Sinclair AMC-14Aa MOBILE SERIES User Manual

Page 1
USER'S MANUAL
MOBILE SERIES
AMC-14Aa
Page 2
Page 3
CONTENT
1. SUMMARY ................................................1
2. WORKING PRINCIPLE.....................................1
3. SAFETY LABELS OF THE UNIT..............................2
4. SPECIFICATIONS ..........................................3
5. STRUCTURE...............................................4
6. OPERATING METHODS ............................... 5 --10
5 --
8--1
7
0
7. NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER.11-- 18 2
8. ACCESSORIES AND INSTALLATION OF DRAINAGE HOSE ..
9. ACCESSORIES OF DRAINAGE WATER .................
19--21
. . .. . . 22
10. CARE AND MAINTENANCE .........................23 --24
11. TROUBLESHOOTING.....................................25
12. USER NOTICES ....................................26 -- 27
13. AFTER SALES SERVICE..................................27
Page 4
SUMMARY
This MOBILE AIR CONDITIONER is a small, movable air conditioner. It possessed the
functions of COOL, HEAT, DRY and the Separate Ventilation, and depends on different places, it
can be moved as will. It is fit for home and office use, especially fit for the house with many rooms.
With the compact configuration, excellent workmanship, elegant appearance, it looks like a standing
Benz car. It is convenient for moving, energy saving, and with low noise.
Note: Please read this manual carefully before operating the unit, the manual is used for reference,
and the technical parameters are subject to change without notice.
WORKING PRINCIPLE
With the help of upper motor, the airflow of indoor pass through the evaporator becomes the
cooled wind, but with the help of lower motor, the airflow of indoor pass through the condenser
becomes the heated wind. There is two duct systems designed in its structure. The heated wind is discharged
by the rear outlet, the cooled wind is discharged by the front outlet, flow-guided by the louver, and it
brings the gentle cooling airflow, and the low temperature environment is maintained.
The Working Principle
Cooled wind
Upper motor
Lower motor
Evaporator
Airflow 1
Capillary
Heated wind
Airflow 2
Condenser
1
Page 5
SAFETY LABELS OF THE UNIT
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol warns you to the potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING." These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow instructions .
All safety messages will tell you what the potential hazard is, how to reduce the chance of injury, and what will happen if the instructions are not followed.
2-
Page 6
--
14000
A MC-14Aa
50Hz
220~240V
SPECIFICATIONS
7.4
10.6/--
1700
-­2450
570
59
47
R410A 800g
840×546×405
870×761×460
D) (mm)
×
W
D) (mm)
×
W
3
/h)
temp.19(the temp of indoor and outdoor are same) with exhaust pipe min length.
4. Noise is tested 1m in front of front air outlet vent under cool air state, it is sound press grade.
3. Max. input power is tested under cooling mode when indoor temp. dry bulb 35 and wet bulb 24.
1. The cooling capacity was tested in the condition of the indoor dry bulb temp.27, wet bulb
2. Heating capacity is tected when indoor temp. dry bulb 20 and wet bulb 12.
changed without notice.
5. Please refer performance parameter on nameplate as standard. The design are subject to be
6. Device is not intended for continuous running
Model
Cooling capacity (Btu/h)
Rated voltage
Heating capacity (W)
Rated frequency
Cooling rated current (A)
Cooling rated power (W)
Max. cooling/heating input current (A)
Max. imput power (W)
Airflow (m
Heating rated power (W)
Refrigerant and charge amount
3
Note:
Weight (N.W.)
Dimension (H×
Noise (sound press)(cool air outlet)dB(A)
Package dimension (H×
Page 7
Front
STRUCTURE
Control panel
Air outlet
Handle
Rear
Upper air inlet grille
Heat air exhaust vent
Power cord
Lower air inlet grille
4
Page 8
※.Usage notice
12″ (50 cm) min.
12(50 cm) min.
OPERATING METHODS
The working range of COOL mode and DRY mode:
16℃-30
Unpack the Air Conditioner
WARNING
Excessive Weight Hazard
Use two or more people to move and install the air conditioner.
