Siqura C-60 E-MC, C620 E, s-68 e User Manual

User Manual
Firmware Version 4.14
H.264 Multicodec Video Encoder
Page 2
Note: To ensure proper operation, please read this manual thoroughly before using the product and retain the
information for future reference.
Copyright © 2014 Siqura B.V.
All rights reserved.
C-60 E-MC v4.14 User Manual v7 (092606-7) AIT55MW10
Nothing from this publication may be copied, translated, reproduced, and/or published by means of printing, photocopying, or by any other means without the prior written permission of Siqura.
Siqura reserves the right to modify specifications stated in this manual.
Brand names
Any brand names mentioned in this manual are registered trademarks of their respective owners.
Liability
Siqura accepts no liability for claims from third parties arising from improper use other than that stated in this manual.
Although considerable care has been taken to ensure a correct and suitably comprehensive description of all relevant product components, this manual may nonetheless contain errors and inaccuracies. We invite you to offer your suggestions and comments by email via t.writing@tkhsecurity.com. Your feedback will help us to further improve our documentation.
How to contact us
If you have any comments or queries concerning any aspect related to the product, do not hesitate to contact:
Siqura B.V. Zuidelijk Halfrond 4 2801 DD Gouda The Netherlands
General : +31 182 592 333 Fax : +31 182 592 123 E-mail : sales.nl@tkhsecurity.com WWW : www.siqura.com
Page 3
Contents
1 ABOUT THIS MANUAL .............................................................................................................................. 9
2 SAFETY AND COMPLIANCE ..................................................................................................................... 11
2.1 SAFETY .................................................................................................................................................... 11
2.2 DECLARATION OF CONFORMITY .................................................................................................................... 14
3 PRODUCT OVERVIEW ............................................................................................................................. 15
3.1 FEATURES ................................................................................................................................................ 15
3.2 MODELS .................................................................................................................................................. 15
3.3 DESCRIPTION ............................................................................................................................................ 16
3.4 FRONT PANEL ........................................................................................................................................... 17
4 INSTALL THE UNIT .................................................................................................................................. 19
4.1 POWER THE UNIT ....................................................................................................................................... 19
4.2 CONNECT CABLES ...................................................................................................................................... 19
4.3 STARTUP .................................................................................................................................................. 20
4.4 CONNECTOR PIN ASSIGNMENTS .................................................................................................................... 20
4.5 UPDATE DEVICE DEFINITIONS ....................................................................................................................... 21
5 CONNECT THE UNIT ............................................................................................................................... 23
5.1 ESTABLISH A NETWORK CONNECTION ............................................................................................................. 23
5.2 ESTABLISH VIDEO AND OTHER SIGNAL CONNECTIONS ......................................................................................... 25
5.2.1 Port numbers .................................................................................................................................... 26
6 INTERFACES ........................................................................................................................................... 27
6.1 ONVIF .................................................................................................................................................... 27
6.2 OSA ....................................................................................................................................................... 27
6.3 WEB UI ................................................................................................................................................... 27
6.4 MX/IP .................................................................................................................................................... 28
6.5 SNMP .................................................................................................................................................... 28
6.6 SAP ........................................................................................................................................................ 28
6.7 NTCIP .................................................................................................................................................... 28
7 STREAM MEDIA VIA RTSP ...................................................................................................................... 31
7.1 RTSP AND RTP......................................................................................................................................... 31
7.2 TRANSFER VIA UDP OR TCP ........................................................................................................................ 32
8 ACCESS THE WEBPAGES ......................................................................................................................... 33
8.1 SYSTEM REQUIREMENTS .............................................................................................................................. 33
8.2 CONNECT VIA WEB BROWSER ....................................................................................................................... 33
8.3 FIND THE UNIT WITH SIQURA DEVICE MANAGER .............................................................................................. 33
8.4 CONNECT VIA UPNP .................................................................................................................................. 35
8.5 LOG ON TO THE UNIT .................................................................................................................................. 35
9 NAVIGATE THE WEBPAGES .................................................................................................................... 37
9.1 MENU ..................................................................................................................................................... 37
9.2 ACCESS CONTROL ...................................................................................................................................... 38
9.3 WEBPAGE ELEMENTS .................................................................................................................................. 38
10 VIEW LIVE VIDEO VIA BROWSER ............................................................................................................ 39
10.1 ACTIVATE LIVE VIEW .................................................................................................................................. 39
Contents
Page 4
10.2 VIEW LIVE VIDEO ....................................................................................................................................... 40
10.3 USE YOUR BROWSER FOR PTZ CONTROL ......................................................................................................... 41
11 STATUS .................................................................................................................................................. 43
11.1 VIEW STATUS INFORMATION ........................................................................................................................ 43
11.1.1 Stream states ............................................................................................................................... 43
11.2 VIEW MEASUREMENTS DATA ........................................................................................................................ 44
11.2.1 General, network, and stream measurements ............................................................................ 44
11.2.2 FTP Push ....................................................................................................................................... 44
12 NETWORK .............................................................................................................................................. 45
12.1 NETWORK SETTINGS ................................................................................................................................... 45
12.2 ADVANCED ............................................................................................................................................... 46
12.2.1 Services ........................................................................................................................................ 46
12.2.2 Network ....................................................................................................................................... 46
13 VIDEO .................................................................................................................................................... 47
13.1 VIDEO ENCODING OVERVIEW ....................................................................................................................... 48
13.2 GENERAL ................................................................................................................................................. 49
13.2.1 Video Settings .............................................................................................................................. 49
13.2.2 Encoder Priorities ......................................................................................................................... 50
13.3 ENCODER # .............................................................................................................................................. 51
13.3.1 Encoder Settings .......................................................................................................................... 51
13.3.2 Combinations of settings ............................................................................................................. 53
13.3.3 Notes ............................................................................................................................................ 54
13.3.4 Make a video connection ............................................................................................................. 54
13.3.5 Advanced ..................................................................................................................................... 56
13.3.6 Encoder ........................................................................................................................................ 56
13.3.7 Stream Manager .......................................................................................................................... 59
13.3.8 Transmitter # ............................................................................................................................... 60
13.3.9 RTSP Transmitter ......................................................................................................................... 61
13.3.10 SAP Settings ................................................................................................................................. 62
