Press this button to turn on/off the unit. After that, the sleep function will be canceled but the preset time
is still remained.
2) MODE
Auto, Cool, Dry Fan, Heat modes can be selected circularly by pressing this button. Auto mode is the
default after power on. Under Auto mode, the temperature will not be displayed. Under Heat mode, the initial
value is 28℃(82℉); Under other modes, the initial value is 25℃(77℉).
3) SLEEP
Sleep On and Sleep Off can be selected by pressing this button. After powered on, the default is Sleep Off.
After the unit is turned off, the Sleep function is canceled. When the sleep function is set already, the symbol
will be displayed. And at this time, the time of timer can be adjusted. Under Fan and Auto modes, this
unction is not available.
)
18
Wireless Remote Controller YT1F
4) FAN
Auto, Low, Middle, or High fan speed can circularly selected by pressing this button. After powered on,
the default is Auto speed. Under Dehumidifying mode, only Low fan speed is available.
5) CLOCK
The clock can be set up by pressing this button, with the symbol displayed and blinking. In such a
case, pressing+ or - within 5 seconds can adjust the value. If the button is pressed down for more than 2
seconds, the value on ten’s place will increase by 1 in every 0.5 seconds. After that, repressing this button
and then symbol stops blinking, which indicates the setting is made successfully. After powered on, the
default value is 12:00 with
otherwise it is the Timer value.
6) LIGHT
Light On and Light Off can be set by pressing this button when the unit is at On or Off status. After
powered on, the default is Light On.
7) TURBO
In Cool or Heat mode, pressing this button can activate or deactivate this function. When this function
is on, its symbol will be displayed. Any change of either mode or fan speed will make this function canceled
automatically.
8) BLOW
BlOW On and BLOW Off can be set by pressing this button. In Cool and Dehumidifying modes, press
this button to activate this function and then “BLOW” will be displayed. After that, it can be canceled by
repressing this button. After powered on, the default is Blow Off. If the ON/OFF button is operated or the unit
is switched to the Cool or Dehumidifying mode, it will keep its original status. When the unit is turned off,
Only Blow Off is available. Under Auto, Fan or Heat mode, this function is unavailable.
9)
-
The preset temperature can be decreased by pressing this button. If the button is pressed down for more
than 2 seconds, the temperature will be decreased quickly until it is released, with ℃ (℉) displayed al the
time. Under Auto mode, the temperature adjustment is unavailable.
10)
+
The preset temperature can be increased by pressing this button. If the button is pressed down for more
than 2 seconds, the temperature will be increased quickly until it is released, with ℃(℉) displayed all the
time. Under Auto mode, the temperature adjustment is unavailable. The setting range is 16-30 ℃ or 61-86
11) TEMP
It can be decided by pressing this button which temperature will be displayed, indoor set temperature, or
indoor ambient temperature. When the indoor unit is powered on, the indoor set temperature will be displayed,
while if the status is changed to
set temperature will be displayed again when the controller receives other remote controls signals. Without
setting this function, the default is the indoor set temperature.
12) SWING UP/DOWN ()
The swing angle which circularly changes as below can be selected by pressing this button:
displayed. Once the symbol is displayed, the current time is the Clock value;
℉
, the indoor ambient temperature will be displayed. However, the indoor
19
Wireless Remote Controller YT1F
This kind of remoter controller is universal. And the three swing statuses of are the same
as that of
current position.
pressing + or - within 5 seconds. Each press will make the time increased or decreased by 1 minute. If
the button is pressed down for more than 2 seconds, the time will be changed quickly in such a way: rstly
the value on the one’s place is changed and then is the value on the ten’s place. Once Timer ON has been set
already, it can be canceled by repressing it. Before the setting, please adjust the CLOCK to the current actual
time.
same as that for TIMER ON.
default is HEALTH ON.
is on, the I FEEL information will be sent out in 200ms after each operation on the controller and the remote
controller will send the temperature information to the main controller every 10 minutes.
.
If the swing function is deactivated when the air guide louver is swing up and down, it will stop at the
indicates that the air guide louver swings up and down among all ve positions.
13) AIR (
AIR ON or Air OFF can be selected by pressing this button.
14) TIMER ON
“ON” will be displayed and blink for 5 seconds by pressing this button, and soon adjust the time by
15) TIMER OFF
TIME OFF can be activated by pressing this button, with “OFF” blinking. The method of setting is the
16) HEALTH (
This function can be activated or deactivated by pressing this button. After the unit is turned on, the
17) I FEEL
This function can be activated by pressing this button and canceled by another press. When this function
)
)
2 Guide for General Operation
a. After powered on, press ON/OFF and then the unit will start to run. (Note: when powered off, the
guide louver of the main unit will close automatically).
b. Press MODE to select the desired running mode.
c. Press + or - to set the desired temperature (it is unnecessary to set the temperature under the AUTO
mode.)
d. Press FAN to set the fan speed, AUTO, LOW, MID, or HIGH.
e. Press
to select the swing angle.
