13.TECHNICAL INDICATION AND REQUIREMENT ...................................31
Page 5
1. SAFETY PRECAUTION
Read the safety precautions carefully before installing the unit.
Stated below are important safety issues that must be obeyed.
WARNING
CAUTION
Means improper handling may lead to personal death or severe injury.
Means improper handling may lead to personal injury or property loss.
WARNING
Please entrust the distributor or professionals to install the unit.
Installation by other persons may lead to imperfect installation, electric shock or fire.
Adhere to this installation manual.
Imporper installation may lead to electric shock or fire.
Reinstallation must be performed by professionals.
Do not uninstall the unit randomly.
Random uninstalling may lead to abnormal operation, heating or fire of the air condition.
NOTE
1
Do not install the unit in a place vulnerable to leakage of flammable gases.Once
flammable gases are leaked and left around the wire controller, fire may occure.
Do not operate with wet hands or let water enter the wire controller. Otherwise,
2
electric shock may occur.
3
The wiring should adapt to the wire controller current. Otherwise, electric leakage or
heating may occur and result in fire.
The specified cables shall be applied in the wiring. No external force may be applied
4
to the terminal. Otherwise, wire cut and heating may occur and result in fire.
1
Page 6
2. INSTALLATION ACCESSORY
Select the installation location
Don’t install at the place where cover with heavy oil, vapor or sulfureted gas,
otherwise, this product would be deformed that would lead to system malfunction.
Preparation before installation
1. Please confirm that all the following parts you have been supply.
No.Name
Wire controller
1
Installation and owner’s manual
2
Screws
3
Wall plugs
4
5
Screws
Plastic screw bars
6
7
Battery
The connective wires group
8
2. Prepare the following assemblies on the site.
No.
1
2
Name
Switch box
Wiring Tube(Insulating
Sleeve and Tightening
Screw)
Qty.Remarks
3
M4x20 (For Mounting on the Wall)
For Mounting on the Wall
2
M4x25 (For Mounting on switch box)
For fixing on switch box
Optional
Qty.(embeded
into wall)
1
1
(only for reference)
Specification
Remarks
2
Page 7
2. INSTALLATION ACCESSORY
Precaution of install the wire controller
1. This manual provides the installation method of wire controller. Please refer to the
wiring diagram of this installation manual to wire the wire controller with indoor unit.
2. The wire controller working in low voltage loop circuit. Forbid to directly contact the
cable of 220V commercial electricity or of 380V high voltage, and don’t wire this kind
of wire in the said loop; wiring clearance between configured tubes should at the
range of 300~500mm or above.
3. The shielded wire of the wire controller must be grounded reliable.
4. Upon finish the wire controller connection, do not employed tramegger to detect the
insulation.
Page 8
3. INSTALLATION METHOD
1.Wired remote controller structure size figure
120mm18.5mm
123mm
Fig 3-1
2.Remove the upper part of wire controller
Insert a slot screwdriver into the slots in the lower
part of the wire controller (2 places), and remove
the upper part of the wire controller. (Fig.3-2)
NOTICE
The PCB is mounted in the upper part of the wire
controller. Be careful not to damage the board
with the slot screwdriver.
4
46mm
83.5mm
62mm
Slots
Fig 3-2
Page 9
3. INSTALLATION METHOD
3. Fasten the back plate of the wire controller
For exposed mounting, fasten the back plate on the wall with the 3 screws (M4×20)
and plugs. (Fig.3-3)
Back plate
Screws (M4×20)
Fig 3-3
For flush-mounting, fasten the back plate on the switch box with 2 screws (M4×25) and
fasten it on the wall with 1 screw (M4×20). (Fig.3-4)
Back plate
Screw (M4×20)
Screws (M4×25)
Switch box
Fig 3-4
NOTICE
Put on a flat surface. Be careful not to distort the back plate of the wire controller
by overtightening the mounting screws.
5
Page 10
3. INSTALLATION METHOD
4. Battery installation
Fig 3-5
Put the battery into the installationsite and make sure the positive side of the battery
is in accordance with the positive side of installationsite.(See Fig.3-5)
Please set the time corrected on the first time operation. Batteries in the wire
controller can timing under power failure which ensure the time keep right. When
the power restores, if the time displayed is not correct, it means the battery is dead
and replace the battery.