13.3.11 Meta data insertion ..................................................................................................................... 64
13.3.12 Notes ............................................................................................................................................ 66
13.4 H.264 - 1 ................................................................................................................................................ 68
13.4.1 Encoder Settings .......................................................................................................................... 68
13.4.2 Constant Quality Mode configuration ......................................................................................... 70
13.4.3 Profiles ......................................................................................................................................... 70
13.4.4 Parameter value combinations .................................................................................................... 71
13.4.5 MX Transmitter Settings and making video connections ............................................................. 71
13.4.6 Advanced ..................................................................................................................................... 72
13.4.6.1 Encoder ................................................................................................................................................... 72
13.4.6.2 Stream Manager, Transmitter #, RTSP Transmitter, and SAP .................................................................. 73
13.5 LIVE VIEW ................................................................................................................................................ 74
13.5.1 (M)JPEG output ............................................................................................................................ 74
13.5.2 Encoder Settings .......................................................................................................................... 74
13.5.3 Advanced ..................................................................................................................................... 75
13.6 OSD ....................................................................................................................................................... 76
13.6.1 OSD facilities ................................................................................................................................ 76
13.6.2 Text Settings................................................................................................................................. 76
13.6.3 Text # ........................................................................................................................................... 77
13.6.3.1 Advanced ................................................................................................................................................. 78
13.6.4 Graphics ....................................................................................................................................... 79
13.6.4.1 Advanced ................................................................................................................................................. 80
13.7 VMD ...................................................................................................................................................... 81
Contents
Page 5
13.7.1 VMD startup................................................................................................................................. 81
13.7.2 Configure detection parameters .................................................................................................. 82
13.7.3 Set the mask ................................................................................................................................. 83
13.7.4 VMD detection window ............................................................................................................... 84
13.7.5 VMD alarm ................................................................................................................................... 84
13.7.6 Advanced ..................................................................................................................................... 84
13.8 FTP PUSH ................................................................................................................................................ 86
13.8.1 Post JPEG images ......................................................................................................................... 86
13.8.2 General......................................................................................................................................... 86
13.8.3 FTP server ..................................................................................................................................... 87
13.8.4 Event management ...................................................................................................................... 88
13.8.5 Monitor and troubleshoot FTP Push ............................................................................................ 88
13.9 IMAGE MONITOR ...................................................................................................................................... 89
13.9.1 Image quality check ..................................................................................................................... 89
13.9.2 Enable the Image Monitor ........................................................................................................... 90
13.9.3 Dial legend ................................................................................................................................... 91
13.9.4 Measurements configuration....................................................................................................... 93
13.9.5 Region of Interest (ROI) ................................................................................................................ 94
13.10 TAMPER DETECT ................................................................................................................................... 96
13.10.1 Camera movement and scene changes ....................................................................................... 96
13.10.2 Enable Tamper Detect .................................................................................................................. 96
13.10.3 Reference images ......................................................................................................................... 97
13.10.3.1 Create a reference image ................................................................................................................... 97
13.10.3.2 Mask the ROI ...................................................................................................................................... 98
13.10.3.3 Compare images ................................................................................................................................. 98
13.10.3.4 Delete a reference image ................................................................................................................... 99
13.10.4 Position measurement ................................................................................................................. 99
13.10.5 Alarms ........................................................................................................................................ 100
13.10.5.1 Alarm examples ................................................................................................................................ 101
13.11 PRIVACY MASK ................................................................................................................................... 102
14 AUDIO .................................................................................................................................................. 103
14.1 ENABLE AUDIO ........................................................................................................................................ 103
14.1.1 Input Settings ............................................................................................................................. 104
14.1.2 Output Settings .......................................................................................................................... 104
14.2 MAKE AUDIO CONNECTIONS ...................................................................................................................... 105
14.2.1 MX Transmitter Settings ............................................................................................................ 105
14.2.2 MX Receiver Settings.................................................................................................................. 106
14.3 ADVANCED ............................................................................................................................................. 106
14.3.1 Audio Input................................................................................................................................. 106
14.3.2 Audio Output .............................................................................................................................. 106
14.3.3 Audio Encoder ............................................................................................................................ 107
14.3.4 Audio Decoder ............................................................................................................................ 107
14.3.5 Transmitter # ............................................................................................................................. 108
14.3.6 Receiver 1 ................................................................................................................................... 109
14.3.7 RTSP Transmitter ....................................................................................................................... 110
14.3.8 SAP Settings ............................................................................................................................... 111
15 DATA RS-422/485 ................................................................................................................................ 113
15.1 GENERAL SETTINGS .................................................................................................................................. 113
15.2 UART SETTINGS ..................................................................................................................................... 114
15.3 MAKE DATA CONNECTIONS ........................................................................................................................ 114
15.4 TCP SERVER SETTINGS ............................................................................................................................. 115
15.5 ADVANCED ............................................................................................................................................. 116
15.5.1 RS-4xx Settings ........................................................................................................................... 116
Contents
Page 6
15.5.2 Transmitter # ............................................................................................................................. 117
15.5.3 Receiver 1 ................................................................................................................................... 118
16 DATA RS-232 ........................................................................................................................................ 119
16.1 CONFIGURE RS-232 SETTINGS ................................................................................................................... 119
17 CC STREAMS ........................................................................................................................................ 121
