![](/html/85/8594/85941659671067ef56ad708ee8ed58d1453a3273c042f0ae104a81033cc34b79/bg1.png)
EX Fixed Series
Ex d 316L Fixed camera station
Installation Manual
![](/html/85/8594/85941659671067ef56ad708ee8ed58d1453a3273c042f0ae104a81033cc34b79/bg2.png)
Note: To ensure proper operation, please read this manual thoroughly before using the
product and retain the information for future reference.
Copyright © 2017 Siqura B.V.
All rights reserved.
EX Fixed
Installation Manual v4 (151111-4)
AIT55
Nothing from this publication may be copied, translated, reproduced, and/or published by
means of printing, photocopying, or by any other means without the prior written permission
of Siqura.
Siqura reserves the right to modify specifications stated in this manual.
Brand names
Any brand names mentioned in this manual are registered trademarks of their respective
owners.
Liability
Siqura accepts no liability for claims from third parties arising from improper use other than
that stated in this manual.
Although considerable care has been taken to ensure a correct and suitably comprehensive
description of all relevant product components, this manual may nonetheless contain errors
and inaccuracies. We invite you to offer your suggestions and comments by email via
t.writing@tkhsecurity.com. Your feedback will help us to further improve our documentation.
How to contact us
If you have any comments or queries concerning any aspect related to the product, do not
hesitate to contact:
Siqura B.V.
Zuidelijk Halfrond 4
2801 DD Gouda
The Netherlands
General : +31 182 592 333
Fax : +31 182 592 123
E-mail : sales.nl@tkhsecurity.com
WWW : http://www.tkhsecurity.com
2
![](/html/85/8594/85941659671067ef56ad708ee8ed58d1453a3273c042f0ae104a81033cc34b79/bg3.png)
1 EX Fixed Series - Installation Manual
Preserve this manual as a reference for future needs.
Used electrical, electronic and stainless steel products should not be mixed with
general waste. For proper treatment, recovery and recycling of old products,
take them to applicable collection points, in accordance with your national
legislation and the Directives 2002/95/EC and 2002/96/EC.
By disposing of these products correctly, you help to save valuable resources
and prevent any potential negative effects on human health and the
environment which could otherwise arise from inappropriate waste handling.
For more information about collection and recycling of old products, contact
your local municipality or your waste disposal service. Penalties may be
applicable for incorrect disposal of this waste, in accordance with national
legislation.
The manufacturer declines all liability for any consequence resulting from improper installation
practices, tampering or improper uses of the product.
The descriptions and illustrations contained in this manual are not binding. The manufacturer
reserves the right to make any alterations deemed appropriate for the technical,
manufacturing and commercial improvement of the product, while leaving the essential
product features unchanged, at any time and without undertaking to update the present
publication.
The manufacturer declines all responsibility for any consequences resulting from improper use
of the product, or use which is different from that expected and specified in the present
documents.
In This Chapter
1.1 Description............................................................................................................ 3
1.2 Before you continue................................................................................................ 4
1.3 Install the unit........................................................................................................5
1.4 Maintain the unit.................................................................................................... 8
1.5 Technical data........................................................................................................9
1.6 Dimensions.......................................................................................................... 10
1.1 Description
The EX Fixed Series includes a full range of stainless steel fixed camera stations specifically
designed for Hazardous Area applications. The design of the housings ensures the best
protection from external agents along with easy installation and maintenance service. EX
Fixed camera stations are equipped with the latest generation zoom module day/night and
thermal imaging cameras. They are also available for customer-specified cameras.
The EX Fixed Series units have been designed and certified to the ATEX Directive 2014/34/EU
to the following:
II 2 G Ex db op pr IIC T6 Gb T
II 2 D Ex tb IIIC T85 °C Db IP66/IP67
-40 °C to +60 °C
amb
3
![](/html/85/8594/85941659671067ef56ad708ee8ed58d1453a3273c042f0ae104a81033cc34b79/bg4.png)
EX Fixed Series - Installation Manual
This product is designed for use with flammable gases and vapours covered by apparatus
groups IIA, IIB and IIC with temperature classes T1 to T6 and with flammable dust covered
by apparatus groups IIIA, IIIB and IIIC with temperature T=85 °C. The surface temperature
class of the device was determined only with ambient air temperature, without taking into
consideration direct sunlight.
This product must only be installed by suitably trained personnel in accordance with the
relevant code of practice (e.g., EN60079-14). These instructions are intended for their sole
use.
CAUTION: It is recommended to use proper certified cable glands and connection cables.
1.2 Before you continue
● Prior to installation and operation, carefully read all instructions in this manual
and heed all warnings.
● Unpack this equipment and handle it carefully. If the package appears to be
damaged, notify the shipper immediately.
● Use the original packaging to transport the unit. Disconnect power supply
before moving it. In case of returning the equipment, the original packaging
must be used.
● Any change performed on the unit that is not previously approved by the
manufacturer will void both the certification and the warranty.
● Trying to manually force the wiper will result in damaging the device and will
void the warranty.
● Fasteners used for the assembly shall be M5-08x12 grade A4-70.
● WARNING: The device is equipped with remotely controlled moving parts.
● All the electrical connections should be realised in a non-explosive
atmosphere.
● Before performing any operation, turn off the power. The installation of the
unit can be performed only by qualified personnel in accordance with the
relevant code of practice (e.g., EN60079-14) and with all the relevant local
and national standards including but not limited to the use of special pipes,
tapes, sealants, cables and glands.
● When leaving the unit unused for long periods, disconnect supply cables.
● The internal transformer of the unit should never be used to power external
devices.
● Make sure that the unit case is properly earthed, connecting all the earth
ground studs. Earth cable should be about 10 mm longer than the other
cables on the connector, in such way that it will not be accidentally
disconnected if the cable is stretched or pulled.
● No ventilation is needed for the unit, as it is completely sealed.
● When a fibre optical cable is used on the equipment it shall be suitably
protected against mechanical damage external to the equipment (wire
armoured cable, fitted in conduit, within a cable tray, etc.).
● The camera must be installed so that the risk of impact with the glass window
is low.
4