3 Guide for Optional Operation
a. About BLOW
This function indicates that moisture in the evaporator of the indoor unit will be dried after the unit is
stopped to avoid mould.
BLOW ON: When press the ON/OFF button to turn off the unit, the indoor fan will continue running
① .
for about another 10 minutes at the low speed. In this case, the indoor fan can be stopped directly by pressing
the button BLOW.
20
Wireless Remote Controller YT1F
BLOW OFF: When press the ON/OFF button to turn off the unit, the whole unit will be stopped
② .
completely.
b. About AFTERHEAT BLOW
Under the Heat mode or Auto Heat mode, if the unit is turned off, the compressor and outdoor fan will
stop running immediately and the upper and lower guide board will rotate to the horizontal position, while the
indoor fan will still run at the low fan speed. Then, 10 seconds later, the unit will stop completely.
c. About AUTO RUN
When AUTO RUN is selected, the setting temperature will not be displayed on the LCD and the unit will
choose the suitable running mode automatically in accordance with the room temperature.
d. About TURBO
If this function is activated, the unit will run at super-high fan speed to cool or heat quickly so that the
ambient temperature will approaches the preset temperature as soon as possible.
21
Wired Controller XK19
Ⅰ
1 Wired Controller XK19
It is optional for the cassette type, wall-mounted, and oor ceiling indoor units.
1.1 Outside View of the Wired Controller
Wired Controller XK19
Fig.1 Outside View of the Wired Controller
1.2 LCD of the Wired Controller
Fig.2 LCD of the Wired Controller
1
Wired Controller XK19
1.3 Introduction to the Symbols on LCD
Table 1
No.SymbolsDescription
1
2
3
4
5
6
7
8SHIELD
9TURBOTurbo function.
10MEMORY
11MASTERMaster wired controller (this function is yet unavailable for this unit).
12
13SAVEEnergy-saving function.
14
15E-HEATERElectric auxiliary heating function.
16BLOWBlow function.
17
18QUITEQuiet function (two types: quiet and auto quiet).
19SETIt will be displayed under the debugging mode.
Swing function.
Sleep function (3 types: sleep 1,sleep2 and sleep 3).
Running modes of the indoor unit (Cooling, Dry, Fan and Heating).
Defrosting function for the outdoor unit.
Gate-control function (this function is yet unavailable for this unit).
Lock function.
High, middle, low or auto fan speed of the indoor unit.
Shield functions (buttons, temperature, On/Off, Mode or Save is shielded or
Save is shielded by the remote monitor.
Memory function (The indoor unit resumes the original setting state after
power failure and then power recovery).
It blinks under on state of the unit without operation of any button.
Ambient/preset temperature value.
Timing value.
2 Buttons
2.1 Buttons on the Wired Controller
Fig. 3 Buttons on the Wired Controller
2
Wired Controller XK19
2.2 Function of the Buttons
Table 2
No.NameFunction
Function selection and cancellation.
1Enter/cancel
2▲
6▼
3FanSetting of the high/middle/low/auto fan speed.
4ModeSetting of the Cooling/Heating/Fan/Dry mode of the indoor unit.
5Function
7TimerTimer setting.
8On/OffTurn on/off the indoor unit.
4+2 ▲+Mode
3 +6 Fan+▼
2 +6▲+▼
①
Press it for 5s to examine the outdoor ambient temperature.
②
Running temperature setting of the indoor unit, range:16~30
①
Timer setting, range:0.5-24 hr.
②
Switchover between quiet/auto quiet or among sleep1/sleep2/sleep 3.
③
Switchover among the functions of Swing/Sleep/Turbo/Save/E-heater/Blow /
Quiet etc.
Press them for 5s under off state of the unit to enter/cancel the Memory function
(If memory is set, indoor unit after power failure and then power recovery will
resume the original setting state. If not, the indoor unit is defaulted to be off after
power recovery. Memory off is default before delivery.).
By pressing them at the same time under off state of the unit,
on the wired controller for the cooling only unit, while
the wired controller for the cooling and heating unit.
Upon startup of the unit without malfunction or under off state of the unit,press
them at the same time for 5s to enter the lock state, in which case, any other
buttons won’t respond the press. Repress them for 5s to quit this state.
