Sinclair AMC-09C User Manual

Page 1
USER'S MANUAL
AMC-09C
MOBILE SERIES
Page 2
Page 3

...............................................
.......................................
.
.....................................
.
..............................................
............................................
22
...........................................
.........................................
24
23
25
2
1
3
..................................
..................................
..................................
..................................
.
.................................
17-19
20-21
.........................................
11
13
14
15
16
.................
4-8
9-10
...............
CONTENTS
Summary
Working principle Models & specifications
Structure
Operating methods
Names and Functions of the Remote Controller
COOL mode operation
DRY mode operation
SLEEP mode operation
AUTO mode operation
TIMER mode operation
Installation guide for castor, drainage pipe and air exhaust accessory
Care and Maintenance
Trouble shooting
User notices After service
Circuit diagram
...................................
.........
.....................................
Page 4
SUMMARY
1
This MOBILE AIR CONDITIONER is a small, moveable air conditioner. It possessed the functions of COOL, HEAT, DRY and the Separate Ventilation, and depends on different places, it can be moved as will. It is fit for home and office use, especially fit for the house with many rooms.
With the compact configuration, excellent workmanship, elegant appearance, it looks like a standing Benz car. It is convenient for moving, energy saving, and with low noise.
Note: Please read this manual carefully before operating the unit, the manual is used for reference, and the technical parameters are subject to change without notice.
WORKING PRINCIPLE
With the help of upper motor, the airflow of indoor pass through the evaporator becomes the cooled wind, but with the help of lower motor, the airflow of indoor pass through the condenser becomes the heated wind. There is two duct systems designed in its structure. The heated wind is discharged by the rear outlet, the cooled wind is discharged by the front outlet, flow-guided by the louver, and it
brings the gentle cooling airflow, and the low temperature environment is maintained.
The Working Principle
Cooled wind
Upper motor
Lower motor
Evaporat or
Airflow 1
Airflow 2
Capillar y
Heated wind
Condenser
Page 5
2
MODELS AND SPECIFICATIONS
Note:
1. The
noise was tested when the unit is running in cooling wind mode, 1 meter away from the front
outlet, dehumidifying capacity.
2.The technical parameters are subject to be changed without notice. Please refer to those listed on
Model AMC-09C Cooling Capacity(W) 2600W Power Source 220-240V ~ 50Hz Rated Input Current(A) 5.3 Rated Power Input(W) 1200 Flow Volume(m3/h) 430 Sound Press Level dB(A) 55
Refrigerant R407C Net Weight(Kg) 31 Dimension(Body)(H× W ×D)(mm
840×450×370
Dimension(Package)(H× W×D)(mm)
880×685×425
nameplate of the unit.
3. Device is not intended for continuous running
Page 6
3
STRUCTURE
Control panel
Air outlet
Handle
Lower air inlet
Front
Rear
Upper air inlet grille
Power cable
Air exhaust outlet
Lower air inlet grille
Page 7
  
OPERATING METHODS
4
The working range of COOL mode is 16-35, the working range of DRY mode is 16-35℃.
When operating, the unit should be placed on the horizontal place and more than 50cm away from the wall or other obstructions.
The working range of COOL
mode and DRY mode
Location conditions
Power supply Before the unit is power-on, please check the following:
The power supply voltage
6%.
● The lead wire is suitable for the start-up current of more than 20A,
to avoid the voltage decline when the unit starts suddenly.
● The power plugs and the
sockets can be supported by the current
that is more than 16A.
● The thread section of the lead wires and any continued use lead wire
is no less than 2.5mm2.
● If the power supply cord is damaged, replace it by the special
power supply cord.
● 
If the power supply is needed to replace or maintain, please
contact with the dealer and ask for the professional personnel to do the repairing work.
● The air conditioner must be safety earthed. Earth wire must be connected to the special device of the building. That is for providing
good earthing for the air conditioner.
Page 8
OPERATING METHODS
Can not use steel wire or brass wire to replace fuse, the capability
of fuse must be appropriate.
In order to avoid damage to power cord and electrical leakage, do not fix the power supply on the knife edge or sharp object.