Failure to do so can result in back or other injury.
Remove packaging materials
Remove and properly dispose the packaging materials. Remove tape and glue residue from surfaces before
turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers.
Wipe with warm water and dry it.
Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue.
These products can damage the surface of your air conditioner.
Place requirements:
Place the air conditioner on a smooth level floor that strong enough to support the unit.
Allow at least 12 inches (50 cm) of air space on all sides of the unit for good air ventilation.
Place the unit in an area where the temperature will not fall below 18. The coils will be covered with frost at temperatures below 18, and this may reduce performance.
NOTE: The portable air conditioner has wheels for easy movement, but it should only be rolled on smooth and
flat surfaces. Do not attempt to roll the portable air conditioner on carpet or over objects.
5
Page 9
OPERATING METHODS
※.Usage notice
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Power must adopt the rated voltage and special circuit for AC. And diameter of power cord should be big enough.
The portable air conditioner should be connected to a 230V 50Hz, 15 fused 3 prong grounded outlet.
Time-delay fuse or time-delay circuit breaker is recommended to be used.
All wiring must comply with local and national electrical codes and should be installed by a qualified electrician.
If you have any questions, contact a qualified electrician.
Do not use an extension cord.
Do not use an adapter.
6
Page 10
※.Usage Notice
OPERATION METHOD
The wiring must be operated by the professional personnel by
following the national regulation. There must be electric leakage
protect switch and magnetic and heat drop-off air switch that with
enough capacity in fixed circuit. Don't connect earth wire to water
pipe or gas pipe. When the air conditioner is not used, please pull
out the power plug or cut off power supply.
There must be reliable earth
wire in the power supply
Earthing
Water pipe
7
Gas pipe
Page 11
OPERATION METHOD
FUNCTIONS OF DISPLAYER AND PANEL
LCD instruction (dynamic display)
TIMER TIME
FAN mode
COOL mode
SLEEP
DEHU
M
IDIFY
Set temp. display
Functions for control panel and every button
SET TIMER
Temp. set
a
displ
FAN SPEED
Auto mode
y
Fan spedd
LCD screen
Timer On/Off
OPERATION
MODE
Power (On/Off)
SET TEMP.
SLEEP
- 8-
Page 12
OPERATION METHOD
※.Functions of displayer and panel
This unit contains memory function. When power outage occur during operation, the unit stops running. After electrified, the unit would still operates with the operation mode before power outage.
Functions of buttons on control panel:
1. ON/OFF
Turn on or off the unit (press once to turn on, and repress to turn off).
2. MODE
It can make modes(functions) of this unit change in cycle for user to select proper function. Function changes on this mode is: AutoCool
DryFan
3. Fan speed selection button--FAN
When unit is running in FAN, COOL, or HEAT, there are 3 speeds for
options. Press FAN serially can change fan speed in order of: LOWMIDHIGH.
4. Temperature setting button--TEMP
When turning on the unit, under cooling or heating mode, set temp. value would be displayed on control panel. Press and to increase
or decrease set temp. value.
5. TIMER
Press and to set timer time to enable the unit turn on and off in set
time. Timer off time can be set when unit is running, and timer on time
can be set when unit is off (but not power outage). Timer can be set in range of 0.5-24 hours, and press and to adjust.
6. SLEEP
When unit is running, press this button once to begin SLEEP, repress to
quit from SLEEP state. There is no SLEEP state under AUTO mode.
9
Page 13
OPERATION METHOD
※.Functions of displayer and panel
COOLING
DEHUMIDIFYING
FAN
AUTO
HEATING
1). Press MODE to select COOL mode.
2). Press TEMP to set proper indoor temperature in range of 16-30.
3). Press FAN to set proper fan speed, HI / MD / LO.
When cooling, for improve cooling effect, please note:
When there is sunshine from window, please draw curtain to shield. Try not to use other heat source in the room.
Close windows and doors can get a b Press MODE and select DRY, then unit runs in dehumifidy mode. At this time, upper fan motor runs in low speed and is unadjustable.
