subnet of the unit. The IP address is printed
on a sticker on the unit. Use Device Manager or a browser to access the unit from the PC, and
then modify its network configuration as needed.
Cause: Security issue(s). The connection is blocked by a firewall.
Solution: Check if there is a firewall on the PC or on the network which is blocking the
connection. Contact your system or network administrator for assistance, if necessary.
14.5PTZ issues
No PTZ control from Live Stream page
Cause: The connected camera has no PTZ functionality.
Solution: Connect a PTZ camera.
Cause: The active PTZ driver is not compatible with the connected camera.
Solution: On the PTZ page, select a driver which is supported by the camera. Required
drivers can be uploaded to your video encoder if necessary.
50
Troubleshooting
14.6Upgrade issues
Successful upgrades are reported as "Successfully upgraded to version ...". In the event of an
unsuccessful upgrade, the following error messages may help you pinpoint the cause of the
problem.
Upgrade procedure already in progress
Cause: The unit received multiple upgrade requests at approximately the same time.
However, only one request can be handled at a time. The later request receives this error
message.
Solution: Issue one upgrade request at a time and wait for the unit to respond.
Invalid firmware file
Cause: The unit performs a number of checks to determine the validity of the file. If it finds
problems with the file, such as the file not being a firmware file with .sqrfw extension, it
displays this error message.
Solution: Use a firmware file with .sqrfw extension.
Device hardware is incompatible
Cause: If the image identifier of the hardware does not match the image identifier of the
firmware file, this error message indicates that the selected firmware file is not intended for
the unit. In that case, the upgrade procedure is terminated. The fixed image and the upgrade
image stay in the memory of the unit. After a reboot, the unit runs the same image as
before the reboot.
Solution: Use a firmware file which is compatible with the unit.
Firmware file is corrupt
Cause: The firmware file contains a CRC error. When this error occurs, the unit reboots
automatically and restarts with the fixed image.
Solution: Download and install usable firmware.
Rule validation failed
Cause: The firmware file is not suitable for this particular device.
Solution: Upgrade with firmware intended for this unit.
Failed to write firmware to flash
Cause: The firmware file is streamed directly into flash. Various errors may occur while
writing the firmware to flash. There may be connection loss, for example, or a reboot during
the upgrade procedure. If any such error occurs, the unit reboots automatically and restarts
with the fixed image.
Solution: Prevent a loss of connection or a reboot during the upgrade procedure. Do not
leave the Device Management page or close your browser.
14.7Video issues
Frames are being dropped
Cause: On multichannel units, the four encoders can simultaneously handle video encoding at
full frame rate at 960H resolution. It is not recommended, however, to generate eight video
streams at 960H. This may overtax the hardware and lead to frames being dropped.
51
Troubleshooting
Solution: Set a lower resolution for one or more video streams and disable the quad view
stream if not needed.
Frame rate drops
Cause: On multichannel units, the four encoders can simultaneously handle video encoding at
full frame rate at 960H resolution. It is not recommended, however, to generate eight video
streams at 960H. This may overtax the hardware and lead to drops in frame rate (see the
actual frame rate measurement).
Solution: Set a lower resolution for one or more video streams and disable the quad view
stream if not needed.
Corrupted video stream, visible smears or stuttering video
Cause: Not all data is received by the receiver due to network congestion.
Solution: Make sure there is enough bandwidth available in the network for the stream to be
transported from the camera or encoder to the receiver. You can also reduce any overload
caused by peak traffic from the encoder. To do this, set the Traffic Shaping to a higher value.
See Camera > Streaming Profiles > Stream > Traffic shaping.
14.8Webpage issues
The built-in webpages are displayed incorrectly in your web browser
Cause: The unit supports only recent web browser versions.
Solution: Only use the latest two versions of Chrome, Firefox, Internet Explorer or Safari.
Cause: JavaScript is not enabled in your web browser.
Solution: Open the Privacy (or Security settings) of your web browser and enable JavaScript
(Active scripting).
52
Acknowledgements
Our units use the following Open Source Components / Libraries:
Component/LibraryURL
● Linux Kernel 2.6 - licensed under the GNU
General Public License (GPL), version 2
● alsa-lib - licensed under the GNU Lesser Public
License (LGPL), version 2.1
● alsa-utils – licensed under the GNU General
Public License (GPL), version 2
● boost - Boost Software License, Version 1.0http://boost.org/
● BusyBox - licensed under the GNU General
Public License (GPL), version 2
● ethtool – licensed under the GNU General
Public License (GPL), version 2
● freetype - Copyright 1996-2002, 2006 David