17.1 CC CHANNELS, CC STATUS, AND ALARMS ..................................................................................................... 121
17.2 INPUT # SETTINGS ................................................................................................................................... 122
17.3 MAKE CONTACT CLOSURE CONNECTIONS ...................................................................................................... 122
17.4 ADVANCED ............................................................................................................................................. 123
17.4.1 Transmitter # ............................................................................................................................. 123
17.4.2 Receiver 1 ................................................................................................................................... 123
18 PTZ ....................................................................................................................................................... 125
18.1 ENABLE PTZ CONTROL .............................................................................................................................. 125
18.2 UPLOAD/REMOVE PTZ DRIVERS ................................................................................................................. 126
18.3 DATA SETTINGS ....................................................................................................................................... 126
19 SECURITY ............................................................................................................................................. 127
19.1 HTTPS .................................................................................................................................................. 127
19.2 CERTIFICATE/REQUEST INFORMATION ......................................................................................................... 128
19.3 CA-ISSUED CERTIFICATE ............................................................................................................................ 128
19.4 SELF-SIGNED CERTIFICATE .......................................................................................................................... 129
19.5 OPEN A SECURE CONNECTION .................................................................................................................... 129
20 EVENT MANAGEMENT ......................................................................................................................... 131
20.1 ASSOCIATE EVENTS WITH OUTPUT FACILITIES ................................................................................................. 131
20.1.1 CC Output # ................................................................................................................................ 132
20.1.2 CC Stream # ................................................................................................................................ 132
20.1.3 FTP Push ..................................................................................................................................... 133
21 DEVICE MANAGEMENT ........................................................................................................................ 135
21.1 GENERAL ............................................................................................................................................... 135
21.1.1 Identification .............................................................................................................................. 135
21.1.2 Device Name .............................................................................................................................. 136
21.1.3 Advanced ................................................................................................................................... 136
21.1.3.1 Alarm Settings ....................................................................................................................................... 136
21.1.3.2 LED control ............................................................................................................................................ 136
21.2 LOGGING ............................................................................................................................................... 137
21.2.1 Log file ........................................................................................................................................ 137
21.2.2 Syslog settings ............................................................................................................................ 137
21.3 SNMP .................................................................................................................................................. 138
21.3.1 SNMP System Information ......................................................................................................... 138
21.3.2 SNMP Communities ................................................................................................................... 138
21.3.3 SNMP Agent ............................................................................................................................... 138
21.3.4 SNMP Traps ................................................................................................................................ 139
21.3.5 Polling ........................................................................................................................................ 139
21.4 MX ...................................................................................................................................................... 140
21.4.1 MX/IP ......................................................................................................................................... 140
21.4.2 MX Notifications ........................................................................................................................ 140
21.5 AUTO DISCOVERY .................................................................................................................................... 141
21.5.1 Advertise the C-60 E-MC ............................................................................................................ 141
21.5.1.1 Note ....................................................................................................................................................... 141
21.6 ONVIF .................................................................................................................................................. 142
Contents
Page 7
21.6.1 Note ........................................................................................................................................... 142
21.7 FIRMWARE ............................................................................................................................................. 143
21.7.1 Firmware images ....................................................................................................................... 143
21.7.2 Current Version .......................................................................................................................... 143
21.7.3 Upgrade ..................................................................................................................................... 143
21.7.4 Troubleshoot upgrade issues ..................................................................................................... 144
21.7.5 Advanced ................................................................................................................................... 145
21.8 BACKUP/RESTORE ................................................................................................................................... 146
21.8.1 Backup ....................................................................................................................................... 146
21.8.2 Restore ....................................................................................................................................... 146
21.9 REBOOT ................................................................................................................................................. 147
22 USER MANAGEMENT ........................................................................................................................... 149
22.1 WEB ACCESS .......................................................................................................................................... 149
22.1.1 Access control ............................................................................................................................ 149
22.1.2 Manage user accounts ............................................................................................................... 150
22.2 LINUX .................................................................................................................................................... 151
23 DATE AND TIME ................................................................................................................................... 153
23.1 DATE AND TIME ....................................................................................................................................... 153
23.2 SNTP SETTINGS ...................................................................................................................................... 154
23.3 ADVANCED ............................................................................................................................................. 155
24 MULTICASTING .................................................................................................................................... 157
24.1 MULTICAST ............................................................................................................................................ 157
24.2 MULTI-UNICASTING ................................................................................................................................. 158
APPENDIX: ENABLE JAVASCRIPT ................................................................................................................... 159
APPENDIX: ENABLE UPNP IN WINDOWS 7 ................................................................................................... 161
APPENDIX: INSTALL A VIDEO PLAYER ........................................................................................................... 163
DOWNLOAD VIDEO PLAYER SOFTWARE ...................................................................................................................... 163
INSTALL QUICKTIME .............................................................................................................................................. 163
INSTALL VLC ........................................................................................................................................................ 164
APPENDIX: NTCIP CONFIGURATION ............................................................................................................. 165
SUPPORTED CONFORMANCE GROUPS ........................................................................................................................ 165
Configuration ............................................................................................................................................... 165
CCTV configuration ...................................................................................................................................... 166
Motion control ............................................................................................................................................. 166
SNMP MIB ........................................................................................................................................................ 166
APPENDIX: TECHNICAL SPECIFICATIONS ....................................................................................................... 167
Page 9
C h a p t e r 1
1 About this manual
What this manual covers
This manual applies to the C-60 E-MC v4.14, Siqura's H.264 multicodec video server.