When the unit is used as dehumidifier, heat exhaust pipe is unnecessary.
1). Press MODE to select FAN mode.
2). Press FAN to select fan speed at HI, MD and LOW.
Press MODE to select AUTO, then mode microcomputer would select FAN,
COOL,HEAT and DEHUMIDIFY automatically according to indoor ambient
to offer a temperature constanting effect in the room.
Press MODE to select HEAT. At this time, compressor and lower fan stop
etter dehumidify effect:
running with only electric heater works. Upper fan runs in set speed.
10
Page 14
NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER
LCD screen
It shows all set contents
SEND key
Press this key to transmit the operation, the screen will show the operation.
HIGH
MODE
AM
SEND
TIME
FAN
SLEEP key Press this key to set SLEEP operation, and press the "Hr" key to adjust the time of t imer off (it can be choose f rom 1-7 h o ur s ), wh en r e pr e ss th is k ey , t h e operation will stop.
TIMER
DRY
Hr
Min
ON/OFF
SLEEP
DRY key
Press this key, the air conditioner will run in DRY mode.
ON/OFF key
Press once to start and press once more to stop the unit.
Make sure to aim the signal port of remote
controller at the signal receiver indicator of front panel.
Only the
AUTO, ON/OFF, SLEEP, SEND
keys
could be used to send the current display operation, the other keys could be used to change the mode.
The other functions please refer to the cooling
only type air conditioner
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc ' will be corresponding
changed to 'OF','+OF' or '-OF'.
11
Page 15
NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER
MODE
TIMER
HIGH
TIME
AM
SEND
DRY
Hr
Min
ON/OFF
FAN
SLEEP
MODE
key Pre s s t h e " M O DE" k ey s tep by s tep, the LCD will display the COOL-FAN-HEAT­AUTO mode, circularly.
TEMP key Press once, the SET TEMP. will decrease
1. Press once, the S ET TEMP. will incr e a s e 1 . T he S ET T EM P . can b e selected from 16-30
(61OF~86OF).
FAN key The switchover of FAN mode are HIGH­MD-LOW.
TIMER key Press the key to select the SET TIMER mode or the TIME mode. When select the "SET TIMER" mode, the LCD will display the time of the SET TIMER mode, while select the "TIME" mode, the LCD will display the current time.
POWER OFF
In case of the power off during the operation, all options will be
ceased.
If need to resume the operation, please repress the "SEND" key. If there is malfunction in the operation procedure, or wrong operation due to the thunder, please pull out the power plug, and reinsert it,
then press the "SEND" key.
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc 'will be corresponding
changed to 'OF','+OF' or '-OF'.
12
Hr/Min key When the unit is running in the "TIME" mode, pres s "Hr" once, the number w ill inc rease 1, press "Min" once, the number will increase 1. When the unit is running in the "SET TIMER" mod e , pr e s s t h e ke y on c e be t w e en 0 - 7 , t h e number of time will increase 0.5, press the key once above 8, the number of time will increase
1. When the unit is running in "SLEEP" mode, press the "Hr" key once, the time interval will increase 1 hour, and will circulate from 1 to 7 hour(s).
Page 16
18 C
HIGH
AM
TIME
COOL MODE OPERATION
1. After inserting the batteries, press
"ON/OFF" key to start the unit.
2. Press "MODE" key, to choose "COOL"
mode.
MODE
TIMER
SEND
DRY
Hr
Min
ON/OFF
FAN
SLEEP
COOL
3. Press "FAN" key, to set fan speed.
4. Press "TEMP" key, to set the desired
temp.
5. Press "SEND" key, send the operation
to the unit.
● When temperature of room sensor is higher
than the set temp, compressor runs, the unit starts cooling operation.
● When temperature of room sensor is lower
than the set temp, compressor stops, the unit runs in "FAN" mode.
● The set temp should be in range of 16~30.
(61OF~86OF).
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc 'will be corresponding
changed to 'OF','+OF' or '-OF'.