The wiring must be operated by the professional
and according
to the national regulations. In fixed circuit, there must be electricity
leakage protection switch of enough power capacity and 16A
thermal-
magnetic breaker air switch with enough space, the earth wire can't be
connected to water pipe or gas pipe. When the air conditioner is not
used, please pull out the power plug or cut off
power supply.
5
There must be reliable ground wire in the power supply
Earthing
Water pipe
Gas pipe
Page 9
6
OPERATING METHODS
LCD instruction (dynamic display)
Names and Functions- Remote Controller
ON/ OFF
MODE
FAN SPEED
LCD screen
SET TEMP.
SET TIMER
SET SLEEP
Remote Control window
Page 10
7
OPERATING METHODS
Control panel and the function
1. "ON/ OFF "key Press once to start and press once more to stop the unit.
2."MODE" key
Press this button to change operation mode in order of:
FAN → COOL → DRY → AUTO → FAN
3 "FAN SPEED" key When the unit is running in "FAN", "COOL" and "HEAT" mode, there are 3 kinds of fan speeds to be selected, press "FAN SPEED" key to choose between "LOW → MD → HIGH".
4."SET TEMP" key
When turn on the air conditioner, in the "COOL","HEAT" mode, the control panel will display the set temp. Press """"to increment or to decrement the set temperature.
5. "SET TIMER" key Press"""" key to set the time for timer on or timer off. When the unit is running, you could set the timer off, the unit will stop running; When the unit is stop running (not power off ), set timer on, and the time interval that being set will be 0.5-24 hour(s), press """" key to adjust.
6. "SET SLEEP" key
When the unit is running, press once to set "SLEEP" operation, repress it, the unit will stop the "SLEEP" operation. There is no "SLEEP" operation in "AUTO" mode.
Page 11
8
OPERATING METHODS
1). Select a place that near door and window, install the exhaust duct (the installation
method please refer to P19), put the exhaust duct out of the door, do not close the door and window tightly, leave enough space for air flow, for example, open the window or door to keep a good ventilation.
2). Press "MODE" key to select "COOL" mode.
3). Press "TEMP" key to set the suitable temp.16-30.
4). Press "FAN" key to select the suitable fan speed, (HIGH, MD, LOW). When the unit is running in COOL mode, in order to keep a good cooling effect,
please pay more attention to:
1). If there is the direct sunlight at the window, please use the curtain to shield . 2). Do not use other heat sources in the air conditioning room.
Please close the door and window to obtain a better dehumidifying effect:
Press "MODE" key, select "DRY" mode, the unit will run in the "DRY" mode, at the
same time, the upper motor is running at the low speed, it is not adjustable.
When the air conditioner is used as dehumidifier, it is no need to install the exhaust duct.
1). Press "MODE" key, to select "FAN" mode.
2). Press "FAN SPEED" key to choose from the HIGH, MD, LOW fan speed options.
Press "MODE" key to select "AUTO" mode, the microcomputer process will automatically choose COOL, DRY, HEAT mode, for ensuring the indoor constant
temperature efficiency. Press "MODE" key to choose "HEAT" mode, at the same time, compressor and lower
motor stop running, only PTC is running, the upper motor is running at the set fan speed.
COOL mode
CAUTION
DRY mode
CAUTION
FAN mode
AUTO mode
HEAT mode
When in cooling or dehumidifying mode, the dew water will be drained into the tank.
When the tank gets full, the indicator will flash, and the buzzer will sound eight times,
LCD window shows error code H8at the same time the unit stops running.
WATER
Cut off power supply, move the appliance to a suitable place to pull out the plug and pour out the water in tank. When water is drained out completely, re-insert the plug back into the drainage pipe to avoid dew water leakage. (As figurre shown below Fig 1)
When
restarting the appliance,it must be set again.
METHOD OF
DRAINAGE
If the appliance is placed in a position admitting to drain water, you also can connect the drain hose to the drain port to drain water.
DRAINAGE
Drainage Pipe
Rubber Plug
Fig 1
Fig 2
Fig 3
(As figurre shown below Fig 2--Fig 3)
(61OF~86OF).