It explains:
How to install the unit How to establish connections How to communicate with the unit How to configure the device settings How to operate the unit
Who should read this manual
This manual is intended for installers and users of the C-60 E-MC.
What you should already know
To be able to install and use the C-60 E-MC properly, you should have adequate knowledge and skills in the following fields.
Installing electronic devices Ethernet network technologies and Internet Protocol (IP) Windows environments Web browsers Video, audio, data, and contact closure transmissions Video compressions methods
Before you start the installation
We advise you to read and observe all instructions and warnings in this manual before you proceed. Retain this manual with the original bill of sale for future reference and warranty service. When you unpack your product, check for missing or damaged items. If any item is missing, or if damage is evident, do not install or operate this product. Contact your supplier for assistance.
Why specifications may change
At Siqura, we are committed to delivering high-quality products and services. The information given in this manual was current when published. As we are relentlessly working to improve our products and user experience, all specifications are subject to change without notice.
We like to hear from you!
Customer satisfaction is our first priority. We welcome and value your opinion about our products and services. Should you detect errors or inaccuracies in this manual, we would be grateful if you would inform us. We invite you to offer your suggestions and comments via t.writing@tkhsecurity.com. Your feedback helps us to further improve our documentation.
Acknowledgement
Siqura units use the open-source Free Type font-rendering library.
Page 11
C h a p t e r 2
2 Safety and compliance
This chapter presents the C-60 E-MC safety instructions and compliance information.
In This Chapter
Safety .............................................................................. 11
Declaration of Conformity ................................................... 14
2.1 Safety
The safety information contained in this section, and on other pages of this manual, must be observed whenever this unit is operated, serviced, or repaired. Failure to comply with any precaution, warning, or instruction noted in the manual is in violation of the standards of design, manufacture, and intended use of the module. Siqura assumes no liability for the customer's failure to comply with any of these safety requirements.
Trained personnel
Installation, adjustment, maintenance, and repair of this equipment are to be performed by trained personnel aware of the hazards involved. For correct and safe use of the equipment and in order to keep the equipment in a safe condition, it is essential that both operating and servicing personnel follow standard safety procedures in addition to the safety precautions and warnings specified in this manual, and that this unit be installed in locations accessible to trained service personnel only.
Safety requirements
The equipment described in this manual has been designed and tested according to the
UL/IEC/EN 60950-1 safety requirements. See the CE Declaration of Conformity for compliance
information.
Warning: If there is any doubt regarding the safety of the equipment, do not put it into
operation.
This might be the case when the equipment shows physical damage or is stressed beyond tolerable limits (for example, during storage and transportation).
Important: Before opening the equipment, disconnect it from all power sources.
The equipment must be powered by a SELV* power supply. This is equivalent to a Limited Power source (LPS, see UL/IEC/EN 60950-1 clause 2.5) or a "NEC Class 2" power supply. When this module is operated in extremely elevated temperature conditions, it is possible for internal and external metal surfaces to become extremely hot.
*
SELV: conforming to IEC 60950-1, <60 Vdc output, output voltage galvanically isolated from mains. All
power supplies or power supply cabinets available from Siqura comply with these SELV requirements.
C-60 E-MC
Page 12
Power source and temperature ratings
Verify that the power source is appropriate before you plug in and operate the unit. Use the unit under conditions where the temperature remains within the range given in the Technical Specifications of this product.
Optical safety
The following optical safety information applies to C-60 E-MC models with SFP interface only.
This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. This optical equipment contains Class 1M lasers or LEDs and has been designed and tested to meet IEC 60825-1:1993+A1+A2 and IEC 60825-2:2004 safety
class 1M requirements. Warning: Optical equipment presents potential hazards to testing and servicing personnel, owing
to high levels of optical radiation.
When using magnifying optical instruments, avoid looking directly into the output of an operating transmitter or into the end of a fiber connected to an operating transmitter, or there will be a risk of permanent eye damage. Precautions should be taken to prevent exposure to optical radiation when the unit is removed from its enclosure or when the fiber is disconnected from the unit. The optical radiation is invisible to the eye.
Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure.
The installer is responsible for ensuring that the label depicted below (background: yellow; border and text: black) is present in the restricted locations where this equipment is installed.
EMC
This device has been tested and found to meet the CE regulations relating to EMC and complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against interference to radio communications in any installation. The equipment generates, uses, and can radiate radio frequency energy; improper use or special circumstances may cause interference to other equipment or a performance decrease due to interference radiated by other equipment. In such cases, the user will have to take appropriate measures to reduce such interactions between this and other equipment.
Any interruption of the shielding inside or outside the equipment could make the equipment more prone to fail EMC requirements.
Non-video signal lines must use appropriate shielded Cat 5 cabling (S-FTP), or at least an equivalent. Ensure that all electrically connected components are carefully earthed and protected against surges (high voltage transients caused by switching or lightning).
ESD
Electrostatic discharge (ESD) can damage or destroy electronic components. Proper precautions should be taken against ESD when opening the equipment.
Safety and compliance
Page 13
Care and maintenance
The unit will normally need no maintenance. To keep it operating reliably:
Prevent dust from collecting on the unit. Do not expose the equipment to moisture.
RoHS statement
Global concerns over the health and environmental risks associated with the use of certain environmentally-sensitive materials in electronic products have led the European Union (EU) to enact the Directive on the Restriction of the use of certain Hazardous Substances (RoHS) (2002/95/EC). Siqura offers products
that comply with the EU’s RoHS Directive. The full version of the Siqura RoHS
statement can be viewed at www.siqura.com.
Product disposal
The unit contains valuable materials which qualify for recycling. In the interest of protecting the natural environment, properly recycling the unit at the end of its service life is imperative.
When processing the printed circuit board, dismantling the lithium battery calls for special attention. This kind of battery, a button cell type, contains so little lithium, that it will never be classified as reactive hazardous waste. It is safe for normal disposal, as required for batteries by your local authority.
C-60 E-MC
Page 14
2.2 Declaration of Conformity
Page 15
C h a p t e r 3
3 Product overview
This chapter introduces the C-60 E-MC and its features.
In This Chapter
Features ........................................................................... 15
Models .............................................................................. 15
Description ........................................................................ 16
Front Panel ....................................................................... 17
3.1 Features
C-60 E-MC
1x H.264 and 2x MPEG-2/4/MJPEG encoding Field-hardened Image quality monitor Tamper detection ONVIF Profile S Open Streaming Architecture Fiber and Ethernet over Coax (EoC) option Motion Adaptive Deinterlacing (M.A.D.™) Video motion detection Stereo audio Duplex serial data
3.2 Models
The Siqura C-60 E-MC series includes the following models.
C-60 E-MC
H.264/MPEG-2/-4/MJPEG video encoder with audio, data, and CC
C-60 E-MC -SFP
Model with empty SFP slot
C-60 E-MC /SA
Stand-alone version of rack-mount models
Rack-mount C-60 E-MC units are designed to be slotted into MC 10 or MC 11 power supply cabinets. Front panel LEDs indicate network status, stream status (sync), and DC power. All models have backup battery power for their clocks.
C-60 E-MC
Page 16
3.3 Description
General
The C-60 E-MC combines H.264 video encoding with MPEG-2, MPEG-4 or MJPEG. It offers an open solution for IP video CCTV applications. The video server features H.264 streaming with dual-streaming MPEG-2, MPEG-4 or MJPEG, low bandwidth, low latency, and interoperability with most other systems.
Multicodec and multistreaming
The C-60 E-MC is capable of streaming H.264, and 2x MPEG-2, MPEG-4, or MJPEG simultaneously. Each stream is optimised for its purpose: high-quality H.264 or MPEG-2 for live viewing, low-bandwidth MPEG-4 for storage, or easy-to-decode MJPEG for web applications and remote devices.
Picture enhancement
Almost every analogue camera offers an interlaced signal (PAL or NTSC). On digital computer monitors, this causes severe artefacts, such as comb edges on moving objects. To remove these artefacts the video signal has to be deinterlaced. This can be done in the monitor, but also at the beginning – at the encoder side. The C-60 E-MC is fitted with a motion adaptive deinterlacer (M.A.D.). Siqura’s M.A.D removes the interlacing artefacts on the moving objects only to preserve the vertical resolution of the image. In addition, the deinterlaced image is much easier to encode, saving bits for streaming and storage.
ONVIF and Open Streaming Architecture (OSA)
The Siqura C-60 E-MC supports both the international ONVIF standard and Siqura OSA for remote control, configuration, video switching, and streaming. The C-60 E-MC has been approved for ONVIF Profile S for streaming, PTZ, and I/O. Siqura’s OSA is a comprehensive HTTP RTSP based API, which gives access (next to ONVIF) to all controls and makes full integration easy.
Image quality monitor and tampering alarm
When the image from the camera becomes too poor, an image quality alert is raised. The built-in Image Quality Monitor continuously monitors the camera image on contrast, exposure, sharpness, and noise. In addition, the built-in Tamper Detector monitors changes in the
camera’s position or field of view. The instant a camera’s position is changed a tamper detect
alert is raised.
