Simpson Electric 501 User Manual

Page 1
Five Test Voltages: 50, 100, 250, 500, and 1000 VDC
Voltage Measurement to 1000 V AC/DC
Test Probe Signal Lamp Illuminates Work Area and Indicates Pass/Fail of Insulation Resistance
Battery Powered with Battery Test and Battery Charge Indicator
Rugged Tester Design for Industrial Applications with Leatherette Carrying Case
501 Insulation Tester
Ordering Information
ACCESSORIES Catalog No.
501 Insulation Tester, 1000 V 12501
INSULATION RESISTANCE
DIRECT AND ALTERNATING CURRENT
(1) Referring to scale length
REFERENCE CONDITIONS Ambient Temperature: 73F (23C) 4F (2C) Relative Humidity: 45 to 55% Measurement Magnitude Frequency: 45-65 Hz (voltage measurements) Line Voltage Waveform: Sine, deviation between effective and rectified value < .5% Battery Voltage: 9V .5V Operating Position: Horizontal
ELECTROMAGNETIC COMPATIBILITY EMC Interference Emission:
EN 50081-1: 1992
Interference Immunity:
EN 50082-1: 1992
ELECTRICAL SAFETY Designed to IEC 1010-1 Protection Class: II Test Voltage: 5.55Kv Overvoltage Classification: II Pollution Degree: 2 Protection: Housing IP52
AMBIENT CONDITIONS Operating Temp. Range: 32F (0C) to 104F (40C) Storage Temp. Range: -4F (-20C) to 140F (60C) (without batteries) Relative Humidity: Max. 45-55%, condensation must be avoided MECHANICAL DESIGN Dimensions:
W
6.50” (165mm) x
D
4.33” (110mm) x H 4.92” (125mm)
Weight:3.5 lbs. (1.6kg) (with batteries) POWER SUPPLY
Standard or Storage Battery: 6 ea. 1.5V “D” size batteries Working Range:7V to 10V Battery Service Life: Number of possible measurements with 1 set of “D” size
batteries (with lamp in test prod switched off): at least 3,000 measurements of an insulation resistance of 1M(Nominal Voltage of1000 V, 5 sec. Measurement duration, switched off for 25 sec. etc.)
Specifications
(1) Switching Accuracy
Measuring Ranges
Measuring
Range Open-Circuit Voltage
Uo
Internal Resist ance R
i
Lamp in Test Prod
1)
Lights for Resistance
0…50K
20K…1M
200K…20M
60V
30K 10K 40K
> 100K
0…100K
40K…2M
400K…40M
120V
60K 20K 80K
> 200K
0…250K
100K…5M
1M…100M
300V
150K
50K
200K
> 500K
0…500K
200K…10M
2M…200M
600V
300K 100K 400K
> 1M
0…1M
400K…20M
4M…400K
1200V
600K 200K 800K
> 2M
0…4K 9V
⫺⫺
Measuring
Range Frequency
Internal
Resistance
Maximam
Overload Intrinsic Error (1)
0 to 1000V
AC/DC
0 or 40 to 200Hz 900K 1200V AC/DC
Continuous
2.5%
rev_1 11/2/04