Page 12
9
NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER
LCD screen
It shows all set contents
ON/OFF
HIGH
TIME
AM
MODE
FAN
TIMER
DRY
Hr
SLEEP
Min
SLEEP key Pres s this k ey to s et SLEEP operation, and press the "Hr" key to adjust the time of ti mer off (it can b e c hoose fr om 1 -7 h o u r s ) , w h e n r e p re s s t h i s k e y, t h e operation will stop.
ON/OFF key
Press once to start and press once more
to stop the unit.
DRY key
SEND key
Press this key to transmit the operation, the screen will show the operation.
Press this key, the air conditioner will run in DRY mode.
Make sure to aim the signal port of remote
controller at the signal receiver indicator of front panel.
Only the
AUTO, ON/OFF, SLEEP, SEND
keys
could be used to send the current display operation, the other keys could be used to change the mode.
The other functions please refer to the cooling
only type air conditioner
SEND
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc ' will be corresponding
changed to 'OF','+OF' or '-OF'.
Page 13
10
In case of the power off during the operation, all options will be
ceased.
If need to resume the operation, please repress the "SEND" key. If there is malfunction in the operation procedure, or wrong operation due to the thunder, please pull out the power plug, and reinsert it,
then press the "SEND" key.
POWER OFF
HIGH
TIME
AM
MODE
FAN
SEND
TIMER
DRY
Hr
SLEEP
Min
NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER
MODE
key Pr e s s the "MO D E " key ste p by s t ep, t h e LCD will display the COOL-FAN-HEAT­AUTO mode, circularly.
TEMP key Press once, the SET TEMP. will decrease
1. Press o nce, the SE T TE MP. will incr e a s e 1 . T h e S E T T E M P . c a n b e selected from 16-30
FAN key The switchover of FAN mode are HIGH­MD-LOW.
TIMER key Press the key to select the SET TIMER mode or the TIME mode. When select the "SET TIMER" mode, the LCD will display the time of the SET TIMER mode, while select the "TIME" mode, the LCD will display the current time.
Hr/Min key When the unit is running in the "TIME" mode, pres s " Hr" o nce, the nu mber will increase 1 , press "Min" once, the number will increase 1. When the unit is running in the "SET TIMER" mo d e , press the k e y once betwe e n 0-7, t h e number of time will increase 0.5, press the key once above 8, the number of time will increase
1. When the unit is running in "SLEEP" mode, press the "Hr" key once, the time interval will incre ase 1 ho ur, and will circu late from 1 to 7 hour(s).
ON/OFF
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc 'will be corresponding
changed to 'OF','+OF' or '-OF'.
(61OF~86OF).
Page 14
11
COOL MODE OPERATION
COOL
● When temperature of room sensor is higher
than the set temp, compressor runs, the unit starts cooling operation.
● When te mpe rature of r oom sensor is lower
than the set temp, compressor stops, the unit runs in "FAN" mode.
● The set temp should be in range of 16~30.
HIGH
TIME
AM
MODE
FAN
SEND
TIMER
DRY
Hr
SLEEP
Min
18 C
1. After inserting the batteries, press
"ON/OFF" key to start the unit.
2. Press "MODE" key, to choose "COOL"
mode.
3. Press "FAN" key, to set fan speed.
4. Press "TEMP" key, to set the desired
temp.
5. Press "SEND" key, send the operation
to the unit.
ON/OFF
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc 'will be corresponding
changed to 'OF','+OF' or '-OF'.
(61OF~86OF).
Page 15
13
DRY MODE OPERATION
When the unit is in DRY mode, the compressor is protected, the fan motor runs at low fan speed.
DRY
HIGH
TIME
AM
MODE
FAN
SEND
TIMER
DRY
Hr
SLEEP
Min
18 C
5.Press "SEND" key to transmit the operation to the unit.
1.After inserting the batteries, press
"ON/OFF" key to start the unit.
2.Press "DRY" key, to set "DRY" mode, when repress the key, it will run in original operation.
3.Press "TEMP" key, to set desired temp.
4.Press "FAN" key, to set fan speed.
ON/OFF
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc 'will be corresponding
changed to 'OF','+OF' or '-OF'.