13
Page 17
HEAT MODE OPERATION
HIGH
TIME
AM
(only for cooling/heating type units)
1. After inserting the batteries, press
"ON/OFF" key to start the unit.
2. Press "MODE" key, to choose "HEAT"
mode.
3. Press "TEMP" key, to set the desired
temp.
MODE
TIMER
SEND
ON/OFF
DRY
Hr
Min
FAN
SLEEP
HEAT
The compressor and lower motor stop running, only PTC is running, the upper motor is running at the set fan speed.
NOTE: When using Fahrenheit remote controller the sign '
changed to 'OF','+OF' or '-OF'.
O
c', '+Oc' or '-Oc 'will be corresponding
4. Press "FAN" key, to set fan speed.
5. Press "SEND" key to transmit the operation to the unit.
● When the air conditioner was disturbed, the
remote controller can't work once in a while,
only to pull out the power plug, after reinserting
it, it can be operated.
● Check if the voltage of the batteries is full or not, otherwise to replace the worn batteries.
● When t h e L C D of the r e mote c o ntro l l e r
couldn't display all set contents clearly, or
th e s e t o ptions co u ldn't be rece ived, plea s e
replace the batteries.
14
Page 18
DRY MODE OPERATION
1.After inserting the batteries, press
"ON/OFF" key to start the unit.
MODE
TIMER
18 C
HIGH
TIME
AM
SEND
DRY
Hr
Min
ON/OFF
2.Press "DRY" key, to set "DRY" mode, when repress the key, it will run in original operation.
3.Press "TEMP" key, to set desired temp.
FAN
SLEEP
4.Press "FAN" key, to set fan speed.
5.Press "SEND" key to transmit the operation to the unit.
DRY
When the unit is in DRY mode, the compressor
is protected, the fan motor runs at low fan speed.
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc 'will be corresponding
changed to 'OF','+OF' or '-OF'.
15
Page 19
18 C
HIGH
AM
SLEEP
TIME
SLEEP MODE OPERATION
1. After inserting the batteries, press
"ON/OFF" key to start the unit.
2. Press "MODE" key, to select the
operation mode.
3. Press "TEMP" key, to set desired
temp.
MODE
TIMER
SEND
DRY
Hr
Min
ON/OFF
FAN
SLEEP
4. Press "FAN" key to set fan speed.
5. Press "SEND" key to transmit the operation to the unit.
6. Press "SLEEP" key, to set SLEEP
operation, when press once more it
will stop.
● When the unit is running in SLEEP mode, press "Hr"
key to set timer on, the interval is 1-7 hours.
● When the unit is running in SLEEP mode, according to
the time changes, it could adjust the original set temp
automatically to save energy and make a comfortable
sleeping.
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc ' will be corresponding
changeed to 'OF','+OF' or '-OF'.
16
Page 20
AUTO MODE OPERATION
MODE
TIMER
HIGH
TIMER
SEND
DRY
Hr
Min
ON/OFF
FAN
SLEEP
1. After inserting the batteries, press
"ON/OFF" key to start the unit.
2. Press "MODE" key, select "AUTO" mode, according to the room temp, the microcomputer will adjust the turn on or turn off of the compressor and fan
motor automatically to offer comfortable
effect.
3. Press "SEND" key to transmit the operation to the unit.
AUTO MODE
● According to the room temp, the microcomputer will
adjust the turn on or turn off of the compressor automatically
to offer comfortable effect.
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc ' will be corresponding
changed to 'OF','+OF' or '-OF'.
17
Page 21
HIGH
TIMER
TIMER MODE OPERATION
1. When the unit is running, press "TIMER"
key, to set the TIMER operation.
2. Press "Hr/Min" key, to set the TIMER
ON, it can be selected in the range of
1-18 hours.
MODE
TIMER
SEND
DRY
Hr
Min
ON/OFF
FAN
SLEEP
3. Press "SEND" key to transmit the operation to the unit.
4. Press "SLEEP" key, then press the "Hr/Min"
key to set the TIMER OFF, it could be
selected in the range of 1-7 hours.