6
Page 11
3. INSTALLATION METHOD
5. Wire the indoor unit
4 methods
1 from the rear;
2 from the bottom;
3 from the top;
4 from the top center.
HA HB
1
1
3
1
HA HB
2
PCB
2
2
PCB
1
HA HB
1 indoor unit
2 notch the part for the wiring to pass through with nippers, etc.
Connect the terminals on the remote controller (HA ,HB), and the terminals of the indoor unit
(HA ,HB). (HA and HB do not have polarity.)
4
PCB
PCB
HA HB
1
2
7
Page 12
3. INSTALLATION METHOD
NOTE: DO NOT allow water to enter the remote control.
Use the trap and putty to seal the wires.
Putty
Trap
Putty
Putty
Trap
Trap
Fig 3-6
6. Reattach the upper part of the wire controller
After adjusting the upper case and then buckle the upper case; avoid clamping the
wiring during installation. (
Fig 3-7
Fig 3-7
)
All the pictures in this manual are for
explanation purpose only.
Your wire controller may be slightly
different .The actual shape shall prevail.
8
Page 13
4. SPECIFICATION
Input voltage
Ambient temperature
Ambient humidity
Wiring specifications
DC 5V/DC 12V
-5~43 °C
RH40%~RH90%
Shielded vinyl cord or cable
Wiring type
Size
2x0.75-2x1.25mm
2
Total length
<50m
9
Page 14
5. FEATURE AND FUNCTION OF THE WIRED
CONTROLLER
Feature:
LCD display.
Malfunction code display: it can display
the error code, helpful for service.
4-way wire layout design, no raised part
at backside, more convenient to place
1Operation mode indication
2Fan speed indication
3Left-right swing indication
4Up-down swing indication
5Faceplate function indication
6 Main unit and secondary unit indication
7Ifeel function indication
Press the Timer button for 3 seconds or more.
The timer display will flash.
Press the button “ + ” or “ - ” to set the date. The selected
date will flash.
+
The date setting is finished and the time setting is prepared after pressing
Timer button or there is no pressing button in 10 seconds.
Press the button “+” or “-” to set the current time.
Press repeatedly to adjust the current time in 1-minute increments.
Press and hold to adjust the current time continuous.
+
ex.Monday AM 11:20
The setting is done after pressing Timer button or there is no
pressing button in 10 seconds.
13
Page 18
9. OPERATION
To start/stop operation
To set the operation mode
Operation mode setting
Press the Power button.
Mode
Room temperature setting
-
LowerRaise
+
14
Press the Mode button to set the operation mode.
(Heat function is invalid for cool only type unit)
Press the button“ + ”or “ - ” to set the room temperature.
Indoor Setting Temperature Range :
17~30 (Depending on models).
Page 19
9. OPERATION
Fan speed setting
Press the Fan speed button to set the fan speed.
(This button is unavailable when in the mode of Auto or Dry)
Fan speed
(Lock)
Room temperature sensor selection
Copy/Ifeel
Press the Ifeel button to select whether the
room temperature is detected at the indoor
unit or the wire controller.
When the ifeel function indication appears,
the room temperature is detected at the wire controller.
Indoor Unit
15
Page 20
9. OPERATION
Child lock function
Press the Lock botton for 3 seconds to activate the child lock
function and lock all buttons on the wire controller.
Press the button again for 3 seconds to deactivate the child
Fan speed
(Lock)
keypad tone setting
Timer
Swing
°C & °F scale selection (on some models)
Back/Turbo
Copy/Ifeel
lock function.
When the child lock function is activated,the mark appears.
Press the buttons Swing and Timer simultaneously for
3 seconds to close the keypad tone.
Press the buttons again for 3 seconds to open the keypad
tone.
Press the buttons Back and Copy simultaneously
for 3 seconds will alternate the temperature display
between the
đē
scale.
16
Page 21
9. OPERATION
Turbo function (on some models)
Back/Turbo
Faceplate function (on some models)
Mode
2. Press the button “+” and “-” to control the lift and drop of the faceplate.
Pressing the “+” button can stop the faceplate,while it is dropping.
Pressing the “-” button can stop the faceplate,while it is lifting.
Press the Turbo button to activate the turbo function.
Press the button again to deactivate the turbo function.
When the turbo function is activated,the mark appears.
1.When the unit is offˈPress the Mode button long to activate
the faceplate function.The mark will flash.
The F2 mark appears when
the faceplate is adjusted.