Audio, data, and I/O contacts
By combining audio, programmable I/O contacts, and data with streaming video, the C-60 E-MC provides all the interfaces necessary for any IP CCTV application. On the encoder module, you will find two bidirectional audio channels (lip-synchronised), two digital inputs and outputs, and two serial data ports (RS-232 and RS-422/482). The RS-422/485 data port is combined with a built-in PTZ controller supporting a number of PTZ protocols.
Fiber and EoC options
The C-60 E-MC is available with an optional, pluggable SFP slot. This offers unparalleled flexibility in connectivity. With fiber SFPs you can connect over multimode or single-mode optical fiber cable and cover distances from 100 m to 120 km or more. To connect over (existing) coax, you can use the Siqura® ECO-plug for Ethernet over Coax.
Product overview
Page 17
FTP push
Upon an event, the C-60 E-MC can push a JPG image to one or two FTP servers. The event can be triggered externally by VMD, the Image Monitor, or Tamper Detect. The C-60 E-MC can also periodically upload images to the remote server(s).
Web interface
Configuration, management, and live viewing are simplified by the access-controlled web interface. Full in-band control is available through Siqura Device Manager, Siqura’s MX™ Configuration Tool Kit, and the HTTP API. The C-60 E-MC is field-upgradeable.
3.4 Front Panel
Features and indications
The front panel of the C-60 E-MC has the following features.
C-60 E-MC
VIDEO
BNC connector
video input
RJ-45 socket or SFP
Ethernet I/O, electrical or fiber A1, CC1
RJ-45 socket
audio 1, contact closure 1
A2, CC2
RJ-45 socket
audio 2, contact closure 2
D1, D2
RJ-45 socket
RS-485/422, RS-232 Status indicator LEDs
*DC
green
DC power OK; blinks on identification and errors
*NV
red
no video on input
*SYNC
off
all streams disabled
green
all enabled streams OK
red
a transmitted stream fails
yellow
a received stream fails
red/yellow blink
at least one transmitted and at least one received stream fail
*D1
green/red
RS-4xx 0/1 data input
*D2
green/off
RS-232 0/1 data input
Ethernet socket LEDs
green/yellow
Green on/off: 100/10 Mbit Yellow on/blink: link OK, active Yellow off/flash: link down, TX
attempt
C-60 E-MC front panel features and indications
Pin assignments are given in section Connector Pin Assignments.
Page 19
C h a p t e r 4
4 Install the unit
This chapter describes how to install your C-60 E-MC unit and connect power, network, and signal cables.
In This Chapter
Power the unit ................................................................... 19
Connect cables .................................................................. 19
Startup ............................................................................. 20
Connector pin assignments ................................................. 20
Update device definitions .................................................... 21
4.1 Power the unit
To power a rack-mount unit
1. Insert the C-60 E-MC into a Siqura MC 10 or MC 11 power supply cabinet.
2. Plug the cabinet power cord into a grounded mains socket.
To power a stand-alone unit
A stand-alone (/SA) C-60 E-MC requires an external power supply adapter (12 Vdc).
1. Connect the power adapter to the power connector on the metal SA housing.
2. Plug the power adapter into a grounded mains socket.
4.2 Connect cables
Use the appropriate connectors on the C-60 E-MC front panel to connect the network and signal cables.
To connect the C-60 E-MC to your 100/10Mbit IP/Ethernet network
Plug the network cable into the RJ-45 Ethernet socket on the front panel.
Important: Use appropriate cabling (Cat 5 or Cat 6) for network links.
To connect a video source
Connect the coaxial cable from your video source (a camera, for example) to the video input
BNC connector on the front panel.
To connect audio, data, and/or contact closure sources/destinations
Plug the cables carrying audio, data, and/or contact closure signals into the corresponding
RJ-45 sockets on the C-60 E-MC front panel.
Important: Through-connecting the signal ground lines of RS-data interfaces is mandatory, as is
proper grounding. See also the section on pin assignments later in this chapter.
C-60 E-MC
Page 20
4.3 Startup
After startup, the DC LED will light and the network indicator lights go through an on/off sequence.
The power DC LED should always be lit. The link and No Video lights eventually glow upon establishing of a good network link and the absence of an input video signal, respectively.
The sync LED displays as described in the Front Panel section.
Important: Before you can make any signal connection, you must assign at least a valid IP
address (the unit's identity for the network) and a subnet mask to the unit. The Connect the unit chapter explains how to do this.
4.4 Connector pin assignments
Modular socket pin assignments
The modular socket pin assignments are such that similar sockets of different modules may be connected back to back with reversed cable (RS-232 interfaces excepted). See the figure below for the socket pin numbering convention used. For 2-wire RS-485 links, I/O is through pins 1 and 2 of socket 3.
Pin assignments of the three modular sockets. For 2-wire RS-485 use pins 1 and 2 of socket 3.
Note: Polarity indications for RS-422/485 are based on a convention used by BT, which may
conflict with other implementations. Pelco systems, for example, use an implementation for which you have to connect Siqura (+) to Pelco (-) and vice versa.
Install the unit
Page 21
Ethernet connector pin assignment
Ethernet connector socket pinning
4.5 Update device definitions
If the C-60 E-MC is not supported by the Siqura application software on your host PC you can download EMX updates and MX Plug-in updates at www.siqura.com. Install the EMX update first if you are performing both update types.