After the SET TIMER ON, the unit turns off at once, when the set
time arrived, the unit will run in original mode.
Press "TIMER" key, to select "TIME", the screen will display the
current time, press "Hr/Min" key to adjust the number of current hour or minute.
When pressing the "SLEEP" key to set the "SLEEP" mode, the "SET
TIMER" mode will be canceled, when selecting the "SET TIMER" mode, the "SET SLEEP" mode will be canceled.
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc ' will be corresponding
changed to 'OF','+OF' or '-OF'.
18
Page 22
ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE
 Length range of exhaust pipe should be 500mm-2000mm.
It is recommended to use it with shortest length.
 When installing, exhaust pipe should be as flat as possible.
Don't prolong the pipe or connect it with other exhaust pipe, or it would cause abnormal operation.
Correct installation is as shown in figure (When installing it on wall, height of hall should be about 40cm-130cm from floor).
19
Page 23
ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE
If the pipe are to be bent, please install it by considering
following dimension.
55cm
55cm
Wrong installation is shown in following figure (If the pipe is bent too much, it would easily cause malfunction.)
20
Page 24
ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE
PARTS INCLUDED
Front plastic pipe end
Window Exhaust Adapter
Rear plastic pipe end
ACCESSORIES OF DRAINAGE WATER
Accessories of drainage hose incluse:
Flexible Exhaust Hose
Drainage hose
                                                            Bolt
Pipe clip
Drainage capFixing clip
21
Page 25
ACCESSORIES OF DRAINAGE WATER
Installation method
1. Take out L drainage cap from drainage point at chassis.
2. Install drainage cap on drainage hose, and it should be inserted tightly without loosing.
3. Fix fixing clip for drainage hose at rear plate by bolts.
Note:
 Do install drainage hose before turning on the unit to prevent water
from making floor and carpet dirty.
 The L drainage cap taken from drainage point should be stored well for future use.
A
A. Drain port
B
B . Drain cap
B
A
A. Drain port B . Attac h drain hos e clip with s crew provided.
4. Insert one end of drainage hose to drainage point to the end and assembly
pipe clip to prevent water leakage.
5. Fix drainage hose at fixing clip.
D
A
Drainage
method:
B
C
When using COOL and DRY, condensate would be gathered in flume. When
flume filled, buzzer would sound for 8 times and LCD displays error code H8.
A. D rain plug
E
B . Drain port C . Drain hose
D. C lamps
E . Drain hos e clip
The whole unit would stop working till water filled removed and resume running
after compressor had stopped for 3 min. Take out the cap on drainage hose, take
out the hose from fixing clip and drain out water in the flume. After drainage, put
the cap on hose to present water leakage, and fix drainage hose on fixing clip.
Important: Drain the water only if the unit shuts down with display error code “H8”
(Full water tank) or drain the water only if the unit is going to be turned off for long period of time. If you drain the water constantly,
during normal operation, the unit
could be damaged.
22
Page 26
CARE AND MAINTENANCE
Mobile unit
Clean the air filter
There are wheels at the bottom
of the unit, according to the
demand, it can be moved in the
room very conveniently.
Air inlet grille
WARNING
Before maintenance, please
pull out the power plug and cut
off power supply to avoid
electric shock.
Performance of the unit will decrease if there are too much dust
gathered, thus clean it at least once two weeks.
Disassembly
Clean
Filter supporter
Draw out filter supporter and take out filter
Wash the filter solely, spray(like the spray in bath)
and shake it, or immerse it into the gentle soap water,
then dry it in shade.
23
Page 27
CARE AND MAINTENANCE
Clean the air
conditioner
Please use a cloth that slightly moistened with water whose temperature is below 40(
dirt. Do not use gasoline, diesel oil or the congeneric substance to clean
the unit. Before cleaning, please pull out the power plug.
or the soap water or the water with cleanser) after wiping the
GAS
24
Page 28
TROUBLESHOOTING
If malfunction occur, please check the following before maintenance:

The air conditioner doesn't start.