17
Page 22
9. OPERATION
Swing function (For the unit left & right auto swing models only)
1 Up-Down swing
Swing
Press the Swing button to start up-down swing function.
Press it again to stop.
When the Up-Down swing function is activated,the mark appears.
2 Left-Right swing
Swing
Press the Swing button long to start Left-Right swing function.
Press it again to stop.
When the Left-Right swing function is activated, the mark appears.
18
Page 23
9. OPERATION
Swing function (For the unit without left & right auto swing function models)
Up-Down airflow direction and swing
Swing
Use Swing button to adjust the Up-down airflow direction.
1.Press the button every time, the louver swings 6 degrees.
2.Press and hold the button for 2 seconds,it turns into up-down swing mode,
press ti again to stop.
When the Up-Down swing function is activated,the mark appears. (Not applicable
to all the models)
The operation can refer to the following instructions for the unit with four Up-Down
louvers can be operated individually.
1.Press the Swing button to activate the Up-Down adjusting
louver function.
The mark will flash.(Not applicable to all the models)
2.Pressing the button “+” RUĀā can select the movement
of four louvers.Each time you push the button,the wire
controller select in a sequence that goes from:(the icon
means the four louvers move at the same time.)
-0
-0
-1
3. And then use Swing button to adjust the Up-Down airflow direction of the selected
louver.
-3
-2
-4
Swing
-
+
19
Page 24
10. TIMER FUNCTIONS
WEEKLY timer
Use this timer function to set operating times for each day of the week.
On timer
Use this timer function to start air conditioner operation.The timer operates
and air conditioner operation starts after the time has passed.
Off timer
Use this timer function to stop air conditioner operation.The timer operates
and air conditioner operation stops after the time has passed.
On and Off timer
Use this timer function to start and stop air conditioner operation.The timer
operates and air conditioner operation starts and stops after the time has
passed.
20
Page 25
10. TIMER FUNCTIONS
To set the On or Off TIMER
Timer
1
Press the Timer button to select the or .
No display
Confirm
2
Press the Confirm button and the Clock display is flashing.
3
-
Confirm
4
+
Press the button “ + ” or “ - ” to set the time. After the time is set,
the timer will start or stop automatically.
Press the Confirm button again to finish the settings.
ex.Off timer set at PM 6:00
21
Page 26
10. TIMER FUNCTIONS
To set the On and Off TIMER
22
Timer
1
Confirm
2
3
-
+
4
-
Confirm
5
+
Press the Timer button to select the .
Press the Confirm button and the Clock display is flashing.
Confirm
Press the button “ + ” or “ - ” to set the time of On timer,and
then press the Confirm button to confirm the setting.
Press the button “ + ” or “ - ” to set the time of Off
timer.
Press the Confirm button to finish the settings.
Page 27
11. WEEKLY TIMER
Weekly timer setting
1
Timer
Day of the week setting
2
-
ON timer setting of timer setting 1
3
-
Confirm
Confirm
+
Confirm
+
Press the Timer button to select the .and
then press the Confirm button to confirm.
Press the button “ + ” or “ - ” to select the day of the
week.and then press the Confirm button to confirm
the setting.
Press the button “ + ” or “ - ” to set the time of On
timer.and then press the Confirm button to confirm
the setting.
23
Page 28
11. WEEKLY TIMER
ex.Tuesday time scale 1
Up to 4 timer settings can be saved for each day of the week.It is
conventent if the WEEKLY TIMER is set according to the user’s life style.
Off timer setting of timer setting 1
4
Confirm
-
5
Different timer settings can be setted by repeating step 3 to 4.
Other days in one week can be setted by repeating step 2 to 5.
6
NOTE: ● The weekly timer setting can be returned to the previous step by pressing
Back button.
● The time of timer setting can be delete by pressing Dan off botton
● The current setting will be restored and withdrawn the weekly timer setting
automatically when there is no operation for 30 seconds.
24
+
Press the button “ + ” or “ - ” to set the time of Off
timer.and then press the Confirm button to
confirm the setting.
ex.Tuesday time scale 1
Page 29
11. WEEKLY TIMER
WEEKLY timer operation
● To activate WEEKLY TIMER operation
Timer
● To deactivate WEEKLY TIMER operation
Timer
● To turn off the air conditioner during the weekly timer
Press the Timer button while is displayed on the LCD.
ex.
