About this Manual
!
To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument
Menu
Category
Parameter
Name
Choices /
Format
DescriptionTech
Note
in compliance with its original advertised specifications.
Notes and Safety Information
This Instruction Manual contains warning headings that alert the user to check for hazardous
conditions. These appear throughout this manual where applicable, and are defined below. To
ensure the safety of operating performance of this instrument, these instructions must be adhered to.
Caution, refer to accompanying documents.
Caution, risk of electric shock.
Technical Assistance
SIMPSON ELECTRIC COMPANY offers assistance Monday through Friday
8:00 am to 4:30 pm Central Time by contacting Technical Support or
Customer Service at (715) 588-3311. Internet: http://www.simpsonelectric.com
SP4000040*
rStPos000000*
SP4
Set point #2 High.
Values: -99999 to
999999. Decimal point
will appear according to
the current Output 2
Source setting.
Reset Position
Count value is set to this
when an Auto or Manual
Reset event occurs.
Values: -99999 to
999999. Decimal point
will appear according to
the user-programmed
Count DP position
4.6
4.6
Warranty and Returns
SIMPSON ELECTRIC COMPANY warrants each instrument and other articles manufactured
by it to be free from defects in material and workmanship under normal use and service, its
obligation under this warranty being limited to making good at its factory or other article of
equipment which shall within one (1) year after delivery of such instrument or other article of
equipment to the original purchaser be returned intact to it, or to one of its authorized service
centers, with transportation charges prepaid, and which its examination shall disclose to its
satisfaction to have been thus defective; this warranty being expressly in lieu of all other warranties expressed or implied and of all other obligations or liabilities on its part, and SIMPSON
ELECTRIC COMPANY neither assumes nor authorizes any other persons to assume for it any
other liability in connection with the sales of its products.
This warranty shall not apply to any instrument or other article of equipment which shall have
been repaired or altered outside the SIMPSON ELECTRIC COMPANY factory or authorized
service centers, nor which has been subject to misuse, negligence or accident, incorrect wiring
by others, or installation or use not in accord with instructions furnished by the manufacturer.
Under the normal field usage there is no need to remove the front bezel of this product. The
front bezel of this product should only be removed by a qualified technician.
Menu
Category
rESEt
SEtuP
Parameter
Name
ArESEtdiSAbL*
rStbtnenable*
PonrStno*
Choices /
Format
At SP1
At SP2
At SP3
At SP4
AFtoP1
AFtoP2
diSAbL
YES
DescriptionTech
Auto Reset Mode
Selects when an auto
reset function is to occur.
Disabled at a set point or
after output times out.
See also the RSTPOS
parameter in the SetpntSetup category
The S663 preset counter and rate meter fits a 1/8 DIN standard cutout and is perfect for tight
spaces, extending only 3.24” (82mm) behind the panel. The unit is UL listed. The unit is for
indoor use at altitudes up to 2000m, temperatures between 0° and 40°C, and installation category III, pollution degree 2.
The counter is powered from 120 or 240 VAC. The nonvolatile EEPROM retains all programming and count information when power is removed or interrupted.
Category
Name
tiMmEd <—
LAtCHEd<—
SP3=Lo <—
dELAY2010.00*
untiL2rESEt *
Format
—>At SP3
—>AtSP3*
—>SP4=Hi
SP1
SP2
SP3
SP4
Output 2 Bindings
Reminder message
indicates which and how
the set points are used
for comparison. Which
message is displayed is
determined by the
Output 2 mode
selected.
Delay 2
Output 2 delay time.
Appears only if Output 2
mode set to timed.
Until 2
Output 2 latched until
parameter. Appears only
if MMode2 = latch and
SRC2 = Count.
Note
4.5
4.5
4.5
Display scaling, preset values and all menu functions are easily programmed from the front
panel, following easy-to-use word prompts. Front Panel Reset Disable and Password Lockout
Protection features guard against unauthorized or accidental changes.
The counter accepts count rates up to 20 KHz and pulses from different types of sensors, including Quadrature, CMOS or TTL circuits and PNP or NPN devices.
The optional, field-replaceable, single/dual relay module enhances the counter from a passive
display device to an integral control element for your application. Outputs may be controlled
by count or rate values with independent reset operation. The counter has latching, boundary or
timed (0.01 to 599.99 seconds) alarm output modes.
An optional 12 VDC (100mA) excitation output module can provide power for external sensors.
rStPoS
* = factory default settings
336
Menu
Parameter
Choices /
1.2 Part Number Identification
DescriptionTech
Category
oPut 2
SEtuP
Name
Format
untiL 1rESEt*
SP1
SP2
SP3
SP4
rStPoS
m M odE2diSAbL
tiMmEd
LAtCH*
bound
SrC 2Count*
rAtE
Until 1
Output 1 latched until
parameter. Appears only
if M m odE1 = LAtCHand
SrC1 = Count.
Output 2 Mode
Set the mode of
operation for Output 2.
Can be disabled, timed,
latched or boundary
mode.
Output 2 Source
Select which Display
Value to be used for
Note
4.5
4.5
4.5
The following matrix indicates the configuration of your S663 counter.
Basic Unit
S663
Power Supply
120 VAC
240 VAC
1
2
Input
Standard
Quadrature
Output
1
2
One relay
Two Relays
None
0
1
2
Excitation
None
12VDC
0
1
1.3 Option Module Summary
Other
None
0
output 2 comparisons/
matchpoint. See also
SP3 and SP4.
* = factory default settings
1
InputExcitationPower
2
4
Supply
5
Output
Figure 1. Option Module Slots (Rear View)
The S663 is a modular product which uses field configuring slide-in modules. The modules
slide easily into the rear of the counter. Figure 1 displays the functional assignments for each
module position.
Table 1 describes available option modules for the S663.
The S663 1/8 DIN counter requires a standard 1/8 DIN panel cutout of 1.77” (45mm) high by
3.62” (92mm) wide. To install the counter into a panel cutout, remove the clips from the side
of the counter. Slide the counter through your panel cutout, then slide the mounting clips back
on. Press evenly to ensure a proper fit.
3.62"
92mm
3.24"
82mm
1.77"
45mm
1.74"
44mm
2.04"
51.8mm
Category
Name
Format
SrC 1Count*
rAtE
tiMmEd<—
LAtCHEd<—
SP1=Lo <—
—>At SP1
—>AtSp1*
—>SP2=Hi
Output 1 Source
Select which Display
Value to be used for
output 1 comparisons /
matchpoints. See also
SP1 and SP2.
Output 1 Bindings
Reminder message
indicates which and how
the set points are used
for comparison. Which
message is displayed is
determined by the
Output 1 Mode
selected.
Note
4.5
4.5
ENTER
3.93"
.52"
13.2 mm
%
RESET
99.8 mm
Figure 2. Counter and Panel Cut-Out Dimensions
dELAY1010.00*
* = factory default settings
Delay 1
Output 1 delay time.
Appears only if Output 1
mode set to timed.
4.5
Figure 3. Panel Mounting Clips