Note: There is no need to install these updates if you do not use MX applications.
EMX updates
Install the EMX update using the Showroom menu. The Embedded MX network driver will be updated with the latest changes.
MX Plug-in updates
The updater will update the shared copy of device definitions used by Ethernet-based Siqura MX applications, such as Operator Storage, Operator Office, MX Viewer, MX Configuration Tool, and the MX SDK. An existing installation of the SNM Configuration and Service Tool will also be updated.
Page 23
C h a p t e r 5
5 Connect the unit
With your C-60 E-MC installed, the next step is to establish an IP connection and set up video and (if applicable) other signal links. This chapter describes how you can change the factory-set IP address and subnet mask of the C-60 E-MC to make them compatible with the network segment in which the unit will be used. It also discusses how to configure signal streaming.
In This Chapter
Establish a network connection ............................................ 23
Establish video and other signal connections ......................... 25
5.1 Establish a network connection
The webpages of the C-60 E-MC provide a convenient way of accessing its settings. You can log on to the internal web server of the C-60 E-MC from a PC which is on the same subnet as the unit. Follow the steps below to open communication with the C-60 E-MC and configure its network settings.
Step 1:
Set the network adapter of the PC to the factory-set subnet of the C-60 E-MC and then connect the two devices to the network.
Step 2:
Access the unit from a web browser or other tool installed on the PC.
Step 3:
Set the IP address and subnet mask of the C-60 E-MC to the subnet that it is going to be used in and reboot the unit.
To address the unit from the same PC again, configure the network adapter of the PC once more to assign the PC to the same subnet as the unit.
The factory-set IP address of the C-60 E-MC is in the 10.x.x.x range. You will find it printed on a sticker on the unit.
C-60 E-MC product sticker
Note: This is the address the unit reverts to if you issue a "Reset to factory settings; incl. network
settings" command and reboot the unit (see chapter Device Management).
C-60 E-MC
Page 24
Step 1: Set the PC to the factory-set subnet of the unit
To configure the network adapter on the PC
1. In Control Panel, open Network and Sharing Center.
2. Select the connection to be configured, and then click Properties.
3. On the items list, select Internet Protocol Version 4 (TCP/IPv4).
4. Click Properties.
5. In the Internet Protocol Version 4 (TCP/IPv4) Properties dialog box, click Use the following
IP address.
6. Enter an IP address which assigns your PC to the same subnet as the C-60 E-MC - that is, within the 10.x.x.x range. Use 255.0.0.0 as a subnet mask.
Important: To prevent conflicts, be sure to choose a unique IP address. No two devices on a
network can have the same IP address.
7. To apply the new settings, click OK.
Setting the IP settings of the PC to the factory-set IP settings of the unit
At this point, connect your PC to the C-60 E-MC. You can connect them directly using a crossover cable, or connect both to a switch.
Step 2: Access the unit
Using a standard web browser you can now log on to the web server of the C-60 E-MC.
Step 3: Change the network settings of the unit
The Network page enables you to make the network addressing of the unit compatible with the network it will be added to. You can set a fixed IP address or have the IP address assigned by a DHCP server. In the latter case, open the Advanced Settings and enable DHCP. Do not forget to save and reboot the unit after changing the settings.
Connect the unit
Page 25
5.2 Establish video and other signal connections
Connection methods
With the IP connection established, video and other signal connections can be made. The easiest way to connect with video and audio is by using RTSP or SAP. For more information, see the Interfaces chapter.
An alternative, convenient method to establish video, audio, data, and contact closure (I/O contacts) connections is to use the webpages of the C-60 E-MC. For detailed information, see the chapters which describe these pages.
Separate application software, such as Siqura’s MX Configuration Tool, can be used as well.
Streams and connectors
Each signal stream transmitted and received by the C-60 E-MC (see the figure below) can be conceived of as using virtual connectors (transmitters and receivers) on the network side. Each of the virtual connectors has a name. Through the internal webpages, the receivers can be assigned a port number which must be used only once for that particular device. Depending on context, the assignment is automatic or manual. Note that port numbers must be even.
Link facilities of the C-60 E-MC.
All arrows represent separate and independent connections over Ethernet.
The abbreviations ‘tx’ and rx’ refer to the network side of the module.
- tx: the stream is transmitted to the network
- rx: the stream is received from the network
C-60 E-MC
Page 26
General procedure for making links
In both connection methods mentioned above, perform the following steps to make a unicast one-way link (video, audio, data, contact closure) from source to destination.
In the transmitter, specify a destination IP address and a destination port number. In a compatible receiver, specify the transmitter IP address (source) and the local input port
number (= the destination port number mentioned above).
Do not forget to enable both the transmitter and the receiver.
It is possible for external software to configure a stream, for instance a video stream or a contact closure stream to transmit a contact closure alarm. In such cases, port numbers are assigned automatically from a range of unused values.
For more information on port number assignment, see Port Numbers.
5.2.1 Port numbers
A valid UDP port number in a Siqura A-, C-, and S-series system is an unsigned 16-bit integer between 1024 and 65536. Generally, you do not need to select other than the default receiver port numbers as given in the MIB (Management Information Base). If you want to change these receiver port numbers for some reason, use even numbers. A given receiver port number N is associated with the port number N+1, through which control information is returned to the source.
