SImx MANROSE FAN5875 Installation Instructions Manual

• The power cable of this product must withstand a minimum 10A load.
The main supply and interconnecting cables required for installation
of this unit are not included.
This unit must be properly grounded.
The disconnection of the product is acheived by incorporating a
switch in the fixed wiring in accordance with the wiring rules. The heater must be isolated from the power by means of a disconnection switch with a contact separation of at least 3mm.
The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
2. Ducting
Put one end of the 100mm diameter ducting into the vent hole and connect to grille or cowl with one duct clip included. Seal space around the grille using a suitable sealant. An eggcrate grille is includ­ed in the package to be used if installed in soffit. If installed in wall a weather proof cowl should be used (DCT0018).
INSTALLATION
A few minutes of planning can make a big difference to the installation time and also to your satisfaction with the function of the unit.
1. Cutting a vent
Locate the exterior grille location on a wall or soffit, then cut a 105 mm diameter hole to install grille/cowl.
Note: The length of duct is 3.0m. Make sure that from the centre of the units installated position there must be a distance within 3.0m to the outside vent.
3. Suitable location
The heater must be installed at least 2.1m above the floor. The heater is most effective when you are standing directly beneath it,
W
all venting shown
wall
sealant
ducting
bathroom heater
ceiling joist
ceiling
fascia
duct clip
Terminal Blocks
4. Prepare the ceiling
Use this template to mark the hole outline on the ceiling. Make sure a distance between the edges and wall is no less than 250mm. The distance from the ceiling board to the rooftop must be a minimum of 220mm.
5. Remove the fascia
Remove 4 screw covers at 4 corners of the fascia. Remove the screws hidden behind. Remove the fascia.
6. Wiring
Open the terminal block cover on the housing and make connection as the wiring diagram instructs, then reposition the terminal block cover.
INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE
Read and save these instructions!
Please use this card as hole cutting template 420mm×275mm.
EXHAUST
BLOWER
HEATER 1
HEATER 2
LIGHT
L
N
IN
220V
-240V
M: Motor C: Capacitor : Thermal protector IN: Light lamp
MANROSE PTC Heater Fan & Light
WARNING: Indicates that injury or death could occur if below Warnings are not followed.
This unit must be installed to comply with the appropriate council regulations and the Australia and New Zealand wiring rules AS/NZS3000:2000 or lastest edition thereof.
All wiring must be carried out by a Licensed Electrician in accor­dance with all applicable codes and standards.
Use this heater only as described in this manual. The manufacturer does not recommend any other use as this may cause fire, electric shock, or injury to persons. If you have questions, contact the manu­facturer or local agent.
Make sure the power is off before the installation.
For the purpose of avoiding any dangerous gas leaking into your bathroom, the duct vent of the heater must not be laid together with the duct vent of air-fueled water heater or other open-fire appliances into the same flue.
The heater is to be installed so that switches and other controls cannot be touched by a person in the bath or shower.
This unit should not be installed directly above a shower or bathtub. The unit must not be installed in a position where water may splash onto the unit.
!
!
!
!
!
!
!
!
Dear customers Please read all instructions before commencing installation.
CAUTION: Possibility of damage to equipment, installation or premis­es if below Cautions are not followed.
The appliance shall, under no circumstances, be covered with insulating material or similar material.
Regulations concerning the discharge of air have to be fulfilled.
The unit must not be installed beneath a fixed socket.
The unit is designed for installation in flat ceilings only. Do not mount
it on a sloping ceiling or a vertical wall.
Before commencing any cutting, check in the ceiling space that there are no obstructions such as electrical wiring, hidden utilities or ceiling joists and that there is sufficient height clearance for the unit. Check that the electrical wiring can be routed from the wall switches to the mounting location.
Joists, beams and rafters shall not be cut or notched to install the appliance.
so generally the unit would be mounted in a place where you would stand to dry yourself. For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room. Generally, this air would be drawn under the door with a minimum space of 20mm. If the room is airtight, the fan extraction will be reduced.
9. Replace the fascia
Reattach and screw the fascia onto the unit. Replace the plastic screw covers. Note: If it is necessary to run the wiring on the outside of the wall, use a suitable conduit and fixings to properly locate and hold the wiring used.
7. Fit one end of the duct to the fan outlet, and fix with duct clip. Note: Keep the route as straight and tight as possible.
USE
Our bathroom heater uses a ceramic PTC element as a source of heat. It also combines the functions of exhaust and light.
1. Power
‘POWER’ button On/Off Switch on the ‘POWER’ button to operate the unit.
bathroom heater
spring clip
ceiling
ceiling joist
100
100
220mm
100mm minimum clearance is required near all ceiling joists
8. Position the housing into the hole
Choosing the best direction to put the housing into the hole in accordance with the position of the fan outlet. Pull in the installation clips in the sliders before inserting the housing into the hole to avoid damaging the plaster. Release clips in the sliders and use screws to fasten the unit onto the ceiling.
Note: Try to keep the excess wire away from the housing.
This warranty does not cover damages or loss caused by:
1) Any consequential losses arising from incorrect installation or operation or maintenance of this product.
2) Any consequential losses arising from incorrect wiring of this prod­uct.
3) Any modifications or changes made to the unit, other than those recommended by the Manufacturer.
WARRANTY
The unit is warranted against defects in manufacturing and workmanship for a period of 5 years. The warranty does not extend installation of the unit or any associated wiring or any damage caused by installation or wiring. The installation must be conducted by a licensed electrician and a suitable certificate of safety is to be issued by the electrician who installed the unit. Warranty claims will be voided unless a certificate of safety can be produced when required, prior to service or repair.
MAINTENANCE Clean
1) Shut off the power before cleaning.
2) Wipe the fascia with care using a soft damp cloth.
3) Allow to dry thoroughly before switching on.
Note: Ensure the unit is cool enough to touch before handling.
Note: Do not switch on/off frequently when in use. Shut off the power
if in long vacancy.
3. Exhaust
‘FAN/HEATER 1’ button This switch will extract air from the room. When in the FAN position there is no heating of the room.
2. Lighting
‘LIGHT’ button On/Off This switch controls the light.
4. Heating
‘FAN/HEATER 1’ button When this switch is in the “HEATER 1”position, the heater unit will be activated. When the “HEATER 1” is turned on, half heating is applied to the room. When the “HEATER 2” is also turned on, full heating is applied to the room. When operating the heater there is no extraction.
MAIN TECHNICAL PARAMETERS
LIST OF PARTS
Operation unit
Installation instruction & hole-cutting template
1 piece
1 piece
Alluminum ducting 3.0m 1 piece
Duct clip
Switch 1 piece
2 piece
Egg-crate external grille 1 set
Model Number
Rated Voltage
Rated Frequency
Rated Power
220V-240V
50Hz
2250W
Please use this card as hole cutting template 420mm×275mm.
Read and save these instructions!
INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE
We reserve the rights to revise these instructions without any prior notice.
For warranty purposes fill out the following details and save with proof of purchase. This information must be submitted in the unlikely event that this product fails.*
MODEL NO.:
FAN5875
Purchased from:
Date of purchase:
*All warranty claims must be submitted through returns@simx.co.nz
FAN5875
Loading...