℃ .
will be displayed
will be displayed on
3 Operation Instructions
3.1 On/Off
Press On/Off to turn on the unit and turn it off by another press.
Note: The state shown in Fig.4 indicates the “Off” state of the unit after power on. The state shown in
Fig.5 indicates the “On” state of the unit after power on.
Fig. 4 “Off” State Fig. 5 “On” State
3.2 Mode Setting
Under the “On” state of the unit, press Mode to switch the operation modes as the following sequence:
Cooling-Dry-Fan-Heating.
3
Wired Controller XK19
3.3 Temperature Setting
Press ▲or ▼ to increase/decrease the preset temperature. If press either of them continuously, the
temperature will be increased or decreased by 1℃ every 0.5s,as shown in Fig.6.
In the Cooling, Dry or Heating mode, the temperature setting range is 16℃~30
In the Fan mode, the setting temperature is xed at 26℃.
In the Auto mode, the setting temperature is unadjustable.
Fig.6
3.4 Fan Setting
Under the “On”/”Off” state of the unit, press Fan and then fan speed of the indoor unit will change
circularly as shown in Fig.7.
℃ .
Auto
Low
Middle
High
Fig.7
3.5 Timer Setting
Under the “On”/”Off” state of the unit, press Timer to set timer off/on.
Timer on setting: press Timer, and then LCD will display “xx.x hour”, with “hour” blinking. In this case,
press ▲or ▼ to adjust the timing value. Then press Enter/cancel to conrm the setting.
Timer off setting: press Timer, if LCD won’t display xx.x hour, and then it means the timer setting is
canceled.
4
Wired Controller XK19
Timer off setting under the “On” state of the unit is shown as Fig.8.
Fig. 8 Timer off Setting under the “On” State of the Unit
Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by 0.5hr. If
either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every 0.5s.
3.6 Swing Setting
Swing On: Press Function under on state of the unit to activate the swing function. In this case, will
blink. After that, press Enter/cancel to make a conrmation.
Swing Off: When the Swing function is on, press Function to enter the Swing setting interface, with
blinking. After that, press Enter/cancel to cancel this function.
Swing setting is shown as Fig.9.
5
Wired Controller XK19
Fig. 9 Swing Setting
Note:
Sleep, Save, Turbo, Blow or Quiet setting is the same as the Swing setting.
① .
After the setting has been done, it has to press the key “Enter/cancel” to back to the setting status or
② .
quit automatically ve seconds later.
3.7 Sleep Setting
Sleep on: Press Function under on state of the unit till the unit enters the Sleep setting interface. Then
press ▲or ▼ to switch among Sleep 1, Sleep 2 and Sleep 3. After that, press Enter/cancel to conrm the
setting.
Sleep off: When the Sleep function is activated, press Function to enter the Sleep setting interface. After
that, press Enter/cancel to can this function.
Sleep setting is shown as Fig.10.
6
Wired Controller XK19
Fig. 10 Sleep Setting
Sleep off is default after power failure and then power recovery, and the sleep functions is unavailable
under the fan mode.
There are three Sleep modes: Sleep 1, Sleep 2 and Sleep 3.
a. Sleep 1
In the Cooling or Dry mode, the temperature will increase by 1℃ after the unit runs under Sleep 1 for 1hr
and 1℃ after another 1hr.After that, the unit will run at this temperature.
In the Heating mode, the temperature will decrease by 1℃ after the unit runs under Sleep 1 for 1hr and
1℃ after another 1hr. After that, the unit will run at this temperature.
b. Sleep 2
In the Cooling mode, the temperature may be set between 16℃-23℃, 24℃- 27℃ or 28℃- 29℃
or at 30℃, and their Sleep curves are shown in Fig.11 (Note: The curve is only for reference, the actual
temperature is subject to the time point.).
For example: The temperature in the Cooling mode is set at 25
temperature will increase by 1℃ every 1hr. After it increases by 2℃ in total, it will keep at 27℃. 7 hours
later, it will decrease by1℃, i.e. 26℃.After that, the unit will keep running at 26℃.
. Under the mode of Sleep 2, the
℃
7
Wired Controller XK19
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
0123456789101112
T i m e /( H r )
T
e
m
p
/
(
℃
)
31
T
e
30
m
29
p
/
28
(
27
℃
)
26
25
24
23
22
21
20
19
18
17
16
0123456789101112
Tim e /( Hr)
Fig.11 Sleep Curve of Sleep 2 in Cooling Mode
In the Heating mode, the temperature may be set at 16℃ or between 17℃- 20℃, 21℃-27℃ or 28℃-
30℃ and their Sleep curves are shown in Fig.12:
Fig.12 Sleep Curve of Sleep 2 in Heating Mode
8
Wired Controller XK19
For example, the temperature in the Heating mode is set at 22
temperature will decrease by 1℃ every 1hr. After it decreases by 2℃in total, i.e. 20℃,the unit will keep
running at 20
where the timing value once is displayed and the corresponding temperature with the last Sleep curve setting
is displayed where the ambient/preset temperature once in displayed.