Eligible port numbers in general are within the range indicated above, with some exceptions. Those within the 3000-10000 range are reserved and/or hard-coded, or may become reserved, so only 10000-65535 are generally safe. Default port numbers (used by receivers) are shown in the following table.
General
Example
Video
50xxx
Video
50010
Audio
51xxx
Audio
51010
Data
52xxx
Data 1
52010 (RS-4xx)
Data 2
52020 (RS-232)
CC
53xxx
CC 1
53010
CC 2
53020
Default port numbers
Siqura MX applications using automatic port number allocation may use 55000 and up.
Page 27
C h a p t e r 6
6 Interfaces
A variety of methods can be employed to communicate with the C-60 E-MC. This chapter outlines the interfaces you can use to control the unit and manage the media streams it is handling.
In This Chapter
ONVIF .............................................................................. 27
OSA ................................................................................. 27
Web UI ............................................................................. 27
MX/IP ............................................................................... 28
SNMP ............................................................................... 28
SAP .................................................................................. 28
NTCIP ............................................................................... 28
6.1 ONVIF
The Open Network Video Interface Forum (ONVIF) is an open industry forum for the development of a global standard for the interface of IP-based physical security products. ONVIF is committed to the adoption of IP in the security market. The ONVIF specification ensures interoperability between products regardless of manufacturer. It defines a common protocol for the exchange of information between network video devices including automatic device discovery, video streaming and intelligence metadata. The C-60 E-MC fully supports ONVIF. It has been tested to support ONVIF Profile S.
6.2 OSA
Siqura's Open Streaming Architecture (OSA) consists of a standard set of open communication protocols to govern media streaming via RTSP and equipment management via HTTP. The Siqura Programming Interface enables easy integration of the C-60 E-MC with third-party products. The protocol consists mainly of different CGI (Common Gateway Interface) program calls for listing and configuring parameters. For detailed information, refer to the Siqura Programming Interface specification. You can download this HTTP API specification at www.siqura.com.
6.3 Web UI
Using the C-60 E-MC's web server is the most straightforward way to access the unit. The webpages enable you to configure the settings of the C-60 E-MC and view live video images from a standard web browser.
C-60 E-MC
Page 28
6.4 MX/IP
MX/IP is a proprietary Siqura protocol which gives direct access to the settings of the C-60 E-MC. Using special MX software, such as MX Configuration Tool, C-60 E-MC settings can be read from and written to the Management Information Base (MIB), a list of variables stored inside the unit. Offering full control of the C-60 E-MC, the MIB enables you to remotely configure device settings and manage media streams. Additional MX viewing and control software offers real-time monitoring of video streams and playback of recorded images. For more information about MX/IP, the MIB, and Siqura's EMX network service, refer to the manuals which document the MX SDK and the MX applications.
Note: If you prefer using open standards, you can disable the MX/IP protocol. This is done on the
MX tab of the Device Management page. Be aware that doing so prevents you from upgrading the C-60 E-MC firmware through MX Firmware Upgrade Tool.
6.5 SNMP
The Simple Network Management Protocol (SNMP), part of the internet protocol suite, can be used to monitor network devices such as the C-60 E-MC for conditions or events that require administrative attention. For more information, refer to appropriate literature on SNMP.
The C-60 E-MC supports in-band SNMP. Via SNMP, several status variables can be read and traps can be generated on events. You can configure C-60 E-MC SNMP settings on the SNMP tab of the Device Management page.
The SNMP Agent is MIB-2 compliant and supports versions 1 and 2c of the SNMP protocol.
Note: The C-60 E-MC includes SNMP support for its image quality monitor and tamper detect
functions. A trap is sent when bad image quality or camera tampering is detected and another one when the situation returns to normal.
Required MIB files can be downloaded at www.siqura.com.
6.6 SAP
The C-60 E-MC supports the Session Announcement Protocol (SAP), a protocol used for broadcasting multicast session information. A SAP listening application can listen to the announcements advertised by the C-60 E-MC SAP announcer. The application can use this information to receive a video or audio stream that the C-60 E-MC is transmitting to the advertised multicast address. For more information, see the description of the Video and Audio pages.
6.7 NTCIP
The National Transportation Communications for ITS Protocol (NTCIP) is a communication protocol deployed in Intelligent Transportation Systems (ITS) in the USA. It is a family of standards designed to provide definitions of common data elements and communication protocols for the interaction between traffic management centre(s) and road-side devices such as cameras, traffic signals, and highway lighting. The goal of the standards is to achieve interoperability and interchangeability between systems manufactured by different vendors in order to reduce the total cost of traffic systems, including maintenance.
The C-60 E-MC supports all the mandatory parts and some of the optional parts of the NTCIP CCTV specification as laid down in the NTCIP 1205:2001 v01.08 document. For details about the NTCIP configuration of the C-60 E-MC, see Appendix: NTCIP Configuration.
Interfaces
Page 29
The C-60 E-MC supports the standard NTCIP SNMP MIB. This MIB database is used to store information, which in turn will be used to control cameras and other devices in the transportation management system. An electronic version of the MIB is available from a NEMA FTP site. To get access to the FTP site, send your name, organisation name, and email address to ntcip@nema.org, and request access.
Loading...
+ 139 hidden pages