Page 16
14
SLEEP MODE OPERATION
● When the unit is running in SLEEP mode, press "Hr"
key to set timer on, the interval is 1-7 hours.
● When the unit is running in SLEEP mode, according to
the time changes, it could adjust the original set temp automatically to save energy and make a comfortable sleeping.
1. After inserting the batteries, press
"ON/OFF" key to start the unit.
2. Press "MODE" key, to select the
operation mode.
3. Press "TEMP" key, to set desired
temp.
4. Press "FAN" key to set fan speed.
5. Press "SEND" key to transmit the operation to the unit.
6. Press "SLEEP" key, to set SLEEP
operation, when press once more it
will stop.
HIGH
TIME
AM
MODE
FAN
SEND
TIMER
DRY
Hr
SLEEP
Min
18 C
SLEEP
ON/OFF
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc ' will be corresponding
changeed to 'OF','+OF' or '-OF'.
Page 17
15
AUTO MODE OPERATION
● According to the room temp, the microcomputer will
adjust the turn on or turn off of the compressor automatically to offer comfortable effect.
AUTO MODE
HIGH
TIMER
MODE
FAN
SEND
TIMER
DRY
Hr
SLEEP
Min
1. After inserting the batteries, press
"ON/OFF" key to start the unit.
2. Press "MODE" key, select "AUTO" mode, according to the room temp, the microcomputer will adjust the turn on or turn off of the compressor and fan motor automatically to offer comfortable effect.
3. Press "SEND" key to transmit the operation to the unit.
ON/OFF
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc ' will be corresponding
changed to 'OF','+OF' or '-OF'.
Page 18
16
TIMER MODE OPERATION
1. When the unit is running, press "TIMER"
key, to set the TIMER operation.
2. Press "Hr/Min" key, to set the TIMER
ON, it can be selected in the range of
1-18 hours.
3. Press "SEND" key to transmit the operation to the unit.
key to set the TIMER OFF, it could be
selected in the range of 1-7 hours.
4. Press "SLEEP" key, then press the "Hr/Min"
After the SET TIMER ON, the unit turns off at once, when the set
time arrived, the unit will run in original mode.
Press "TIMER" key, to select "TIME", the screen will display the
current time, press "Hr/Min" key to adjust the number of current hour or minute.
When pressing the "SLEEP" key to set the "SLEEP" mode, the "SET
TIMER" mode will be canceled, when selecting the "SET TIMER" mode, the "SET SLEEP" mode will be canceled.
HIGH
TIMER
MODE
FAN
SEND
TIMER
DRY
Hr
SLEEP
Min
ON/OFF
NOTE: When using Fahrenheit remote controller the sign '
O
c', '+Oc' or '-Oc ' will be corresponding
changed to 'OF','+OF' or '-OF'.
Page 19
17
INSTALLATION GUIDE FOR CASTOR, DRAINAGE PIPE AND AIR EXHAUST ACCESSORY
THE AIR EXHAUST
DUCT MOUNTING
METHOD
1.Install the adjutable window silder kit or drill a hole at the nearest window.
2.Fix the square end of the exhaust duct to the exhaust terminal of the unit as depicted in Fig 4.
3.Put the other end (discharge) to the window as depicted in Fig 5 or Fig 6.
Attention:
The length of the air exhaust must be between 500mm-­2000mm.
Plastic Pipe End
Middle Plastic Pipe End
Rear Clip B
Fig 4
Front Plastic Pipe End
Pipe ( 131)
Ø
Page 20
18
INSTALLATION GUIDE FOR CASTOR, DRAINAGE PIPE AND AIR EXHAUST ACCESSORY
CAUTION
1.In order to correctly installing the air exhaust duct please
contact your local dealer for the service.
2.When mounting, try to keep the square end of the exhaust duct horizonal.
3.Don't add or connect other pipes to it, otherwise it will cause mechanical malfunction.
Window kit
Rear Clip B
Window
Plastic Pipe End
Hole( 132mm)
Window Or wall
Fig 5
Fig 6
Ø
Page 21
19
THE INSTALLATION GUIDE FOR ACCESSORY OF EXHAUST DUCT
If the exhaust duct requires bend, please refer to the following
installation dimensions
CAUTION
The wrong mounting diagram (if the exhaust duct is bent too great, it could cause malfunction easily.)
