Simpson Electric Amik 200, Amik 201 Product Information Sheet

Application
Amik 200 /201
Amik 200/ 201
panel meters. It measures electrical parameters like AC Voltage, AC Current, Frequency, Active, Reactive, Apparent Power, Import Export Energy & many more.
Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog
Product Features
On site programmable PT / CT ratios
User selectable CT Secondary 5A /1A
User selectable PT Secondary
Low back depth
Four function keys
Demand Measurement
3 line 4 digits LED display
RPM Measurement
Energy Count Storage
User selectable 3 phase 3 Wire or 4Wire or Single phase Network
Onsite selection of Auto scroll / Fixed Screen
It is possible to program primary of external potential Transformer (PT), primary of external Current Transformer (CT) on site via front panel keys by entering into Programming mode.
The secondary of external Current Transformer (CT) can be programmed on site to either 5A or 1A using front panel keys.
The instrument has very low back depth (behind the panel) of less than 55 mm (Without output option).
Using the four function key, it is possible to go desired parameter screen instantly..
Measures & Displays Current Demand, kVA Demand, kW Import Demand, kW Export Demand. Any of the parameters can be assigned to optional Limit switch.
Simultaneous display of 3 Parameters.
The instrument display Rotation per minutes for generator applications. Number of poles can be set on site depending upon application requirement.
In case of power failure, the instrument memorizes the last energy count. Every 1 min, the instrument updates the energy counter in the non-volatile memory.
User can program on site the network connection as either 3 Phase 3 Wire or 4 Wire or single phase network using front panel keys.
,QFDVHRIVHOISRZHUHGFRQÀJXUDWLRQHLWKHU
3 Phase 4 wire or single phase network is available.
Optional Pulse Output / Limit switch (Relay output)
Pulse Output
Limit Switch
Optional MODBUS (RS485) Output
Storage of parameters possible
Enclosure Protection for
(for back)
dust and water
IEC60529.
EMC Compatibility
Interference Emission
Interference Immunity
Electrostatic discharge contact /air. (ESD)
EM Field
Not Available
Not Available
Not Available
The optional Modbus output enables the instrument to transmit all the measured parameters over standard MODBUS (RS-485).
RS-485
The MODBUS com
The instrument stores minimum and maximum values for System Voltage, System Current, Run Hour, ON Hour & number of Interrupts. Every 60 sec stored values are updated.
Conforms to IP 50 (for front face) & IP 20
Compliance to International standard IEC 61326.
IEC 61326-1 : 2005, Class A
IEC 61326-1 : 2005
IEC 61000-4-2 -- 4kV/8kV
IEC 61000-4-3 -- 10 V/m (80 MHz to 1 GHz) – 3 V/m (1.4 Ghz to 2 GHz)
-- 1 V/m (2 GHz to 2.7 GHz)
Product Features
Amik 200 /201
True RMS measurement
Energy Measurement
(Import & Export)
The instrument measures distorted wave form up to 15th Harmonic.
Active Energy (kWh), Reactive Energy (kVArh), Apparent Energy (kVAh). Any of the parameters can be assigned to optional Pulse output.
Customer can assign the format for energy display on MODBUS (RS-485) in terms of W, kW or MW. Additional to this, customer can also set a rollover count from 7 to 14 digits depending on the energy format, after which the energy will roll back to zero.
Burst Surge Conducted RF
Rated Power Frequency magnetic Field
Voltage dip
-- 70% during 25/30 cycles.
Short interruptions cycles.
IEC 61000-4-4 -- 2 kV (5/50 ns, 5 kHz)
IEC 61000-4-5 -- 1 kVLL / 2 kVLN. IEC 61000-4-5 -- 3 V (150 kHz to 80 MHz)
IEC 61000-4-8 -- 30 A/m
IEC 61000-4-11 -- 0% during 1 cycle.
-- 40% during 10/12 cycles.
IEC 61000-4-11 -- 0% during 25/30 cycles.
25 cycles for 50 Hz test. 30 cycles for 60 Hz test.