Press the Timer button while is disappear from the LCD.
1. If press the Power button once and quickly , the air conditioner will turn
off temporarily. And the air conditioner will turn on automatically until the
time of On timer.
ONOFFONOFF
8:0012:0014:0017:0010:00
ex. If press the POWER button once and quickly at 10:00, The air
conditioner will turn on at 14:00.
2. When press the Power button for 2 seconds , the air conditioner will
turn off completely.
25
Page 30
11. WEEKLY TIMER
To set the DAY OFF (for a holiday)
Confirm
1
During the weekly timer, press the Confirm button.
2
-
+
Day off/Del
3
4
Back/Turbo
5
● To cancel˖Follow the same procedures as those for setupDŽ
● Notes:
The DAY OFF setting is cancelled automatically after the set day has passed.
26
Press the button “ + ” or “ - ” to select the day in this
week .
Press the Day off button to set the DAY OFF.
The mark is hidden
ex.The DAY OFF is set for Wednesday
The DAY OFF can be setted for other days by repeating
the steps 2 and 3.
Press the Back button to back to the weekly timer.
Page 31
11. WEEKLY TIMER
DELAY function
During the weekly timer, pressing the Del button once,display " ".
Day off/Del
Copy out the setting in one day into the other day.
● A reservation made once can be copied to another day of the week.
The whole reservation of the selected day of the week will be copied.
The effective use of the copy mode ensures ease of making reservations.
Confirm
1
2
Press this button twice, display " " and wait 3 seconds to confirm.
It means the unit will override 1 hours;
Press this button three times,display " " and wait 3 seconds to confirm.
It means the unit will override 2 hours;
ex. If press the DEL button to select “ ” at 18:05 ˈ
The air conditioner will delay to turn off at 20:05.
During the weekly timer, press the Confirm button.
-
+
Press the button “ + ” or “ - ” to select the day to copy from.
27
Page 32
11. WEEKLY TIMER
Copy/Ifeel
3
4
-
+
Copy/Ifeel
5
The mark flashes quickly
6
7
8
Confirm
Back/Turbo
Other days can be copied by repeating step 4 and 5.
Press the Copy button,the letter “CY” will be
shown on the LCD.
Press the button “ + ” or “ - ” to select the day
to copy to.
Press the Copy button to confirm .
ex. Copy the setting of Monday to Wednesday
Press the Confirm button to confirm the settings.
Press the Back button to back to the weekly timer.
28
Page 33
12. FAULT ALARM HANDING
If the system does not properly operate except the above mentioned cases or the
above mentioned malfunctions is evident, investigate the system according to the
following procedures.
12
Please check the error display of indoor unit and read <<OWNER'S MANUAL>>
if other error code appears.
MALFU N C TIO N & PROT EC T ION DEFIN E
Error of communication between wire controler
and indoor unit
The faceplate is abnormal
DISPLAY
DIGITAL TUBE
F0
F1
13.TECHNICAL INDICATION AND REQUIREMENT
EMC and EMI comply with the CE certification requirements.
29
Page 34
The design and specifications are subject to change without prior notice
for product improvement.Consult with the sales agency or manufacturer
for details.
30
Page 35
Page 36
NOTE CONCERNING PROTECTION OF
ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be
taken to a collection station for the recycling of electrical and electronic devices. The symbol on the
product, the operating instructions or the packaging indicate such disposal procedures. The materials
are recyclable in accordance with their respective symbols. By means of re-use, material recycling or
any other form of recycling old appliances you are making an important contribution to the protection
of our environment. Please ask your local council where your nearest disposal station is located.
INFORMATION CONCERNING USED REFRIGERANT
MEDIUM
This unit is containing fluorinated gases included in the Kyoto protocol. The maintanance and the liquidation must
be carried out by qualified personel.
Type of refrigerant: R410A
The composition of the cooling medium R410A: (50% HFC-32, 50% HFC-125)
The quantity of the refrigerant: please see the unit label.
The value GWP: 2088
GWP = Global Warming Potential
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112
PRODUCER
Producer: SINCLAIR CORPORATION Ltd., 1-4 Argyll St., London W1F 7LD, UK, www.sinclair-world.com
This product was manufactured in China (Made in China).
REPRESENTATIVE, TECHNICAL SUPPORT
NEPA spol. s r.o.
Purkyňova 45
612 00 Brno
Czech republic