55cm
65cm
55cm
Page 22
20
CARE AND MAINTENANCE
There are castors at the bottom of the unit, according to the demand, it can be moved in the room very conveniently.
Hook Hook
Air inlet grille
Before maintenance, please pull out the power plug and cut off power supply to avoid
electric shock.
If the usage environment of the unit has lots of dust, the cleaning of air filter should be more frequently.
Disassembly and Cleaning:
Press two hooks of the grille, take
off the cover of air inlet grille, then take
Wash the filter solely, to spray( like
the spray in bath) and to shake the filter,
or to immerse filter into the gentle soap
water, then dry it in shade.
WARNING
The mobile air conditioner
WARNING
Clean the air filter
(Recommended once
every three weeks)
NOTE:
Never use water above 45 to wash the filters, or it could cause deformation or discoloration.
out the air filter.
Page 23
21
CARE AND MAINTENANCE
Clean the air
conditioner
Please use a cloth that slightly moistened with water whose temperature is below 40(
or the soap water or the water with cleanser) after wiping the
dirt. Do not use gasoline, diesel oil or the congeneric substance to clean
the unit. Before cleaning, please pull out the power plug.
GAS
Page 24
22
TROUBLE SHOOTING
If malfunction occur, please check the following before maintenance:

Troubles
The air conditioner doesn't start.
The LCD displays the number of time, but it doesn't work.
Although it was set to COOL mode, there is no cool wind.
Although it was set the DRY mode, there is no cool wind.
The LCD displays"E1".
The LCD displays"H8".
Possible Causes
The power supply is not connected well. The power plug is not inserted tightly. There is the malfunction of power plug or socket. The fuse is broken.
Is the TIMER ON in operation?
1. The room temp. is lower than the set temp.
2. The evaporator frosts.
1. The evaporator frosts.
1. Power supply is unstable.
2. Malfunction occurs.
The water tank gets full.
Solutions
1. Insert the power plug tightly.
2. Replace the power plug or socket.
3. Ask for the maintenance man to replace the fuse.
Cancel the "SET TIMER" operation or to wait the auto running.
1. This is the normal phenomenon.
2. Unit is running in defrosting operation, it will resume running in original operation after defrosting.
1. Unit is running in defrosting operation,
it will resume running in original
operation after defrosting.
Cut off power supply, after 10 minutes, turn on the unit, if "E1" still be displays, please inform the maintenance man to maintain.
1. Pour out water in the tank (please see the fig in P8).
2. If the malfunction still exists, please inform the maintenance man to maintain.
Page 25
23
USER NOTICES
●  Do not install the unit in the hermetic place, and keep well ventilation,
to
avoid malfunction occurs.
● Do not install the unit at where it will be exposed to direct sunlight,
in order to avoid fading and efficiency reducing.
● Do not install the unit in the moist place, it can cause electrical leakage.
● Please do not install the unit to the following places:
The places with gas, fire, oil or where it will cause malfunction.
Location
Others
Please pay attention to the people of following:
1). Young children, patient.
2). The people who are hard to express themselves.
3). The people who is very tired, drunk or the one who had taken
soporifics.
● Do not step on or put anything on the top of the unit, it will slop and
can cause malfunction.
● Do not apply the cold wind to the body for a long time, it can cause
health problems.
● The unit should be placed about 1m or more away from TV, or it will
be effected by the electromagnetic wave.
●  The air inlet/outlet can't be blocked by obstruction, or it will cause
malfunction.
● Do not insert hands or stick into the air inlet or outlet, especially pay
more attention to young children, or it can cause the accident easily.
Page 26
24
AFTER SERVICE
● If any quality problems or any other problems exist, please contact
with the local dealer.
USER NOTICES
●  Do not incline or overturn. If the abnormal phenomenon
occurred, please pull out the power plug at once, and inform the
dealer to check and maintain.
●  Do not use the insecticide or other sprays, it can cause
deformation or crack..
Page 27
AMC-09C
25
The circuit diagrams of all above are for reference, they are subject to be changed without notice.
CIRCUIT DIAGRAM
Loading...