• UL Recognized - File # E91015
Except for the Wattmeters &
Frequency Meters
• Plastic case with Glass Window
• Calibration not affected when
mounted on steel
• Three popular sizes:
2-1/2”, 3-1/2”, 4-1/2”
Rectangular Style
Analog Panel Meters
For Specications and Dimensions see the last pages
Ordering Information
Frequency, Self-Shielding Movement
Range Voltage
45-55 Hz 120V 35136 35142 35148
55-65 Hz 120V 35138 35144 35150
380-420 Hz 120V 35140 35146 35152
45-55 Hz 240V 35137 35143 35149
55-65 Hz 240V 35139 35145 35151
380-420 Hz 240V 35141 35147 35153
2-1/2”
Model 187
Not
Model / Size and Catalog Number
3-1/2”
Model 87
Model 89
4-1/2”

Rectangular Style
Analog Panel Meters
Frequency Meter Specications
Accuracy 45-55 Hz ± 0.3 Hz (120V-240V)
55-65 Hz ± 0.3 Hz (120V-240V)
380-420 Hz ± 1.2 Hz (120V-240V)
Movement Small core magnet, self-shielding
Suspension Pivot and jewel
Shielding Calibration is unaffected by magnetic panel mounting
H
Center Scale Value 50/60/400
Power Consumption 1.6 VA
Warm-up Time 5 minutes
Max. Input: Voltage (10 sec) 150, 120V normal
280, 240V normal
z
Dial Sharp clear scale.
Case High density black plastic
Operating Temperature -4ºF to + 149ºF (-20ºC to + 65ºC)
Pointer Spade pointer with black, matte nish
Scale Length Model 187: 1.8” (45.7mm)
Net Weight Model 187: 5 oz. (0.14 kg)
Each dial arc is calibrated to track the specic type of movement used
Model 89: 3.5” (89.0mm)
Model 87: 3.9” (99.0mm)
Model 87: 8 oz. (0.23 kg)
Model 89: 11 oz. (0.31 kg)