Sleep curve setting is displayed where the ambient/preset temperature once is displayed.
℃ .
c. Sleep 3
Sleep curve setting under Sleep 3(DIY mode)
d. Under the mode of Sleep 3, press Timer to enter the Sleep setting. In this case, “1 HOUR” is displayed
e. Press ▲or ▼ to change the corresponding temperature setting.
f. Press Timer, time will automatically increase by 1hr, and the corresponding temperature with the last
g. Repeat step 2 and step 3 till 8 HOUR Sleep setting is nished.
h. Press Enter/cancel to conrm the setting.
Sleep curve setting under Sleep 3 is as shown in Fig.13.
.Under the mode of Sleep2, the
℃
Fig. 13 Sleep Curve Setting under Sleep 3
Notes:
During the above setting, if Function is pressed down or there is not any operation within 5s, sleep
① .
curve setting will be canceled.
26℃ is the default Sleep curve temperature before delivery. The wired controller will automatically
② .
memorize the Sleep curve after the setting.
3.8 Turbo Setting
Turbo function: The unit at the high fan speed can realize quick cooling or heating so that the room
temperature can quickly approach the setting value.
In the Cooling or Heating mode, press Function till the unit enters the Turbo setting interface and then
press Enter/Cancel to conrm the setting.
9
Wired Controller XK19
When the Turbo function is activated, press Function to enter the Turbo setting interface and then press
Enter/Cancel to cancel this function.
Turbo function setting is as shown in Fig.14.
Fig.14 Turbo Setting
Notes:
When the Turbo function is activated, if the difference between the room temperature and set
① .
temperature is at or below 2℃ (detected in successive 1 min.), the Turbo function will be automatically
deactivated.
Turbo function is unavailable in the Dry and Fan mode. And the Turbo function is off after power
② .
failure and then power recovery. If Quiet function is on, Turbo function will be canceled subsequently.
3.9 Save Setting
Save: Energy saving which will result the air conditioner runs in smaller temperature range is realized by
setting lower limited value in the Cooling or Dry mode and upper limited value in the Heating mode.
Save Setting for Cooling:
Under the “On” state and in the Cooling or Dry mode of the unit, press Function to enter the Save setting
interface and then press ▲or ▼ to adjust the lower limited value in the Cooling mode. After that, press Enter/
Cancel to activate the Save function. The initial lower limited value in the Cooling mode is 26℃.
When the Save function is activated, press Function to enter the Save setting interface and then press
Enter/cancel to cancel this function.
The Save setting for cooling is shown in the Fig.15
10
Wired Controller XK19
Fig. 15 Saving Setting for Cooling
Save Setting for Heating:
Under on state or in the Heating mode of the unit, press Function to enter the Save setting interface and
then press ▲or ▼ to adjust upper limited value in the Heating mode. After that, press Enter/Cancel to activate
the Save function for heating. The upper initial limited value in the Heating mode is 20℃.
After the Saving function is activated, press Function to enter the Save setting interface and then press
Enter/Cancel to cancel this function.
Save setting for heating is as shown in Fig. 16
11
Wired Controller XK19
Fig.16 Save Setting for Heating
Notes:
If press Function on the Save setting interface or if there is not any operation for 5s after last button
① .
press, the Save setting will be canceled automatically by the system, with memorizing the present setting data.
When power is on after the power failure, the Save function will be memorized.
② .
3.10 E-heater Setting
E-heater (auxiliary electric heating function): In the Heating mode, E-heater is allowed to be turned on for
improvement of efciency.
Once the wired controller or the remote controller enters the Heating mode, this function will be turned on
automatically.
Press Function in the Heating mode to enter the E-heater setting interface and then press Enter/cancel to
cancel this function.
Press Function to enter the E-heater setting interface, if the E-heater function is not activated, and then
press Enter/Cancel to turn it on.
The setting of this function is shown as Fig.17 below:
12
Wired Controller XK19
Fig.17 E-heater Setting
3.11 Blow Setting
Blow function: After the unit is turned off, the water in evaporator of indoor unit will be automatically
evaporated to avoid mildew.
