P-07
Technical Features
Output Power: 3550W +/- 5% variation across the band
RF Output Impedance: 50 Ohms
RF Output Connector: DIN 7/16 (or EIA 1 5/8)
Frequency Range: 80 to 110MHz
Harmonic and Spurious Attenuation: >75dBc or better
RF Features:
Power Supply:
AC Input:
Not available in this version
DC Input:
Bank or Varistors (285V), gas dischargers and fuses
AC Surge Protection:
93% or better in 220V AC
Power Supply Efficiency:
200kHz
Switching Frequency:
Approximately 4300W from AC (for 3500W RF output set)
Power Consumption:
Power Bridge
AC Input Connector:
General Features:
38,8kgs net weight
Weight:
483mm (6”) wide, 133,35mm (3 RU) high, 700mm (27.5”) deep
Dimensions:
0 to +45 Degrees Celsius
Ambient Temperature Range:
95% at +45ºC without condensation
Maximum Humidity:
CPU and Display Features:
PIC Processor, microcontrolled with Sinteck PWC3.5K1 Software V.1.0
CPU:
Non-volatile, retention >40 years
Memory:
VDC protection, ADC protection, TEMP excedeed, VSWR excedeed
Full Micro-controlled protections:
Selection of measured patterns, RF power Adjust
Panel Keys Control:
16 colums, 2 lines, green back light
LCD Display:
RF Input:
50 Ohms
Input Impedance:
N Female (UHF under request)
Input Connector:
*Specification subject to change without notice
5 to 10W (Standard version)
Input RF power (normal operating):
20W
Input RF power (maximum):
220V 47-63Hz +/- 25% Variation
PowerCell Series
SRFPWC-090909 REV.A
SERIES