The LCD displays the number of time, but it doesn't work.
Although it was set to COOL mode, there is no cool wind.
Although it was set the DRY mode, there is no cool wind.
Troubles
Possible Causes
The power supply is not connected well. The power plug is not inserted tightly. There is the malfunction of power plug or socket. The fuse is broken.
Is the TIMER ON in operation?
1. The room temp. is lower than the set temp.
2. The evaporator frosts.
1. The evaporator frosts.
1. Insert the power plug tightly.
2. Replace the power plug or socket.
3. Ask for the maintenance man to replace the fuse.
Cancel the "SET TIMER" operation or to wait the auto running.
1. This is the normal phenomenon.
2. Unit is running in defrosting operation, it will resume running in original operation after defrosting.
1. Unit is running in defrosting operation,
it will resume running in original
operation after defrosting.
Solutions
The LCD displays"E5".
The LCD displays"H8".
1. Low voltage over current
protection.
The water tank gets full.
25
Cut off power supply, after 10 minutes, turn on the unit, if "E5" still be displays, please inform the maintenance man to maintain.
1. Drain out water through
drainage hose.
2. If the malfunction still exists, please inform the maintenance man to maintain.
Page 29
USER NOTICES
Location
Others
●  Do not install the unit in the hermetic place, and keep well ventilation,
to
avoid malfunction occurs.
● Do not install the unit at where it will be exposed to direct sunlight,
in order to avoid fading and efficiency reducing.
● Do not install the unit in the moist place, it can cause electrical leakage.
● Please do not install the unit to the following places:
The places with gas, fire, oil or where it will cause malfunction.
Please pay attention to the people of following:
1). Young children, patient.
2). The people who are hard to express themselves.
3). The people who is very tired, drunk or the one who had taken
soporifics.
● Do not step on or put anything on the top of the unit, it will slop and
can cause malfunction.
● Do not apply the cold wind to the body for a long time, it can cause
health problems.
● The unit should be placed about 1m or more away from TV, or it will
be effected by the electromagnetic wave.
●  The air inlet/outlet can't be blocked by obstruction, or it will cause
malfunction.
● Do not insert hands or stick into the air inlet or outlet, especially pay
more attention to young children, or it can cause the accident easily.
●  AMC-14Aa can be connected only to a supply with system impedance
no more than 0.36ohm. In case necessary,
please consult your supply authority for system impedance information.
●  If the supply cord is damaged, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
●  The appliance must be positioned so that the plug is accessible.
●  Static press in pipeline ranged from -25Pa to 0Pa.
●  Rated parameter for FUSE: AC 250V, 3.15A; AC 250V, 1A
26
Page 30
●  The min. distance between flammable surface should be 150mm.
Specific parameter for PTC is 240V/1200W, and its installation position is
inside component of upper twyer.
●  When water level switch works for water filled, water inside the tank is 1.12L.
Do not incline or overturn. If the abnormal phenomenon occurred, please pull
out the power plug at once, and inform dealer to check and maintain.
 Do not use the insecticide or other sprays, it can cause deformation or crack.
Check the User Manual for the sentences below and the marking label for the
"garbage bin".
Meaning of crossed-out wheeled dustbin:Do not dispose of electrical appliances
as unsorted municipal waste, use separate collection facilities.
Contact you local government for information regarding the collection systems
available.
If electrical appliances are disposed of in landfills of dumps, hazardous substances
can leak into the groundwater and get into the food chain,damaging your health and well-being.
When replacing old appliances with new ones,the retailer is legally obligated to
take back your old appliance for disposal at least free of charge.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal there are several possibilities:
a) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
b) When buying a new product, the retailer will take back the old product at least
free of charge. c) The manufacturer will take back the old appliance for disposal at least free of
charge to the user.
d) As old products contain valuable resources, they can be sold to scrap metal dealers.
Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.
DISPOSAL:Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
AFTER SALES SERVICE
If any quality problems or any other problems exist, please contact with
the local dealer.
27
Page 31
Loading...