In the Cooling or Dry mode, press Function till the unit enters the Blow setting interface and then press
Enter/Cancel to active this function.
When the Blow function is activated, press Function to the Blow setting interface and then press Enter/
Cancel to cancel this function.
Blow function setting is as shown in Fig.18
13
Wired Controller XK19
Fig.18 Blow Setting
Notes:
When the Blow function is activated, if turning off the unit by pressing On/Off or by the remote
① .
controller, the indoor fan will run at the low fan speed for 10 min, with “BLOW” displayed on the LCD.
While, if the Blow function is deactivated, the indoor fan will be turned off directly.
Blow function is unavailable in the Fan or Heating mode.
② .
3.12 Quiet Setting
Quiet function consists of two kinds: quiet and auto quiet.
Press Function till the unit enters the Quite setting interface, with “Quiet” or “Auto” blinking. In this case,
press ▲or ▼ to switch between Quiet and Auto and then press Enter/cancel to make a conrmation.
When the Quiet function is activated, press Function till the unit enters the Quite setting interface, with
“Quite” or “Auto” blinking. Then press Enter/cancel to cancel this function.
Quiet function setting is as shown in Fig.3.16:
14
Wired Controller XK19
Fig.19 Quiet Setting
Notes:
When the Quite function is activated, the fan speed is low and un-adjustable.
① .
When the Auto Quite function is activated, the unit will run according to the difference between the
② .
room temperature and the setting temperature. In this case, the fan speed is adjustable.
Difference between the room temperature and the setting temperature: the fan speed will keep its current
state if the temperature difference ≥ 4℃; the fan speed will reduce one grade if 2
difference ≤3℃; the fan speed will be at min. grade if the temperature difference ≤1℃.
When the Auto Quiet function is on, the fan speed can not be raised but reduced. If the high fan speed
③ .
is manually adjusted, the function will quit automatically.
There is not Auto Quiet function in the Fan or Dry mode. Quiet off is default after power failure and
④ .
then power recovery.
3.13 Other Functions
a. Lock
Upon startup of the unit without malfunction or under the “Off” state of the unit, press ▲ and ▼ at the
same time for 5s till the wired controller enters the Lock function. In this case, LCD displays
repress these two buttons at the same time for 5s to quit this function.
Under the Lock state, any other button press won’t get any response.
b. Memory
Memory switchover: Under the “Off” state of the unit, press Mode and ▲ at the same time for 5s to
switch memory states between memory on and memory off. When this function is activated, Memory will be
displayed. If this function is not set, the unit will be under the “Off” state after power failure and then power
recovery.
the temperature
℃ ≤
. After that,
15
Wired Controller XK19
Memory recovery: If this function has been set for the wired controller, the wired controller after power
failure will resume its original running state upon power recovery. Memory contents: On/Off, Mode, set
temperature, set fan speed, Save function and Lock function.
c. Enquiry of the Outdoor Ambient Temperature
Under the “On” or “Off” state of the unit, press Enter/Cancel for 5s, and the outdoor ambient temperature
will be displayed after a sound of click. This enquiry state will quit by pressing Function or On/Off or during
the temperature adjustment. If there is not any operation for 10s, it will also quit automatically.
4 Errors
If there is an error occurring during the operation of the system, the error code will be displayed on the
LCD, as show in Fig.20. If multi errors occur at the same time, their codes will be displayed circularly.
Note: In event of any error, please turn off the unit and contact the professionally skilled personnel.
Fig.20
16
Wired Controller XK19
Table 3 Meaning of Each Error
Error
High pressure protectionE1
Low pressure protectionE3
Discharge protectionE4
Over-current protectionP5
Communication errorE6
Indoor water overow protectionE9
Mode conictE7
Anti-freezing protectionE2
Defrosting or oil returning for heatingH1
Indoor ambient temperature sensor open/short circuitF1
Evaporator temperature sensor open/short circuitF2
Indoor unit (liquid valve) refrigerant pipe inlet temperature sensor errorb5
Indoor unit (gas valve) refrigerant pipe outlet temperature sensor errorb7
Condenser coil inlet temperature sensor open/short circuit
Condenser coil midway temperature sensor error
Condenser coil outlet temperature senor open/short circuit
Discharge air temperature sensor error
Outdoor ambient temperature sensor error
Module temperature sensor error
Outdoor unit overall error
Error Code
A5
F4
A7
F5
F3
oE
oE
17
Contents
Safety Information .................................................................................................... 1
Install of The Compact Panel Cassette Type Indoor Unit ......................................... 2
Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit ...... 10
Working Temperature Range .................................................................................. 11